Application for Drive Technology

Similar documents
Drive System Application

Drive System Application

Closed-loop torque control and load distribution

Welcome to ABB machinery drives training. This training module will introduce you to the ACS850-04, the ABB machinery drive module.

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

SINAMICS GM150 IGCT version

SINAMICS DCC Winder V4.2.

MAGPOWR Spyder-Plus-S1 Tension Control

Super Calendar. Heated rolls

Super Calendar. Heated rolls

Center Winder Specification

SINAMICS DCM. DC Converter. Application SINAMICS DCM as field supply unit. Edition 04-6/2013. SINAMICS drives

Technical Explanation for Inverters

Safety Integrated for entry level personnel SINAMICS. SINAMICS G converters Safety Integrated for entry level personnel. Hazards in plants and

Small step, big impact: Energy efficiency and dynamic performance

CPW Current Programmed Winder for the 890. Application Handbook. Copyright 2005 by Parker SSD Drives, Inc.

Guide for Primary Injection Testing WL Circuit Breakers. Document No. : 11-C

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

Standard Drives A & D SD Application Note

Good Winding Starts the First 5 Seconds Part 2 Drives Clarence Klassen, P.Eng.

SINAMICS G130. Motor reactors. Operating Instructions 05/2010 SINAMICS

Converting Applications Made Easy Presented by Jeff Reese Manufacturing in America March 14-15, 2018

Preferred Series 215 kw to 1500 kw. Catalog DA /2000

RT2DB Excitation and voltage regulation system for synchronous generators

Código de rotor bloqueado Rotor bloqueado, Letra de código. Rotor bloqueado, Letra de código

Roll Diameter Requirements in Converting Processes

Parker AC10 Frequency Inverter (to 22kW) Easy Start Guide

Piktronik d. o. o. Cesta k Tamu 17 SI 2000 Maribor, Slovenia Fax:

Tension Control Inverter

Inverter control of low speed Linear Induction Motors

IOM A-0984E IP68-420DC AUTOMATED PILOT ACTUATOR Installation and Operation Manual

Introduction. 1/2 Overview 1/3 Benefits 1/3 Application. 1/3 Order No. code. 1/4 Protection strategy

SINAMICS drives SINAMICS DCM. DC converters from 6 kw to 2500 kw for variable-speed direct-current drives

Detailed comparison of winding and tension control solutions. Unrestricted Siemens AG 2017

Number 1 in efficiency

Designing Drive Systems for Low Web Speeds

Tension Control Systems

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

The MICROMASTER has four modes of operation:

FAQ about Drives Technologie

Installation Power Management Unit Battery Cables and Battery Harness

Electrical Engineering Info

MASTERDRIVE Compact Plus

System Monitoring SCHOOLMETERBOX AU

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

TECHNICAL BRIEF Americas

Operation Manual for Torque Sensors

Application Note EMC - Checklist

Commissioning Manual AC Servo Actuator LynxDrive SIEMENS SIMODRIVE

Permanent Magnet Synchronous Motor. High Efficiency Industrial Motors

Freedom egen System End-of- Line Functional Checklist

690+ Series Integrator

CENTROIDTM. AC Brushless Drive. Product Spec Sheet

Application Note. Common Bussing AC Drives. For 650 and 690+ series drives APP-AC-03

SCOPELITE TIMING LIGHT OPERATING MANUAL

Serial hoisting equipment with SINAMICS G120

KD LV Motor Protection Relay

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Assembly instructions

APPLICATION GUIDE. Pure easiness for a wide range of applications ACS580 general purpose drives

Technical Manual Electrical Power Supply System T4002

Hybrid Motor Technology to Achieve Efficiency Levels Beyond NEMA Premium

Product Information ECN 425 EQN 437. Absolute Rotary Encoders with Hollow Shaft and Expanding Ring Coupling for Safety-Related Applications

Kelly HSR Series Motor Controller with Regen User s Manual V 3.3. Kelly HSR Opto-Isolated Series Motor Controller with Regen.

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

Planning and Commissioning Guideline for NORD IE4 Motors with NORD Frequency Inverters

Asynchronous motors. 7/2 Main spindle motors for SIMODRIVE 611 7/2 Introduction

TRIPS AND FAULT FINDING

Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG iss 9 1

Features IN THIS CHAPTER

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

Web Volume Control Model WV220

Digital Pressure Regulator Sentronic PLUS Series 614

Displacement Sensor. Model 8739, 8740, 8741

Installation instruction Sound Booster Pro Active Sound

Number 1 in efficiency

Asynchronous motors. 5 Asynchronous motors 5/2 Type overview and rated data 5/4 Technical definitions 5/4 Encoder systems

VLT AutomationDrive for marine winch applications

BLDPN30001 Series. 30A Brushless DC Controller. User s Guide E. Landon Drive Anaheim, CA

ADJUSTABLE FREQUENCY CONTROLS SENSORLESS VECTOR CONTROL. Dual Rating. Technologies Inc. mgitech.com NRTL/C CERTIFIED

TOSVERT VF-S11. V/F control functions

CETOP POSITION PAPER PP 07

Inverter MICROMASTER 440

Winding technology, pneumatically actuated tension brakes web tension open-loop and feedback control systems

HT Dielectric Withstand Tester Volts AC Output 25mA Leakage Option

SIRIUS Soft Starters Introduction

DEEP SEA ELECTRONICS PLC DSE3210 Configuration Suite Software Manual

Installation Instructions. Y-Series Brushless Servo Motor

ZF Friedrichshafen AG Special Driveline Technology. Hysteresis brakes Hysteresis clutches Electronic control unit

SIMOTION Line Tension Control V Unrestricted / Siemens AG All Rights Reserved.

SIMOREG SIMOREG DC-MASTER. 6RA70 Series

PowerFlex AC Drives Portfolio

MOTORS. Part 2: The Stepping Motor July 8, 2015 ELEC This lab must be handed in at the end of the lab period

Important instructions

Application Note CTAN #127

Products for specific requirements

Tension and Compression Load Cell Model 8435

Servo Motors B-1. Introduction B-2. NX Series B-9. Accessories B-47

CSDA Best Practice. Hi-Cycle Concrete Cutting Equipment. Effective Date: Oct 1, 2010 Revised Date:

Installation & Operation Manual

Transcription:

Application for Drive Technology MICROMASTER 4 Application Description MICROMASTER 440 Basic Winder Drive for Steel Wire

Warranty, Liability and Support 1 Warranty, Liability and Support We do not accept any liability for the information contained in this document. Any claims against us based on whatever legal reason resulting form the use of the examples, information, programs, engineering and performance data etc., described in this document shall be excluded. Such an exclusion shall not apply in the case of mandatory liability, e.g. under the German Product Liability Act ( Produkthaftungsgesetz ), in case of intent, gross negligence, or injury of life, body or health, guarantee for the quality of a product, fraudulent concealment of a deficiency or breach of a condition which goes to the root of the contract ( wesentliche Vertragspflichten ). However, claims arising from a breach of a condition which goes to the root of the contract shall be limited to the foreseeable damage which is intrinsic to the contract, unless caused by intent or gross negligence or based on mandatory liability for injury of life, body or health. The above provisions does not imply a change in the burden of proof to your detriment. The Application Examples are not binding and do not claim to be complete regarding the circuits shown, equipping and any eventuality. They do not represent customer-specific solutions. They are only intended to provide support for typical applications. You are responsible in ensuring that the described products are correctly used. These Application Examples do not relieve you of the responsibility in safely and professionally using, installing, operating and servicing equipment. When using these Application Examples, you recognize that Siemens cannot be made liable for any damage/claims beyond the liability clause described above. We reserve the right to make changes to these Application Examples at any time without prior notice. If there are any deviations between the recommendations provided in these Application Examples and other Siemens publications e.g. Catalogs then the contents of the other documents have priority. Copyright 2005 Siemens A&D. It is not permissible to transfer or copy these Application Examples or excerpts of them without first having prior authorization from Siemens A&D in writing. For questions about this document please use the following e-mail-address: mailto:csweb@ad.siemens.de A&D SD Page 2/15

2 Definitions and Warnings 2.1 Qualified personnel In the sense of this documentation qualified personnel are those who are knowledgeable and qualified to install, mount, commission, operate and service/maintain the products to be used, e.g.: o o o Trained and authorized to energize, de-energize, clear, ground and tag circuits and equipment in accordance with established safety procedures. Trained in the proper care and use of protective equipment in accordance with established safety procedures. Trained in rendering first aid. Warning information and instructions will not be explicitly referred to in this documentation. However, reference will be clearly made to warning information and instructions in the Operating Instructions for the particular product. 2.2 User group The application software and the application example were developed to support Siemens personnel in the generation of user programs for machines or systems. This is not intended to be directly passed-on or sold to persons/companies outside Siemens AG. Application software may only be passed-on as part of a complete machine for plant software. If passed-on to persons/companies outside Siemens AG who are not involved in a total project integrated application software, then the person or persons who transferred this information carry full responsibility for an liability or damage claims. Only qualified personnel may use the application software and the application example. If this is incorrectly used, this can result in the plant or system being destroyed and/or injury to personnel. 2.3 Applicable conditions The valid edition for the general conditions of sale and delivery for products and services within Siemens applies.

Definitions and Warnings 2.4 Information regarding trademarks SIMOVERT is a Siemens registered trademark MICROMASTER is a Siemens registered trademark 2.5 Revisions/author Version Date/change Author 1.00 14.01.03 / Erstausgabe Haßold A&D SD Page 4/15

Introduction 3 Introduction When winding or unwinding various materials, different requirements are placed on the winder drive and the closed-loop winder control. When winding sensitive materials, e.g. foils or paper, where there is a danger that the material web could break or could be damaged, then at every point in time during the winding operation, it must be ensured that the web tension is kept constant. Generally this is achieved by sensing the diameter or calculating the diameter and detecting the tension with a dancer roll or tension transducer. As an alternative to sensing the tension, this can also be entered using the indirect closed-loop control. When selecting the correct closed-loop control version, it is important to know which material is to be wound, and the secondary conditions regarding the required control quality, material web velocity, diameter range and control range of the material web. For extremely complex closed-loop winder controls which are used to wind sensitive materials with a high web velocity, we recommend the use of preconfigured solutions in conjunction with MASTERDRIVES or SIMOREG drives from Siemens with additional technological modules for example T300 or T400 modules. In addition to these complex closed-loop winder controls, there is also a series of applications which only require a very basic closed-loop winder control. For example this involves winding steel wire with a diameter greater than 1mm. In this case, in most cases it is sufficient to use the drive inverter to limit the winding torque. The simplest closed-loop control version for winders is the torque limiting. In this case, it is not necessary to determine the diameter as the speed controller in the drive inverter goes to its limit and it is not necessary to have a speed setpoint input for the drive inverter which is corrected as a function of the actual roll diameter. An appropriate winder application to wind steel wires with a diameter of >1mm will be described in the following. The following sketch provides a rough overview of the possible closed-loop control techniques when winding. A&D SD Page 5/15

Introduction Closed-loop control structure Indirect closedloop tension control Direct closed-loop tension control Closed-loop constant V control Torque limiting Tension sensing using a tension transducer Tension sensing using a dancer roll Copyright Siem ens AG 2005 All rights reserved Fig. 1-1: Closed-loop control structures for winder drives If the diameter of the wound material is to be determined, then the following techniques can be applied. Determining the diameter Diameter sensing Diameter not determined Diameter calculation Diameter sensing with sensor Diameter sensing using a counter count No. of turns v/n diameter calculation Iterative diameter calculation Fig. 1-2: Techniques to determine the roll diameter A&D SD Page 6/15

Closed-loop control structure 4 Closed-loop control structure The winder drive, described in the following text, is used to wind steel wire. In this case, the drive operates motoring and generally regenerative operation only occurs for brief braking ramps and for high moments of inertia of the winder. The DC link voltage controller, integrated in the MICROMASTER440, avoids overvoltage trips where the drive would then be shut down. This means that a braking resistor can be frequently eliminated. This is only required if, when quickly reducing the wire velocity with a full roll, the tension force F Z is too high as a result of its moment of inertia. The winder drive must provide the full torque at low speeds and large roll diameter. This means that under certain circumstances, the motor cannot be adequately cooled. Depending on the speed control range and the thermal reserves in the motor, it may be necessary to equip the motor with a separately-driven fan. 4.1 Operation as winder With increasing diameter of the material being wound, the winding hardness (tension force F Z with which the wire is wound) should decrease in the same ratio so that the wire doesn't "cut-in" to the roll of wire ( F Z ~1/D W ). The required winding torque M W of the drive is given by: M W F Z D W D M W FZ * 2 W = whereby: = actual winding torque at the load in (Nm) = tension with which the steel wire is wound in (N) = actual roll diameter in (m) As the roll diameter D W increases, tension F Z should decrease then the winding torque M W, which the drive must provide, can remain constant. It is not necessary to enter a speed setpoint for the winder drive which is a function of the diameter. In this particular case, it is not necessary to sense the diameter or calculate the diameter. This means that only one possibility is required at the drive inverter to set the torque for the motor, and therefore the winding torque. A&D SD Page 7/15

Closed-loop control structure In order to keep the winding torque M W constant, closed-loop torque control or closed-loop frequency control with torque limiting can be used as control version in the MICROMASTER440. The closed-loop frequency control with torque limiting has the advantage, that if the wire breaks, then the winder drive does not accelerate up to the selected maximum frequency. If the latter closed-loop control version is used, the speed controller of the MICROMASTER440 drive inverter goes to its limit, the downstream torque limiting limits the torque and therefore the motor slip. In the application described, the closed-loop torque control and limiting does not require high accuracy and the torque setpoint can be entered in an open-loop controlled fashion at zero speed to tension the wire. This is the reason that speed feedback is not required for this particular application. For closed-loop frequency control with torque limiting, the frequency setpoint for the drive inverter must always be entered somewhat higher at the minimum roll diameter (=core diameter) (approx. 10%) than corresponds to the actual wire velocity, so that the drive inverter reliably goes into torque limiting with the larger slip. As the roll diameter D W increases, the drive automatically runs slower at constant winding torque M W and decreasing tension force F Z as a result of the torque limiting. In this case, the continuous deviation between the frequency setpoint and actual value which is obtained does not play a role. 4.2 Operation as unwinder The control structure described above is not suitable for an unwinder drive as in this case only a regenerative torque can be limited. However, when accelerating the unwinder while the system accelerates, the drive must provide a defined (motoring) accelerating torque. Otherwise, an inadmissibly high torque F Z would be obtained when starting, and the wire could, under certain circumstances, break. In this case it makes sense to provide a direct closed-loop tension control - e.g. using a dancer roll and the PID controller integrated in the drive converter. This control version will be described as part of a subsequent application. A&D SD Page 8/15

Parameter settings 5 Parameter settings Parameters can be set using the BOP / AOP operator panels or the DriveMonitor or Starter visualization programs. The Starter program offers a user-friendly way of carrying-out prompted commissioning which will also be described in the following steps. 5.1 Basic commissioning To start, prompted commissioning should be initiated using the button "Reconfigure drive" in the menu <Configuration> (Steps 1 and 2). In this case, among other things, the rating plate data of the motor, ramp-up and rampdown times, control mode and command and setpoint source should be set. "Vector control without sensor" should be selected as control mode. At low frequencies (<5Hz), in this case the torque limit and therefore the tension are permanently set. Pulse encoder feedback is required if a variable and precise torque must be entered, even at low frequencies. This means that tension F Z can be set in a defined fashion down to zero speed. The appropriate parameter setting is then "Vector control with sensor". For example, the "Terminal strip" and "Analog input" or Profibus "CB at COM link" can be used as command and setpoint source. The setpoint is entered as frequency setpoint and must be approximately 10% higher than the wire velocity. If the frequency setpoint is entered using a ramp, then the ramp-up and ramp-down time in the drive converter must be set less than this ramp so that the winder can follow the process. 1. 2. 3. 4. A&D SD Page 9/15

Parameter settings After the prompted commissioning, the motor identification (Step 3.) and saturation (Step 4.) must be determined in the <Configuration> menu. 5.2 Setting the application-specific parameters After the drive inverter has been basically commissioned, the parameters, specific to the particular application, must be set. The following points must be taken into consideration: o o o Torque limiting Setting the limit, open-loop/closed-loop controlled Torque boost in the open-loop controlled range at low frequencies 5.2.1 Torque limiting In order to limit the motor torque when motoring and therefore the tension when winding, the fixed max. torque limit must be entered into the drive inverter in the menu <Limits> / <Torque> (Steps 1 and 2) (Step 3, a negative value is required for P1520 for clockwise direction of rotation / "Maximum torque" and P1521 for counter-clockwise direction of rotation / Minimum torque"). Further, the effective torque limit can be variably entered from 0 Nm up to this upper limit value (P1520 / P1521). The source for the variable torque limit, e.g. analog input 2 or Profibus can be set in Step 4 (P1522 for clockwise direction of rotation / "Upper torque limit" and P1523 for counter-clockwise direction of rotation / "Lower torque limit"). For a counter-clockwise direction of rotation it should be observed that a negative value must be entered for the variable torque limiting (setting, e.g. using the ADC scaling P757-P760, Index 1 for analog input 2). The normalization of the variable torque limit is entered via the reference torque (P2003). In this case, a value of 100% at analog input 2 or Profibus corresponds to the value in P2003. The effective torque limit can be tracked using P1526 (Step 5). In this case it must be observed that here, at standstill, the value is in P2003 is displayed as maximum value, and in operation the actual value with P1520 / P1521 as maximum effective limit. A&D SD Page 10/15

Parameter settings 2. 1. 3. 4. 5. 5.2.2 Setting the limit, open-loop / closed-loop controlled In the sensorless mode, the MM440 drive inverter operates open-loop controlled in the lower frequency range. The reason for this is that the actual speed can no longer be precisely calculated in the drive inverter itself. In this open-loop controlled range, the motor torque is permanently set. It is not possible to additionally change this value, e.g. via an analog input. This means that it is desirable to reach the limit for the transition into the closed-loop controlled mode at frequencies which are as low as possible. In practice, depending on the drive power and the quality of the optimization, this is possible for frequencies between 1 and 5 Hz. The setting is made in the Expert list (refer to the Fig. below). In order to reach this, click-on <MICROMASTER_440> using the righthand mouse key and the Expert list selected (Step 1). The limits, with values of between 1 and 5 Hz are then entered using parameter P1755 (Steps 2 and 3). In this case it must be observed that a hysteresis (P1756) of 50% referred to P1755 is effective. A&D SD Page 11/15

1. 2 3.

Parameter settings 5.2.3 Torque boost in the open-loop controlled range and at low requencies This setting is made in the Expert list (refer to the Fig. below). In order to reach this, click-on <MICROMASTER_440> using the righthand mouse key and the Expert list selected (Step 1). The torque in the open-loop controlled range and therefore the tension are set using fixed parameter values. If the frequency is kept constant in the open-loop controlled range, then the torque is entered, using P1610 (refer to the Fig. below, Steps 2 and 3) as a percentage of the rated motor torque. An accelerating torque can be additionally parameterized using P1611 (Steps 4 and 5) in order to accelerate moments of inertia. This is especially practical, if, when starting, the tension F Z in the wire is too low due to the accelerating component of the torque. 1. 2. 3 4. 5. A&D SD Page 13/15

Secondary conditions and limitations 6 Secondary conditions and limitations The closed-loop control version with torque limiting, described above, is the simplest way of implementing a closed-loop winder control function and is suitable for basic wire winders. If the control quality has to fulfill higher requirements, then a faster tension controller with tension actual value sensing, diameter sensing and supplementary functions are required. In order to be able to estimate the described closed-loop control versions when engineering an application, the secondary conditions/limitations for an application, which has already been implemented, are listed below. Table 6-1: Technical data of an application example Description Values Comments Wire properties Steel wire with D>1mm With the described closedloop control technique, only possible with steel wire D>1mm. If closed-loop dancer roll control is used (this has not been described here), control is possible with other wire materials down to below D=0.1mm Wire velocity Approx. 150m/min With closed-loop dancer roll position control (this has not been described here) possible up to 2000m/min Minimum roll diameter 0.4m With the closed-loop control Maximum roll diameter 0.8m technique described here, a Dmax / Dmin diameter ratio of max. 4:1 is possible. A&D SD Page 14/15

Secondary conditions and limitations Minimum tension force F Zmin at the minimum roll diameter Maximum tension force F Zmax at the minimum roll diameter Tension force characteristic (winding hardness) Motor used Drive inverter used Wire laying drive 55N 270N F Z ~1/D W decreases with increasing diameter 1.1kW, 4 pole with gearbox i=14.48 MM440 1.1kW, 400V with options: Profibus module Shield connectingplate Sub-chassis line reactor Layed over an approximate width of approx. 0.5m For the closed-loop control techniques described, a tension force ratio F Zmax / F Zmin of max. 5:1 is possible. This is necessary so that for larger roll diameters the wire does not "cut into" the rolls. An MM420 drive is used to lay the wire over the width of the coil A&D SD Page 15/15