with central connector M2x Non corrosive spool and sleeve for long trouble free life 5/2 and Glandless Valves Actuated Sub-base Mounted ISO 5599- #, #2, #3 6 bar (4,5 W) and 0 bar (2 W) 24V DC solenoids with non-locking manual override Robust metal M2x connector with 4 pin s with surge surpression and LED indicator Wide range of sub-bases and accessories Technical Data Medium: Compressed air, 40µm filtered, lubricated or non-lubricated Operation: Glandless spool valve, solenoid pilot actuated Mounting: On sub-bases Sizes: ISO #, #2 and #3 Operating Pressure (maximum pressure): 0 bar (45 psig) solenoid pilot (2 W) actuated valves 6 bar (232 psig) solenoid pilot (4,5 W) actuated valves Details of minimum and maximum pilot pressure see overleaf Flow Characteristics (unregulated): Size Function C b A l/min Cv Kv ISO # 5/2 5,50 0,06 9,70 230,20,08 ISO # APB 5,70 0,,4 320,35,5 ISO #2 5/2 0,70 0,2 39,20 2450 2,45 2,6 ISO #2 APB 0,72 0,6 40,40 2520 2,57 2,20 ISO #3 5/2 9,00 0,4 70,45 4400 4,48 3,84 ISO #3 APB 9,84 0,6 74,54 4650 4,74 4,06 Ambient Temperature: C* to +50 C (F* to +22 F) solenoid pilot actuated valves *Consult our Technical Service for use below +2 C (36 F) Materials: Die cast aluminium body. Hard anodised, Teflon coated, matched aluminium spool and sleeve. Viton and nitrile rubber static seals. Zinc die cast locking plate. POM and PA plastic parts. Zinc plated screws. For technical data on ISO 5599- sub-bases and accessories see sections 5.4.87 and 5.4.88 Ordering Information To order select model from page 5.4.89.02 e.g. SXE9573-87-M for a 5/2 solenoid pilot (6 bar) / spring returned ISO # valve with internal pilot air supply. 4 5 4 2 3 2 5 F M 5/2 All ports blocked, mid position Centre open exhaust, mid position Centre open pressure, mid position 2/99 N/** 5.4.89.0
with central connector M2x General Information 5/2 Pilot Actuated Valves 6 bar (4,5 W) versions Symbol Model ISO Size Pilot Supply Operator Return Operating Pressure Pilot Pressure Weight bar (psig) bar (psig) kg (lb.) 4 2 SXE9573-870-M # - 6 SXE9574-870-M #2 Internal Air Spring - 0.59 (.34) (4.5-232) SXE9575-870-M #3 0.85 (.93) 4 SXE9573-875-M # 2-0.9-6 - 6 SXE9574-875-M #2 External Air Spring 0.59 (.34) (-3. - 232) (4.5-232) 2/4 SXE9575-875-M #3 0.85 (.93) 4 2 SXE9573-87-M #.8-6 SXE9574-87-M #2 Internal Spring - 0.59 (.34) (26. - 232) SXE9575-87-M #3 0.85 (.93) 4 2 SXE9573-876-M # -0.9-6.8-6 SXE9574-876-M #2 External Spring 0.59 (.34) (-3. - 232) (26. - 232) 2/4 SXE9575-876-M #3 0.85 (.93) 4 2 SXE0573-850-M # 2-6 SXE0574-850-M #2 Internal - SXE0575-850-M #3 0.96 (2.8) 4 2 SXE0573-855-M # -0.9-6 2-6 SXE0574-855-M #2 External (-3. - 232) 2/4 SXE0575-855-M #3 0.96 (2.8) 4 2 SXE573-850-M # 2-6 SXE574-850-M #2 Internal - (Priority) SXE575-850-M #3 0.96 (2.8) 4 2 SXE573-855-M # -0.9-6 2-6 SXE574-855-M #2 External (Priority) (-3. - 232) 2/4 SXE575-855-M #3 0.96 (2.8) Pilot Actuated Valves 6 bar (4,5 W) versions Symbol Model ISO Size Valve Function Pilot Supply Operator Return Operating Pressure Pilot Pressure Weight bar (psig) bar (psig) kg (lb.) 4 2 SXE9673-850-M # 2-6 SXE9674-850-M #2 APB Internal - SXE9675-850-M #3 0.96 (2.8) 4 2 SXE9673-855-M # -0.9-6 2-6 SXE9674-855-M #2 APB External (-3. - 232) SXE9675-855-M #3 0.96 (2.8) 4 2 SXE9773-850-M # 2-6 SXE9774-850-M #2 COE Internal - SXE9775-850-M #3 0.96 (2.8) 4 2 SXE9773-855-M # -0.9-6 2-6 SXE9774-855-M #2 COE External (-3. - 232) SXE9775-855-M #3 0.96 (2.8) 4 2 SXE9873-850-M # 2-6 SXE9874-850-M #2 COP Internal - SXE9875-850-M #3 0.96 (2.8) 4 2 SXE9873-855-M # -0.9-6 2-6 SXE9874-855-M #2 COP External (-3. - 232) SXE9875-855-M #3 0.96 (2.8) 2/4 2/4 2/4 Valve Function Designations: APB = All Ports Blocked COE = Centre Open Exhaust COP = Centre Open Pressure Electrical Details for Operators Pin Layout (Male Pin shown) Voltage / Power 24V DC / 4,5 W Spare coil with plug TM 602-03 Voltage Tolerance + 0% Rating 00% Continuous Duty Surge Surpression Varistor Indication Green LED Electrical Connection M2x Pin Layout 4 pin (see drawing) Protection Class IP 65 with sealed plug (ISO 6952) Push to operate spring return Inlet Orifice,0 mm 2 3 4 Pin : not used Pin 3: common minus Pin 2: 2 Pin 4: 4 N/** 5.4.89.02 2/99
AUTO STAR with central connector M2x 5/2 Pilot Actuated Valves 0 bar (2 W) versions Symbol Model ISO Size Pilot Supply Operator Return Operating Pressure Pilot Pressure Weight bar (psig) bar (psig) kg (lb.) 4 2 SXE9573-70-M # - 0 SXE9574-70-M #2 Internal Air Spring - 0.59 (.34) (4.5-45) SXE9575-70-M #3 0.85 (.93) 4 SXE9573-75-M # 2-0.9-6 - 0 SXE9574-75-M #2 External Air Spring 0.59 (.34) (-3. - 232) (4.5-45) 2/4 SXE9575-75-M #3 0.85 (.93) 4 2 SXE9573-7-M #.8-0 SXE9574-7-M #2 Internal Spring - 0.59 (.34) (26. - 45) SXE9575-7-M #3 0.85 (.93) 4 2 SXE9573-76-M # -0.9-6.8-0 SXE9574-76-M #2 External Spring 0.59 (.34) (-3. - 232) (26. - 45) 2/4 SXE9575-76-M #3 0.85 (.93) 4 2 SXE0573-50-M # 2-0 SXE0574-50-M #2 Internal - (29-45) SXE0575-50-M #3 0.96 (2.8) 4 2 SXE0573-55-M # -0.9-6 2-0 SXE0574-55-M #2 External (-3. - 232) (29-45) 2/4 SXE0575-55-M #3 0.96 (2.8) 4 2 SXE573-50-M # 2-0 SXE574-50-M #2 Internal - (Priority) (29-45) SXE575-50-M #3 0.96 (2.8) 4 2 SXE573-55-M # -0.9-6 2-0 SXE574-55-M #2 External (Priority) (-3. - 232) (29-45) SXE575-55-M #3 0.96 (2.8) 2/4 Pilot Actuated Valves 0 bar (2 W) versions Symbol Model ISO Size Valve Function Pilot Supply Operator Return Operating Pressure Pilot Pressure Weight bar (psig) bar (psig) kg (lb.) 4 2 SXE9673-50-M # 2-0 SXE9674-50-M #2 APB Internal - (29-45) SXE9675-50-M #3 0.96 (2.8) 4 2 SXE9673-55-M # -0.9-6 2-0 SXE9674-55-M #2 APB External (-3. - 232) (29-45) SXE9675-55-M #3 0.96 (2.8) 4 2 SXE9773-50-M # 2-0 SXE9774-50-M #2 COE Internal - (29-45) SXE9775-50-M #3 0.96 (2.8) 4 2 SXE9773-55-M # -0.9-6 2-0 SXE9774-55-M #2 COE External (-3. - 232) (29-45) SXE9775-55-M #3 0.96 (2.8) 4 2 SXE9873-50-M # 2-0 SXE9874-50-M #2 COP Internal - (29-45) SXE9875-50-M #3 0.96 (2.8) 4 2 SXE9873-55-M # -0.9-6 2-0 SXE9874-55-M #2 COP External (-3. - 232) (29-45) SXE9875-55-M #3 0.96 (2.8) 2/4 2/4 2/4 Valve Function Designations: APB = All Ports Blocked COE = Centre Open Exhaust COP = Centre Open Pressure Electrical Details for Operators Pin Layout (Male Pin shown) Voltage / Power 24V DC / 2 W Spare coil with plug TM 502-03 Voltage Tolerance + 0% Rating 00% Continuous Duty Surge Surpression Varistor Indication Green LED Electrical Connection M2x Pin Layout 4 pin (see drawing) Protection Class IP 65 with sealed plug (ISO 6952) Push to operate spring return Inlet Orifice,0 mm 2 3 4 Pin : not used Pin 3: common minus Pin 2: 2 Pin 4: 4 2/99 N/** 5.4.89.03
with central connector M2x SXE 9573 * Models Single Valves - ISO # SXE *573 * and SXE 9*73 * Models Double Valves - ISO # M2x M2x 55 (2,7 ) 69 (2,72) 55 (2,7) 69 (2,72) 4 M5 4 2 M5 43 (5,63) 204 (8,05) 36 (,42) 36 (,42) 42 (,65) 42 (,65) 8 (0,7) 83 (3,28) 28 (,0) 8 (0,7) 28 (,0) SXE 9574 * Models Single Pilot Valves ISO #2 SXE *574 * and SXE 9*74 * Models Double Pilot Valves ISO #2 M2x M2x 04,6 (4,2 ) 4 42 (,65) 8,7 (4,67) 4 2 42 (,65) 04 (4,2) 8,7 (4,67) 55 (6,) M6 08,8 (4,28) 8 (0,3) M6 08,8 (4,28) 204 (8,05) 8 (0,3) 48 (,89) 29 (,4) 48 (,89) 55 (2,7) 55 (2,7) 24 (0,94) 38 (,50) 24 (0,94) 38 (,50) N/** 5.4.89.04 2/99
with central connector M2x SXE 9575 * Models Single Valves - ISO #3 M2x SXE *575 * and SXE 9*75 * Models Double Valves - ISO #3 M2x 05,7 (4,6 ) 4 43 (,69) 50 (,97) 9 (4,68) 05,7 (4,6 ) 4 2 43 (,69) 9 (4,7) M8 35 (5,33) 66,6 (6,56),5 (0,45) 4,6 (5,54) 202 (7,97) M8,5 (0,45) 64 (2,52) 64 (2,52) 62,5 (2,46) 62,5 (2,46) 65 (2,57) 48 (,89) 0 (3,98) 48 (,89) Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under Technical Data. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products where applicable. 2/99 N/** 5.4.89.05