Installation and Operating Instructions

Similar documents
Installation and Operating Instructions

Safety Switches with Separate Actuator SKC

Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications.

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Safety switches for hinged doors

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Safety switches with separate actuator

Safety switches with separate actuator

FL series position switches

Solenoid interlocks AZM 415 range. 134 Schmersal 29,5 6,5 24,7. 8,6 Pg 13,5 46,5 24,5

Position switches FC series

Position switches FR series

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Technical data. Standards: IEC/EN BG-GS-ET-15

Position switches FR series

Ordering details. Approval. Classification. Global Properties :18:33h. Solenoid interlock / AZM 161

Safety switches for hinges

Safety switches with solenoid and separate actuator

AZM 161SK 12/12RKED/TU 024

Standard Rope Pull Switches. With and Without Latching Function SIEM2 SID SIN SGC SI88. The field of application for these rope pull switches includes

Technical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19

Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the :

Operating instructions Solenoid interlock EX-AZM About this document. Content

Safety switches for hinged doors

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

An Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Position switches FD series

Safety rope switches with reset for emergency stop

Safety rope switch with reset for emergency stop

AF40... AF96 3-pole contactors Technical data

Safety door-handle system STS

Safety rope switch without reset for simple stop

LK Position Switches TECHNICAL DATASHEET.

3SE3 1 SIGUARD Position Switches

EStrong-series Emergency Stop

Safety switches with solenoid and separate actuator

Safety switches / Position switches / Command devices

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

HS5D Miniature Interlock Switches

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing

Switches with manual reset

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

3SE3 2 SIGUARD Position Switches

HIGH VOLTAGE TEF 1060 HV ENCLOSURE WITH A-BLOCK SOLUTIONS USER MANUAL

Safety Switches Series 8537

Single foot switches PX and PA series

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

HS6B Series Subminiature Interlock Switch

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

SG-B1 SERIES / SG-A1 SERIES

HS5D Miniature Interlock Switches

LR-LX-LK-LW Safety Switches with separate actuator

SERIES Z/T236. Safety-Rated, Positive-Break Miniature DIN Limit Switches. Features & Benefits. Description. Typical Applications ORDERING GUIDE

BETA Switching Switches and Light Indicators

SERIES AZM170. Solenoid-Latching Machine Guard Safety Interlock Switch. Features & Benefits. Description. Typical Applications

Prewired position switches FF series

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Safety-door Switch. Ordering Information

Online data sheet. i15-em0123 Lock i15 Lock SAFETY LOCKING DEVICES

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66

MS General Information Extended Product Type: MS

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Single foot switches - PX and PA series

ASL09..S 3-pole Contactors - Spring Terminals

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

Technical data. Standards: IEC/EN , EN ISO , IEC 61508, IEC

HS1C Interlock Switches with Solenoid

Position Switches Series 8070/2

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

Limit Switch - Prewired Type Metal Body

Operating instructions Safety foot switches T.FH UEDR.. 1. About this document. Content

Operating instructions Solenoid interlock AZM /.. 1. About this document. Content

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

TAE pole Contactors

Operating instructions Pull-wire emergency-stop switches EX-ZQ About this document. Content

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

Limit Switches - Limit Type Plastic Body IP65

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

Limit Switches - Limit Type Plastic Body IP65

HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key.

Door Interlock Switches

Position Switches Series 8060/2

MKey9-series Safety Interlock Switch with Guard Locking

Prewired position switches FF series

HS1L Interlock Switches with Solenoid

Standard Interlock Safety Switches

Single foot switches PX and PA series

Hinged Safety Door Switch

Transcription:

Plastic encased safety interlocking switch Type PSEN me4 Intended use The plastic encased safety switches PSEN me4 with separate actuator are suitable for the mounting on safety guards. They are designated to trigger switching operations in control circuits. Function If the safety guard is opened the contact(s) with forced disconnection contacts get opened). will break the safety control circuit (safety Safety instructions Improper installation or manipulation of the safety switch renders the personal protection function useless and can cause serious injury or accidental death. In order to maintain the maximum level of safety, always order and use actuators together with the correct safety switches. Dimensions [mm] Actuator PSEN me4as Date of issue: 31.01.2005 / Page 1 of 5

Fixed positioning for safety applications (M5) Minimum radii reference to a point of rotation on enclosure top edge S 0 Installation Installation by trained and qualified personnel only! To mount the switch gear 2 screws M5 shall be used. Actuator PSEN me4as: The user shall make sure that the actuator is form-fit mounted. The actuator mounting should not be solvable with simple tools. For a tamperproof mounting use one-way screws of M 4X8 size. The switch and the actuator shall be aligned during installation in such a way that even after multiple actuations of the safety guard no lateral forces affect the actuator head. The mounting position is any desired but shall support inspection and replacement if necessary by qualified personnel. Choose such a mounting position that no foreign parts seep into the opening of the actuating device. The rated degree of protection (IP-Code) of the switch applies only with closed cover lid and when an at least evenly matched cable gland with adequate cable is used. The switches shall not be used as mechanical end stop. Date of issue: 31.01.2005 / Page 2 of 5

The safety switch shall not be used as mechanical end stop! 4 different directions of actuation by turning the cap from 0 to 270 : 1. draw clasp out 2. turn actuator head 3. press-on clasp Cover for unused entry Position of mechanical stop adjustable (not supplied with safety switch) Actuating forces (Extraction force): Standard = 10 N PSEN me4.01, PSEN me4.11, PSEN me4.21 = 50 N Connecting the cable: Connection type: 2 or 4 screw connectors M3,5 or 6 screw connectors M3 Conductor cross section: single core 0,5-1,5 mm²/litz wire with connector sleeve 0,5-1,5 mm² Electrical connection The electrical connection shall only be carried out by trained and qualified personnel! The electrical contacts of switches PSEN me4, PSEN me4.01, PSEN me4.1 and PSEN me4.11 feature 4 screw terminals M3,5. Tightening torque M = 0,8 Nm. The electrical contacts of switches PSEN me4.2 and PSEN me4.21 feature 6 screw terminals M3. Tightening torque M = 0,6 Nm. The connection requires a stranded wire with ferrule or a solid wire with a cross section of 0,5 1,5 mm². For safety circuits acc. EN 60204 use the normally closed contact(s) (N.C.) only. Date of issue: 31.01.2005 / Page 3 of 5

PSEN me4 PSEN me4.1 PSEN me4.2 Electrical data PSEN me4.01 PSEN me4.11 PSEN me4.21 Switching function 1 NO/1 NC (Zb) 2 NC (Zb) 1 NO/2 NC (Zb) Switch symbol Rated insulation voltage U i 250 V AC 250 V AC 400 V AC Conventional thermal current I the 10 A 10 A 5 A Utilization category acc. IEC/EN 60947-5-1 240 V/3A 240 V/3 A 240 V/1,5 A Type of short-circuit protection 10 A gl/gg 6 A gl/gg 6 A gl/gg Melting fuse acc. IEC/EN 60947-5-1, annex K Forced disconnection (N.C.) IEC/EN 60947-5-1 Degree of protection II, protective insulation Mechanical data Enclosure Cover Ambient air temperature Cable entry Protection class Weight Thermoplastic, glass fiber reinforced (UL94-V0) Thermoplastic, glass fiber reinforced (UL94-V0) -30 C to +80 C, -22 F to +176 F 1 x M20x1,5 IP65 acc. EN 60529; DIN VDE 0470 T1 0,13 kg Actuating device Actuator Actuating radius Extraction force Mechanical life Mechanical life, extended actuation force Switching frequency 4AS Separate actuator (St stainless) 150 mm Standard 10 N PSEN me4.01, PSEN me4.11, PSEN me4.21 50 N 1 x 10 6 switching cycles 1 x 10 5 switching cycles 30/minute Standards VDE 0660 T100, DIN EN 60947-1, IEC 60947-1 VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1 GS-ET-15 EU-Conformity Approvals BG (applied for) UL/CSA A300 (applied for) for PSEN me4, PSEN me4.01, PSEN me4.1, PSEN me4.11 UL/CSA B300 (applied for) for PSEN me4.2, PSEN me4.21 Date of issue: 31.01.2005 / Page 4 of 5

Start-up Mechanical function test: Actuate the safety guard und check the proper switching function. Electrical function test in the safety control circuit: - Opening the safety guard shall break off the energy of the drive. - The drive shall only be energized when the safety guard is in its closed position. Maintenance / Inspection The switching device is maintenance-free. For trouble-free operation and a long service life the device should be inspected regularly. Ensure that: - all components are secure and tight - switching functions operate properly - all sealing gaskets are in proper condition - the components show no signs of tear and wear. If defects are detected the complete switching device and the actuator have to be replaced. Liability disclaimer By breach of the given instructions (concerning the intended use, the safety instructions, the installation and connection through qualified personnel and the testing of the safety function) any liability expires. Date of issue: 31.01.2005 / Page 5 of 5