No: Revision Operation & maintenance manual. BRAVO SLURRY PUMPS

Similar documents
& AL RC-SERIES GB HSC 09-W13 Edition 5. T +31 (0) F +31 (0)

& AL RW-SERIES GB HSC 08-W36 Edition 4. T +31 (0) F +31 (0)

Dry installed pump type LANDY BTP.

Operation & Maintenance Manual

Operation & Maintenance Manual

Operation & Maintenance Manual

SUBMERSIBLE PUMP HSE RANGE

Operation & Maintenance Manual

SUBMERSIBLE PUMP HSE RANGE

SUBMERSIBLE WATER PUMP

IM205 ITT. Wastewater. Vortex Series. Installation, Operation and Maintenance Instructions. Engineered for life

OPERATION & MAINTENANCE INSTRUCTIONS

Installation & Operating Manual

SUBMERSIBLE WATER PUMPS

SUBMERSIBLE WATER PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. CSE400A. Part No iss 2

Submersible Pump Instructions. Safety Instructions

Operation & Maintenance Manual

SUBMERSIBLE PUMPS HSE RANGE OPERATING & MAINTENANCE INSTRUCTIONS GC0514

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

SUBMERSIBLE DIRTY WATER PUMP

OPERATION & MAINTENANCE INSTRUCTIONS

No: En Revision Parts List. Matador O-RING KIT BASIC REPAIR KIT B_8106_180_expl_view

DRENOX SUBMERSIBLE SUMP PUMPS FOR DRAINING CLEAR WATER. Usage limitations

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

Operation Manual Model: PPSSS Submersible Slurry Pump

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

SUBMERSIBLE WATER PUMP

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105

Rated output 5,6 kw 5,6 kw. Max power consumption 6,7 kw 6,7 kw. Shaft speed 2890 RPM 2890 RPM

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

SUBMERSIBLE WATER PUMP

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories.

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

OPERATING INSTRUCTIONS. ASTRO HOIST Type E89-CTO

Instruction Manual. * We reserve the right to amend specification without prior notice.

Instruction Manual. * We reserve the right to amend specification without prior notice.

Instruction Manual. Sewage lifting station compli 300

Service instructions. MS6 3.7 kw - 30 kw. 50/60 Hz 3~

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: , LS1010

L-SERIES PUMPS. Operating Manual. Includes Pumps: L-305 L PONDS

WEDA PUMP. Submersible Water Pump WP300 INSTRUCTIONS & SPARE PARTS CATALOGUE WP300_ ENG_1

Thank you for selecting the GD submersible grinder pump.

Unilift KP 150, KP 250, KP 350

No: En Revision Parts List. MINETTE O-RING KIT BASIC REPAIR KIT F_8102_171_expl_view

Parts List. MAJOR

GD series Submersible Grinder Pump

Medium and high pressure pumps

Matala. VersiFlow Series. Instruction and Maintenance Manual

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

Heavy duty submersible slurry pumps

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ,

No: En Revision Parts List. MINEX O-RING KIT BASIC REPAIR KIT E_8101_171_expl_view

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Table 3. Pumping Range. 6 in cm. 8 in cm. 16 in cm. 6 in cm. 14 in cm. 18 in cm.

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories.

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

PL Submersible, Semi-Vortex, Water Feature Pump

Welcome to Grindex Pump handbook! With this handbook we want to share some of our wide experience in pumping with submersible pumps.

Parts List. MINOR

Heavy duty slurry pumps

Revision 1.0 Parts List Master

The school consists of technical articles, intended to help pump users with common matters in pumping with submersible pumps.

PURE SINE WAVE DC TO AC POWER INVERTER

Installation, Maintenance and Operation manual 4 Submersible sand fighter pump. Type: SSFP - Series

GeyserMax-Flow Series

Installation, Operation, and Maintenance Manual

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

77014 / Automatic Users Manual. Carefully read this entire Instruction Manual before using this product

COOKSON OWNER'S MANUAL

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230

Operating instructions for PXFLOW sewage pumps

Heavy duty slurry pumps

Ni-HARD SUBMERSIBLE PUMP

Revision 2.0 Parts List Master

Installation, Operation, and Maintenance Manual

Submersible Turbine Pump (Volute) STM type (T, TU, and TU3) SSTM type (TUA)

Submersible Effluent Pump

Submersible Tank Pump

SUBMERSIBLE MAGNETIC DRIVE PUMP SUBMERSIBLE YD-5002GWN. INSTRUCTION MANUAL Version: (for U.S.A)

Welcome to Grindex Pump handbook! With this handbook we want to share some of our wide experience in pumping with submersible pumps.

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Manual PN: Rev 01. Otterbine Barebo Inc. Fractional Series 50Hz Installation Manual

Installation Manual. Omnivore Grinder Pump Retrofit Unit LSG202-RE. LSGX202-RE 2Hp, V, 1 phase, Automatic LSG202-REX

Installation & Operating Manual

garden PUMP kit 1 Depth A & B must be less than 9m Max Depth C must be less than 9m Max GardenPump Inst 6/11/07 12:52 Page 1

Installation, Operation and Maintenance Manual Stancor SE, SV, SS & SC Series Pumps

Installation, Operation, and Maintenance Manual

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

6 Litre Oil-Less Air Compressor

Operating Instructions

ESE Series Cast Iron Sewage Pumps

PV4 - PIV6. Submersible multistage centrifugal electro-pumps. Installation and maintenance. This manual is to be given to the end user

TPAK Series COOLANT PUMP

SPECIFY THE RIGHT HOT OIL PUMP FOR YOUR APPLICATION

Installation, Operation, and Maintenance Manual

GRUNDFOS INSTRUCTIONS MTC. Installation and operating instructions

SELF PRIMING CHEMICAL SERVICE PUMPS

Transcription:

No: 90 072 01 Revision 1 2005.07 Operation & maintenance manual SLURRY PUMPS www.grindex.com BRAVO

Your choice of a submersible pump from Grindex has given you a pump that will serve you well for a long time to come. Grindex pumps are designed and built for continuous use in hostile working conditions. he service life of your Grindex pump will depend to some extent on you. If you want optimal service for the longest possible time it s important that you familiarize yourself with the advice and directions given in these instructions. With cordial greetings GRINDEX echnical Manager Congratulations on a sound choice! his GRINDEX pump has no motor protector. he pump must be supplied with an external Motor starter fitted in the end of the pump cable. Following Motor starters can be used: On/Off switch and thermal overload circuit breaker. On/Off switch and thermal overload magnetic circuit breaker. For connection of motor thermal contacts circuit a Motor starter with following features must be used: On/Off switch, thermal overload magnetic circuit breaker and integrated thermal monitoring system. he thermal overload circuit breaker must conform to the rated current and motor input power of actual pump. After connection to power, always check that direction of rotation of motor is correct! able of contents Page Installation and use...3 How to read the data plates...3 his is how to install your pump...4 his is how the pump must stand in the sump...4 Hose...5 Cable and power supply...5 Permanent installation...6 Respect limitations...6 Safety and environment...7 Main parts...8 Maintenance...8 Cable entry...9 Checking the oil level...10 Oil change...11 Motor housing...12 rouble shooting...13 Pump cable connectors...14 Wiring diagrams...15 2 (16) No: 90 072 01 Rev 1 2005.07

Installation and use Read this manual before installing the pump. Check that you have received the right type of pump and that the pump data corresponds with what you ordered. he simplest way to do this is to check the particulars on the data plate, which you will find on the pump. he rated voltage, rated current and maximum power consumption are particularly important. On the bases of these particulars you should check that you have the right power supply, motor controller and fuse arrangement. How to read the data plates Model Pump type No. Rated voltage Rated current Number of phases and frequency Before use see operators manual Box 538 S-136 25 Haninge SWEDEN www.grindex.com YPE U I Ø 3 ~ c/s V A Hz Pmax Hmax Qmax 20m No kg kw m l/s MADE IN HE NEHERLANDS Serial No. Weight Maximum power consumption Maximum pressure head Maximum flow capacity Maximum submersion depth Rotation Start reaction his pump must be used with external motor protection in accordance with technical data If you need further technical data please refer to the relevant data sheets. Attention! Before the pump is installed in the sump check the direction of rotation. Start reaction is counter clockwise and rotation of motor is clock-wise when the pump is viewed from top. See arrows on data plate of pump. WARNING! he start reaction of motor can be powerful! Safety Precautions. All electrical work should be performed by an authorized electrician. Follow local safety regulations and observe recommended safety precautions. All electrical equipment must be earthed. his applies to both pump and equipment. Before starting work on the pump, make sure that the pump is isolated from the power supply and can not be energized. Be sure to disconnect the power supply before attempting inspection, as pump may start automatically. Respect limitations, see page 6. 3 (16) No: 90 072 01 Rev 1 2005.07

his is how to install your pump Connect the pump to power. If rotation of motor is wrong shift two phases. (Shift two phases in the power supply terminal or in the CEE plug, or turn the knob on phase shifter). If the pump still doesn t start: Call a qualified electrician and ask him to check the mains and the junctions. 2 3 Except for the pump the following components are necessary: 1. Hose connection, which is fastened to the pump 2. Flexible hose 3. Lifting chain 1 WARNING! Swich off the current before installing or moving the pump. Make sure that suspension brackets, shackles and their means of attachment are undamaged. Before installing the pump attach a chain or wire to the suspension bracket and use it to lower the pump into the sump and lift it out again. WARNING! Never use the cable for lifting or lowering the pump. Checkpoints before operating: Do not let the pump bury itself in the mud. Do not leave a large loop of the cable in the sump, as the pump may eventually damage it. Check that the motor is adequately cooled. he motorhousing should be at least 2/3 submerged for continuous operation at full load (see Hmin.1 Fig.) It is good practice, whenever possible, to keep the motorhousing completely under water. For choosing the discharge, pipe/hose inner diameter to avoid sedimentation, the following minimum critical velocities can be used as a guide. Contaminated water containing fine sand, the velocity should exceed 2,5 m/s. Water and larger solids in suspension, the velocity should exceed 3,5 m/s. his is how the pump must stand in the sump o attain maximum capacity and to prevent excessive wear, the pump should be positioned in one of the following ways so that it doesn t burrow itself into sand or clay. Place the pump on a firm base which prevents it from sinking down or tilt over. Hang the pump freely by a chain or wire 4 (16) No: 90 072 01 Rev 1 2005.07

Hose Kinks in the hose will reduce the pump capacity. Cable and power supply Having the right cable and handling it properly will save you from many malfunctions. WARNING! If the cable sheath is damaged and the cable is lowered into the water, water may enter into the junction chamber of the pump. If the cable is damaged it has to be replaced. If your cable is too long, don t coil it up, since this could cause voltage drop. If you use an extension cable, see that it is correctly dimensioned. he longer the cable, the greater the conductor cross-section you will need in order to avoid voltage drop. Strong sunlight can also cause voltage drops. If you re drawing your power from your own generator it s important that it is correctly dimensioned. Do not use the Generator setting Auto idle function. WARNING! reat the electrical equipment with care. his will prevent both malfunctions and accidents. Make sure that junctions don t get into the water. Don t lay the starting equipment directly on the ground. If persons are likely to come into physical contact with the pump or pumped media (liquid), for example on construction sites or farms etc, the earthed (grounded) socket must have an additional earth- (ground-) fault protection device (GFI) connected. When pumping near a lake (beaches, ponds and fountains etc) a safety distance of at least 20 meters (65ft) between the person and the pump is applicable. 5 (16) No: 90 072 01 Rev 1 2005.07

Permanent installation Respect limitations he pump must not be submerged to more than 20 metres/65 feet. IP-68. he temperature of the medium must not exceed 40 C/103 F. he ph-value should be between 4 and 10. he voltage drop in operation must not exceed 5 %. Maximum numbers of starts per hour: 15 evenly spread. Maximum cable lengths. Excessively long cables cause voltage drops that can result in malfunctions. By using a cable of greater conductor crosssection you reduce the voltage drop and can therefore increase the cable length. Pressure losses. Long or unnecessarily small-bore hoses give substantial pressure losses. 1. Submersible slurry pump 2. Overflow alarm 3. Level control equipment with float switches 4. Hose 5. Non-return valve 6. Lifting tackle WARNING! he pump should not be used in explosive or fire-risk conditions or for pumping inflammable liquids. In order to decide what pump would be best for a permanent installation you will need to know the following: ype of medium (sludge, abrasive, corrosive, etc.) Inflow of liquid Head Desired pump capacity Size of the pump sump Size and length of discharge pipe, number of bends and valves, etc., for calculation of WARNING! Don t go near rotating parts of the pump. 6 (16) No: 90 072 01 Rev 1 2005.07

Safety and environment In this manual General warning Danger! On the pump Danger of physical injury Rotating parts! Electrical hazard! Electrical hazard! Danger of physical injury Rotating parts! EC-conformity symbol General safety instructions he pumps must be secured and prevented from rolling during transportation. Approved equipment must be used for lifting and lowering the pump. Only trained and authorized personnel may install and maintain the pump after carefully reading this manual. Only use the pump for its intended purpose and under the regulated circumstances. Don t go near rotating parts. Clean the pump before maintenance and inspection. Observe the local regulations when working with agressive, corrosive, toxic, and/or chemicals. Never remove safety signs, keep them clean. Always connect to a protective grounded circuit. Before maintenance and inspection always disconnect the pump from the power supply. Use a proper hoist for lifting and handling the pump. Do not leave a large loop of cable in the sump, as the pump may eventually damage it. Never drop the loose cable end in water. he water may enter the cable and finally enter the motorhousing, eventually causing motor failure. Environment Parts which are replaced during repair, maintenance or renewal, could contain materials which could be harmful to the environment. Please take care in the disposal of these parts. Do this in accordance with the local environmental regulations. 7 (16) No: 90 072 01 Rev 1 2005.07

Main parts 1 Pump casing 2 Impeller 3 Agitator 4 Discharge outlet 5 Motor housing 6 Rotor unit 7 Stator 8 Shaft 9 Bearings 10 Mechanical shaft seal (2x) 11 Oil chamber 12 Oil screw 13 Cable entry 14 Cable 15 Cover 16 Main cover 17 erminal board Maintenance Always disconnect the pump from the electical power before inspection or disassembly. he motor housing can be hot when the pump is just switched off. Ensure that the pump is fully supported to prevent it from falling over! Check the oil every 6 months or 500 running hours If there is more than a few cm3 water in the oil chamber, contact your dealer. Change the oil every year or when it is no longer transparant. 8 (16) No: 90 072 01 Rev 1 2005.07

Cable entry When the pump has been in use for a long time, the compression of the rubber cable seal might be diminished, which can cause leakage. By screwing-in the cable entry the seal will be retensioned. Bravo 20, 30, 40 Unscrew the 2 hexagon socket screws (1). Remove the cable clamp (2). urn the hexagon head of the entry (3) clockwise, using the right tool, so far that it is possible to replace the cable clamp again. Screw-in the 2 hexagon socket screws (1). It is possible that your pump is fitted with only 1 cable. Bravo 50, 60 Unscrew the 4 hexagon socket screws (1) from the outer cable entries. Remove the cable clamps (2). urn the hexagon heads of the entry clockwise, using the right tool, so far that it is possible to replace the cable clamps again. Screw-in the 4 hexagon socket screws (1). It is possible that your pump is fitted with only 1 cable. 9 (16) No: 90 072 01 Rev 1 2005.07

Checking the oil level Bravo 20, 30, 40 Put the pump in a horizontal position so that 2 hexagon socket screws are on top and one at the bottom. Unscrew the level plug (1) and the vent plug (2). he oil level should be at the lower side of the openings (see drawing). By turning the pump a bit this should be visible. If not so, fill up to the right level. Always use the right kind of oil! Bravo 50, 60 Put the pump in a vertical position. Unscrew the M20 oil pug (1) which can be found at the opposite side of the cable entry box. he oil level should be at the lower side of the opening. If not so, fill up to the right level. Always use the right kind of oil! 10 (16) No: 90 072 01 Rev 1 2005.07

Oil change Bravo 20, 30, 40 Put the pump in a horizontal position so that the drain plug (3) is at the bottom. Remove the vent plugs (1) and (2). Put a receiving bin underneath the drain plug. Remove the plug and drain the oil. Replace the drain plug. Refill the oilhousing. he oil level should be at the lower side of the openings. Replace the plugs. Bravo 50, 60 Put the pump in a horizontal position so that the drain plug (M20) is at the bottom. Remove the vent plugs (1) and (2). Put a receiving bin underneath the drain plug. Remove the plug and drain the oil. Replace the drain plug (3). Refill the oilhousing through the opening (1). he oil level should be at the lower side of the opening. Note! Collection, storage and removal of the oil should be done according to the regulations of the local authorities. When necessary replace the sealing rings. Always use the right kind of oil! See spare parts list. 11 (16) No: 90 072 01 Rev 1 2005.07

Motor housing Bravo 20, 30, 40 Place the pump in a vertical position and remove the 4 hexagon socket screws of the motorhousing. Lift the motor unit very carefully a few cm s, see fig. If water is present this will come out this way. A small amount of water, due to condensation, is permissible. More water is an indication of leakage of the construction. Oil is an indication of seal failure between motorhousing and oil chamber. If so, contact your dealer. Bravo 50, 60 Place the pump in a vertical position and remove the 4 hexagon socket screws (1) of the cable entry box cover (2) and check the entry box. Remove the 4 hexagon socket screws (1) of the cable entry box and pull the cable entry box a few cm s from the pump. If water is present this will come out this way. A small amount of water, due to condensation, is permissible. More water is an indication of leakage of the construction. Oil is an indication of seal failure between motorhousing and oil chamber. If so, contact your dealer. 12 (16) No: 90 072 01 Rev 1 2005.07

rouble shooting Safety When working on the motor, make sure that the power is switched off. When starting the pump, ensure nobody goes near rotating parts. Attention! When working on the pump, make sure it cannot start unexpectedly! Only qualified electricians may do the electrical work. Observe local electrical and safety regulations! rouble shooting list Problem Pump does not start Possible cause No voltage on motor terminals Required action Check power supply Checkpoints No power Main isolator switch Fuses Check motor protection Earth leakage relay Motor protection relay Motor temperature Motor failure Check motor wiring Continuity and isolation Phase resistance Pump starts and stops repeatedly Fault in power supply Check power supply Low voltage Not all 3 phases available Setting of motor protection Motor overloaded Check pump Wrong direction of rotation Impeller blocked Protection in automatic reset mode Motor overheated Check cooling Check motor Continuity and isolation Fuses Current too high Fault in power supply Check power supply Low voltage Impeller blocked Pump failure Check pump Visc. or spec. gravity too high Wrong direction of rotation Pump runs but no flow or too low flow Clogging or air lock Check dicharge and coupling Discharge obstructed Valve fully or partly closed Air pocket in pump or discharge Coupling leaks Pump failure Check pump Impeller or volute blocked Pump is sucking to much air Worn or broken impeller Fault in power supply Check power supply Controlpanel Fuses Low voltage oo low capacity Check discharge Discharge obstructed Valve fully or partly closed Air pocket 13 (16) No: 90 072 01 Rev 1 2005.07

Pump cable connectors DOL W1 V2 W2 U1 U2 V1 1 2 3 4 5 6 G/Y 1 U 2 V 3 W 4 5 6 G/Y W1 V2 W2 U1 U2 V1 G/Y U V W 3x6mm2+3x1.5mm2 7x2.5mm2 3x6mm2+3x1.5mm2 W2 U1 U2 V1 V2 W1 1 2 3 4 5 6 G/Y 7x2.5mm2 1 2 3 4 5 6 G/Y U1 V1 W1 W2 U2 V2 Y / D V2 W2 (x) U2 W2 U1 3x6mm2+3x1.5mm2/ 3x16mm2+3x2.5mm2 U1 V1 W1 U2 V1 V2 W1 G/Y G/Y W2 U2 V2 W2 G/Y V2 (x) U2 4x2.5mm2 4x6mm2/ 4x16mm2 =brown =blue/grey =black GN/YE=green/yellow 1-2-3=U1-V1-W1 4-5-6=W2-U2-V2 C1=thermal contact C2=thermal contact C3=not used A=ground = he 4th conductor is split up in 3 parts, hese 3 parts should be used as ground core. thay have the same total cross section area as the none split core X=Connect the cable leads in GRINDEX external starter according to this sequence. Bravo 20,30,40 DOL Bravo 20,30,40 Y/D Bravo 50,60 14 (16) No: 90 072 01 Rev 1 2005.07

Wiring diagrams NOE he overcurrent protection should be set to AUO. he tripping current should be max. the rated current of the pump. Note that the scales for direct online and star/delta are different. he Y/D overload relay should be set at phase current = 0,58 x line current. he Y/D time relay should be set at 3s. 15 (16) No: 90 072 01 Rev 1 2005.07

Notes Grindex AB Box 538 SE-136 25 Haninge Sweden el:+46 8 606 66 00 Fax:+46 8 745 16 06 e-mail: grindex@grindex.com www.grindex.com 16 (16) No: 90 072 01 Rev 1 2005.07