VCM LAMINAR FLOW HOOD VERTICAL

Similar documents
EXT DUCTLESS FUME HOOD

EXT HEPA/CARBON FUME HOOD

CLEAN AIR WORKSTATION REVERSE FLOW. Installation and Operations Manual

TXH TOTAL EXHAUST HOOD. Installation and Operations Manual

FUME HOOD. Installation and Operations Manual

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

Laminar flow Cabinet Vertical BBS-V500. User Manual

Model G14SD Vapor Management System

BIOLOGICAL SAFETY CABINET

BIOLOGICAL SAFETY CABINET

Biological Safety Cabinet Class II A2

BIOLOGICAL SAFETY CABINET

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

Arm Fume Hood FHA-1. Operation Manual PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

READ AND SAVE THESE INSTRUCTIONS. Air Boss MP600M Vertical Air Flow Mist Precipitator Industrial Applications. TRION

A. Each cabinet must be constructed and installed in accordance with EN12469:2000.

SPECIAL REVERSE HORIZONTAL FLOW ENCLOSURE OPERATING AND MAINTENANCE MANUAL. Issue No: 1

Biological Safety Cabinet

Further information: Berriman Associates Model 850P.2 Owners Manual

Instruction Manual. Fudge Puppy Display Case

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

VLF-797 CLEAN BENCH INSTALLATION AND SERVICE MANUAL Volt Model Volt Model

CLASS II BIOSAFETY CABINET

OPERATION and MAINTENANCE INSTRUCTION MANUAL

Installer s Manual. PCO/UV N-Duct Model

After installing the HEPA filters the discharge air should be monitored to ensure proper filtering efficiency. HEPA Filters

FlexChem Model 404 Rotating Oven

Heated Bakery Merchandiser Series. Series: WBC Operation Manual

SUBMERSIBLE MINI-PUMP

Instruction Manual AVTM for. Strip Chart Recorder Catalog Nos and

Sentinel Enteral Feeding Pump. Model: S-1000-SI. Operating Manual

HARDWARE KIT INSTALLATION GLOVES

FA1 Series Air Filtration System. Operations Manual

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-17B & AEU-17BV2 Implant / Surgery Systems

Advanced PCO System. Installation Instructions & Consumer Information. Section I. Important Installer Information WARNINGS

FAN POWERED HEPA FILTER UNIT

PCR 6. Operators Manual. Vertical Laminar Airflow Cabinet with U.V. Sterilisation. Issue 05 September 2013

INSTALLATION, MAINTENANCE & OPERATION GUIDE. MODEL Sanuvair S300 WHOLE HOUSE HEPA/UV AIR PURIFIER. ITEM # Sanuvair S V EN

SafeFAST Elite. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Cytotoxic Safety Cabinets ENVAIR eco safe Plus

AXD 530 MicroManometer

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

MODEL 950C-NP-UV Installation and Owners Manual

Techlab - Matériaux de Référence certifiés et Equipements de Laboratoire -

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

MODEL FA1 Mini Air Filtration System. Operations Manual

READ AND SAVE THESE INSTRUCTIONS. ComfortBreeze UV360-1 SYSTEM 24V Ultra-Violet Air Cleaner. Trion

FE-WS6 Downflow Ductless Workstation. Operator s Manual

LIGHTSTICK / LIGHTSTICK PLUS Germicidal Ultraviolet Light

Installation & Maintenance of the Fresh-Aire UV Airborne Duct System for Commercial HVAC Systems. Parts Included. Optional Parts

WS-Series. Operating Instructions. Pulse DC End Area Coils. Drilco Style WS-Series Coils 1. E s t a b l i s h e d WS-14 WS-12 WS-10 WS-8

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-707A & AEU-707AV2 Implant / Surgery Systems

SafeFAST Top. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

WARNING ATTENTION. Please read this information carefully before operating your safe.

Automatic Emergency Light

INSTALLATION INSTRUCTIONS

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

Model 700 Microarray Oven

MODEL MC1500 Installation and Operation Manual Important:

Fiber Optic Illuminator. Model 21AC Model 21DC

PRODUCT CATALOG CLASS II BIOLOGICAL SAFETY CABINET.

Source Capture Air Purification System

Class II biological safety cabinets

Dispenser & Warmer RIC-1909 RIC-1909EXP

Hazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual

Stealth Power i-tilt

Model: UV-16R/24 READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

IMPORTANT: SAFETY INSTRUCTIONS Important: Instructions de securité

LAMINAR FLOW HORIZONTAL FLOW BENCH (LF) OPERATION & MAINTENANCE MANUAL

ULTRAMAX AIR DISINFECTION SYSTEMS OWNERS GUIDE

Cambro Camtherm OWNER S MANUAL. Plate Heater.

UV-AIRE AIR PURIFYING SYSTEM

Mania EF1 user manual

Automatic Burnout Furnaces 115 to 230-volt Models OPERATOR S MANUAL

BioPROtect III. and BioPROtect III Jr. Class II Style Walk-In Clean Air and Containment Enclosures.

Back-Up Sensor System

Laboratory Series. Ultraviolet Ozone Destruct System Installation, Operation and Maintenance Manual. One Source for All Your UV Needs!

PHANTOM (PH10 and PH12) COMMERCIAL AND INDUSTRIAL SERIES

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

MINISTICK TM UV Germicidal Ultraviolet Light

Safety, Installation and Service Manual Models 1952, 1953 & 1972

IV STANDS. Assembly, Usage and Maintenance INSTRUCTION MANUAL

HERCULES II DC OWNER S MANUAL HERCULES II DC RESIDENTIAL & COMMERCIAL

FD Conveyor for FD 260 Tabber

MODEL FA5 Air Filtration System. Operations Manual

Stainless Steel Kick Bucket and Stand

Envair Lab SCS Evo Comfort+ Class II Microbiological Safety Cabinets

AIM LED LIGHT (wall mount)

Helios. 24 Light 240 Volt Controller. PRODUCT # Instruction Manual.

Installation & Operation Manual Chef Base

materials and workmanship for 2 years. Should the centrifuge require warranty or Phone: or Fax:

BSC-1100IIA2-X is designed to meet the operating principles:

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com BVX-100. Fume Extraction System _B

MC2500. Installation and Operation Manual

Series 301. Horizontal Laminar Flow Clean Bench. C l e a n B e n c h e s. s o l u t i o n s. Series 301 Horizontal Laminar Flow Clean Bench

AMCON AUTOMATIC CHART PROJECTOR USER S MANUAL EQ-6002

3-in-1 Electric Jack, Impact Wrench & Air Compressor

Exterior Digital Load Scale 201-EDG-01(B) Installation and Operation Manual Please read carefully before installation

Transcription:

VCM LAMINAR FLOW HOOD VERTICAL METAL Installation and Operations Manual

VCM LAMINAR FLOW HOOD VERTICAL Installation and Operations Manual Revision: 04-Oct-17 Page 2 of 22

VCM LAMINAR FLOW HOOD VERTICAL Installation and Operations Manual Revision: 04-Oct-17 Page 3 of 22 MODELS COVERED VCM-400 (4 ) VCM-600 (6 ) TABLE OF CONTENTS MODELS COVERED... 3 1. APPLICATIONS & WORKING ENVIRONMENT... 4 2. SHIPPING... 5 3. INSTALLATION... 5 4. PACKING LIST... 7 5. PARTS IDENTIFICATION... 8 6. INITIAL START UP... 9 7. ADJUSTMENTS... 9 8. TECHNICAL PARAMETERS... 11 9. REPLACEMENT PARTS... 11 10. OPERATION OF THE HOOD... 11 11. AIR FLOW DIAGRAM... 14 12. CLOCK ADJUSTMENT... 14 13. MAINTENANCE... 15 14. ELECTRICAL WIRING DIAGRAM... 16 15. TROUBLESHOOTING... 17 16. FAN AND HEPA FILTER REPLACEMENT... 19 17. NOTES... 20 18. SERVICE/MAINTENANCE NOTES... 21 19. WARRANTY... 22

VCM LAMINAR FLOW HOOD VERTICAL Installation and Operations Manual Revision: 04-Oct-17 Page 4 of 22 Thank you for choosing a Design Filtration Microzone VCM Laminar Flow Hood. With proper care and maintenance, your cabinet will provide many years of service. This unit is designed to provide a particle-free work environment by filtering the air through a high efficiency particulate air filter; a HEPA filter. The cabinet is designed to operate under constant positive pressure in order to maintain the cleanest work environment possible within the work space itself. Please be sure to read this manual before operating your cabinet, as it contains important information to assist you in using your cabinet safely and to get the most out of its unique features. Important information should be filled in below and this manual kept on hand at all times for quick and easy reference, as well as a field reference for certifiers or service personnel. Laminar Flow Hood Information: Model Number: Serial Number: Date of Manufacture: Date of initial installation: For replacement parts, warranty information or any other inquiries, please contact Design Filtration Microzone at: Toll Free: 1-888-636-8609 or 1. APPLICATIONS & WORKING ENVIRONMENT This Laminar Flow Hood is designed to provide either a horizontal or vertical curtain of clean air over the interior working surface. It is used to maintain high levels of cleanliness for laboratory grade requirements whether used in the medical, electronic, bioscience, nuclear or life sciences industries. This equipment should only be used when the following conditions have been met: To be used indoors only Temperature of the room should be between 15ºC and 35ºC Relative humidity of the room should be <75% Air pressure range should be between 70kPa and 106kPa Power supply requirement: AC 115 V

VCM LAMINAR FLOW HOOD VERTICAL Installation and Operations Manual Revision: 04-Oct-17 Page 5 of 22 2. SHIPPING Design Filtration Microzone assembles and factory tests each unit prior to shipping. On occasion, damage can occur during the transportation of your new Laminar Flow Hood. You should inspect your unit for damage that may have been caused and report it immediately to your transportation company. All shipments are F.O.B. Design Filtration Microzone. All claims for damage due to shipping should be filed with the carrier. Design Filtration Microzone and its dealers are not responsible for shipping damages. Your Laminar Flow Hood has been factory tested and set for appropriate airflows, however all HEPA filtered equipment should be certified by a qualified technician prior to use. 3. INSTALLATION Prior to Installation Before installing your new Laminar Flow Hood please note: The base stand is on the top or back of the cabinet when packed for transport. It should be removed FIRST before installation. Then: Inspect the crate carefully for any exterior damage If the unit was transported during extreme temperatures, place the crate in heated/cooled area for 24 hours to allow all the components to come to room temperature Prepare and clean the area where the cabinet is to be installed During and after unpacking inspect the interior and exterior of the hood itself to be sure that it is free from damage before completing the installation Use the packing list (please see page 9) to be certain that all components are present, including all the necessary hardware Gather the tools required before beginning assembly and be sure you have read and understood all the instructions in this manual Location It is important that your new Laminar Flow Hood is installed correctly and in the best location possible. It should be located in such a way that the airflows within the cabinet will not be disturbed by overhead ventilation systems, doors that open and close frequently, or heavy traffic areas. Being located too close to any of these things will have a negative impact on the airflows within the cabinet. In order for the cabinet to run well, and for ease of service and maintenance, there should be no less than 15 cms (or 6 ) of clearance on all sides of the cabinet.

VCM LAMINAR FLOW HOOD VERTICAL Installation and Operations Manual Revision: 04-Oct-17 Page 6 of 22 STEP 1: Assemble the base stand using the hexagon bolt M10 (x10) flat washer (x10) and spring washer (x10) as shown below and tighten securely. The cabinet is connected with the positioning bolt T shape support Transverse bracing STEP 2: Once the head section has been placed onto the base stand, use M10 hexagon bolt, spring washer, flat washer and M10 hexagon nut to attach the head section to the base stand as shown below. Be sure to tighten all connections securely.

VCM LAMINAR FLOW HOOD VERTICAL Installation and Operations Manual Revision: 04-Oct-17 Page 7 of 22 Installation Notes The universal casters have leveling pads that can be adjusted to correct for uneven floors. Be sure the interior of the unit is entirely cleaned out of all packing materials, including any smaller fragments as they could damage the motor/ blower or HEPA filter. Check all connections, bolts, screws, etc that are inside the working area of the hood to be sure that nothing is loose. Install the fluorescent lamp and the UV light (if being used). UV bulbs should not be handled with bare hands, as residual oils can affect the intensity of the UV output. After installation, your certifier or DFMZ representative can assist with training and any questions you might have about the safe operation of your new laminar flow hood 4. PACKING LIST VCM-400 PACKING LIST Name Quantity Main Body 1 Base Stand 1 Fluorescent lamp (T5 28W) 1 UV lamp (T8 30W) 2 User Manual 1 Test Report 1 Hexagon bolt M10 55 3 flat washer x 10 + spring washer x 10 + M10 nut 2 Socket head wrench 1 VCM-600 PACKING LIST Name Quantity Main Body 1 Base Stand 1 Fluorescent lamp (T8 36W) 1 UV lamp (T8 40W) 2 User Manual 1 Test Report 1 Hexagon bolt M10 55 3 flat washer x 10 + spring washer x 10 + M10 nut 2 Socket head wrench 1

VCM LAMINAR FLOW HOOD VERTICAL Installation and Operations Manual Revision: 04-Oct-17 Page 8 of 22 5. PARTS IDENTIFICATION 1. Primary efficiency filter 7. Gas tap 2. Tubular motor - window 8. Deck plate 3. LCD display 9. UV lamp 4. Rocker switch 10. Socket 5. Fluorescent lamp 11. Base stand 6. Side window glass

VCM LAMINAR FLOW HOOD VERTICAL Installation and Operations Manual Revision: 04-Oct-17 Page 9 of 22 6. INITIAL START UP Connect the power supply. Switch power on using black toggle switch. Press the power button on the touchpad. Before beginning any work inside the cabinet, wipe down the interior work space with alcohol or other disinfectant, close the window all the way and turn on the UV lamp (if so equipped) for at least 30 minutes. If no UV lamp is installed, leave the window at working height following disinfection and allow the unit to run for at least 30 minutes. Upon the completion of work in the hood, always wipe the interior with a disinfectant, then close the window all the way and turn the UV lamp on for 30 minutes. After 30 minutes, turn the UV lamp off and power off the hood, leaving the window fully closed. UV lights should be tested on a regular basis. If the UV light is used regularly, we recommend replacing it each time the hood is certified to maintain maximum effectiveness. 7. ADJUSTMENTS 7.1 ALARM ADJUSTMENTS NEW FEATURE ON VCM UNITS VCM new functions: the low flow alarm and flow set point can be adjusted. After turning on the blower for 1 minute, if the air flow is lower than the alarm set point value, then the alarm function will trigger. Instructions: 1. Power off: No display, but power is still connected to the hood. Press for 5 seconds; then the display will show as in photo below. alarm set point value 2. Press to increase or decrease the alarm set point value. Range: 60 110 FPM

VCM LAMINAR FLOW HOOD VERTICAL Installation and Operations Manual Revision: 04-Oct-17 Page 10 of 22 3. Press the power button to save the set point and exit. Note: If there is an alarm, the only way to clear the alarm is to correct the airflow problem or to turn off the hood. 7.2 AIRFLOW ADJUSTMENTS Before beginning this section, confirm that no obstacles are present in the air lines from the differential sensor to the plenum. NOTE: THIS IS TO BE PERFORMED BY A QUALIFIED TECHNICIAN ONLY. 1. For the most accurate setting, ensure that the pre-filters are installed and the sash is fully opened. 2. Turn on the Main Power toggle switch. The display will momentarily illuminate and there will be an audible beep. DO NOT PRESS the red Power switch on the keypad. 3. Press the airflow buttons simultaneously and hold for 5 seconds. (See Control Panel Diagram on page 11.) The hood will start and the display will indicate a Speed Adjustment Service Mode. An H value will be displayed in the upper left hand corner of the display. Adjust the fan speed to obtain a nominal 80-100 fpm, using the up and down arrow buttons (#6 and #7 on Control Panel Diagram page 11). 4. Check the airflow using either a calibrated thermal anemometer. If the value attained in the step does not reflect the displayed fpm value, then a further adjustment of air speed value coefficient display will be required. Located to the far right of the UV time display is a number (MValue) with a range of 1 to 255. By using the airflow buttons this value can be lowered to drop F.P.M. display speed or increase number to raise the F.P.M. value. Typically, there is a fluctuation on average of 10 F.P.M. PLEASE NOTE THIS FEATURE IS FOR A GUIDE ONLY AND DOES NOT NEGATE THE NEED FOR YEARLY CERTIFICATIONS. 5. Press the Airflow button simultaneously and hold for 5 seconds to lock the speed. The unit will now run at the pre-set speed indicating the proper down flow. 6. Turn off the Main Power toggle switch to exit the Speed Adjustment Service Mode.

VCM LAMINAR FLOW HOOD VERTICAL Installation and Operations Manual Revision: 04-Oct-17 Page 11 of 22 8. TECHNICAL PARAMETERS Parameters MODEL VCM-400 MODEL VCM-600 External Size (W x D x H) 52 x 32 ⅛ x 82 ¼ 72 x 32 ⅛ x 82 ¼ Internal Size (W x D x H) 48 ¾ x 25 x 24 68 ½ x 25 x 24 Shipping Weight With Stand 550 lbs. (250 kg.) 724 lbs. (328 kg.) Shipping Weight - Console Only 443 lbs. (201 kg.) 568 lbs. (258 kg.) Power Supply AC 110V +/-10% 60Hz +/-1Hz Consumption 900 W 1100 W Airflow Velocity 81 99 FPM average UV Lamp 30 W 40 W HEPA Filter 99.999% 1190 x 570 x 117 mm 1690 x 570 x 117 mm Noise 65 db (A) Note: Consumption includes fan operation to run unit this basic operation consumption should not exceed 500W 9. REPLACEMENT PARTS Parts Replacement HEPA filter for VCM-400 Replacement HEPA filter for VCM-600 Replacement pre-filter UV light for VCM-400 UV light for VCM-600 UV light ballast for VCM-400 UV light ballast for VCM-600 Light ballast for VCM-400 Light ballast for VCM-600 115-volt motorized impeller Capacitor for motor 8mf Front window glass for VCM-400 Front window glass for VCM-600 Control panel LCD complete system Tubular motor - window Order Number 20PR0004 20PR0007 10PR0110 20PR0005 20PR0006 20PR0010 20PR0011 20PR0012 20PR0013 17MI0006 17MC0006 20PR0014 20PR0015 20PR0001 20PR0003 10. OPERATION OF THE HOOD Differential Pressure Alarm If the pressure falls outside of the required specifications, an alarm will sound to alert the user. It s possible that the fan speed can be increased to correct this, or it may be time to replace the HEPA Filter inside the unit. Please contact your service personnel to do this.

VCM LAMINAR FLOW HOOD VERTICAL Installation and Operations Manual Revision: 04-Oct-17 Page 12 of 22 Control Panel 1. Air volume control 2. Fluorescent light 6. Front window down (airflow control in set up mode) 7. Front window up (airflow control in set up mode) 3. UV lamp 8. Airflow set up increase 4. Power switch 9. Airflow set up decrease 5. Electrical outlet 10. Display * Please note that the buttons on this control panel only need to be pressed lightly to activate them.* Connect the power supply, turn on the main power toggle switch then lightly press the power button the control panel. The display will show: FAN, 0.00m/s, LIGHT, UV, UV TIME:0000HOURS. Then the system will go into Stand-By Mode. on FAN CONTROL - With the sash at working height, press the fan button one time. The buzzer will sound, the display will briefly show FAN and then the display will go blank, and the fan will start. If the window is completely closed, the fan will not come on. FLOURESCENT LIGHT CONTROL - Press the button one time, the buzzer will sound and the light will come on. The LCD display will read LIGHT.

VCM LAMINAR FLOW HOOD VERTICAL Installation and Operations Manual Revision: 04-Oct-17 Page 13 of 22 UV Lamp CONTROL - With the window fully closed, press the button one time. The buzzer will sound once, and the UV lamp will come on. While the UV is lit, the LCD display will read UV. The UV lamp will only come on if the sash is lowered completely. If it is not lowered all the way and the button is pressed, the buzzer will sound, but the light will not come on. ELECTRICAL OUTLET CONTROL - When this button is pressed, the buzzer will sound once, and the LCD display will read SOCKET and there will be power available to the electrical outlets located inside the work area. Pressing the button again will cut power to the outlets. SASH DOWN CONTROL - Press and hold this button to lower the sash, release the button when desired height has been reached. SASH UP CONTROL - Press and hold this button to raise the sash, and release the button when desired height has been reached. NOTE: WHEN THE SASH IS FULLY CLOSED, THE UV AND FLUORESCENT LAMPS WILL WORK, AND THE FAN WILL NOT. WHEN THE SASH IS IN AN OPEN POSITION, THE FLUORESCENT LIGHT AND FAN WILL WORK, BUT THE UV WILL NOT.

VCM LAMINAR FLOW HOOD VERTICAL Installation and Operations Manual Revision: 04-Oct-17 Page 14 of 22 11. AIR FLOW DIAGRAM 12. CLOCK ADJUSTMENT With the unit in standby mode, press the light button. The minutes on the clock will flash and can be adjusted using the arrow up/down keys. After adjusting the minutes, press the fan button to be able to adjust the hours by using the arrow keys. Once the correct time is set, press and hold the light button for approximately 5 seconds. Alarm will sound indicating that the time has been set and saved.

VCM LAMINAR FLOW HOOD VERTICAL Installation and Operations Manual Revision: 04-Oct-17 Page 15 of 22 13. MAINTENANCE A full maintenance cycle/certification should be performed once per year, or every 1,000 working hours. Please remove power to the unit before servicing. The frequency of working hours will affect the service frequency. A full certification should be performed, and a detailed report provided by your certifier once per year or more. Cleaning should be performed on a daily basis using the following methods: Non-working area should be cleaned with mild detergent and water (or stainless cleaner on the stainless steel parts) and then wiped dry with a soft clean towel. Working area should be cleaned using alcohol or other suitable disinfecting agent. Please ensure that the disinfecting cleaner is suitable for use on stainless steel to avoid damage.

VCM LAMINAR FLOW HOOD VERTICAL Installation and Operations Manual Revision: 04-Oct-17 Page 16 of 22 14. ELECTRICAL WIRING DIAGRAM

VCM LAMINAR FLOW HOOD VERTICAL Installation and Operations Manual Revision: 04-Oct-17 Page 17 of 22 15. TROUBLESHOOTING 1. NO POWER a. Confirm that the unit is plugged in correctly and that there is no damage to the power cord. A multimeter can test that there is sufficient power at the electrical outlet to run the unit. b. Ensure that the fuses are intact. Replace if necessary. i. To access the fuses, open the front cover of the unit and support the cover using the two support brackets at either side. The fuses can be found on the right hand side inside two small black inline housings. c. If fuses are ok, keep the cabinet open and use a multimeter to test the input voltage of the transformer (should be the same as the supply power) and test the output voltage (should be 12v). If the voltage is lower than 10 V, replace the transformer. d. If after checking all electrical is okay, and unit is still not working, the control board should be changed. 2. DISPLAY SCREEN IS BLANK a. Open the front control panel and secure with support arms. b. Confirm that the electrical connection to the board is good. c. If all is good but display is still blank, display requires replacement. 3. BUZZER WILL NOT SOUND a. Change out the control panel. 4. WINDOW WILL NOT GO UP OR DOWN a. Test the voltages between CN8 (up door/down door) and the power lock (black rocker switch). If there is no voltage showing at any of these points, the control panel needs to be replaced. b. If the voltage output is normal at the above locations, then confirm the connections to the window motor are good, and test the voltage output of the motor. If there are no voltage outputs, the motor needs to be replaced. 5. INTERIOR OUTLETS HAVE NO POWER a. First confirm that the power is on to the interior electrical outlets by pressing and trying the outlet again. b. Test the outlets with a multimeter to confirm whether there is power and inspect for damage. c. Check that the fuses are intact, and replace if necessary.

VCM LAMINAR FLOW HOOD VERTICAL Installation and Operations Manual Revision: 04-Oct-17 Page 18 of 22 d. If problem persists, open the front panel of the cabinet and check all voltages going to the electrical outlet and confirm all connections are secure. 6. FLOURESCENT LAMP DOES NOT WORK a. Confirm that the connections at each end of the bulb are secure. b. Remove the bulb and check to see if the ends are blackened. If they are, then replace the bulb. c. If the bulb is good, then check the voltage going to the light ballast, if there is no power and all connections are secure, replace the control panel. 7. UV LIGHT DOES NOT WORK a. Using a cloth, or gloved hands, check that the connections at each end of the bulb are secure. b. Look at the inside filament of the bulb if it is broken then replace the bulb. c. Lift the front panel and check that the connections to and from the control panel are secure. (UV ballast is located inside the front cover on the right hand side) d. Check the voltage between the UV ballast and the control panel if there is no power going to the UV ballast, replace the control board. If there is no power output at the ballast, replace the light ballast. 8. FAN WILL NOT TURN ON a. First ensure that the window is OPEN when trying to operate the fan. If the window is closed the fan will NOT come on. This is a factory setting and should not be tampered with. b. Open the front panel of the cabinet and check that there is no damage on the UV interlock switch or its connecting wire. If there is any damage, replace the overtravel limit switch or re-connect the wire. c. Check the connection between the fan and the circuit board to ensure that it is secure reconnect if necessary. d. If connections are good, but fan is still not running, connect the fan directly to the power if the fan will not run, it needs to be replaced.

VCM LAMINAR FLOW HOOD VERTICAL Installation and Operations Manual Revision: 04-Oct-17 Page 19 of 22 16. FAN AND HEPA FILTER REPLACEMENT 1. To replace the fan assembly: a. Ensure that window is fully lowered and ensure that unit is powered off and disconnected from power source. b. Loosen the screws on the sides of the lifting front panel. c. Lift the front panel and secure using the two support arms on either side. d. Undo the white window lift straps, noting position of strap ends. e. Unplug the power cord located inside the upper right hand side near the fan housing. f. Undo the bolts holding the pressure bars across the top of the fan housing and lift bars away. g. Lift off the fan housing and disconnect all electrical connections. h. Undo the 8 nuts (4 at the front and 4 at the back) that secure the fans within the housing cover. i. Replace the fan unit, reconnect and reassemble making sure that the pressure bars are secure. j. Make sure straps are level. 2. To replace the HEPA Filter: a. Follow steps (a) through (g) for fan replacement. b. HEPA Filter can only be removed once the fan housing has been lifted out. c. Gasket must be on BOTH sides of the filter frame to ensure a good seal. d. Installation: Reinstall in reverse order as above. PLEASE NOTE: HEPA Filters are fragile and must be handled with extreme care to avoid punctures or other damage which will have a direct impact on the effective operation of your equipment. Your hood should be fully certified by a qualified professional following a HEPA Filter replacement to be certain the airflows are correct and that there are no leaks in the filter.

VCM LAMINAR FLOW HOOD VERTICAL Installation and Operations Manual Revision: 04-Oct-17 Page 20 of 22 17. NOTES All repairs should be performed by qualified Certifiers only. If you do not have a certifier that you work with, please contact DFMZ and we can help you find a qualified certifier in your area. Please make sure that all electrical requirements are met before connecting and using this equipment. This equipment requires a three prong outlet. DO NOT remove the third prong in order to use an incompatible outlet. If necessary, contact a qualified electrician to install a properly grounded three prong outlet. Maximum weight of objects on the work surface should not exceed 23 kgs or 50 lbs. If possible, try to avoid the use of equipment that could shake or vibrate the hood (such as a centrifuge or spiral oscillator). The vibrations given off by this type of equipment can lead to shedding of particles from the HEPA filter, resulting in unclean work area or exposure to the operator. NEVER USE OPEN FLAME INSIDE CABINET open flames will disrupt the airflow and cause damage to the filter. If high temperature sterilization is required this should be done outside the cabinet. HEPA Filters have a limited service life. Debris accumulates on the face of the filter, leading to pressure drops. The alarm will indicate when the pressure has dropped beyond acceptable levels, at which time you should contact your certifier for service/hepa filter replacement. All sealed openings on the cabinet should not be tampered with. If a situation arises where access is required, please contact a qualified certifier or DFMZ for assistance. Storage period for this equipment is one year. Following any extended storage, the equipment should be carefully cleaned, inspected and fully certified before first use. DFMZ Group is not responsible for any damage or injury resulting from incorrect use of this equipment.

VCM LAMINAR FLOW HOOD VERTICAL Installation and Operations Manual Revision: 04-Oct-17 Page 21 of 22 18. SERVICE/MAINTENANCE NOTES

VCM LAMINAR FLOW HOOD VERTICAL Installation and Operations Manual Revision: 04-Oct-17 Page 22 of 22 19. WARRANTY Design Filtration Microzone warrants the equipment to be free of defects in materials and workmanship from the date of invoice. The VCM Laminar Flow Hood shall be warranted against defects for a period of five years. Any units or parts found to be defective during this period will be replaced or repaired at our discretion. The buyer agrees to assume all transportation charges prepaid for return of unit to factory for repair. Design Filtration Microzone will not accept charges for removal or re-installation. Design Filtration Microzone will not accept any returned items without prior written consent. Design Filtration Microzone is not responsible for repair or replacement by misuse or abuse by incorrect operating procedures of its equipment. Pre-filters and carbon filters carry no warranty against loading. Any modifications or changes made to equipment by customer without written consent of Design Filtration Microzone will void the warranty. Model number and serial number located on your VCM Laminar Flow Hood must be provided to verify invoice date. Failure to provide will void warranty. FOR FURTHER INFORMATION, PLEASE CONTACT US DIRECTLY. Design Filtration Microzone Inc., 86 Harry Douglas Drive, Ottawa, ON. K2S 2C7 T: 1-888-636-8609 (Canada & USA), T: 1-613-831-8318, F: 1-613-831-8321 info@dfmzgroup.com