Electro hydraulic actuating system is a complete modular unit with a wide range of actuator cylinders (type ASM) having a

Similar documents
Direct contact, metal-to-metal seating, make the gate valve ideal for most shutoff applications. Class 800 ANSI.

Direct contact, metal-to-metal seating, make the gate valve ideal for most shut-off applications. Class 800 ANSI.

SEMPELL TURBINE BYPASS VALVE MODEL 115 CHP

Control Valve From high-temperature/ high-pressure plant to process plant

DRAG VLN Turbine Bypass Valve for Hot Reheat Bypass Applications

Series Direct contact, metal-to-metal seating, make the globe valve ideal for most shut-off applications. Features

Series Direct contact and metal-to-metal seating makes the T-pattern globe stop valve ideal for most shut-off applications.

All From One Source Hydraulic Closed Loop Control Systems for Gas and Steam Turbines

YARWAY HANCOCK Y-PATTERN FORGED STEEL GLOBE STOP VALVES SERIES 4000

Please note this is a condensed catalog. For a complete version, contact Velan directly.

PRESSURE REDUCING AND DESUPERHEATING STATIONS SERIES

Designed to provide maximum service life with minimum maintenance.

Aeroflow SCV Steam Control Steam Conditioning Turbine Bypass Valve

STEAM TURBINE BY-PASS AND STEAM CONDITIONING VALVE

Sempell Dewrance Check valves Bled steam

High Pressure Turbine Bypass Valve HBSE

High Pressure Bypass System Type SOV acc. to TRD 421

Turbine Bypass. Systems

NARVIK-YARWAY. Heavy Duty A.T. - Temp Desuperheater Model: 18/54 and 28/64

Type K03. Gate Valve Butt-Welded, Flanged DN PN Data Sheet Edition: EN 9 / together we are strong

Document Code: 1 (8) Issuing date: Status:

VAD Variable Area Desuperheaters

Willem van der Westhuizen Pump Consultant Eskom Enterprises Engineering Johannesburg South-Africa. Master Degree in Mechanical Engineering

Table of Contents. Introduction. Description. Greater Total System Efficiency. Improved Design. Easy Installation and Maintenance

HIGH TEMPERATURE HIGH PRESSURE CONTROL VALVES SERIES

Note: The Gimpel EHTTV is not designed to replace the steam turbine governor.

DEWRANCE. Check Valve Bled Steam

Valves and Solutions for Power Plants. Engineering GREAT Solutions

DESUPERHEATER (SERIES 800)

Valve Portfolio. Slide 0

Startup and Operation of SEE-THRU Nuclear Power Plant for Student Performance MP-SEE-THRU-01 Rev. 018

FORGED HIGH PRESSURE BONNETLESS. ASME CLASSES: Sizes: 1 2 4" ( mm) U.S. Patent # Patented Easy Maintenance!

Yarway Narvik Desuperheater Model 18/54 and 28/64 Heavy Duty

VELAN COMPANY PROFILE

Check Valves High Pressure Steel

UREA AND AMMONIA PLANT COMPRESSORS NEW GENERATION PRACTICAL COMPREHENSIVE SOLUTIONS

Delayed Coking. Process Overview

13900 Series. Consolidated * Valves. Pilot-Operated Safety Relief Valve

Fisher 644 and 645 Differential Pressure Pump Governors

Your Partner for the Fossil-Fuel Fired Power Industry

Specially designed low-maintenance control valves for a wide range of applications in water circulation

H i g h P r e s s u r e V a l v e

GLOBE 3 WAY CONTROL VALVE SERIES INTRODUCTION

Pressure Relief Valves. 1541/1543 Series. Consolidated Safety Valve

FM SAMUANG TURBINE BYPASS SYSTEM

SECTION H4 BOILERMATE DEAERATORS

Fisher TBX Steam Conditioning Valve

Steam-Conditioning Valve

DESUPERHEATING CONTROL VALVE STRAIGHT-WAY SERIES

Gas Turbine Power Plant Mr.B.Ramesh, M.E.,(Ph.D)

Electrohydraulic Drive System EHC-A

Unit s 1 & New Berlin Road No.109 Jacksonville, Florida Global Power Generation Services, All Rights Reserved.

Fisher Sliding-Stem Valve Selection Guide

TempLowHT Steam Desuperheater Model: 59/69/79

Experiences with the improvement of minimum load in coal fired power stations. Manfred Schesack

Valve Portfolio by Function

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING

P. R2...P. Two. have. become. Range of Pressure-Independent Control Valves. one

Fisher DFA Variable Geometry Desuperheater

Control valves with pneumatic actuators up to 350 C PN

Coal Fired Boilers. Technologies for Improved Efficiency & Reduced Emissions. C.Jayadevan Bharat Heavy Electriclas Ltd. Tiruchirappalli, India

TURBINE SPRES (210MW-LMZ Units)

High performance safety valve for the protection of large boilers and superheaters, certified to ASME Section I.

CONTROL VALVES QUALITY, DEPENDABILITY, SERVICE. REPUTATION BUILT ON. Innovative Solutions

YARWAY NARVIK STANDARD DUTY A.T.-TEMP DESUPERHEATER MODEL 38/48

HANCOCK 600 GATE, GLOBE AND CHECK VALVES FORGED STEEL

FLOW TEK VALVES & CONTROL S INC

TBHP/TBLP/TBGT-Series. Turbine Bypass, Steam Conditioning Valve Fossil, HRSG, Bio-mass

CSP-gas hybrid plants: Cost effective and fully dispatchable integration of CSP into the electricity mix

PRESSURE EQUIPMENT EXEMPTION ORDER

Type 644 and 645 Differential Pressure Pump Governors

VLR. Engineering GREAT Solutions. Pressure Reducing Valve

Fasani Pressure Seal Cast Gate Valves - Style A Wedge Gate and Parallel Slide

National Research Council

Bolted Bonnet Valves. (BL Series) Cast Steel. Cast Steel Bolted Bonnet Valves - BL Series

Air Operated Valve Control Valve

78200/18200 Series LINCOLNLOG Valves Anti-cavitation High Pressure Control Valves

SERIES MULTIPLE NOZZLE DESUPERHEATERS

FRISCH ENGINEERED PRODUCTS INC.

ECOLINE GTC Type Series Booklet

DBO(Y)(S)-3 CONTROL VALVE SIZES 2" 8" ANSI CLASS 125/250, 150/300, 600

CONTENTS. Functioning of steam turbines and their constructional features. valve Gland sealing, control oil, seal oil, lubricating oil systems

SAMPLE SPECIFICATIONS

Honeywell EN REV. 2 09/2014 Page 1 of 10 Specification

Advanced gas turbine power cycles

MILITARY STANDARD SCHEDULE OF PIPING, VALVES, FITTINGS, AND ASSOCIATED PIPING COMPONENTS FOR NAVAL SURFACE SHIPS

Automatic Recirculation Valves One Step Centrifugal Pump Minimum Flow Protection

DBOY Series Pneumatic Control Valve

SECTION H3 TRAYMASTER SERIES DEAERATORS

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER E: THE REACTOR COOLANT SYSTEM AND RELATED SYSTEMS

STAAL 40 AKD/AKDS Type Series Booklet

LINE BFS INCORPORATION

Atwood & Morrill Co., Inc. Valve and Flow Control Equipment Specialists Since 1900

Isolation Valves. Live Loaded Metal Seats. Bi-Directional Flow Control. Double Block and Purge. In-Line Serviceable

PREHEATER BYPASS SYSTEMS

Thermodynamics II MIDTERM MECH 351/2 Fall 06 CONCORDIA UNIVERSITY FACULTY OF ENGINEERING AND COMPUTER SCIENCE DEPARTMENT OF MECHANICAL ENGINEERING

TURBINE BYPASS SYSTEMS

Fisher 585C Series Piston Actuators

SICCA SCC Type Series Booklet

DVG/AF Variable Geometry Desuperheater

Transcription:

Electro Hydraulic Actuating System 7 Electro hydraulic actuating system is a complete modular unit with a wide range of actuator cylinders (type ASM) having a force of about 100 tonnes and large stroke. 8 3 4 1 5 6 It consists of an Actuator cylinder (type ASM), Oil supply unit (type OV 32B), Servo valve (type ST), Blocking unit (type BL), Step control unit (type APL), Quick stroking device (type SSB). Each actuator is equipped either with one Servo valve and Blocking unit or a step control unit. Servo valve and blocking element control the open/close and stay-put function of the valves. 2 1. Actuator cylinder, type ASM 2. Oil supply unit, type OV 32B 3. Servo valve, type ST 4. Blocking unit, type BL 5. Step control unit, type APL 6. Connection plate 7. Additional accumulator 8. Quick stroking device, type SSB Hydraulic oil required under high pressure for the operation of the valves under high steam pressure is supplied by the Oil supply unit.

LP Bypass Spray Valve For spray water flow control to LP Bypass valve Valve body is made from forged Carbon steel A 105. Stem is made from High Chrome alloy steel 11Cr 1 Mo (X19CrMoVNbN111) Leak tight seat. Design Pressure : 50 kg/sq. cm Design Temperature : 300 C

LP Bypass Valve Model No : NR 64-500 EK Pressure reducing valve. Steam pressure reduction by throttling. Valve body is made from forged material of 2¼ Cr 1 Mo steel (A 182 F 22 Cl.3) Stem is made from High Chrome alloy steel 11Cr 1 Mo (X19CrMoVNbN111) To keep the stresses at optimum level, valve body is spherical in shape. Leak tight seat. Design Pressure : 64 kg/sq. cm Design Temperature : 540 C

HP Bypass Spray Valve Model No : E22S, E32S, E45S For spray water flow control to HP Bypass Valve. Pressure reduction & flow control achieved in three stages to avoid erosion due to high pressure drop. Valve body is of "Z" configuration made from forged carbon steel A 105. Stem is made from high chrome alloy steel 11Cr 1Mo (X19CrMoVNbN111) Leak Tight Stellite Seat. Design pressure : 350 kg/sq.cm Design temperature : 300 C

HP Bypass Valve Combined pressure reducing and de-superheating valve. Steam pressure reduction by throttling and temperature reduction by spray water injection To suit varying high pressure and temperature, the valve body is made from forged material of 2¼ Cr 1 Mo steel (A182 F22 Cl.3). To keep the stresses in optimum level, valve body is made of spherical shape. Leak tight seat. (HS 25) Stem is made from high chrome alloy steel 11 Cr 1 Mo (X19CrMoVNbN111). Design pressure : 200 kg/sq.cm Design temperature : 545 C Model Nos: ARS 45, ARS 50, ARS 63, ARS 72, ARS 80, ARS 90, ARS 100, ARS 112, ARS 140 & ARS 140A

HRH MSL BP BOILER HPT CRH CRHNRV LBP BPE BD BFP M P T LPT LPC CON LBPE LEGEND BP - HP BYPASS VALVE BD - SPRAY WATER ISOLATION VALVE BPE - SPRAY WATER FLOW CONTROL VALVE LBP - LP BYPASS VALVE LPC - LP COOLER LBPE - LP BYPASS SPRAY VALVE HPT - HIGH PRESSURE TURBINE MPT - MEDIUM PRESSURE TURBINE LPT - LOW PRESSURE TURBINE CRHNRV - CRH NON RETURN VALVE BFP - BOILER FEED PUMP CON - CONDENSER MSL - MAIN STEAM LINE HRH - HOT REHEAT LINE CRH - COLD REHEAT LINE

Sustained flow through the boiler heating surfaces is assured, ensuring Re-heater protection during start-up of units. If the grid cannot accept power, the unit can be kept running on house load. Almost all power plants are provided with HP-LP bypass systems for technical and economical reasons. The technology has been obtained from SULZER THERMTEC, Switzerland and we manufacture all the components in-house. BHEL has supplied bypass systems to over 150 power plants of 120/210/250/500 MW rating with a total installed capacity of over 32,000 MW.

High pressure (HP) and Low pressure (LP) bypass systems are used for quick start-up of the unit as well as during trip-out, where load rejection at the turbine does not automatically lead to a boiler trip. With a bypass system, start-up is quicker. The system diverts the steam generated by the boiler to the Re-heater/Condenser, at the same time reducing the pressure and temperature of steam, thus maintaining a minimum circulation of steam through the boiler. This enables running the boiler without the turbine in service, ensuring flow through re-heater coils. BHEL HP-LP bypass system has the following advantages : The prolonged venting of safety valves to atmosphere is avoided, thereby reducing DM water loss and cutting noise emission. Contd...

HP Bypass Valve HP Bypass Spray Valve LP Bypass Valve LP Bypass Spray Valve Electro Hydraulic Actuating System HP/LP Bypass System