FLEX CONNECTOR HEAT SHRINK SLEEVE INSTALLATION GUIDE

Similar documents
ANTI-SYPHON VALVE INSTALLATION GUIDE

PMA INTAKE FILTER SCREEN INSTALLATION GUIDE

FLEX-ING TM DISPENSER HOSES INSTALLATION GUIDE

ADJUSTABLE ROTARY SCRAPER TOOL SCR USER S GUIDE

RIGID ENTRY BOOT INSTALLATION GUIDE

EVO TM 200 AND EVO TM 400 LCD DISPLAY INSTALLATION GUIDE

COMPOSITE ACCESS COVER INSTALLATION GUIDE

SEALING DIP CAP INSTALLATION GUIDE

DIESEL EXHAUST FLUID PUMPING ACCESSORIES INSTALLATION GUIDE

DIESEL EXHAUST FLUID PUMP MOTOR ASSEMBLY REPLACEMENT GUIDE

FLEX PROBE INSTALLATION AND PROGRAMMING GUIDE

DEFENDER SERIES OVERFILL PREVENTION VALVE INSTALLATION GUIDE

DEFENDER SERIES BELOW GRADE DOUBLE WALL SPILL CONTAINER INSTALLATION GUIDE

SMART CONTROLLER I INSTALLATION GUIDE

Defender Series. Overfill Prevention Valve. Automatic Shutoff for USTs. Installation, Operation and Maintenance Series

Defender Series. Overfill Prevention Valve. Automatic Shutoff for USTs. Installation, Operation and Maintenance Series

3-PHASE SMART CONTROLLER STP-SCIIIC INSTALLATION GUIDE

DC400 Dispensing Cutoff System

High Capacity Submerged Turbine Pumps

STP-MLD Installation and Owner s Manual

STP-MLD+ Installation and Owner s Manual. Manual # Revision Date Changes from previous revision

Pro 30 Gas Caddy. Model FC-P30-UL Operator s Manual. JohnDow Industries, Inc. 151 Snyder Ave. Barberton, OH 44203

STP-DHI DISPENSER HOOK ISOLATION STP-DHI 120 Volt Hook STP-DHIB 240 Volt Hook

UNDERCARRIAGE KIT. Installation Instructions CAUTION. Read this document before installing the snowplow. CAUTION

RECEIVER MOUNT KIT LP-8 Tailgate Spreaders

IMPORTANT INFORMATION

Mount Kit. Chevy/GMC 1500HD/2500/3500 4X Chevy/GMC Suburban 2500 Yukon XL Installation Instructions CAUTION

GWI Rev. 1 October 2007 Supersedes Rev. 0 Dated February 2004

Blizzard, PO Box , Milwaukee, WI B31184 UNDERCARRIAGE KIT. Ford F

Blizzard, PO Box , Milwaukee, WI B32214 UNDERCARRIAGE KIT. Dodge Dakota Dodge Durango

Western Products, PO Box , Milwaukee, WI MOUNT KIT

IMPORTANT SAFETY NOTICE

Pro 30 Plus Gas Caddy

MOUNT KIT. Polaris Ranger Installation Instructions CAUTION. Read this document before installing the snowplow. CAUTION

MOUNT KIT. Kubota RTV 900, 1140 Kubota RTV X-Series. Installation Instructions CAUTION. Read this document before installing the snowplow.

B32207 UNDERCARRIAGE KIT. Parts List and Installation Instructions CAUTION. Read this document before installing the snowplow.

Installation. Introduction

DEFENDER SERIES. 5 Gallon, Single Walled, Field Replaceable Spill Container Fiberglass Model Series INSTALLATION, OPERATION, & MAINTENANCE

STP / IST Fixed & Variable Length

Galaxy VM. Battery Breaker Box Installation 09/

75918 Heavy Duty 3-Point Mount

Model 1000 Low Profile Tailgate Spreader Receiver Mount

Utility Mount. Tailgate Spreaders. Installation Instructions CAUTION. Read this document before installing or operating the spreader.

PRODIGY & PRO PLUS Skid Steer Snowplows

COOPER POWER SERIES. Current-Limiting Type NXC (C-Rated) Fuse Installation Instructions. Fusing Equipment MN132014EN

MOUNT KIT PERSONAL PLOW

MOUNT KIT. Installation Instructions CAUTION. Read this document before installing the snowplow. CAUTION

MOUNT KIT PERSONAL PLOW

MOUNT KIT. Installation Instructions CAUTION. Read this document before installing the snowplow. CAUTION

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

MOUNT KIT. Installation Instructions CAUTION. Read this document before installing the snowplow. CAUTION

STEP-BY-STEP INSTALLATION GUIDE

MOUNT KIT. Installation Instructions CAUTION. Read this document before installing the snowplow. CAUTION

Western Products, PO Box , Milwaukee, WI MOUNT KIT. Installation Instructions CAUTION

50 Gordon Drive, Rockland, Maine sherplows.com MOUNT KIT. Installation Instructions CAUTION

Blizzard, PO Box , Milwaukee, WI B35126 UNDERCARRIAGE KIT. John Deere Gator XUV/HPX. Installation Instructions

STP-MLD. Installation and Owner s Manual

MOUNT KIT. Dodge 4500/ Sterling Bullet 45/ Installation Instructions CAUTION

TOBi PI Wi-Z. Performance Indicator and Event Logger. Quick Installation Guide

User Guide IGD Series

MOUNT KIT. Polaris General 1000 Polaris RZR 900, Installation Instructions CAUTION. Read this document before installing the snowplow.

MOUNT KIT. John Deere HPX Installation Instructions CAUTION. Read this document before installing the snowplow. CAUTION

MOUNT KIT. Arctic Cat 700 HDX Exmark 500S, 700S Toro 500 EFI, 700 EFI Installation Instructions CAUTION

MOUNT KIT PERSONAL PLOW. Installation Instructions CAUTION. Read this document before installing the snowplow. CAUTION

Blizzard, PO Box , Milwaukee, WI B Undercarriage Kit. John Deere Gator XUV/HPX

33220 MOUNT KIT. Installation Instructions CAUTION. Read this document before installing the snowplow. CAUTION

BlinkerBeam Solar Controller

Intended Users This document is intended for Gasboy-certified Authorized Service Contractors (ASCs) and Customer Specified Contractors (CSCs).

MOUNT KIT GM K2500 w/8600 GVW GM K GM K2500 Suburban w/8600 GVW

50 Gordon Drive, Rockland, Maine MOUNT KIT

TBE-700. Operation, Safety and Maintenance Manual. Stainless Steel Weld Cleaning System. Ensitech Pty Ltd

Low Profile Tailgate Spreaders SWING AWAY Mount

DEFENDER SERIES. 5 Gallon, Double Walled, Field Replaceable Spill Container Model Series INSTALLATION, OPERATION, & MAINTENANCE

MOUNT KIT. Ford Bronco, F-150 4X Ford F-250/350/Super Duty Installation Instructions CAUTION

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

Intended Users This manual is meant for Gasboy Authorized Service Contractors (ASCs) who will install this kit on Atlas units.

Blizzard, PO Box , Milwaukee, WI UNDERCARRIAGE KIT. Ford Super Duty F-250/350/450/

Western Products, PO Box , Milwaukee, WI MOUNT KIT. Dodge 4500/ Sterling Bullet 45/

Propane torch. Model Assembly And Operation Instructions

IMPORTANT INFORMATION

MOUNT KIT PERSONAL PLOW

50 Gordon Drive, Rockland, Maine MOUNT KIT. Jeep Wrangler Installation Instructions

COOPER POWER SERIES. S.T.A.R. Hot line voltage indicator installation instructions. Fault Indicators MN320011EN. Indicator boot.

Cougar DC Truck Vibrators

MOUNT KIT. Dodge Ram 2500/ Installation Instructions CAUTION. Read this document before installing the snowplow.

WESTERN PRODUCTS, P.O. BOX , MILWAUKEE, WI MOUNT KIT. GM K1500 All New Silv/Sierra. Installation Instructions

TP300 INDUSTRIAL TRASH PUMP OPERATOR S MANUAL

Blizzard, PO Box , Milwaukee, WI UNDERCARRIAGE KIT. Dodge Ram 2500/3500. Installation Instructions CAUTION

MOUNT KIT. Kawasaki Mule Installation Instructions CAUTION. Read this document before installing the snowplow.

P.O. Box 529 Rockland, Maine MOUNT KIT. Installation Instructions

DIAGNOSTIC TOOL BATTERY

50 Gordon Drive, Rockland, Maine MOUNT KIT

TESTER ISOLATION MODULE LIGHT SYSTEM. Operating Instructions. CAUTION Read this document before testing any snowplows.

en Vibroplate VP 1550 (RAW) OPERATOR S MANUAL

OMEGA CORDLESS SERIES VACUUM INSTRUCTION MANUAL

Series K Pneumatic Switch Mechanism

The information in this instruction manual is subject to modifications without prior notice and is the exclusive property of Zorzini.

MOUNT KIT PERSONAL PLOW. Installation Instructions CAUTION. Read this document before installing the snowplow. CAUTION

Battery Back-up BBM Owner's Manual. Please read this manual BEFORE installing your inverter

Effective November 2016 Supersedes September 1998 (S )

Transcription:

FLEX CONNECTOR HEAT SHRINK SLEEVE INSTALLATION GUIDE

The information in this publication is provided for reference only. While every effort has been made to ensure the reliability and accuracy of the information contained in this manual at the time of printing, we recommend that you refer to franklinfueling.com for the most current version of this manual. All product specifications, as well as the information contained in this publication, are subject to change without notice. Franklin Fueling Systems does not assume responsibility and expressly disclaims liability for loss, damage, or expense arising out of, or in any way connected with, installation, operation, use, or maintenance by using this manual. Franklin Fueling Systems assumes no responsibility for any infringement of patents or other rights of third parties that may result from use of this manual or the products. We make no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Copyright 2017 Franklin Fueling Systems, Madison, WI 53718. All world rights reserved. No part of this publication may be stored in a retrieval system, transmitted, or reproduced in any way, including, but not limited to, photocopy, photograph, magnetic, or other record, without the prior written permission of Franklin Fueling Systems. For technical assistance, please contact: Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Web: franklinfueling.com Telephone: USA and Canada: +1.608.838.8786, +1.800.225.9787 USA and Canada Technical Support: +1.800.984.6266 UK: +44 (0) 1473.243300 Mexico: 001.800.738.7610 China: +86.10.8565.4566 407926001 r1

Contents Introduction...1 Conventions used in this manual...1 Questions and concerns...1 Operating precautions...2 Installation...3 Equipment required...3 Installing the heat shrink sleeve...3

Intentionally Blank

Introduction The Flex Connector Heat Shrink Sleeve is designed to protect flexible connectors from dirt and other contaminants. Conventions used in this manual This manual includes safety precautions and other important information presented in the following format: NOTE: This provides helpful supplementary information. IMPORTANT: This provides instructions to avoid damaging hardware or a potential hazard to the environment, for example: fuel leakage from equipment that could harm the environment. CAUTION: This indicates a potentially hazardous situation that could result in minor or moderate injury if not avoided. This may also be used to alert against unsafe practices. WARNING: This indicates a potentially hazardous situation that could result in severe injury or death if not avoided. DANGER: This indicates an imminently hazardous situation that will result in death if not avoided. Questions and concerns In case of emergency, follow the procedures established by your facility. If you have questions or concerns about safety or need assistance, use the information below to contact Franklin Fueling Systems: Web: franklinfueling.com Telephone: USA and Canada: +1.608.838.8786, +1.800.225.9787 USA Technical Support: 1.800.984.6266 UK: +44 (0) 1473.243300 Mexico: 001.800.738.7610 China: +86.10.8565.4566 1

Operating precautions Franklin Fueling Systems (FFS) equipment is designed to be installed in areas where volatile liquids such as gasoline and diesel fuel are present. Working in such a hazardous environment presents a risk of severe injury or death if you do not follow standard industry practices and the instructions in this manual. Before you work with or install the equipment covered in this manual, or any related equipment, read this entire manual, particularly the following precautions: IMPORTANT: To help prevent spillage from an underground storage tank, make sure the delivery equipment is well-maintained, that there is a proper connection, and that the fill adaptor is tight. Delivery personnel should inspect delivery elbows and hoses for damage and missing parts. CAUTION: Use only original FFS parts. Substituting non-ffs parts could cause the device to fail, which could create a hazardous condition and/or harm the environment. CAUTION: To help avoid a burn hazard, be careful when you use a heat gun. Follow all applicable regulations, wear appropriate PPE, and always wait at least ten minutes after installing the heat shrink sleeve before you handle it. WARNING: Follow all codes that govern how you install and service this product and the entire system. Always lock out and tag electrical circuit breakers while installing or servicing this equipment and related equipment. A potentially lethal electrical shock hazard and the possibility of an explosion or fire from a spark can result if the electrical circuit breakers are accidentally turned on while you are installing or servicing this product. Refer to this manual (and documentation for related equipment) for complete installation and safety information. WARNING: Before you enter a containment sump, check for the presence of hydrocarbon vapors. Inhaling these vapors can make you dizzy or unconscious, and if ignited, they can explode and cause serious injury or death. Containment sumps are designed to trap hazardous liquid spills and prevent environmental contamination, so they can accumulate dangerous amounts of hydrocarbon vapors. Check the atmosphere in the sump regularly while you are working in it. If vapors reach unsafe levels, exit the sump and ventilate it with fresh air before you resume working. Always have another person standing by for assistance. WARNING: Follow all federal, state, and local laws governing the installation of this product and its associated systems. When no other regulations apply, follow NFPA codes 30, 30A, and 70 from the National Fire Protection Association. Failure to follow these codes could result in severe injury, death, serious property damage, and/or environmental contamination. WARNING: Always secure the work area from moving vehicles. The equipment in this manual is usually mounted underground, so reduced visibility puts service personnel working on it in danger from moving vehicles that enter the work area. To help prevent this safety hazard, secure the area by using a service truck (or some other vehicle) to block access to the work area. WARNING: Discharge static electricity from the product to ground before you install it, and make sure it is properly grounded while in service. WARNING: Make sure you check the installation location for potential ignition sources such as radio waves, ionizing radiation, and ultrasound sonic waves. If you identify any potential ignition sources, you must make sure safety measure are implemented. 2

Installation IMPORTANT: The Flex Connector Heat Shrink Sleeve may not be allowed at your location. Before installing this sleeve, check and carefully follow the applicable national, state, and local codes and laws. IMPORTANT: You should have your connector inspected before you install the heat shrink sleeve. If you do not, you will have to remove the sleeve in order to have the connector inspected. CAUTION: The Flex Connector Heat Shrink Sleeve is not vapor-tight and is not designed to be a containment device. Do not use it in a direct-bury situation or to provide containment. Equipment required Heat gun Wire cutters Blade Tape measure PPE (gloves, eye protection) Acetone Synthetic brush Installing the heat shrink sleeve WARNING: If your connector is in a new installation where no volatile hydrocarbons (such as gasoline, gas vapor, or diesel fuel) are present, you may install the heat shrink sleeve in the containment area. If your connector is in an active site where volatile hydrocarbons are present, you must remove the connector, take it to a well-ventilated area where there is no spark hazard, and allow it to ventilate for 1 hour. 1. Remove the connector from containment. 2. If the connector is in an active site, use a synthetic brush and acetone to remove any corrosion on the connector. 3. If your connector has clamps on the ends, remove the clamp from one end of the connector. 3

4. Measure the distance between the welds on either end of the connector. Add 1 inch to the measured distance. This is the length your heat shrink sleeve should be. Weld Weld 5. Place the sleeve over the connector. It should be a maximum of ¼ inch (6.4 mm) beyond the weld at the starting end of the connector. (Choose either end of the connector to be the starting end.) At the opposite end of the connector, the sleeve should extend a minimum of ¾ inch (19 mm) beyond the weld. CAUTION: To help avoid a burn hazard, be careful when you use a heat gun. Follow all applicable regulations, wear appropriate PPE, and always wait at least ten minutes after installing the heat shrink sleeve before you handle it. 6. Hold the gun approximately 3 inches (76 mm) from the sleeve at the end of the connector where the sleeve is ¼ inch (6.4 mm) beyond the weld. 7. Apply heat evenly until the heat shrink sleeve is shrunk around the end of the connector. 8. Place a tie (included with the sleeve) on the solid collar below the weld, and tighten it. 9. Continue using the heat gun to shrink the sleeve onto the connector. Rotate the connector as you move toward the end without a tie. 4

10. When you reach the end, and the sleeve is completely shrunk onto the connector, place a tie on the solid collar below the weld, and tighten it. 11. Use wire cutters to cut off the loose ends of the ties. IMPORTANT: Make sure the heat shrink sleeve does not interfere with the movement at the ends of the connector. CAUTION: To help avoid a cut hazard, use caution when using a blade of any kind. Follow all applicable regulations and wear appropriate PPE. 12. Use a blade to remove any excess heat shrink sleeve at the ends of the connector. 5

Intentionally Blank

Intentionally Blank

A Franklin Fueling Systems Brand 407926001 r1