DCT 5 Industrial Pressure Transmitter with IO-Link Interface Stainless Steel Sensor accuracy according to IEC 60770: standart: ± 0.5 % FSO sption: ± 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar Digital output signals - IO-Link according to specification V. - Data transfer 8. kbaud - Smart sensor profile Special characteristic perfect thermal behaviour excellent long term stability Optional versions pressure port G /" flush up to 0 bar welded sensor specific versions IO-Link is a digital interface for sensors and actuators, which is worldwide ized by IEC 6-9. IO-Link does not have a bus topology, but it is a powerful point-to-point communication, where the device can be parametrized and the measured values transferred. The integration to the master is easy by using the IODD-file. The sensor technology of the DCT 5 is the same as those of the proven pressure transmitter DMP / DMP, whereby the DCT 5 is suitable for almost every industrial application, if medium is compatible with stainless steel 6L. The modular concept of the pressure transmitter allows customized electrical or mechanical connections, so it is easy to adapt the DCT 5 to different conditions on-site. Preferred areas of use are Plant and Machine Engineering Energy Industry BD SENSORS GmbH BD-Sensors-Straße Tel: +9 (0) 9 5 / 98-0 www.bdsensors.com D - 9599 Thierstein Fax: +9 (0) 9 5 / 98 - info@bdsensors.de
DCT 5 Input pressure range Nominal pressure gauge [bar] - 0 0,0 0,6 0,5 0,0 0,60,6,5 6 Nominal pressure abs. [bar] - - - - 0,0 0,60,6,5 6 Overpressure [bar] 5 0,5 5 5 0 0 0 0 Burst pressure [bar] 7,5,5,5,5 7,5 7,5 5 5 5 50 Nominal pressure gauge / abs. [bar] 0 6 5 0 60 00 60 50 00 Overpressure [bar] 0 80 80 05 0 600 600 000 000 Burst pressure [bar] 50 0 0 0 0 000 000 50 50 Vacuum resistance P N bar: unlimited vacuum resistance P N < bar: on request Output signal / Supply Standard IO-Link (measured value transmission) V S = 8... 0 V DC SIO (switching output) IO-Link V. / Slave / Smart Sensor Profile Data transfer COM 8, kbaud Mode SIO / IO-Link Standard IEC 6-9 Performance Accuracy for P N 0. bar: ± 0.5 % FSO for P N < 0. bar: ± 0.5 % FSO option for P N 0. bar: ± 0.5 % FSO Switching current (SIO-Mode) max. 00 ma switchingfrequency max. 00 Hz Switching cycles > 00 x 0 6 Long term stability ± 0. % FSO / year at reference conditions Switch-on time SIO-Modus: ca. 0 ms Response time SIO-Modus: < ms Measuring rate 00 Hz accuracy according to IEC 60770 limit point adjustment (non-linearity, hysteresis, repeatability) Thermal effects (Offset and Span) Nominal pressure P N [bar] - 0 < 0.0 0.0 Tolerance band [% FSO] ± 0.75 ± ± 0.75 in compensated range [ C] -0... 85 0... 70-0 85 Permissible temperatures Permissible temperatures medium: -5... 5 C electronics / environment: -5... 85 C storage: -0... 85 C Electrical protection Short-circuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 Mechanical stability Vibration 0 g RMS (5... 000 Hz) according to DIN EN 60068--6 Shock 500 g / msec according to DIN EN 60068--7 Materials Pressure port / housing stainless steel.0 (6 L) Seals (media wetted) : FKM options: EPDM welded version Diaphragm stainless steel.5 (6 L) Media wetted parts pressure port, seal, diaphragm welded version only with pressure ports according to EN 87 others on request Miscellaneous Current consumption < 0 ma Weight approx. 0 g Installation position any Protection class IP 67 Operational life > 00 x 0 6 pressure cycles CE-conformity EMC Directive: 00/08/EC Pressure transmitters are calibrated in a vertical position with the pressure connection down. If this position is changed on installation there can be slight deviations in the zero point for pressure ranges P N bar. pressure and level
DCT 5 Wiring diagrams Pin configuration Electrical connection Supply + Supply SIO / IO Link Mx / metal (-pin) Binder 7 (5-pin) Shield housing housing cable colours (DIN 700) wh (white) bn (brown) gn (green) ye/gn (yellow / green) Electrical connections (dimensions in mm) option Mx -pin Binder Series 7 5-pin cable outlet with PVC cable cable outlet, cable with ventilation tube (IP 67) (IP 67) (IP 67) 5 (IP 68) 6 5 : m PVC cable without ventilation tube (permissible temperature: -5... 70 C) 6 different cable types and lengths available, permissible temperature depends on kind of cable Mechanische Anschlüsse (Maße in mm) G/" DIN 85 with Mx www.bdsensors.com
DCT 5 Mechanical connections (dimensions in mm) option G/" DIN 85 G/" open port G/" DIN 85 with flush sensor G/" EN 87 G/" EN 87 /" NPT /" NPT metric threads and other versions on request 05 BD SENSORS GmbH The specifications given in this document represent the state of engineeringat the time of publishing. We reserve the right to make modifications to the specifications and materials. DCT5_E_05 Tel +9 (0) 9 5 / 98-0 www.bdsensors.com pressure and level Fax +9 (0) 9 5 / 98 - info@bdsensors.de
Ordering code DCT 5 DCT 5 - - - - - - - Pressure Input Output Accuracy for P N 0. bar for P N < 0. bar option for P N 0. bar Electrical connection Male plug Mx (-pin) / metal Male plug Binder series 7 (5-pin) Cable outlet with PVC cable Cable outlet (IP68) Mechanical connection G/" DIN 85 G/" EN 87 G/" DIN 85 G/" EN 87 G/" DIN 85 with flush sensor G/" DIN 85 open pressure port /" NPT /" NPT Seals FKM EPDM without (welded version) Special version absolute pressure possible from 0. bar gauge absolute D C D C [bar] 0. 0 0 0 0.6 6 0 0 0.5 5 0 0 0. 0 0 0 0.6 6 0 0 0 0 0.6 6 0.5 5 0 0 0 6 6 0 0 0 0 0 6 6 0 5 5 0 0 0 0 60 6 0 0 00 0 0 60 6 0 50 5 0 00 0 0-0 X 0 9 IO-Link / SIO IO 0.5 % 0.5 % 5 0.5 % 0. % consult 9 consult : m PVC cable without ventilation tube (permissible temperature: -5 70 C), others on request cable with ventilation tube (code TR0 = PVC cable), different cable types and lengths available, price without cable welded version only with pressure ports according to EN 87 M 7 0 7 T A 0 T R 0 0 0 0 0 0 0 0 0 F 0 0 H 0 0 N 0 0 N 0 9 consult 0 0 0 5.0.05 05 BD SENSORS GmbH - The specifications given in this document represent the state of engineeringat the time of publishing. We reserve the right to make modifications to the specifications and materials.