Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

Similar documents
Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety

ATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22

Lighting: Fluorescent Lighting FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Zone 2 & 22

ATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

Lighting: Incandescent & HID Lighting PB, PC & PL Series: Floodlights Flameproof

FL Series Light Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2 and 22

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

Easy and safe installation

ATX PC Series Floodlights Flameproof. Metal Halide, High Pressure Sodium, Mercury Vapor, Halogen

110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations

Junction Boxes & Enclosures JBES and ECES Series: 316L Stainless Steel Enclosures Increased Safety

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22

Linear fittings EVNL LED fitting - zones 2, & 22

Linear fittings EVDL LED fitting - zones 21, & 22

Plugs & Sockets PRE Series: 16 A Plugs and Sockets Increased Safety

Compact Sheet-Steel Light Fittings Series 6114/1

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

Unicode 2 Series Pre-Drilled Control Stations Increased Safety Polyamide, Fiberglass Reinforced Polyester, 316L Stainless Steel, Aluminum

Linear fittings EVN Fluorescent fitting - zones 2 & 22

Panelboards & Motor Starters

ATX PRE Series 125 Amp Plugs and Sockets Increased Safety

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22

Linear fittings EVTL Weatherproof LED fitting - Industrial applications

IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

PROTECTA III. Construction Tough glass reinforced polyester body

EX-RECESSED CEILING LIGHT FITTINGS

ATX PRE Series 63 Amp Plugs and Sockets Increased Safety

Linear fittings EVTL Weatherproof LED fitting - Industrial applications

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)

ATX DPD Series Distribution Panelboards Flameproof

7 Lighting Technology

Linear fittings EVT Weatherproof fluorescent fitting - Industrial applications

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

PRE Series 125 Amp Plugs and Sockets Increased Safety

L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L

Floodlight LED Series 6525

Floodlight LED Series 6525

7 Lighting Technology

Linear fittings Fluorescent fitting EVN - Zones 2 & 22

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108

Sheet-Steel Light Fittings Series 6014 / 6414

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Sheet Steel Emergency Light Fitting Series 6018

Floodlight LED Series 6125

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Linear Luminaire with LED Series EXLUX 6402/2

EXEL-L. Detail of the internal side. Transparent polycarbonate

7 Lighting Technology

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W, 1000 W HID Light Level Equivalent

Compact Sheet-Steel Light Fittings Series 6114

PRE Series 63 Amp Plugs and Sockets Increased Safety

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

Emergency Light Fitting for Fluorescent Lamps Series 6009

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Applications. Illustrated Features

Mechanical features. Spring-loaded elastic terminals: resist vibrations

7 Lighting Technology

LED Linear Luminaire Series EXLUX 6402

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

AVN. - Zone 2, 21, 22 - Lower maintenance costs - Easy to install - Suited to ambient temperatures of up to +55 C. Ex n. Stainless steel clips

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Linear luminaire with LED Series EXLUX 6002

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

RSS SERIES R S S. Fluorescent Lighting for Hazardous Locations

Linear fittings EVD Fluorescent fitting - zones 21 & 22

Linear Luminaire with LED Series EXLUX 6002

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

FV Series Nonmetallic Fluorescent Luminaires For Hazardous and Adverse Locations

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Emergency Luminaire with LED Series EXLUX 6409/1

EWE. Ex de. Cooling fins

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

MAR SERIES Fluorescent Lighting for Hazardous Locations

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

MHDS SERIES M H D S. Stainless Steel Marine Heavy Duty Luminaire for Hazardous Locations

20 A / 32 A / 63 A DECONTACTOR MOUNTING: SWITCH SHOULD BE ON THE UPPER SIDE!

OSRAM DEDRA plus T8 DPTB / VATS / VABS / VB

I-BRICK. High quality LED from Samsung. Curve shaped design. Vandal proof protective cover. Visual comfort. Available in 2 sizes.

TUNNEL54. Safety and fire resistance VENTILATION LIGHTING

APPLICATIONS APPROVALS. GASKET One piece neoprene. LATCHES Plated steel twist draw. ENTRIES 1 2 NPT feed-through outlets, 3 4 NPT outlets optional.

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

Terminal Boxes in Stainless Steel SLS**.T

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

BRUDA. Removable control gear plate. Computer aided design reflector. Single piece high-pressure diecast aluminium housing.

Linear fittings EVT Weatherproof fluorescent fitting - Industrial applications

Transcription:

4 x 18 W Surface Mounting 2 x 36 W Recessed Compliance Data: ATEX IECEx: ATEX IECEx CE Ex de IIC or Ex demb IIC (emergency version) T6 to T4 Ex td A21 T 75 C Technical Data: 18 W 36 W 58 W 1, 2, 3 & 4 Lamp Versions Fluorescent T8 (Bi-pin G13) 110 to 254 Vac/Vdc +/- 10% 50/60 Hz Recessed or Surface Mounting Painted or Stainless Steel Front Access Operating Temperatures: -20 C to +55 C 25 ATX Product Catalog

Applications: Designed for flush or surface mounting; most specifically clean room environments where a seamless smooth ceiling is mandatory. Typical applications include: the food industry, chemical plants, pharmaceuticals and delicate electronic manufacturing such as the aerospace industry. Ideal for rigorous corrosive environments, involving water, dust and extreme temperature variations. Can be installed in hazardous areas designated as Zone 1, 2, 21 and 22. Features: One-piece welded steel housing with integral frame to seal out contaminants. Allows recessed mounting in permanent ceilings from 55 mm to 130 mm (2" to 5" approximately). Frameless tempered (safety) 5 mm (1/4") thick lens. Lens secured to housing by internal metallic hinges and secured with captive 316L stainless steel screws, allowing for easy lamp replacement and fixture maintenance. Positive safety switch and new Ex e battery with plug-in connector for safety and easy maintenance in hazardous locations. Designed for ease of installation and maintenance. Bi-pin G13 lampholder. Also available as surface mounting version. New ballast: EOL (End Of Life) protection in accordance to the latest EN 60079-7 standard Multi-tap 110 to 254 Vac/Vdc +/-10% 50/60 Hz Two channel standard ballast (if one lamp fails the second lamp remains in operation) Ex e plug-in connector for rapid and error free maintenance Self test on 3 hours duration emergency version High power factor electronic ballast (>0.95) Termination/Wiring: Terminal capacity: 4 mm 2 (flexible) or 6 mm 2 (solid). Loop in/loop out: One terminal block Standard version: 2 (L) + 2 (N) + 2 (PE) Emergency version: 2 (LP) + 2 (L) + 2 (N) + 2 (PE) Through wired: Two terminal blocks (one at each end) Standard version: 2 (L) + 2 (N) + 2 (PE) 1 (L) + 1 (N) + 1 (PE) Emergency version: 2 (LP) + 2 (L) + 2 (N) + 2 (PE) 1 (LP) + 1 (L) + 1 (N) + 1 (PE) PE: Earth N: Neutral L: Live LP: Permanent Live for emergency version Cable Entries: Three clearance holes for M20 cable gland supplied with M20 polyamide cable gland (cable dia. 6.5 to 14.5 mm) and M20 polyamide blanking plug as below quantity: Cable Blanking Nickel Plated Version Gland Plug Brass Locknut Loop 1 2 3 Through 2 1 3 One M6 earth stud. Standard Materials: One-piece white powder epoxy painted welded steel housing and integral frame. 5 mm thick tempered safety lens. Silicone 4 lips gasket completely sealed and contained in the fixture. White polycarbonate multi-parabolic internal reflector. Polyamide cable gland and blanking plug. Standard Finishes: White powder epoxy paint Options: 316L stainless steel housing and integral frame, natural finish. Through wiring. White powder epoxy painted steel reflector. Catalog Number Logic: RE B X XX XX X X X Series: Number of Lamps: 1 = 1 Lamp 2 = 2 Lamps 3 = 3 Lamps 4 = 4 Lamps Lamp Type: B = Bi-pin (G13) Wattage: 18 = 18 Watt 36 = 36 Watt 58 = 58 Watt (1) = As standard for 18 W emergency version and 4 lamp version (2) = T/W and Loop in/loop out - 3 cores (single phase) (3) = Only for standard versions Voltage: BU = 110 to 254 Vac/Vdc 50/60 Hz B3 = 100 to 130 Vac/Vdc 50/60 Hz BK = 220 to 254 Vac/Vdc 50/60 Hz Mounting/Access: F = Recessed Lighting/Front Access (U Shape) M = Surface mounting Lighting Termination/Wiring: L = Loop In/Loop Out T = Through wired (2) Options: E = 3 H Emergency (combined) - Battery 6 V - 4 Ah E1 = 1 H 30 Emergency (combined) - Battery 6 V - 7 Ah E7 = 3H Emergency (combined) - Battery 6 V - 7 Ah N = No switch (3) P = White painted steel internal reflector (1) S = 316L Stainless steel housing ATX Product Catalog 26

Ordering Information: Recessed 110/254 Vac/Vdc 50/60 Hz Front access White Painted Steel Housing Weight Volume Catalog Version Wiring Reflector (Kg) (dm 3 ) Number Standard Version Bi-pin Lamps (G13) 2 x 18 W Loop Polycarbonate 14 64 REB218BUFL 2 x 18 W Through Polycarbonate 14 64 REB218BUFT 4 x 18 W Loop White Painted Steel 21 93 REB418BUFLP 4 x 18 W Through White Painted Steel 21 93 REB418BUFTP 2 x 36 W Loop Polycarbonate 19 108 REB236BUFL 2 x 36 W Through Polycarbonate 19 108 REB236BUFT 4 x 36 W Loop White Painted Steel 29 158 REB436BUFLP 4 x 36 W Through White Painted Steel 29 158 REB436BUFTP 2 x 58 W Loop Polycarbonate 22 130 REB258BUFL 2 x 58 W Through Polycarbonate 22 130 REB258BUFT 4 x 58 W Loop White Painted Steel 32 190 REB458BUFLP 4 x 58 W Through White Painted Steel 32 190 REB458BUFTP 3 Hours Emergency Version Bi-pin Lamps (G13) 2 x 18 W Loop Polycarbonate 14 64 REB218BUFLEP 2 x 18 W Through Polycarbonate 14 64 REB218BUFTEP 4 x 18 W Loop White Painted Steel 21 93 REB418BUFLEP 4 x 18 W Through White Painted Steel 21 93 REB418BUFTEP 2 x 36 W Loop Polycarbonate 19 108 REB236BUFLE 2 x 36 W Through Polycarbonate 19 108 REB236BUFTE 4 x 36 W Loop White Painted Steel 29 158 REB436BUFLEP 4 x 36 W Through White Painted Steel 29 158 REB436BUFTEP 2 x 58 W Loop Polycarbonate 22 130 REB258BUFLE 2 x 58 W Through Polycarbonate 22 130 REB258BUFTE 4 x 58 W Loop White Painted Steel 32 190 REB458BUFLEP 4 x 58 W Through White Painted Steel 32 190 REB458BUFTEP For non-recessed lighting, please replace letter F with letter M as per Catalog number logic. Example: REB218BUFL becomes REB218BUML. Accessories: Weight Volume Catalog Description (Kg) (dm 3 ) Number Ceiling Mounting Brackets - Set of Two Zinc plated steel 2.00 RECMST 316 stainless steel 2.00 RECMSS M8 Eye Bolts - Set of Four Zinc plated steel 0.25 REEBST 316 stainless steel 0.25 REEBSS Fixing Brackets - Set of Four Zinc plated steel 0.60 REFBST 316 stainless steel 0.60 REFBSS 27 ATX Product Catalog

Wiring Diagram: Mains PE N L Emergency Function Diagram: Two Lamp Version Mains Lighting Switch ON Lighting Switch OFF Lighting Switch L ON U N PE Standard Fluorescent Lighting Fixture OFF Three Lamp Version Mains Lighting Switch ON Lighting Switch OFF U U N PE Emergency Fluorescent Lighting Fixture ON OFF LED status: Color Indication Function Green LED glows Batteries are connected LED blinks Batteries are charged Red LED blinks Batteries are not connected or defect Yellow LED blinks Batteries are charging and discharging during automatic cycle Emergency Light Duration: Emergency Version Battery Capacity Duration Light Output 2 x 18 W 4 Ah 6 V 3 hours 45% 2 x 36 W 4 Ah 6 V 3 hours 15% 7 Ah 6 V 3 hours 25% 2 x 58 W 4 Ah 6 V 3 hours 9% 7 Ah 6 V 3 hours 15% ATX Product Catalog 28

Compliances: Hazardous Area Gas Dust Certified Type Zones 1 2 21 22 Conforming to ATEX 94/9/CE CE 0081 II 2 G CE 0081 II2 D Symbol of Protection ATEX Ex de IIC / Symbol of Protection IEC Ex demb IIC (emergency version) RE Ex td A21 T Rating T6 to T4 (see table) N.A. Surface Temperature N.A. T75 C Ambient Temperature -20 C Ta +55 C CE Declaration of Conformity 50276 ATEX Certificate LCIE 07 ATEX 6104 IECEx Certificate IECEx LCI 07.0019 Other Certifications Index of Protection Impact Resistance (shock) IP66 IK09 or IK10 depending on version T Ratings: Ceiling Position Ambient Temperature Wall Position Ambient Temperature Version +40 C +50 C +55 C +40 C +50 C +55 C 2 x 18 W (1) T6 T5 T5 T5 T5 T4 2 x 18 W Emergency (1) T5 T4 T4 T5 T5 T4 3 x 18 W T5 T4 T4 T4 T4 T4 4 x 18 W T5 T4 T4 T5 T4 T4 2 x 36 W (1) T5 T4 T4 T5 T4 T4 2 x 36 W Emergency (1) T5 T4 T4 T5 T4 T4 3 x 36 W T4 T4 T4 T4 T4 T4 4 x 36 W T5 T4 T4 T5 T4 T4 2 x 58 W (1) T4 T4 T4 T4 T4 T4 2 x 58 W Emergency (1) T4 T4 T4 T4 T4 T4 3 x 58 W T4 T4 T4 T4 T4 T4 4 x 58 W T4 T4 T4 T4 T4 T4 (1) T rating for single lamp version is the same as twin lamp version. Standards: Ex Standards EN / IEC 60079-0; 60079-1; 60079-7; 60079-18; 61241-0; 61241-1 Product Standards EN / IEC 60598-1; 60598-2-22 EMC Standards EN / IEC 55015; 61547 Other Standards EN / IEC 60529 (IP); 62262 (IK) 29 ATX Product Catalog

Dimensions (mm): Dimensions (mm) Versions A B C D E F G H 18 W (1, 2, 3 lamps) 826 320 270 776 390 184 786 280 18 W (4 lamps) 826 490 440 776 390 354 786 450 36 W (1, 2, 3 lamps) 1436 320 270 1386 1000 184 1396 280 36 W (4 lamps) 1436 490 440 1386 1000 354 1396 450 58 W (1, 2, 3 lamps) 1736 320 270 1686 1300 184 1696 280 58 W (4 lamps) 1736 490 440 1686 1300 354 1696 450 Recessed Luminaire Surface Mounting Luminaire Ceiling Cut-out ATX Product Catalog 30

Photometric Data: Polar curves for a 1000 lm flux, according to NF C 71-120 Luminaire symbol according to NF C 71-121 Longitudinal Transverse 18 W Versions with Polycarbonate Reflector: 1 x 18 W Efficiency 67.1% NF C 71-121: 0.67 E 2 x 18 W Efficiency 62% NF C 71-121: 0.62 E 3 x 18 W Efficiency 61.2% NF C 71-121: 0.61 E 18 W Versions with Painted Steel Reflector: 2 x 18 W Efficiency 60.5% NF C 71-121: 0.60 F 4 x 18 W Efficiency 63.7% NF C 71-121: 0.63 E 36 W Versions with Painted Steel Reflector: 4 x 36 W Efficiency 61.5% NF C 71-121: 0.61 E 31 ATX Product Catalog

Photometric Data Continued: 36 W Versions with Polycarbonate Reflector: 1 x 36 W Efficiency 64.4% NF C 71-121: 0.64 E 2 x 36 W Efficiency 64.8% NF C 71-121: 0.64 E 3 x 36 W Efficiency 63.7% NF C 71-121: 0.63 F 58 W Versions with Polycarbonate Reflector: 1 x 58 W Efficiency 64.9% NF C 71-121: 0.65 E 2 x 58 W Efficiency 61.8% NF C 71-121: 0.62 E 3 x 58 W Efficiency 57.8% NF C 71-121: 0.58 E ATX Product Catalog 32