EARTH RESISTANCE DET24C

Similar documents
Application note. The APM-AMP meter can be connected in three different configurations:

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

The High Power Stack Horizon

2.0 CONSTRUCTION AND OPERATION 3.0 CHARACTERISTICS K. CO (HI-LO) Overcurrent Relay

Pre-lab Quiz/PHYS 224 Ohm s Law and Resistivity. Your name Lab section

ELECTRICAL MAINTENANCE

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE

Figure 1. Type CWP-1 Ground Relay (Front View) Figure 2. Type CWP-1 Ground Relay (Rear View) E

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY

University of Delaware

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay

41-747G. Figure 1: Type DGF Relay without case (Photo)

Pretest Module 24 Three-phase Service Entrance

EST Electrical Service Technician Answer Schedule

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

ComfortPoint Programmable Lon, VAV/Unitary Controllers

Electrical Wiring Practices

Electrical Design/Build Guide

University of Houston Master Construction Specifications Insert Project Name

Product Information Packet CP500808LR-4 800HP,897RPM,3PH,60HZ,G50,A95260M,TEFC,F

2014 ELECTRICAL TECHNOLOGY

Product Information Packet ECP50504L-4 500HP,1789RPM,3PH,60HZ,5010,TEFC,F1

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Wide-Vue Analog Panel Meters

Lab 9: Faraday s and Ampere s Laws

RF Point Level Control with Sensor Monitor

Your Name Lab Section

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

WYOMING STORAGE TANK PROGRAM GALVANIC (SACRIFICIAL ANODE) CATHODIC PROTECTION SYSTEM EVALUATION

B CW POWER RELAY

CHAPTER V RESIDENTIAL WIRING

Installation Data. Allen-Bradley 1336/1336VT/1336 PLUS/PLUS II/IMPACT 1336 FORCE Drives Dynamic Braking

Service Entrance Methods

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

IN2 Enclosed Switches and Circuit Breakers

UPPCO SERVICE MANUAL

Multi-Function Ground Resistance Tester Model 6472

3.6 KVA IsoG2. INSTALLATION INSTRUCTIONS & OWNER S MANUAL Model 93-ISOG26-A LT ISOG26 1. Issue 1 Print 3 SHORELINE ISOLATION TRANSFORMER

Utilization of Electric Power Laboratory 3 rd Year G2: Testing & Characteristic of MCCB Used in Commercial and Industrial Applications

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

For all of your Ground T esting needs. Technical Hotline: (800) Ground Testers

Outdoor Power Transmission & Distribution

3.0 CHARACTERISTICS E Type CO-4 Step-Time Overcurrent Relay

Sentinel Field Satellite Controller

Understanding National Electric Code (NEC) tap rules How do they apply to circuit breaker terminals?

EBP. Product Specifications. EBP Fan Coils 2 THRU 5 TONS SPLIT SYSTEM FEATURES. Model Number

COM Overcurrent Relay

SINGLE PHASE WIRING SPECIFICATIONS

Fall-of-Potential Ground Testing

THREE PHASE WIRING SPECIFICATIONS

KD LV Motor Protection Relay

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

L. Photo. Figure 2: Types CA-16 Relay (rear view) Photo. Figure 1: Types CA-16 Relay (front view)

C. Figure 1. CA-16 Front View Figure 2. CA-16 Rear View

SECTION MOTOR CONTROL

AIR COOLED RECTIFIER SPECIFICATION S-50-A

PERFORMANCE LOAD HP AMPERES RPM % % SPEED TORQUE RPM TORQUE TORQUE AMPERES % FULL LOAD LB-FT

Chapter 1 Electrical Theory...1

Generator Fire Safety: Generator assemblies should be located outside the building.

ESO 210 Introduction to Electrical Engineering

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Current Switches and Transducers

Wide-Vue Analog Panel Meters

MDS2 Series. Modular Distribution Systems. Introduction 8-Position Configuration Decision Tables

CSP Circuit Breaker Three Phase

ABB. Type CRQ Directional Negative Sequence Relay for Ground Protection B 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION CAUTION

Power Switching Devices

Simply reliable. ABB Single-phase Transformers. When transformation means safety and control.

National Marine Manufacturers Association Product Compliance Specialist Examination D.C. Electrical (2013 MY) ABYC E-11 (08 Amended 09)

3.8 KVA IsoG2. INSTALLATION INSTRUCTIONS & OWNER S MANUAL Model 93-ISOG2/8-A LT-ISOG28-1. Issue 1 Print 3 SHORELINE ISOLATION TRANSFORMER

Appendix C. Interval Every 2 Year. Functional Test Weekly Monthly Quarterly. Semi. Every 3. Engineering Studies

SECTION PANELBOARDS

South Dock Replacement Prescott Park. This addendum forms part of the original document marked: Bid#44-14 South Dock Replacement Prescott Park.

DIVISION 16 - ELECTRICAL SECTION 16xx0 MANUFACTURED WIRING SYSTEM ACCESS FLOOR

Electromagnetic Industries LLP

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS

AUTO PUMP 12V MODEL #: V 12 VOLT DC AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL. INPUT: Volts DC, 11 Amps OUTPUT: 100 PSI Max

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.

BATTERY SAVER LOW RIPPLE HO

Powerframes - Power Electronics

WARREN COUNTY, N.Y. M/E REFERENCE

3. OPERATION 2.1. RESTRAINT CIRCUIT 2.6. INDICATING CIRCUIT 2.2. OPERATING CIRCUIT 2.7. SURGE PROTECTION CIRCUIT 2.3.

Condensed Version of Operator s Manual For The VL600 Series Flowmeters

Spring Test 10 due 05/11/2013

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

SECTION SWITCHGEAR. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

Western Canada BLRBAC Conference Selecting the Right Power Supply and Electrode for a Recovery Boiler ESP

SECTION DC POWER SUPPLY/BATTERY CHARGER

Cutler-Hammer. Installation Instructions for the Digitrip OPTIM Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers

XM1 - Motor protection relay

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

PERFORMANCE - DELTA CONNECTION LOAD HP AMPERES RPM % % SPEED TORQUE - WYE / DELTA CONNECTION RPM TORQUE TORQUE AMPERES % FULL LOAD LB-FT 61 / 219

Motor Protection With The MonitorPro

Pentahead bolts See note 2. Conduit run as specified. Company facility. Refer to drawing SS8.6-2 or SS8.6-3 STANDARD SERVICE INSTALLATION

DIP SWITCH BASED EARTH LEAKAGE RELAY (ELR) WITH CORE BALANCE CURRENT TRANSFORMER (CBCT / ZCT) EL SERIES

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System

Transcription:

EARTH DET24C 1 AUTOMATED NUMBER OF TESTS: 1 SERIAL NO. CURRENT A TIME FILTER on/off INSTRUMENT SERIAL NO. TEST NOTES REVISED 9/4/2013

INTERSECTING CURVES 2 GENERAL NUMBER OF GROUND RODS INCHES AWG DIAGONAL MEASUREMENT OF GROUND GRID GROUND TESTER MAKE/MODEL GROUND TESTER SERIAL NUMBER LAST CALIBRATION PROBE PLACEMENT DIRECTION DISTANCE FROM C TO O (P) TEST 1 () (P) TEST 2 () (P) TEST 3 () 1 2 3 4 5 6 7 8 9 10 Measurement process is repeated with three different values for D c. 24470, 1 OF 3, REVISED 7/15/2010

INTERSECTING CURVES FALL OF POTENTIAL CURVE: O TO C = 3 (ohms) FALL OF POTENTIAL CURVE: O TO C = (ohms) FALL OF POTENTIAL CURVE: O TO C = (ohms) 24470, 1 OF 3, REVISED 7/15/2010

INTERSECTING CURVES 4 ARBITRARY X DISTANCE 0 TEST 1 TEST 2 TEST 3 D p D p D p 100 200 300 400 500 600 700 800 VERSUS X DISTANCES (O to C =, and ) (ohms) RESULT: 24470, 1 OF 3, REVISED 7/15/2010

SIMPLIFIED FALL OF POTENTIAL 5 GENERAL NUMBER OF GROUND RODS INCHES AWG DIAGONAL MEASUREMENT OF GROUND GRID GROUND TESTER MAKE/MODEL GROUND TESTER SERIAL NUMBER LAST CALIBRATION PROBE PLACEMENT DIRECTION DISTANCE FROM GROUND ELECTRODE TO C IN DESIRED ACCURACY R1 R2 R3 PERCENT OF OVERALL DISTANCE 40.00 50.00 60.00 (GROUND ELECTRODE TO P) 0.0 0.0 0.0 READING () DEVIATION 0.00 0.00 0.00 R avg 0.00 MAX DEVIATION ACCURACY RESULT () 0.00 0.0 RETEST 24420, REVISED 7/7/2010

FULL FALL OF POTENTIAL 6 GENERAL NUMBER OF GROUND RODS INCHES AWG DIAGONAL MEASUREMENT OF GROUND GRID GROUND TESTER MAKE/MODEL GROUND TESTER SERIAL NUMBER LAST CALIBRATION PROBE PLACEMENT DIRECTION DISTANCE FROM GROUND ELECTRODE TO C IN EARTH CURVE (GROUND ELECTRODE TO P) PERCENT OF OVERALL DISTANCE READING (Ohms) () DISTANCE FROM GROUND ELECTRODE TO P () RESULT: 24400, REVISED 1/17/2011

FALL OF POTENTIAL 61.8 RULE 7 GENERAL NUMBER OF GROUND RODS INCHES AWG DIAGONAL MEASUREMENT OF GROUND GRID GROUND TESTER MAKE/MODEL GROUND TESTER SERIAL NUMBER LAST CALIBRATION PROBE PLACEMENT DIRECTION (GROUND ELECTRODE TO C) PERCENT OF OVERALL DISTANCE (GROUND ELECTRODE TO P) READING () DISTANCE #1 61.8 DISTANCE #2 DISTANCE #3 61.8 61.8 24460, REVISED 7/7/2010

SOIL RESISTIVITY 8 GENERAL NUMBER OF GROUND RODS INCHES AWG DIAGONAL MEASUREMENT OF GROUND GRID GROUND TESTER MAKE/MODEL GROUND TESTER SERIAL NUMBER LAST CALIBRATION PROBE PLACEMENT DIRECTION Soil Resistivity (ohm-cm) = 2 * PI * Distance Between Electrodes (cm) * Resistance (ohms) LOCATION IDENTIFIER DISTANCE BETWEEN ELECTRODES (feet) DISTANCE BETWEEN ELECTRODES (cm) ELECTRODE DEPTH (inches) SOIL RESISTIVITY (ohms) (ohm-cm) Measures average soil resistivity at this one point. 24440, REVISED 7/7/2010

STAR DELTA 9 GENERAL NUMBER OF GROUND RODS INCHES AWG DIAGONAL MEASUREMENT OF GROUND GRID GROUND TESTER SERIAL NUMBER GROUND TESTER MAKE/MODEL LAST CALIBRATION READING () R12 R13 R14 R23 R34 R1 R2 R3 R4 OF THE GROUND ELECTRODE UNDER TEST OF PROBE P2 OF PROBE P3 OF PROBE P4 R42 EQUATION R1 RESULT R2 RESULT R3 RESULT R4 RESULT #1 #2 #3 Resistance Areas #4 24450, REVISED 7/7/2010

SLOPE METHOD 10 GENERAL NUMBER OF GROUND RODS INCHES AWG DIAGONAL MEASUREMENT OF GROUND GRID GROUND TESTER MAKE/MODEL GROUND TESTER SERIAL NUMBER LAST CALIBRATION PROBE PLACEMENT DIRECTION DISTANCE FROM GROUND ELECTRODE TO C IN Interpolate Result Measure Result "P" PROBE PERCENT OF OVERALL DISTANCE (GROUND ELECTRODE TO P) READING () SLOPE CHANGE /DISTANCE CURVE P T / C R1 20.00 C 0.0 P T / (ft) 0.0 R2 40.00 C 0.0 RESULT (ohms): 0.00 R3 60.00 C 0.0 24430, REVISED 7/7/2010

FOUR POTENTIAL METHOD 11 GENERAL NUMBER OF GROUND RODS INCHES AWG DIAGONAL MEASUREMENT OF GROUND GRID GROUND TESTER MAKE/MODEL GROUND TESTER SERIAL NUMBER LAST CALIBRATION PROBE PLACEMENT DIRECTION DISTANCE FROM GROUND ELECTRODE TO C IN R1 R2 PERCENT OF OVERALL DISTANCE 20.00 40.00 (GROUND ELECTRODE TO P) GROUND () EQUATION #1 EQUATION #2 EQUATION #3 EQUATION #4 R R R R RESULT RESULT RESULT RESULT R3 50.00 R4 60.00 R5 70.00 R6 80.00 EQUATION #1 (R ) = EQUATION #2 (R ) = EQUATION #3 (R ) = EQUATION #4 (R ) = -0.1187R1-0.4667R2 + 1.9816R4-0.3961R6-2.6108R2 + 4.0508R3-0.1626R4-0.2774R6-1.8871R2 + 1.1148R3 + 3.6837R4-1.9114R5-6.5225R3 + 13.6816R4-6.8803R5 + 0.7201R6 24410, REVISED 7/7/2010

GROUNDED SURFACES TEST SINGLE ROOM 12 GROUND REFERENCE ITEM MILLIVOLT READING ITEM MILLIVOLT READING MAXIMUM ALLOWABLE VALUE IS 20 MILLIVOLTS FOR NEW CONSTRUCTION PER THE NATIONAL FIRE PROTECTION ASSOCIATION NFPA-99, 1996, 3-3.3.2.6. 25100, REVISED 4/22/2009

GROUND ROD SURVEY 13 ROD NUMBER LOCATION OR IDENTIFICATION ROD SIZE D X L COPPER CLAD STEEL OR GALVANIZED CONNECTING CONDUCTOR SIZE * * TEST METHOD USED FOR DETERMINING GROUND ROD : 2 POINT 3 POINT CLAMP-ON REFERENCE GROUND 24300, REVISED 4/22/2009

GROUND TWO TERMINAL METHOD 14 DRAWING REFERENCE NUMBER FROM TEST # TO UNCORRECTED CORRECTED RESULT MILLI- MILLI- MILLI- MILLI- MILLI- MILLI- MILLI- MILLI- MILLI- MILLI- MILLI- MILLI- MILLI- MILLI- MILLI- MILLI- MILLI- MILLI- MILLI- MILLI- MILLI- MILLI- MILLI- MILLI- MILLI- MILLI- MILLI- 24210, REVISED 4/22/2009

GROUND MAT TEST 15 NUMBER OF RODS CURRENT TRANSFORMER TYPE: WINDOW: STYLE: BAR TYPE SOLID ROUND SPLIT CORE RECTANGULAR AUXILIARY POTENTIAL ELECTRODE IN GROUND @ 61.8 OF DISTANCE TEST TYPE: FALL OF POTENTIAL TWO-POINT INDUCED FREQUENCY 24020, REVISED 4/22/2009

GROUND MAT TEST 16 NUMBER OF RODS CURRENT TRANSFORMER TYPE: WINDOW: STYLE: BAR TYPE SOLID ROUND SPLIT CORE RECTANGULAR AUXILIARY POTENTIAL ELECTRODE IN GROUND @ 61.8 OF DISTANCE TEST TYPE: FALL OF POTENTIAL TWO-POINT INDUCED FREQUENCY 24000, REVISED 4/22/2009

LINE ISOLATION MONITOR SYSTEM TEST 17 NAMEPLATE DATA MANUFACTURER MODEL NO. INPUT VOLTAGE CATALOG NO. OUTPUT VOLTAGE SERIAL NO. TYPE ALARM CURRENT PICKUP INDICATOR TESTS DESCRIPTION INSPECTED CONDITION DESCRIPTION INSPECTED CONDITION SAFE LIGHT HAZARD LIGHT PUSH TO TEST PUSH TO TEST SILENCE SELF CALIBRATION METER READING - CIRCUITS ON METER READING - CIRCUITS OFF ma ma VOLTAGE TESTS NO LOAD PRIMARY VOLTAGE H1-GROUND V H1-H2 V H2-GROUND V H2-H3 V H3-GROUND V H3-H1 V X1-GROUND X2-GROUND X3-GROUND NO LOAD SECONDARY VOLTAGE V X1-X2 V V X2-X3 V V X3-X1 V HAZARD LEAKAGE CURRENT TESTS - BRANCH CIRCUITS VOLTAGE TESTS L1-GND L2-GND PANEL LEAKAGE ( µ A) ( µ A) BRANCH CKT. BREAKERS OFF BRANCH CKT. BREAKERS ON (LOADS ARE REMOVED OR OFF) LIM TRIP LEVEL TEST LIM METER READING EXTERNAL METER READING L1-GND (ma) SHADED AREAS FOR 3-PHASE SYSTEMS ONLY L2-GND (ma) L3-GND ( µ A) L3-GND (ma) CIRCUIT NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 LEAKAGE LEAKAGE LEAKAGE CURRENT CURRENT CURRENT L1-GND ( µ A) L2-GND ( µ A) L3-GND ( µ A) 26000, REVISED 4/22/2009

GROUNDED SURFACES TEST MULTI-ROOM 18 GROUND REFERENCE ITEM MILLIVOLT READING RM RM RM RM RM MAXIMUM ALLOWABLE VALUE IS 20 MILLIVOLTS FOR NEW CONSTRUCTION CRITICAL CARE AREAS, AND 500 MILLIVOLTS FOR GENERAL CARE AREAS PER NFPA-99, 1996, 3-3.3.2.6, CRITERIA FOR ACCEPTABILITY. 25000, REVISED 4/22/2009

GROUND POINT CONTINUITY TEST 19 General Description: Maximum Resistance Test # Description Test Amps A Volts V Calc. Resist. (ohms) Lead Resist. (ohms) Ground Resist. (ohms) Com. Test # Description Test Amps A Volts V Calc. Resist. (ohms) Lead Resist. (ohms) Ground Resist. (ohms) Com. 24220, REVISED 11/21/2013

FALL OF POTENTIAL TEST 20 NUMBER OF GROUND RODS INCHES AWG DIAGONAL MEASUREMENT OF GROUND GRID GROUND TESTER MAKE/MODEL GROUND TESTER SERIAL NUMBER LAST CALIBRATION POINT UNDER TEST DIRECTION OF ELECTRODES DISTANCE C1 TO C2 DISTANCE P1 TO P2 PERCENT P TO C MEASURED R 40 OHM(S) R 50 OHM(S) R 60 OHM(S) R OHM(S) R OHM(S) RA EQUALS AVERAGED ( R40 R 50 R 60 ) : OHM(S) R 60 MINUS RA DIVIDE BY RA EQUALS X PERCENT X PERCENT TIMES 1.2 EQUALS Y PERCENT IF Y PERCENT IS LESS THAN YOUR DESIRED TEST ACCURACY, RA CAN BE USED AS THE REST RESULT. 24010, REVISED 4/22/2009

GROUND RESISTIVITY TEST 21 TEST ELECTRODE DEPTH INCHES TEST ELECTRODE SPACING TEST PLOT ID METER READING () CALCULATED RESISTIVITY ( - CM) TEST PLOT ID METER READING () CALCULATED RESISTIVITY ( - CM) TEST PLOT ID METER READING () CALCULATED RESISTIVITY ( - CM) ρ - SOIL RESISTIVITY IN OHM CENTIMETERS RESISTIVITY CALCULATION N: ρ = 2 πα R Α - DISTANCE BETWEEN TEST ELECTRODES IN F R - IN CENTIMETERS = (INCHES) ( 2.54 ) CENTIMETERS = () ( 12 ) ( 2.54 ) 24200, REVISED 4/22/2009