ARB UTILITY MANAGEMENT SYSTEMS WATER GAS ELECTRIC. HP Fire Service Turbine Installation and Maintenance Guide

Similar documents
neptunetg.com Neptune Technology Group Inc Alabama Highway 229 Tallassee, AL USA Tel: (800) Fax: (334)

TRU/FLO Compound Installation and Maintenance Guide

HP Turbine Installation and Maintenance Guide

E-Coder)R900i Quick Install Guide. E-CODER)R900i QUICK INSTALL GUIDE

ZTM AND ZTMB ZENNER TURBINE METERS INSTALLATION, MAINTENANCE AND SERVICING

Flow Control Valve IOM 770-U

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

Surface CIMV, Low Flow, HTV, Manual

Type EZR Relief Valve or Backpressure Regulator

PRESSURE RELIEF VALVE

Operation and Maintenance Manual

SINGLE ACTING ALTITUDE VALVE

Installation, Maintenance, & Repair Series 919 and LF919

Type EZR Relief Valve or Backpressure Regulator

PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

ERHARD is a company of. Data sheet ERHARD needle valves

EZ-IN Series Turbine Flowmeter

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

IMPORTANT!!!! Read this manual before attempting any installation, wiring or operation.

INSTRUCTION MANUAL INSTALLATION OPERATION TROUBLESHOOTING MAINTENANCE PRESSURE RELIEF VALVE WITH SURGE ANTICIPATION (HYDRAULIC) FEATURE MODEL 50RWR-A

Pilot-Operated Regulators

Technical Data TYPE A SERIES AIR ADJUSTED PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4011 OPERATING PRINCIPLE

Y690A Series Pressure Reducing Regulators

IFOA Integral Flow Orifice Assembly

Pneumatic Actuator. Operation & Service Manual. Models: Original Instructions UNIBLOC PUMP MANUAL NO.: REVISION: 08/2016

ARB UTILITY MANAGEMENT SYSTEMS WATER ELECTRIC GAS. E-Coder)R900i Quick Install Guide. E-Coder)R900i QUICK INSTALL GUIDE

FIRE HYDRANTS. Wet Barrel Fire Hydrants

MUELLER GAS. Shur StopTM Unit 812 PE Line Stopping. System 8" 12" SDR Reliable Connections. General Information 2

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P

INSTALLATION & MAINTENANCE MODEL mm

Industrial Turbo Meters, Sizes 2" through 6"

Sprayer Control. Manual for SprayLink Cable Installations. Tank. Jet Agitator. Agitator Valve. Diaphragm Pump. Pressure Transducer.

NIAGARA. Series WPX. Installation, Operation & Maintenance Manual. Models 210 and 222. Series WPX

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

INSTALLATION INSTRUCTIONS

IOM IR-910M0-X. Hydrometer Magnetic Drive with solenoid control

PEB & PESB Valve Installation and Operating Instructions Troubleshooting Guide

720G Wafer and 821G Globe Style Silent Check Valves

Flow Control & Pressure Reducing Valve with Hydraulic Control (Sizes 3''- 12"; DN80-DN300)

Installation Instructions

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

AUTOMATIC FLOW CONTROL VALVE. INSTRUCTIONS Installation - Operation - Inspection - Maintenance

Y690A Series Pressure Reducing Regulators

Recordall Combo Meter Lead-Free Bronze Alloy, Size 8" (DN 200) NSF/ANSI Standards 61 and 372 Certified RCO-UM EN-02 (October 2013) User Manual

Hopkinsons Fig 9052 VALVE ACTUATOR

Retractable System Operation & Maintenance Manual

PRESSURE REDUCING CONTROL VALVE

F76 Water Filters. Specifications. and MV876 Automatic-Backwash Control Accessory (not included)

Series Roll Seal

User Manual. Recordall Compound Series Meter. Lead-Free Bronze Alloy, Sizes 2", 3", 4" & 6" NSF/ANSI Standards 61 and 372 Certified

720A Wafer & 821A Globe Style

TYPE E Main Valve Sizes 3 /8 through 12

SEALING DIP CAP INSTALLATION GUIDE

Metso High Consistency Sampler Metso Nove H. Installation & Owner s Manual K10196 V1.1 EN

Operating and Maintenance Manual for Type S Flowmeters. M101 Rev. B Type S Flowmeters: 5 8, 3 4 and 1 with 157 & 600 Series Registers

FIXED DEPTH INSERTION METER INSTRUCTIONS

ROOTS Meters Series B3 Meter Models 8C175-56M175

PRESSURE REDUCING VALVE

METERING VALVE 2" STEM GUIDED

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

I N S T R U C T I O N M A N U A L

TFA Flowmeter for Saturated Steam Service Installation and Maintenance Instructions

NUMBER: rev S.M. REF.: Refer to 2.47 ENGINE: 50 DATE: June 2001

Maintenance Manual Reduced Pressure Assembly Models 860 & 880V 2 1 /2" 10"

LEVEL AND FLOW MEASUREMENT WS131 FLOW METER USER MANUAL.

DEMA 652 DUO-FEED INSTALLATION INSTRUCTIONS

Installation Instructions

Pressure Reducing Valve Type 2114/2415

OPERATION AND MAINTENANCE MANUAL 2-66 SERIES 2500 RESILIENT WEDGE GATE VALVE

Crispin Valves Operating Guide. Crispin

DO NOT INSULATE BELOW THIS LINE. * For sizes 1/2" to 1 1/2" add 2 1/2" to 'C' dimension.

CSO/STORMWATER MANAGEMENT. HYDROVEX Turbo Flow Regulator

Installation, Maintenance, & Repair Series 995 Reduced Pressure Zone Backflow Preventers

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP

LIQUID MEASUREMENT STATION DESIGN Class No

Installation Operation & Maintenance Instructions

User s Manual OM th edition

FUNDAMENTALS OF ORIFICE METERING Ken Embry FMC Measurement Solutions

Armstrong Double Duty 6 Steam Trap/Pump Combination Installation and Maintenance

HTX-HTH SEPARATORS I&O MANUAL

RAMMER BT1400, BT1600 PARTS BOOK

GT-200 GATE VALVES PN16, Screwed end

I & M Mark 708ME. Ideal Installation. Start-Up Procedure. Installation & Maintenance Instructions for Mark 708 & Motor Actuator

Liquid Turbine Flowmeter

Product Data Sheet. Recordall Fire Series Assemblies (FSAA) Cold Water Meter & Strainer with Disc Bypass DESCRIPTION

I & M 8000 Series. Ideal Installation Schematic. Preferred Installation. Trouble Shooting

4-20 ELECTRONIC VERTICAL FLOW METERS

PRESSURE REDUCING VALVE

PRESSURE REDUCING VALVE

Type N550 Snappy Joe Emergency Shutoff Valves

DEMA 651AG SINGLE-FEED INSTALLATION INSTRUCTIONS

AMERICAN AVK COMPANY AVK SERIES 67 - HIGH PRESSURE, POST/FLUSHING HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS

Type 644 and 645 Differential Pressure Pump Governors

Technical Data TYPE T124 & T134 TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4512A

Series 007. Double Check Valve Assembly. Installation Service Repair Kits Maintenance. Sizes: 1 2" 3" Watts 3 4" 007M3QT RP/IS-007

1 Engine and peripherals

Product Data Sheet. Recordall Fire Series Assembly (FSAA) Cold Water Meter & Strainer with Turbine Bypass DESCRIPTION

RUN ACCUM. TOTAL STOP BAT LOW HIGH

Transcription:

ARB UTILITY MANAGEMENT SYSTEMS WATER GAS ELECTRIC HP Fire Service Turbine Installation and Maintenance Guide HP FIRE SERVICE TURBINE INSTALLATION AND MAINTENANCE GUIDE

ARB UTILITY MANAGEMENT SYSTEMS WATER GAS ELECTRIC HP Fire Service Turbine Installation and Maintenance Guide

This manual is an unpublished work and contains the trade secrets and confidential information of Neptune Technology Group Inc., which are not to be divulged to third parties and may not be reproduced or transmitted in whole or part, in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of Neptune Technology Group Inc. All rights to designs or inventions disclosed herein, including the right to manufacture, are reserved to Neptune Technology Group Inc. Neptune engages in ongoing research and development to improve and enhance its products. Therefore, Neptune reserves the right to change product or system specifications without notice. Trademarks Used in this Manual Neptune is a registered trademark of Neptune Technology Group Inc. Other brands or product names are the trademarks or registered trademarks of their respective holders. Neptune Technology Group Inc. 1600 Alabama Highway 229 Tallassee, AL 36078 USA Tel: (800) 645-1892 Fax: (334) 283-7299 Neptune Technology Group (Canada) Ltd. 7275 West Credit Avenue Mississauga, Ontario L5N 5M9 Canada Tel: (905) 858-4211 Fax: (905) 858-0428 Neptune Technology Group Inc. Ejército Nacional No. 418 Piso 12, Desp. 1201-1202 Col. Chapultepec Morales Delegación Miguel Hidalgo 11570 México, Distrito Federal Tel: (525) 55203 5294 / (525) 55203 5708 Fax: (525) 55203 6503 HP FIRE SERVICE TURBINE INSTALLATION AND MAINTENANCE GUIDE Literature No. IM FSTURB 08.08 Copyright 2008, Neptune Technology Group Inc. All rights reserved.

CONTENTS 1 OVERVIEW Contacting Technical Support... 1-1 2 INSTALLATION INSTRUCTIONS Installation Instructions...2-1 Recommended Installation...2-1 Before Operation...2-2 3 MAINTENANCE Maintenance Instructions...3-1 Turbine...3-1 Adjusting the Calibration Vane...3-2 Strainer...3-2 HP FIRE SERVICE TURBINE INSTALLATION AND MAINTENANCE GUIDE iii

NOTES iv HP FIRE SERVICE TURBINE INSTALLATION AND MAINTENANCE GUIDE

CHAPTER 1 OVERVIEW CHAPTER 1 OVERVIEW The High Performance Fire Service Turbine is designed to measure water usage through a designated fire service line or through a single line that serves both fire and domestic use where flow rates are moderate to high. In order to achieve maximum performance in actual service, it is essential that these installation and maintenance instructions be followed. CONTACTING TECHNICAL SUPPORT If you encounter any problems with the installation or operation of your HP Fire Service Turbine, please call Neptune at (334) 283-6555 or 1-800-645-1892 and ask to speak with Customer Support. HP FIRE SERVICE TURBINE INSTALLATION AND MAINTENANCE GUIDE 1-1

NOTES 1-2 HP FIRE SERVICE TURBINE INSTALLATION AND MAINTENANCE GUIDE

CHAPTER 2 INSTALLATION INSTRUCTIONS This chapter is designed to take you through the installation process for the HP Fire Service Turbine. CHAPTER 2 INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS The HP Fire Service Turbine meter will operate more accurately and reliably if installed and maintained properly. Fire Service Turbine meter performance is directly related to the flow conditions of the water entering the turbine measuring element. The entering flow is properly conditioned by a strainer installed immediately upstream of the turbine meter. The HP Fire Service Turbine meter includes the required UL listed and FM approved basket-type strainer attached to the inlet of the fire service turbine. The strainer, in addition to protecting the meter from rocks and debris in the line, also corrects the velocity profile of the flow to the turbine meter reducing the effects of upstream piping variations. Proper service and cleaning of the strainer is important for long term reliability and performance of the turbine measuring element. RECOMMENDED INSTALLATION The recommended installation of the fire service turbine meter is in a horizontal position with its arrow pointing in the direction of the water flow. When installing Neptune meters with a strainer, a minimum of two (2) to four (4) pipe diameters of straight run pipe (can include components that are fully open in their normal operating position) is required upstream and downstream of the meter/strainer assembly. If a Neptune meter is installed without a strainer, a minimum of eight (8) pipe diameters of straight run pipe (can include components that are fully open in their normal operating position) is required upstream and two (2) to four (4) pipe diameters of straight run pipe downstream of the meter/strainer assembly. Installation of a test tee is advised as it provides a means to field test the meter without removing it from the line. The test tee may be installed where the test outlet is at least two pipe diameters or more downstream of the water meter outlet. A full size bypass around the meter is also recommended as it provides uninterrupted service capability during meter servicing periods. When installing a fire service turbine meter, normal good piping practice should always be followed. In particular, all gaskets should be centrally located on their flanges with no overlap or interference with the pipe diameter. The fire service turbine meter must operate in a completely filled line at all times. The downstream piping must always provide sufficient back pressure to maintain a full line at the meter. Caution should be exercised to avoid air in the line, or excessive flow rates for extended periods of time. HP FIRE SERVICE TURBINE INSTALLATION AND MAINTENANCE GUIDE 2-1

CHAPTER 2 INSTALLATION INSTRUCTIONS BEFORE OPERATION Before putting the fire service turbine meter into service, follow these steps: 1 Close both the inlet and outlet gate valves. 2 Turn air bleed screw on strainer cover counter-clockwise one to two turns. 3 Slowly open inlet side gate valve to pressurize meter. 4 Close air bleed screw (clockwise) when air is completely vented and no spitting occurs. 5 Slowly open outlet side gate valve until downstream line is pressurized. After installation, it is important that the upstream (inlet) valve be put in the full open position during service. All throttling should be done only on the downstream (outlet) side of the meter. 2-2 HP FIRE SERVICE TURBINE INSTALLATION AND MAINTENANCE GUIDE

CHAPTER 3 MAINTENANCE CHAPTER 3 MAINTENANCE If you find that your HP Fire Service Turbine is not operating as expected when installed, use the following guidelines to try to determine the source of the problem. MAINTENANCE INSTRUCTIONS TURBINE When maintenance is necessary, the complete unitized measuring element (UME) may be quickly and easily interchanged with a factory-calibrated unit by following these steps: 1 Close both the inlet and outlet gate valves. 2 Remove cover bolts from the turbine. 3 Remove cover and turbine measuring element from maincase. 4 Install factory-calibrated UME into maincase. 5 Replace cover bolts. 6 Tighten cover bolts. 7 Follow steps 2 through 5 from Before Operation section above. All UMEs have been factory-calibrated and should not require field calibration. The complete UME should be tapped and returned for service to the Neptune factory. If the customer does not have a spare unit, a factory-calibrated UME may be purchased directly from Neptune or one of its authorized distributors. Neptune encourages all customers to purchase either a spare UME or a blank cover to enable them to avoid service interruptions. HP FIRE SERVICE TURBINE INSTALLATION AND MAINTENANCE GUIDE 3-1

CHAPTER 3 MAINTENANCE ADJUSTING THE CALIBRATION VANE Neptune equips all new turbine meters and UMEs with a calibration vane. Should field calibration of the turbine element be required, the following steps should be followed: 1 Remove seal pin from register and twist off register. 2 Loosen lock nut on adjusting stem by turning counter-clockwise. 3 Insert slotted screwdriver into slot in top of adjusting stem, and (a) turn clockwise to decrease registration, or (b) turn counter-clockwise to increase registration. Turning the adjustment stem 15º in either direction results in approximately one percent change in registration. The full range of the calibration vane is 180. Figure 3.1 Calibration Vane STRAINER For maximum efficiency, determine length of time it takes for baskets to become approximately one-third clogged. Remove top cover and clean basket. Replace basket in strainer in original position and tighten cover. Replace gasket if necessary. Spare gaskets will facilitate shorter shutdown time. Pressure gauge installed before and after strainer in line will indicate pressure loss due to clogging and may be used as a guide to determine when cleaning is required. Strainer is equipped with a flushing port and open bottom basket for removal of sediment. In addition, strainer may be equipped with a blow-down valve to facilitate easier cleaning 3-2 HP FIRE SERVICE TURBINE INSTALLATION AND MAINTENANCE GUIDE

NOTES HP FIRE SERVICE TURBINE INSTALLATION AND MAINTENANCE GUIDE 3-3

NOTES 3-4 HP FIRE SERVICE TURBINE INSTALLATION AND MAINTENANCE GUIDE

Neptune Technology Group Inc. 1600 Alabama Highway 229 Tallassee, AL 36078 USA Tel: (800) 645-1892 Fax: (334) 283-7299 Neptune Technology Group (Canada) Ltd. 7275 West Credit Avenue Mississauga, Ontario L5N 5M9 Canada Tel: (905) 858-4211 Fax: (905) 858-0428 Neptune Technology Group Inc. Ejército Nacional No. 418 Piso 12, Desp. 1201-1202 Col. Chapultepec Morales Delegación Miguel Hidalgo 11570 México, Distrito Federal Tel: (525) 55203 5294 / (525) 55203 5708 Fax: (525) 55203 6503 neptunetg.com IM FSTURB 08.08 Copyright 2008, Neptune Technology Group Inc. Neptune is a registered trademark of Neptune Technology Group Inc.