GMH8/GDH8. Two-Stage Convertible Multi-Speed Gas Furnaces 80% AFUE

Similar documents
DD80HS. Two-Stage, Convertible Multi-Speed Gas Furnace 80% AFUE. Heating Input: 40, ,000 BTU/h

GMS8/GDS8/GHS8. Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

DM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h

VMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

AMS8 / ADSS8. Single-Stage Multi-Speed Gas Furnaces 80% AFUE. Heating Input: 40, ,000 BTU/h

AMS8/ADSS8. Single-Stage. Heating Input: 40, ,000 BTU/h

GMS8/GDS8/GHS8 Multi-Position, Multi-Speed Gas Furnaces

Multi-Position, Multi-Speed Gas Furnaces

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

GMSS92 / GCSS92 Single-Stage Multi-Speed Gas Furnace

GKS9 Series. Upflow Multi-Position, Multi-Speed Gas Furnace. Heating Input: 46, ,000 BTU/h

AKSS92. Single-Stage. Heating Input: 46, ,000 BTU/h. up to 92.1% AFUE

GKS9 Series. up to 92.1% AFUE. Upflow Multi- Position, Multi-Speed Gas Furnace. Heating Input: 46, ,000 BTU/h

GMS9/GCS9 SERIES 93% AFUE

Cabinet Features. upflow, horizontal left or right matically adjusts to high or low stage

GMH95/GCH9 PRODUCT SPECIFICATIONS 95%/93% AFUE HEAT REPLACEMENT MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE

PRODUCT SPECIFICATIONS GMS8/GDS8/GHS8 SERIES 80% AFUE MULTI-POSITION, SINGLE-STAGE/MULTI-SPEED GAS FURNACE

GMH8/GDH8 MULTI-POSITION, MULTI-SPEED GAS FURNACES 80% AFUE HEATING INPUT: 40, ,000 BTU/H. Standard Features. Cabinet Features.

DM96HS / DC96HS. Hybrid Two-Stage Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

DC96HS TWO-STAGE CONVERTIBLE MULTI-SPEED GAS FURNACE UP TO 96% AFUE. Heating Input: 46, ,000 BTU/h

GKS9 SERIES PRODUCT SPECIFICATIONS 92.1% AFUE SINGLE-STAGE/MULTI-SPEED GAS FURNACE UPFLOW/MULTI-POSITION HEATING INPUT: 46, ,000 BTU/H

95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES

PGC COMMERCIAL PACKAGED GAS/ELECTRIC

TECHNICAL GUIDE 80 AFUE DOWNFLOW GAS-FIRED FURNACES MODELS: G8T-DN DESCRIPTION WARRANTY FEATURES Rev. B (0303)

GCEC96. Two-Stage, Multi-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES DESCRIPTION WARRANTY FEATURES Rev.

Cooling Capacity CFM in. w.c. (125 Pa)

A95-2V. 95% Gas Furnaces Two-Stage Variable Speed HEAT EXCHANGER DESIGN CONFIGURATIONS

TECHNICAL GUIDE MODELS: P4HU 80 AFUE MULTI-POSITION GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger.

TECHNICAL GUIDE MODELS: P4DN 80 AFUE DOWNFLOW GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger.

DC96VE. Two-Stage, Multi-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN

G8MVL. Product Specifications

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )

AMEC96. Heating Input: 30, ,000 BTU/h

Product Data. that this product meets the S 95% AFUE S Two -stage operation

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

96G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

N9MSB. PS 92 Product Specifications. 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL /2/17

FG7T (A and K Series)

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

Cooling Capacity CFM in. w.c. (125 Pa)

95% Gas Furnaces A95-1E. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits CONFIGURATIONS

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

95G1-E. Aluminized steel primary heat exchanger with crimped non-welded construction AL 29-4C Stainless steel secondary heat exchanger

Cooling Capacity CFM in. w.c. (125 Pa)

95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

Cooling Capacity CFM in. w.c. (125 Pa)

95% Gas Furnaces. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 95G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

Rheem Classic Plus Series Downflow Gas Furnace

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

KG7T (E and N Series)

FG7T (E and N Series)

G9MXE. Product Specifications

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

80% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor

G9MXE. Product Specifications

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH

AF90. AF90 Gas Furnace High Efficiency. Features

UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS)

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE

FG7T (A and K Series)

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)

F8MTL. Product Specifications

80% Gas Furnace. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 80G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNERS

ARUF Series Multi-Position

TSTAT0101SC Recommended (sold separately)

Rheem Classic Series Downflow Gas Furnace

Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace

GMEC96. Two-Stage, Multi-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 30, ,000 BTU/h

APD14. Packaged Dual-Fuel Units Up to 14.5 SEER 81% AFUE / 8.0 HSPF

Rheem Value Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Super Quiet 80 Upflow/Horizontal Gas Furnace

Table of Contents GF801U Series

Multi-Position Air Handler. 1½ to 5 Tons. with Energy-Saving Motor

AWUF Series. Wall-Mount Air Handler 1½- to 3-Tons

92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER CABINET DESIGN AIR DELIVERY SYSTEM CONTROLS VENTING

80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN

GMEC96. Two-Stage, Multi-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 30, ,000 BTU/h

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1

Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace

Upflow, Upflow / Horizontal, Counterflow / Horizontal

93% Gas Furnaces Single Stage

FG7S (C and L Series)

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev.

WFSR. Product Specifications 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

A951E PRODUCT SPECIFICATIONS CONTROLS VENTING INSTALLATION FEATURES CONFIGURATIONS WARRANTY HEAT EXCHANGER DESIGN BURNER CABINET DESIGN

TECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

GAS FURNACES II 80.0% 81.4% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES SILHOUETTE

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

GAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES

Transcription:

/ Two-Stage Convertible Multi-Speed Gas Furnaces 80% AFUE Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 5 Airflow Data... 7 Wiring Diagram... 10 Accessories... 11 Minimum Filter Sizes... 11 Standard Features Heavy-duty aluminized-steel dualdiameter, tubular heat exchanger Two-stage convertible gas valve automatically adjust to high or low stage Durable Silicon Nitride igniter Quiet single speed draft inducer Self-diagnostic control board with constant memory fault code Color-coded low-voltage terminals with provisions for electronic air cleaner and humidifier Multi-speed blower motor Low continuous fan speed options offer quiet air circulation California Low NOx emissions standards models available Cabinet Features Multi-position installation: : upflow, horizontal left or right : dedicated downflow Convenient left or right connection for gas and electrical service Cabinet air leakage (QLeak) 2% Heavy-gauge steel cabinet with durable baked-enamel finish Fully insulated heat exchanger and blower section * Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec. SS- www.goodmanmfg.com 10/15 Supersedes 5/14

Nomenclature G M H 80 040 3 B X A A 1 2 4 5,6 7,8,9 10 11 12 13 14 Brand Minor Revision G - Goodman Brand A - Initial Release B - First Revision Configuration C - Downflow/Horizontal Major Revision D - Dedicated Downflow A - Initial Release M - Upflow/Horizontal B - First Revision Gas Valve NOx E - Multi- Speed ECM N - Natural Gas H - Convertible Two- Stage, Single Phase X - Low NOx S - Single Stage, Single Speed Cabinet Width AFUE A - 14" C - 21" 80-80% AFUE B - 17½" D - 24½" MBTU/h Maximum CFM 040-40,000 BTU/h 100-100,000 BTU/h 3-1200 CFM 060-60,000 BTU/h 120-120,000 BTU/h 4-1600 CFM 080-80,000 BTU/h 140-140,000 BTU/h 5-2000 CFM 2 www.goodmanmfg.com SS-

Product Specifications 0403A*B 0603A*B 0604B*B 0803B*B 0804B*B 0805C*B 1005C*B 1205D*B 1405D*B Heating Capacity Input 40,000 60,000 60,000 80,000 80,000 80,000 100,000 120,000 140,000 Natural Gas Output 32,000 48,000 48,000 64,000 64,000 64,000 80,000 96,000 112,000 LP Gas Output 32,000 48,000 48,000 64,000 64,000 64,000 80,000 96,000 96,000 AFUE ¹ 80 80 80 80 80 80 80 80 80 Available AC @ 0.5 ESP 3 3 4 3 4 5 5 5 5 Temperature Rise Range ( F) 25-55 20-50 20-50 35-65 35-65 35-65 35-65 40-70 40-70 Circulator Blower Size (D x W) 10 x 6 10 x 6 10 x 8 10 x 8 10 x 8 10 x 10 10 x 10 11 x 10 11 x 10 Horsepower @1075 RPM ⅓ ⅓ ½ ⅓ ½ ½ ½ ¾ ¾ Speed 4 4 4 4 4 4 4 4 4 Vent Diameter ² 4" 4" 4" 4" 4" 4" 4" 4" 4" No. of Burners 2 3 3 4 4 4 5 6 6 Electrical Data Min. Circuit Ampacity ³ 8.1 8.1 12.5 8.1 12.5 12.5 12.5 14.7 14.7 Max. Overcurrent Device (amps) ⁴ 15 15 15 15 15 15 15 15 15 Ship Weight (lbs) 86 90 98 106 107 114 118 132 132 ¹ DOE AFUE based upon Isolated Combustion System (ICS) ² Vent and combustion air diameters may vary depending upon vent length. Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in Canada). ³ Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ⁴ Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted. Notes All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. Gas Service Connection ½ FPT Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. SS- www.goodmanmfg.com 3

Product Specifications 0403A*B 0603A*B 0804B*B 1005C*B Heating Capacity Input 40,000 60,000 80,000 100,000 Natural Gas Output 32,000 48,000 64,000 80,000 LP Gas Output 32,000 48,000 64,000 80,000 AFUE ¹ 80 80 80 80 Available AC @ 0.5 ESP 25-55 30-60 35-65 40-70 Temperature Rise Range ( F) 3 3 4 5 Circulator Blower Size (D x W) 10 X 6 10 X 6 10 X 8 10 X 10 Horsepower @1075 RPM 1/3 1/3 1/2 3/4 Speed 4 4 4 4 Vent Diameter ² 4 4 4 4 No. of Burners 2 3 4 5 Electrical Data Min. Circuit Ampacity ³ 8.5 8.5 12.9 12.9 Max. Overcurrent Device (amps) ⁴ 15 15 15 15 Ship Weight (lbs) 88 92 106 114 ¹ DOE AFUE based upon Isolated Combustion System (ICS) ² Vent and combustion air diameters may vary depending upon vent length. Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in Canada). ³ Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ⁴ Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted. Notes All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. Gas Service Connection ½ FPT Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. 4 www.goodmanmfg.com SS-

Dimensions Alternate Gas Inlet 1¾ A B 17 16 27⅞ 33⅜ Alt. Gas Inlet High-Voltage Inlet 20 235 16 Alt. High Voltage Low-Voltage Inlet 13¼ Alt. Low Voltage 23¾ 28 Model A B Model A B 0403A*B 14 12½ 0805C*B 21 19½ 0603A*B 14 12½ 1005C*B 21 19½ 0604B*B 17½ 16 1205D*B 24½ 23 0803B*B 17½ 16 1405D*B 24½ 23 0804B*B 17½ 16 Notes Line voltage wiring and low-voltage wiring can enter through the right or left side of furnace. Conversion kits for high-altitude (4500+ ft) natural gas operation are available. Contact your Goodman distributor or dealer for details. Minimum Clearances to Combustible Materials Sides Rear Front¹ SW Vent² B Top 1 0 3 6 1 1 ¹ 24 clearance for serviceability recommended. ² Single Wall Vent (SW) to be used only as a connector. Refer to the latest editions of the National Fuel Gas Code NFPA 54/ ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in Canada). Note: approved for line contact in the horizontal position. SS- www.goodmanmfg.com 5

Dimensions 19 ⅝ 28 High-Voltage Electrical A B Low-Voltage Electrical Gas Inlet 33 ⅜ 18 ⅜ 11 ⅜ Model A B Non-Combustible Floor Base 0403A*B 14 12½ SBT14 0603A*B 14 12½ SBT14 0804B*B 17½ 16 SBT17 1005C*B 21 19½ SBT21 Notes Line voltage wiring and low-voltage wiring can enter through the right or left side of furnace. Conversion kits for high-altitude (4500+ ft) natural gas operation are available. Contact your Goodman distributor or dealer for details. Installer must supply the following gas line fittings, according to which entrance is used: Left: One 90º street elbow; one 2½ pipe nipple; one 90º elbow; straight pipe; one ground joint union Right: Straight pipe to reach gas valve Minimum Clearances to Combustible Materials Sides Rear Front¹ SW Vent² 1 0 3 6 1 1 ¹ 24 clearance for serviceability recommended. ² Single Wall Vent (SW) to be used only as a connector. Refer to the latest editions of the National Fuel Gas Code NFPA 54/ ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in Canada). B Top 6 www.goodmanmfg.com SS-

Airflow Data Model 0403A*B 0603A*B 0604B*B 0803B*B 0804B*B 0805C*B 1005C*B 1205D*B 1405D*C ¹ @ 0.5 ESP Motor Speed Tons AC¹ (CFM & Temperature Rise vs. External Static Pressure) External Static Pressure, (Inches Water Column) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM High 3 1,521 --- 1,466 --- 1,414 --- 1,373 --- 1,298 --- 1,243 1,164 1,075 Med 2.5 1,160 26 1,160 26 1,132 26 1,121 26 1,082 27 1,042 997 925 Med-Lo 2 961 31 955 31 948 31 932 32 913 33 882 821 803 Low 1.5 781 38 785 38 781 38 773 38 761 32 745 716 668 High 3 1,422 31 1,352 33 1,307 34 1,197 37 1,157 38 1,092 1,075 983 Med 2.5 1,098 40 1,081 41 1,051 42 1,039 43 1,021 44 983 924 868 Med-Lo 2 919 48 913 49 892 50 847 ---- 829 ---- 818 792 728 Low 1.5 758 ---- 741 ---- 741 ---- 733 ---- 699 ---- 677 649 626 High 4 2,134 21 2,100 21 2,042 22 1,975 23 1,883 24 1,786 1,700 1,601 Med 3.5 1,668 27 1,663 27 1,656 27 1,645 27 1,616 28 1,549 1,492 1,391 Med-Lo 3 1,419 31 1,426 31 1,426 31 1,432 31 1,419 31 1,378 1,328 1,261 Low 2.5 1,134 39 1,145 39 1,166 38 1,171 38 1,160 38 1,144 1,111 1,071 High 3 1,607 37 1,572 38 1,547 39 1,498 40 1,448 41 1,390 1,302 1,222 Med 2.5 1,159 51 1,156 51 1,145 52 1,127 53 1,108 53 1,075 1,033 957 Med-Lo 2 938 63 916 65 916 65 900 ---- 889 ---- 865 829 785 Low 1.5 785 ---- 766 ---- 743 ---- 730 ---- 709 ---- 683 666 604 High 4 2,051 ---- 1,983 ---- 1,895 --- 1,812 --- 1,725 --- 1,627 1,530 1,439 Med 3.5 1,736 --- 1,708 35 1,652 36 1,611 37 1,540 38 1,475 1,394 1,307 Med-Lo 3 1,493 35 1,668 36 1,459 41 1,429 41 1,389 43 1,339 1,274 1,204 Low 2.5 1,200 49 1,185 50 1,180 50 1,173 51 1,158 51 1,125 1,125 1,080 High 5 2,290 ---- 2,229 ---- 2,155 ---- 2,047 ---- 1,960 ---- 1,837 1,712 1,584 Med 4 1,852 --- 1,820 --- 1,777 --- 1,719 --- 1,641 36 1,567 1,469 1,382 Med-Lo 3.5 1,615 37 1,592 37 1,556 38 1,516 39 1,470 40 1,405 1,346 1,235 Low 3 1,290 46 1,285 46 1,265 47 1,235 48 1,214 49 1,174 1,044 904 High 5 2,323 --- 2,225 --- 2,120 35 2,040 36 1,974 38 1,801 1,688 1,577 Med 4 1,858 40 1,847 40 1,799 41 1,744 42 1,674 44 1,577 1,493 1,399 Med-Lo 3.5 1,596 46 1,587 47 1,571 47 1,552 48 1,493 50 1,397 1,326 1,217 Low 3 1,291 57 1,272 58 1,261 59 1,257 59 1,205 61 1,168 1,118 1,060 High 5 2,469 --- 2,389 --- 2,300 --- 2,223 40 2,131 42 2,027 1,902 1,786 Med 4 1,575 56 1,558 57 1,545 58 1,513 59 1,500 59 1,419 1,354 1,271 Med-Lo 3.5 1,402 63 1,380 64 1,343 66 1,319 67 1,296 69 1,245 1,183 1,106 Low 3 1,200 ---- 1,186 ---- 1,161 ---- 1,127 ---- 1,082 ---- 1,042 995 926 High 5 2,469 42 2,389 43 2,300 45 2,223 47 2,131 49 2,027 1,902 1,786 Med 4 1,575 66 1,558 67 1,545 67 1,513 69 1,500 69 1,419 1,354 1,271 Med-Lo 3.5 1,402 ---- 1,380 ---- 1,343 ---- 1,319 ---- 1,296 ---- 1,245 1,183 1,106 Low 3 1,200 ---- 1,186 ---- 1,161 ---- 1,127 ---- 1,082 ---- 1,042 995 926 Notes CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters, this chart assumes both filters are installed. All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling and heating speed as needed. For most jobs, 400 CFM per ton for cooling is desirable. INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. This chart is for information only. For satisfactory operation, external static pressure should not exceed value shown on the rating plate. The dashed (----) areas indicate a temperature rise not recommended for this model. At higher altitudes, a properly derated unit will have approximately the same temperature rise at a particular CFM, while ESP at the CFM will be lower. SS- www.goodmanmfg.com 7

Airflow Data Model 0403A*B (Med)² 0603A*B (Med)² 0804B*B (Med)² 1005C*B (Med)² Motor Speed ¹ Heating speed as shipped ² @ 0.5 ESP Tons AC¹ (CFM & Temperature Rise vs. External Static Pressure) External Static Pressure, (Inches Water Column) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM High 3.0 1,353 --- 1,290 --- 1,246 --- 1,199 25 1,149 26 1,116 1,116 1,099 Med 2.5 1,183 25 1,113 27 1,098 27 1,052 28 1,039 29 1,006 1,012 969 Med-Lo 2.0 980 30 946 31 920 32 900 33 896 33 885 855 804 Low 1.5 778 38 762 39 738 40 746 40 738 40 717 696 678 High 3.0 1,290 34 1,236 36 1,194 37 1,166 38 1,176 38 1,166 1,108 1,029 Med 2.5 1,139 39 1,090 41 1,035 43 1,063 42 1,063 42 1020 962 895 Med-Lo 2.0 962 46 927 48 925 48 941 47 909 49 877 834 779 Low 1.5 787 56 776 57 763 58 744 60 723 --- 690 641 581 High 4.0 2,128 --- 2,063 --- 2,001 --- 1,927 --- 1,824 --- 1,726 1,628 1,529 Med 3.5 1,840 --- 1,788 --- 1,745 --- 1,689 35 1,625 36 1,550 1,470 1,364 Med-Lo 3.0 1,602 37 1,558 38 1,543 38 1,493 40 1,455 41 1,402 1,328 1,239 Low 2.5 1,277 46 1,252 47 1,244 48 1,229 48 1,214 49 1,179 1141 1079 High 5.0 2,405 --- 2,361 --- 2,250 --- 2,161 --- 2,037 36 1,937 1,808 1,689 Med 4.0 1,880 39 1,838 40 1,794 41 1,734 43 1,677 44 1,568 1,510 1,401 Med-Lo 3.5 1659 45 1,630 45 1,587 47 1,537 48 1,492 50 1,445 1,368 1,287 Low 3.0 1,472 50 1,454 51 1,404 53 1,366 54 1,326 56 1300 1228 1139 Notes CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters, this chart assumes both filters are installed. All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling and heating speed as needed. For most jobs, 400 CFM per ton for cooling is desirable. INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. This chart is for information only. For satisfactory operation, external static pressure should not exceed value shown on the rating plate. The dashed (----) areas indicate a temperature rise not recommended for this model. At higher altitudes, a properly derated unit will have approximately the same temperature rise at a particular CFM, while ESP at the CFM will be lower. 8 www.goodmanmfg.com SS-

Temperature Rise Range Chart 100 90 80 70 60 50 40 30 20 10 BTU BTU/h OUTPUT Output vs TEMPERATURE Vs. Temperature RISE Rise Chart CHART 600 CFM 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM Formulas FORMULAS BTU OUTPUT = CFM 1.08 x RISE BTU/h Output = CFRM x 1.08 x Rise BTU OUTPUT RISE = BTU/H Output CFM Rise = 1.08 CFM CFM x 1.08 30 40 50 60 70 80 90 100 110 120 130 140 150 OUTPUT Output BTU/h BTU/HR x 1,000 x 1000 TEMPERATURE Temperature Rise RISE SS- www.goodmanmfg.com 9

Wiring Diagram WARNING:DISCONNECT POWER BEFORE SERVICING.WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. XFMR (6) HUMIDIFIER GND INTEGRATED CONTROL MODULE PU YL 0 1 2 3 4 5 6 7 8 C RD YL RD PU BK HOT SURFACE IGNITER GR PU 0140F00662 REV. A BK STEADY ON = NORMAL OPERATION OFF PU 1 FLASH = = CONTROL FAILURE 24V 115V XFMR PRIMARY LIMIT BR RD ROLLOUT LIMITS (SINGLE CONTROL ON SOME MODELS) RAPID FLASHES = REVERSED 115 VAC POLARITY/VERIFY GND FLAME SENSOR SYSTEM LOCKOUT (RETRIES/RECYCLES EXCEEDED) 2 FLASHES = PRESSURE SWITCH STUCK CLOSED 3 FLASHES = PRESSURE SWITCH STUCK OPEN 4 FLASHES = OPEN HIGH LIMIT 5 FLASHES = FLAME SENSE WITHOUT GAS VALVE 6 FLASHES = OPEN ROLLOUT OR OPEN FUSE 7 FLASHES = LOW FLAME SIGNAL COLOR CODES: YL YELLOW OR ORANGE PU PURPLE GR GREEN BK BLACK 24 VAC HUMIDIFIER 10 11 7 8 9 LINE NEUTRAL C G R W Y 12 6 5 4 FUSE 3 2 1 2 1 PK PINK BR BROWN ITE BL BLUE GY GRAY RD RED DOOR SWITCH SWITCH LOCATED IN BLOWER COMPARTMENT ON SOME MODELS RD AUTO 1 STG 150 SEC XFMR-H LINE-H RD SEE NOTE 6 INTEGRATED CONTROL MODULE PM 1 C FS EAC-H 2 STAGE GAS VALVE (HONEY WELL) HI 2 3 PU 5 MIN 2 STG 100 SEC 2ND STG DLY MODE HT OFF DLY BL DIAGNOSTIC LED LO HEAT-H PARK 8 FLASHES = CHECK IGNITER OR IMPROPER GROUND RD BK YL BL OR YL BR BL HI HEAT-H COOL-H BK OR BL BR CICULATOR BLOWER AUXILIARY LIMITS BR BL (MED) OR(MED LOW) RD (LOW) (N) CAP 15 PIN PLUG ON SOME MODELS INDUCED DRAFT BK (HI) BR BR BLOWER COMPARTMENT BURNER COMPARTMENT YL BK NO BLOWER 24 VAC HUMIDIFIER C PRESSURE SWITCH BK 24V THERMOSTAT CONNECTIONS INTEGRATED CONTROL MODULE C G Y W R TO MICRO XFMR (3) XFMR-H FP LINE-H DOOR SWITCH INTERNAL TO INTEGRATED CONTROL IGN IND GND (8) MVC (9) MVH (12) MVL (2) PS (10) PSO (4) HLI (7) HLO (1) RO2 (11) RO1 (5) COOL-H HI HEAT-H WARNING: DISCONNECT POWER BEFORE SERVICING. WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. L JUNCTION BOX LOW VOLTAGE (24V) LOW VOLTAGE FIELD HI VOLTAGE (115V) HI VOLTAGE FIELD JUNCTION TERMINAL PLUG CONNECTION AUXILIARY LIMIT CONTROLS 115 VAC FLAME SENSOR HOT SURFACE IGNITER ID BLWR CIRCULATOR BLWR C C2 HI M1 GAS VALVE ID BLOWER PRESSURE SWITCH NO MANUAL RESET ROLLOUT LIMIT CONTROL(S) (SINGLE CONTROL ON SOME MODELS) 24 VAC 40 VA TRANSFORMER JUNCTION BOX NOTES: 1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS. 2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED EN SERVICING. 3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105 C. USE COPPER CONDUCTORS ONLY. 4. BLOWER SPEEDS SHOULD BE ADJUSTED BY INSTALLER TO MATCH THE INSTALLATION REQUIREMENTS SO AS TO PROVIDE THE CORRECT HEATING TEMPERATURE RISE AND THE CORRECT COOLING CFM. (SEE SPEC SHEET FOR AIR FLOW CHART) 5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES. 6. TO RECALL THE LAST 5 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS ILE IN STANDBY(NO THERMOSTAT INPUTS). YL EAC-H GND CIR-N XFMR-N LINE-N OVERCURRENT PROTECTION DEVICE LINE-N GND LINE H LO HEAT-H TO 115 VAC/ 1/60HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE ELECTRONIC AIR CLEANER N IGN-N IND-N EAC-N FIELD SPLICE SWITCH (TEMP.) SWITCH (PRESS.) AUTO RESET PRIMARY LIMIT CONTROL DISCONNECT EQUIPMENT GND FIELD GND IGNITER OVERCURRENT PROT. DEVICE INTEGRATED CONTROL MODULE High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. 10 www.goodmanmfg.com SS-

Accessories Model Description 0403A* 0603A* 0604B* 0803B* 0804B* 0805C* 1005C* 1205D* 1405D* LPM-06 LP Conversion Kit (Springs & Orifice)¹ HANG20 High-Altitude Natural Gas Kit (4500+ ft) FTK04 Twinning Kit MVK-01² Masonry Vent Kits MVK-02² Masonry Vent Kits AFE18-60A Fossil Fuel Kit ¹ Honeywell or White-Rodgers valves ² Upflow applications only Model Description 0403* 0603* 0804* LPM-06 LP Conversion Kit (Springs & Orifice)¹ HANG20 High-Altitude Natural Gas Kit (4500+ ft) FTK04 Twinning Kit AFE18-60A Fossil Fuel Kit SBT 14/17/21* Downflow Sub-base ¹ Honeywell or White-Rodgers valves 1005* Minimum Filter Sizes Model # Filter Size (in²) 0403A* 0603A* (1) 16 x 25 (Side) or (1) 14 x 24 (Bottom) 0604B* 0803B* 0804B* (1) 16 x 25 (Side or Bottom) 0805C* (1) 16 x 25 (Side or Bottom) ¹ 1005C* (2) 16 x 25 (Side) or (1) 20 x 25 (Bottom) Note: Other size filters of equal or greater surface area may be used; filters may also be centrally located. ¹ Use 2-16 x 25 filters on side returns or 20 x 25 filter on bottom return if furnace is connected to a cooling unit over 4 tons nominal capacity. 1205D* 1405D* (2) 16 x 25 (Side) or (1) 24 X 24 (Bottom) Minimum Filter Sizes Model # 0403A* 0603A* 0804B* 1005C* Filter Size (in²) (2) 10 x 20 or (1) 14 x 25 Top Return (2) 14 x 20 or (1) 16 x 25 Top Return Note: Other size filters of equal or greater surface area may be used; filters may also be centrally located. (2) 14 x 20 or (1) 20 x 25 Top Return SS- www.goodmanmfg.com 11

Notes Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. 2015 Goodman Manufacturing Company, L.P. Houston, Texas Printed in the USA. 12 www.goodmanmfg.com SS-