www. ElectricalPartManuals. com Type AM Magne-Biast Circuit Breakers RENEWAL PARTS

Similar documents
www. ElectricalPartManuals. com Type AM ,-6 Magne-Biast Circuit Breakers RENEWAL PARTS GENERAL. ELECTRIC GEF-4438A Supersedes GEF-4438

RENEWAL PARTS I C302AA A-2 300V AB A-4800V A C A -SOOOV PARTS RECOMMENDED FOR NORMAL STOCK

RENEWAL PARTS AK-2-15 AK-2-25 AK-3-25 AKF-2-25 AK-2A-15 AK-2A-25 AK-3A-25 AKF-2A-25 AKU-2-25 AKU-3-25 AKU-2A-25 AKU-3A-25

CD5--- CA4--- CD6---- CB2---- CB4---- PARTS RECOMMENDED FOR NORMAL STOCK

Frame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50

www. ElectricalPartManuals. com GENERAL. ELECTRIC RENEWAL PARTS METAL-CLAD SWITCHGEAR TYPES M-26 AND M-36 GEF-4351C Supersedes GEF-4351B

GEF-4647A. GE Drive Systems. Renewal Parts. HEAVY DUTY DC CONTACTORS DS303Al (600V STYLE) DS303Bl (looov STYLE) www. ElectricalPartManuals.

BBC. Renewal Parts. I-T-E Low-Voltage Power Circuit Breakers

CR193 B,C,D and E Vacuum Limitamp * Contactors

GEF Renewal Pans. low Vohage Power Circuit Breakers. Type AKR-30S and AKRU-30S. www. ElectricalPartManuals. com

DEF 005. WavePro Power Circuit Breakers A Frames, Vac. Renewal Parts

GENERAL. ELECTRIC RENEWAL PARTS IC302E HIGH VOLTAGE CONTACTORS. EA A-2300V IEl A-4800V l:c a-sooov

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

www. ElectricalPartManuals. com POWER CIRCUIT BREAKERS TYPES AK-2/3/2A/3A-50, AKU-2/3/2A/3A-50, AKT-2/3/2A/3A-50 GENERAL fj ELECTRIC

www. ElectricalPartManuals. com GENERAL. ELECTRIC RENEWAL PARTS CR7006-C100, -C101 AND -C102 MAGNETIC STARTERS

FOR PRICES ON DSII and DSLII BREAKERS, REFER TO PRICE LIST PL.22B.01.P.E

Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035

PoweMr' With 18 Mechanism '. 1 . / ,, ( c :11t

www. ElectricalPartManuals. com BBC Brown Boveri Electric Renewal Parts 1-T -E Low-Voltage Power Circuit Breakers

WLI Medium Voltage Switchgear Renewal Parts

920 Remote Control Switches

Evolution * Series E9000 Motor Control Center

A-Series II Panelboards AD/AE/AQ Type P & N Power Panel SE/TED Three-Phase Circuit Breaker Kits

www. ElectricalPartManuals. com Cutler-Hammer Power Breaker Center Renewal Parts for Low Voltage Power Circuit Breakers Types DB, DBL and DBF

www. ElectricalPartManuals. com It'll Cutler-Hammer WLI Medium Voltage Switchgear Renewal Parts Renewal Parts Data Page 1

www. ElectricalPartManuals. com

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components

www. ElectricalPartManuals. com

A-Series II Panelboards AD/AE/AQ Type P & N Panel THQB Three-Phase Circuit Breaker Kits

Westinghouse Molded Case Circuit Breakers Engine Generator FG Amperes

Motor Control. Motor Control Electrical Aftermarket Products and Services Contents

FULL VOLTAGE STARTERS z SIZE 8 SERIES B CONSTRUCTION

Parts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4)

D300K 3+3 KUBOTA PARTS LIST FOR RETURN TO MAIN INDEX

POWER TERMINAL BLOCKS

DEH Installation

Typical AEP Panelboard

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Arktite Circuit Breaking CPS Receptacles and CPP Plugs Delayed Action Factory Sealed

5H KA, RMS C/L Recommendations for Stock POLE UNIT PARTS ARC CHUTE DETAILS. Core, Fig. 17, It.

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

INSTRUCTIONS. GE Protection and Control. 205 Great Valley Parkway Malvern, PA UNDERVOL TAGE RELAYS TYPES: IAV54E IAV55C IAV54F IAV55F

DEF-002. Vacuum Limitamp Medium Voltage Motor Control. wal Parts

Parts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4)

Parts List, Wiring Diagrams

Instructions for Replacing

www. ElectricalPartManuals. com MAGNETIC TIME RELAYS GENERAL. ELECTRIC INSTRUCTIONS *IC *Also identified with prefix CR instead of IC.

GENERAL ELECTRIC MAGNE-BLAST CIRCUIT BREAKER INSTRUCTIONS AND RECOMMENDED PARTS MAINTENANCE TYPE

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Product Selection 3-Pole Contactors

VOYTEN ELECTRIC & ELECTRONICS

contactor may be required to interrupt up to 200% current. The N.O. contacts are equipped with permanent magnet blowouts to meet this requirement.

Design Guide for Integration of Fixed-Mount Circuit Breakers

Industrial Control Transformers

~

Cutler-Hammer I.L. 29C160G WARNING NOTICE 1-0 INTRODUCTION. General Information

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

mi Model 108 Compact Tractor Parts Catalog

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

"'.. "" "'" Table of troubles and their causes. I Running irregula,- ( Probable cause. "-. I I i Piston rings got stuck I. Engin.

Brushcutter. Model No A & Up. Parts Catalog

Installation Instructions for KPS and KPH Circuit Breakers and Molded Case Switches

TC-200 TRANSFER CASE PARTS MANUAL

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Panelboard Renewal Parts Supplement

Typical AE Panelboard

CIRCUIT BREAKERS. Explosionproof Circuit Breaker Enclosures EXPLOSIONPROOF MOTOR CONTROL EXPLOSIONPRROOF MOTOR CONTROL BREAKERS ENCLOSURES

Typical AD Panelboard

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003

www. ElectricalPartManuals. com Instructions for Load Break Air Switch, Type LBF, for Power Centers

Crane Control. Crane Control 1. Contents. Description Heavy-Duty Brakes Shoe Brakes Magnetically Operated Master and Limit Switch Family

Type SJK Test Switches

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)

T CLASS T FUSE BLOCKS

GEK41931B INSTRUCTIONS MULTI-CONTACT AUXILIARY RELAYS TYPE HFA73K. GE Protection and Control 205 Great Valley Parkway Malvern, PA

CATALOG OF REPLACEMENT PARTS W32/W32C/625A WRAP STATION ML-44103, ML ML-44105, ML ML-26243

Air Circuit Breaker Manual English Electric

COMPRESSORS 09/97 CB-5C-050. Suggested Spare Parts for LB601 and LB601A Compressors: Qty./ Unit

Form No CE Parts List for:

Typical ADP Panelboard

Medium Voltage Metal-Enclosed Switches

Type SOQ Negative Sequence Time Overcurrent Relay

PARTS CATALOG MODEL FBD352 DISPENSER

A. Submit manufacturer's literature and technical data before starting work.

COMMERCIAL QUICK REFERENCE

ONAN ELECTRIC GENERATING PLANTS

Enclosed Molded Case Circuit Breakers

Super Blue Ribbon V-Belt

LBI-30246F INSTRUCTIONS FOR FUSE PANELS 19C327027G1, G2, G4, G5, G8, G9, G10, G11, G14 & G15 AND FILTER PANEL 19D423732G1 DESCRIPTION

LB601B PARTS LIST COMPRESSORS CB-5E /06. Bulletins Needed For Complete Parts List. Gasket Set, Repair Kits and Special Tools

CR193 Vacuum Limitamp* Contactors

Instructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers

GEF~4630A. Limitamp Medium-Voltage Motor Control. CR7160 Renewal Parts Bulletin

ERD/ERC SERIES ELECTRIC FRYERS

Washer-Extractor Pocket Hardmount

Multi-Pak Group Control

MM184 Rev. 12 (9 94)

RENEWAL PARTS ORDER GUIDE. FCV-500 AND FCV-750 VACUUM CIRCUIT BREAKERS WITH STORED ENERGY OPERATOR NO V

www. ElectricalPartManuals. com INSTRUCTION BOOK h'o. AIR CIRCUIT BREAKER Types 50-DB-ISOE and 50-DB-2501 j,," ,,,,< W_,;wkiiii i!t;s..;._.:...:..,fk.

Transcription:

RENEWAL PARTS Ordering Instructions 1. Always specify the complete nameplate data of the breaker. 2. Specify the quantity, catalog number (if listed), reference number (if listed) description, and this bulletin number. 3. Standard hardware, such as screws, bolts, nuts, washers, etc., is not listed in this bulletin. Such items should be purchased locally. 4. For prices, refer to the nearest office of the General Electric Company. Data is subject to change without notice. GEF-4426A Supersedes GEF-4426 Type AM-4.16-250 Magne-Biast Circuit Breakers Note: The ML-13 operating mechanism is not included in this publication. Refer to GEF-4379.

GEF-4426 2 19A - --- -- --- 3 B. Barrier support 27 28 TYPE AM-4.16 MAGNE-BLAST CIRCUIT BREAKERS 31 31 (1200amp) (2000amp) 150 1 100 32 30 29 C. Hinge assembly (See Section A A) Fig. 1. 19 6 4 A. Breaker, TypeAM-4.16-4 42 Cross section views D. Cylinder support 36 ' 38 '>--- 43

TYPE AM-4.16 MAGNE-BLAST CIRCUIT BREAKERS Type AM-4. 16-250 Magne-blast Circuit Breaker (Refer to Fig. 1) Ref. Ampere Catalog Number for AM-4. 16 No. No. Rating -6H and -6C -7H and -7C -8H and -8C Reqd. Description GEF-4426 1 All 733-0619C0444G005 733-0619C0444G005 733-0619C0444G005 3 Booster cylinder 2 All 0114C5388G001 0114C5388G001 0114C5388G001 1 Box barrier assembly 3 All * * * * Box barrier guide 4 All 0137A6025G001 3 Arc chute support assembly 5 All 0258C0619P008 3 Connection bar 6 All 0619C0444G003 -- -- 3 Arc chute clamp 7 All 0137A6001P001 -- -- 3 Arc chute support, left 7 All 0137 A6001P002 3 Arc chute support, right 8 All 0619C0461G005 0619C0461G012 0619C0461G012 1 Vertical barrier, left 8 All 0619C0461G002 0619C0461G011 0619C0461G011 1 Vertical barrier, center 8 All 0619C0461G010 0619C0461G010 0619C0461G010 1 Vertical barrier, right 9 All 0281B0708G002 0281B0708G002 0281B0708G002 3 Operating rod 10 1200 0258C0614P006 0258C0614P006 0258C0614P006 6 Horizontal barrier, upper 10 2000 0258C0614P007 0258C0614P007 0258C0614P007 6 Horizontal barrier, upper 11 1200 0845D0123G001 0845D0123G001 0845D0123G001 3 Bushing, long 11 2000 0688C0515G001 0688C0515G001 0688C0515G001 3 Bushing, long 12 All 0619C0461P026 0619C0461P026 0619C0461P026 3 Block 13 1200 0688C0575P011 0114C 5380P011 0114C5380P011 6 Horizontal barrier, lower 13 2000 0688C0575P012 0114C5380P012 0114C 5380P012 6 Horizontal barrier, lower 14 1200 0688C0575P009 6 15 1200 0258C0614P020 0258C0614P020 0258C0614P020 4 Cover plate 16 2000 0619C0444P029 0619C0444P029 0619C0444P029 1 Top plate All 0635D0390G001 0635D0390G001 0635D0390G001 1 Wheel assembly, complete 18 0236C0767G007 0236C0767G007 0236C0767G007 1 Wheel assembly, complete 19 All 006597296P008 006597296P008 006597296P008 2 Wheel and spanner bushing 19A 006597296P006 006597296P006 006597296P006 2 Wheel and spanner bushing 20 1200 0898B0282G001 0898B0282G001 0898B0282G001 3 Hinge point assembly 21 2000 0898B0282G002 0898B0282G002 0898B0282G002 3 Hinge point assembly 22 2000 006442246P001 006442246P001 006442246P001 6 23 2000 006441630P001 006441630P001 006441630P001 3 Washer 24 2000 006442257P001 006442257P001 006442257P001 3 Bearing 25 2000 0369A0407P001 0369A0407P001 0369A0407P001 3 Spring 26 2000 0414A0106P007 0414A0106P007 0414A0106P007 3 Bolt 27 All 006444617P001 006441617P001 006441617P001 3 Washer 28 1200 0414A0106P004 0414A0106P004 0414A0106P004 3 Screw 29 1200 0421A0239P001 0421A0239P001 0421A0239P001 3 Spring 30 1200 0137 A9186P001 0137 A9186P001 0137 A9186P001 3 Bearing 31 All 0456A0884P001 0456A0884P001 0456A0884P001 6 Hinge washer 32 All 0456A0862P009 0456A0862P009 0456A0862P009 2 Front wheel and caster t33 All 0105C9317G1 0105C9317G001 0105C9317G001 1 Mechanism cover 34 All 0619C0461P025 0619C0461P025 0619C0461P025 3 Plate 35 All 006176110P441 6, 3 3/4 inch 36 All 0619C0444P006 0619C0444P006 0619C0444P006 3 Support t37 All 0137 A9103P001 3 Booster cylinder jumper 38 All,li0688C0575P001 0114C5380P003 0114C5380P003 6 Support All,li0688C0575P002 0114C5380P001 0114C5490P001 3 Support, left 40 All tcl688c0575p003 0114C5380P002 0114C5490P002 3 Support, right 41 All tcl688c0575p004 0114C5380P004 0114C5490P003 3 Connection bar 17 39 42 All tcl619c0444g004 0619C0444G003 0619C0444G003 3 Arc chute clamp 43 All t<:j421a0209p429 0421A0209P429 0421A0209P429 3 44 All t<:j421a0209p447 0421A0209P447 0421A0209P447 3 t Not illustrated. For breaker model list with W suffix. /.For Type -6H and -6C only. Order Ref. No. 38 through 44 when individual parts are required. If the complete assembly is required order Ref. No. 4 which includes parts 38 through 44. *{For box barrier with fabricated top, order quantity of (2) Cat. No. 0258C0614P037. For box barrier with molded top, order quantity of (2) Cat. No. 0114C5381P006. 3

GE F-4426 102 144 104 135 101 137 137A 106 11 3 109 11 0 112 TYPE AM-4.16 MAGNE-BLAST CIRCUIT BREAKERS ==== --102 -- 104 ---135 --- 144 129 ::::i:::::=t::::=::=;,-j- I 03 A. Complete arc chute assembly "-6" design ) 145 ---.. 136---!!"''!!11 122-- "'!!!.. 11 8 --.III 120--!1!11 107---!!- 108--.. 123 - --!: 121 127 --- 128 119 130 - ;;;;:;;;:,.i._ -- 124 136,...--- 122 102 11 8 120 107 108 121 123 12 7 128 11 130 9 126 108-138 i:l:i.---107 ---132 142 12 i!it== 13 9 11 --- 131 --- 133 143 B. Side cover removed "-6" design 139 -:;..._, 140 126---11111! 148 ---!!!!11 132 -==< - 138-108 ---""1111 142 125 --'11 10 7 --""'" 147 ---!!!! 131-- 133 103 143 4 134 ',.../ C. Complete arc chute assembly "-7" and "-8 " D. Side cover removed "-7" and "-8" design design Fig. 2. Arc chute

104-- 105., J.. 137 137A 112 --- Ref. No. 100 101 102 103 104 105 106 107 107 108 108 109 110 111 111 112 113 114 115 115 116 117 118 119 119 119 120 121 122 123 124 125 E. Front view TYPE AM-4.16 MAGNE-BLAST CIRCUIT BREAKERS 115 13 6 135 118 12 1 106 132 110 138 125 131 129 129 134 115 139 140 13 3 Ill 103 117 116 F. Bottom view Fig. 2. Arc chute (cont'd.) Arc Chute Assembly (Refer to Fig. 2) Catalog Number for Type AM-4. 16 No. -6H and -6C -7H and -7C -8H and -8C Reqd. 733-021500469G002 733-0213X0416G001 733-0213X0416G010 3 0456A0381P002 0456A0381 P003 0456A0381P003 6 0264B0100G003 0264B0100G003 0264B0100G003 3 0258C0616P004 0258C 0616 P004 0258C0616P004 6 0215D0469G050 0215DX0416G004 0213X0416G016 3 0421A0208P078 006176109P072 006176109P078 6 0258C0615G002 0836C0197G004 0836C0197G004 3 0258C0615P029 0258C0615P019 0258C0615P031 3 0258C0615P019 0258C0615P030 0258C0615P030 3 0258C0616P018 0258C0616P023 0258C0615P025 3 0258C0616P023 0258C0616P024 0258C0616P024 3 0107B9365P001 0114C5381P002 0114C 5381 P002 6 0258C0615G006 0836C0197G002 0836C0197G002 3 0421A0208P093 24 0421A0208P093 0421A0208P093 12 0258C0615G003 0836C0197G001 0836C0197G001 3 0258C0615G001 0836C0197G003 0836C0197G003 3 0258C0615P011 0258C0615P011 0258C0615P011 3 0421A0209P082 3 0456A0888P005 0456A0888P005 9 000432249P001 000432249P001 00432249P001 6 006176109P072 006176109P072 006176109P072 6 0414A0116P002 0114C 5381P003 0414A0116P002 3 0414AO 117 POO 1 6 0108B1965G001 0195A7377G001 3 0108B1965G002 0195A7377G002 3 0366A0743G001 0366A0743G001 0366A0743G001 3 0258C0632G001 0962C0745G001 0962C0745G001 3 o421a0208p024 0421A0208P024 0421A0208P024 12 0456A0891P210 0456A0891P210 0456A0891P210 3 0258C0616P005. 0258C0616P005 0258C0616P005 3 0258C0616P011 0258C0616P011 0258C0616P011 3 GEF-4426 13 0 -- 138 ---132.,. 139 140 G. Lower runner assembly "-6" design Description Arc chute assembly Brace Arc chute sides Lower support Upper support Upper pole piece, right Core, upper Core, lower Core insulation, upper Core insulation, lower Shield Lower pole piece, right Lower pole piece, left Upper pole piece, left Connection Insulation plate Throat insulation Throat insulation, right Throat insulation, left Coil, upper Runner assembly, upper Insulation strip 125 143 131 134 133 5

GEF-4426 A. Front view (for 1200 amp breakerj 153 170 171 155 171 156 TYPE AM-4.16 MAGNE-BLAST CIRCUIT BREAKERS 164 166 152 -- 15 8..., 169 16 0 163 161 165--..., 168--- 15 9--- o_;;;;--- 15 6!---158 B. Side view (for 1200 amp breaker) 158 (-8H) 170 I 55 A E. Side view (for F. Rear view (for 2000 amp breaker) 2000 amp breaker) 6 153 15 4 155 169 156 158 155A C. Rear view (for 1200 amp breaker) 153 I 152 Fig. 3. Rear bushing assembly (Ref. No. 150) 151 166 160 161 165 D. Front view (for 2000 amp breaker) 154 165 156 169 158 I = ill ' 1! J ;ui I I 164 168 160 161 155 155A 159 G. Component parts (1200 amp rear bushing),

TYPE AM-4.16 MAGNE-BLAST CIRCUIT BREAKERS Arc Chute Assembly (Refer to Fig. 2) (Cont'd) Ref. Catalog Number for Type AM-4. 16 No. No. -6H and -6C -7H and -7C -8H and -8C Reqd. Description GEF-4426 126 733-0366A0744G001 733-0366A0744G001 733-0366A0744G001 3 Coil, lower 127 0414A0131P004 0958C0604P012 0958C0604P012 AR Shim 128 006445050P010 006445050P010 006445050P010 3 129 0258C0615P015 0258C0615P015 0258C0615P015 3 Support 130 0383A0932P001 0161A5906P001 0161A5906P001 6 Lower shield 131 0258C0615G005 0258C0615G005 0258C0615G005 3 Connection assembly 132 0258C0615G004 0836C0198G002 0836C0198G002 3 Runner assembly, lower 133 0258C0616P022 0958C0604P004 0958C0604P004 3 134 0258C0616P021 0958C0604P005 0958C0604P005 3 135 0258C0616P009 0836C0197P014 0836C0197P014 6 Upper insulation 136 0258C0632P010 0836C0197P013 0836C0197P013 6 Barrier 137 000421711P001 000421711P001 000421711P011 6 Insulating cap 137A 000407193POO 1 000407193P001 000407193P001 6 Washer for insulating cap (Ref. 137) 138 0258C0616P006 0114C5381P001 0114C5381P010 6 Lower barrier 139 0258C0616P007 0836C0197P012 0836C0197P012 3 Barrier, left 140 0258C0616P008 0836C0197P011 0836C0197P011 3 Barrier, right 142 0421A0208P010 0421A0208P010 0421A0208P010 6 143 0414A0198P001 0114C5381P005 0114C5381P005 3 Insulation 144 0137 A9163P002 0137 A9163P002 0137 A9163P002 6 Insulating bushing 145 0958C0604P002 0958<:::0604P002 3 Barrier 146 0836C0197P015 0836C0197P015 6 Cup washer 147 - --- 0958C0604P006 0958C 0604P006 3 Barrier 148 0456A8091P219 0456A8091P219 3 Insulation strip Rear Bushing Assembly (Refer to Fig. 3) Ref. Ampere Catalo Number for Type AM-4. 16 No. No. Rating -6H and -6C -7H and -7C -8H and -8C Reqd. Description 150 1200 733-0254D0754G020 733-0236C0790G107 733-0213X0344G003 3 Rear bushing assembly 150 2000 0254D0754G015 0236C0790G108 0213X0344G004 3 Rear bushing assembly 151 1200 0688C0581G003 0688C0581 G003 0845D0124G001 3 Rear bushing, short 151 2000 0688C0516G001 0688C0516G006 0688C0516G006 3 Rear bushing, short 152 1200 0828C0782P004 0962C0778P007 0962C0778P007 3 Spring retainer strip 152 2000 0828C0782P005 0962C0778P007 0962C0778P007 3 Spring retainer strip 153 1200 0236C0791P017 0619C0443P017 0619C0443P017 3 Arc chute support 153 2000 0236C0791P019 0619C0443P008 0619C0443P008 3 Arc chute support 154 All 0236C0791G003 0236C0791G003 0236C0791G003 3 Arcing contact support 155 All 0236C0791G001 0236C0791G001 0236C0791G001 3 Flexible connection, right 155A All 0236C0791G004 0236C0791G004 0236C0791 G004 3 Flexible connection, left 156 All 0236C0790G009 0236C0790G009 0236C0790G009 3 Arcing contact assembly 158 All 0414A116P004 0414A0116P004 3 Insulating plate 158A All 0195A7388G002 3 Barrier assembly 159 All 006445087P004 006445087P004 006445087P004 3 Buffer 160 1200 0121A5964P001 12 Spring 160 1200 0121A5964P001 0121A5964P001 18 Spring 160 2000 006509787P001 24 Spring 160 2000 0121A5964P001 0121A5964P001 18 Spring 161 1200 N312P2542B 12 Spring guide 161 2000 N312P2542B Spring guide 161 All N312P2542B N312P2542B 18 Spring guide 163 All 0175V0557P001 0175V0557P001 0175V0557P001 6 Locking plate 164 1200 0258C0666P009 3 Contact support 164 2000 0962C0778P011 0962C0778P011 3 Contact support 165 1200 0236C0791P008 12 Primary contact finger 165 2000 0236C079lP008 24 Primary contact finger 165 All 0114C5382P002 0114C5382P002 18 Primary contact finger 166 1200 0828C0782P013 0962C0778J?002 0962C0778P002 3 Primary contact finger retainer 166 2000 0828C0782P008 0962C0778P002 0962C0778P002 3 Primary contact finger retainer 167 1200 006176109P006 12 167 All 006176109P006 006176109P006 18 168 1200 006557243P001 006176109P002 006557243P002 6 Buffer clamp 168 2000 006557243P002 006176109P002 006557243P002 6 Buffer clamp 169 All 0265C0151P025 3 Spring baffle 170 2000 0258C0632P008 -- -- 3 Copper plate, left-hand 171 2000 0258C0632 P009 3 Copper plate, right-hand 24 7

GENERAL ELECTRIC COMPANY BREAKER PLANT OPERATION PHILADELPHIA, PA 19142 12-84 (500) GENERAL. ELECTRIC

Ref. No. Ampere Rating 210 1200 210 2000 211 All 212 1200 212 2000 213 1200 213 2000 213 All 214 All 215 2000 216 1200 216 2000 217 All 218 All 219 1200 219 2000 220 All 221 All 222 All t223 All t Not illustrated. TYPE AM-4.16 MAGNE-BLAST CIRCUIT BREAKERS A. 2000 amp B. 1200 amp Fig. 4. Movable tontact arm assembly (Ref. No. 210) Movable Contact Arm Assembly (Refer to Fig. 4) Catalog Number for Type AM-4. 16 No. -6H and -6C -7H and -7C -8H and -8C Reqd. 733-0213X0343G030 733-0213X0343G041 733-0213X0343G077 3 0213X0343G031 0213X0343G042 0213X0343G078 3 0802B0742G001 0802B0742G001 0227 A5306G004 3 0137 A9164P003 3 0137A9164P003 6 0137 A9164P004 3 0137 A9164P004 6 0114C5382P004 0114C 5382P004 6 0258C0666P007 0258C0666P007 0258C0666P007 6 0258C0666P006 0258C0666 P006 0258C0666P006 6 0213X0343G043 0213X0343G043 0213X0343G090 3 0213X0343G044 0213X0343G044 0213X0343G091 3 0421A0248P001 0421A0248P001 0421A0248P001 3 0456A0874P003 0456A0874P003 0456A0874P003 3 0456A0874P002 0456A0874P002 0456A0874P002 3 0456A0874P002 0456A0874P002 0456A0874P002 6 0258C0619P006 0258C0619P006 0258C0619P006 3 0414A0146P053 0414A0146P053 0414A0146P053 6 0414A0146P054 0414A0146P054 0414A0146P054 12 0456A0876P208 0456A0876P208 0456A0876P207 12 Description GEF-4426 Movable contact arm assembly Movable contact arm assembly Arcing tip Movable primary contact Movable primary contact Movable primary contact Movable primary contact Movable primary contact Contact arm Contact arm Tube and piston assembly Tube and piston assembly Piston ring Piston ring equalizer Shim Shim Orifice Grip nut Grip nut 8

TYPE AM-4.16 MAGNE-BLAST CIRCUIT BREAKERS PARTS RECOMMENDED FOR NORMAL MAINTENANCE GEF-4426 Catalog No. for Type AM-4.16 Fig. Ref. Ampere No. No. No. Rating -6H and -6C -7H and -7C -8H and -8C Req'd Description 1 9 ALL 733-0281B0708G002 733-0281B0708G002 733-0281B0708G002 3 Operating rod 2 118 ALL 0414A0116P002 0114C5381P003 0414A0116P002 3 Insulating plate 2 119 ALL 0414A0117P001 --- --- 6 Throat insulation 2 119 ALL 0108B1965G001 0195A7377G001 3 Throat insulation, right 2 119 ALL 0108B1965G002 0195A7377G002 3 Throat insulation, left 2 130 ALL 0383A0932P001 0161A5906P001 0161A5906P001 6 Lower shield 2 135 ALL 0258C0616P009 0836C0197P014 0836C0197P014 6 Upper insulation 2 137 ALL 000421711P001 000421711POO 1 000421711P001 6 Insulating cap 2 137A ALL 000407193P001 000407193P001 000407193 POO 1 6 Washer for insulating cap (Ref. 137} 2 138 ALL 0258C0616P006 0114C5381P001 0114C5381P010 6 Lower barrier 3 155 ALL 0236C0791G001 0236C0791G001 0236C0791G001 3 Flexible connection, right 3 155A ALL 0236C0791G004 0236C0791G004 0236C0791G004 3 Flexible connection, left 3 156 ALL 0236C0790G009 0236C0790G009 0236C0790G009 3 Arcing contact assembly 3 158 ALL 0414A0116P004 0414A0116P004 --- 3 Insulating plate 3 160 1200 0121A5964P001 --- --- 12 Primary contact finger spring 3 160 1200 --- 0121A5964P001 0121A5964P001 18 Primary contact finger spring 3 160 2000 006509787P001 --- 24 Primary contact finger spring 3 160 2000 --- 0121A5964P001 0121A5964P001 18 Primary contact finger spring 3 165 1200 0236C0791P008 --- --- 12 Primary contact finger 3 165 2000 0236C0791P008 --- 24 Primary contact finger 3 165 ALL --- 0114C5382P002 0114C5382P002 18 Primary contact finger 4 211 ALL 0802B0742G001 0802B0742G001 0108B5506G001 3 Arcing tip 4 212 1200 0137A9164P003 - -- --- 3 Movable primary contact 4 212 2000 0137A9164P003 --- --- 6 Movable primary contact 4 213 1200 0137 A9164P004 --- --- 3 Movable primary contact 4 213 2000 0137 A9164P004 --- --- 6 Movable primary contact 4 213 ALL --- 0114C5382P004 0114C5382P004 6 Movable primary contact 4 216 1200 0213X0343G043 0213X0343G043 j 0213X0343G090 3 Tube and piston assembly 4 216 2000 0213X0343G044 0213X0343G044 0213X0343G091 3 Tube and piston assembly --- --- --- --- 9