28W WORK LAMP Model: CTL28 Part No:

Similar documents
HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

SUBMERSIBLE PUMP. Model No: HIPPO 2 OPERATING & MAINTENANCE INSTRUCTIONS

PROFESSIONAL CORDLESS IMPACT SCREWDRIVER

SWING ARM MAGNIFYING LAMP MODEL NO: SAM170

BENCH GRINDER MODEL CBG6RZ OPERATING & MAINTENANCE INSTRUCTIONS

LEAD ACID BATTERY CHARGER

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: , LS1010

BENCH GRINDER MODEL CBG6RP OPERATING & MAINTENANCE INSTRUCTIONS 0101

HEAVY DUTY BATTERY BOOSTERS / CHARGERS. MODEL Nos. BC185N & BC205N OPERATING INSTRUCTIONS

AIR FILTER MODEL NO: AF1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO:

JUMPSTART MODEL NO: JS900/JS910 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & GC10/16

POND PUMP Model Nos:SPP3 & SPP6 0200

JUMP STARTER OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JSM350 PART NO: ORIGINAL INSTRUCTIONS LS1117-ISS 1

PROFESSIONAL CORDLESS IMPACT WRENCH

SUBMERSIBLE WATER PUMPS

Bore Hole Pump Model Nos: CBB75 CBB100 Part Nos:

SUBMERSIBLE WATER PUMP

CORDLESS COMPRESSOR WITH SPOTLIGHT + JUMP START

SUBMERSIBLE PUMP HSE RANGE

BATTERY/BOOSTER CHARGER. Model No: BC100N Part No: OPERATING & MAINTENANCE INSTRUCTIONS

HOT AIR GUN MODEL No. CHG 1500B Part No

CORDLESS IMPACT WRENCH

ORIGINAL INSTRUCTIONS

SUBMERSIBLE WATER PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. CSE400A. Part No iss 2

OPERATION & MAINTENANCE INSTRUCTIONS

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

OPERATING & MAINTENANCE INSTRUCTIONS

SUBMERSIBLE PUMP HSE RANGE

OPERATION & MAINTENANCE INSTRUCTIONS

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105

OPERATION & MAINTENANCE INSTRUCTIONS

CFT24 &CFT230 PART NOS:

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ,

SUBMERSIBLE WATER PUMP

OPERATION & MAINTENANCE INSTRUCTIONS

SUBMERSIBLE PUMPS HSE RANGE OPERATING & MAINTENANCE INSTRUCTIONS GC0514

OPERATION & MAINTENANCE INSTRUCTIONS

MODEL Nos: CVAC20SS CVAC25SS CVAC30SSR OPERATING & MAINTENANCE INSTRUCTIONS. Distributed by CLARKE International Ltd.

RECHARGEABLE SPOTLIGHT

RECHARGEABLE SPOTLIGHT

24V DC - 1/2 SQUARE DRIVE IMPACT WRENCH KIT

9 (230mm) ANGLE GRINDER Model No. CAG232

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

BATTERY BOOSTER/CHARGER MODEL NO: DIGICAR 600

1100W PORTABLE GENERATOR

24V DC - 1/2 SQUARE DRIVE IMPACT WRENCH KIT

BATTERY STARTER/CHARGER MODEL NO: BC125, BC190

BATTERY BOOSTER/CHARGER MODEL NO: DIGICAR 900

HEAVY DUTY BATTERY BOOSTERS / CHARGER MODEL No. BC420N

JUMPSTART MODEL NO: JS1000, JS1010 & JS1224 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: , & GC0514

SPOT WELDER. Models CSW11 & CSW11T OPERATING & MAINTENANCE INSTRUCTIONS. Part No &

HIGH FREQUENCY AUTOMATIC BATTERY CHARGER

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

OPERATING & MAINTENANCE INSTRUCTIONS

KING 130 HOT WASHER Part No Product Serial No:...

ELECTRIC CAR POLISHER

CORDLESS TACKER MODEL NO: CCT48 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0414

1200W INVERTER GENERATOR

SUBMERSIBLE DIRTY WATER PUMP

VARIABLE SPEED JIG SAW

HYDRAULIC PALLET TRUCK

GENERATOR MODEL NO: FG2500 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0114

ELECTRIC IMPACT WRENCH

18V CORDLESS STAPLER/NAILER

SUBMERSIBLE WATER PUMP

MONZA OIL FREE AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS

18V CORDLESS DRILL MODEL NO: CON18LiC

Car Battery Charger Instructions for Use

ELECTRIC IMPACT WRENCH

BATTERY BOOSTERS / CHARGERS BC120N BC130N BC210N BC320E BC410E BC520N

12V OIL & DIESEL PUMP MODEL NO: CFTP12

PORTABLE SANDBLASTER HOPPER KIT MODEL NO: CPSB1

3KVA DUAL VOLTAGE GENERATOR MODEL NO: PG3800DV

GENERATOR MODEL NO: FG3000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0609

HEAVY DUTY BATTERY BOOSTERS / CHARGERS. MODEL Nos. BC260N & BC335 OPERATING & MAINTENANCE INSTRUCTIONS

MODEL No. BC 700. Par t No OPERATING & MAINTENANCE INSTRUCTIONS

OIL DRAINER MODEL No: COD70. Part No: ASSEMBLY and OPERATING INSTRUCTIONS 0707

OPERATION & MAINTENANCE INSTRUCTIONS

5.5KVA GENERATOR MODEL NO: PG6500DVES OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0616

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

BATTERY CHARGER-STARTER

12 amp RMS Battery Charger

VEHICLE POSITIONING JACK

18V CORDLESS COMBI DRILL MODEL NO: CON18NI

VARIABLE SPEED JIG SAW

1 ELECTRIC WATER PUMP

WARNING: Read these instructions before using the machine GENERATOR MODEL NO: IG3500F PART NO: OPERATION & MAINTENANCE INSTRUCTIONS

3-TONNE GARAGE JACK OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CTJ3000GB PART NO: ORIGINAL INSTRUCTIONS

COLD WATER WASHER OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. ELS145, 145R & ELS160R. Part Nos , &

GARAGE JACK MODEL NO: CTJ3000QLB PART NO: OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS

BENCH GRINDER WITH LIGHT AND WIRE WHEEL MODEL NO: CBG8370LW

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

LED AC DRIVERLESS FLOODLIGHTS WITH PIR FOR MODEL: FLAC10BPIR, FLAC20BPIR, FLAC30BPIR & FLAC50BPIR

SWIMMING POOL PUMPS Models SPP07, SPP10 & SPP15 Part Nos: , &

GARAGE JACK MODEL NO: CTJ3000G PART NO: OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS

720W PORTABLE GENERATOR

ARC ACTIVATED HEADSHIELDS

6 x 10 Belt Disc Sander

2 TONNE TROLLEY JACK

Transcription:

28W WORK LAMP Model: CTL28 Part No: 4002905 INSTRUCTION MANUAL GC0609

INTRODUCTION Thank you for purchasing this CLARKE 28W Work Lamp. Before attempting to use the product, it is essential that you read this manual thoroughly and carefully follow all instructions given. In doing so you will ensure the safety of yourself and that of others around you, and you can also look forward to the product giving you long and satisfactory service. GUARANTEE This CLARKE product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase. Please keep your receipt as proof of purchase. This guarantee is invalid if the product is found to have been abused or tampered with in any way, or not used for the purpose for which it was intended. Faulty goods should be returned to their place of purchase, no product can be returned to us without prior permission. This guarantee does not effect your statutory rights. ENVIRONMENTAL PROTECTION Do not dispose of this product with general household waste. All tools, accessories and packaging should be sorted, taken to a recycling centre and disposed of according to the laws governing Waste Electrical and Electronic Equipment. SPARES & SERVICE CONTACTS For parts & servicing, please contact your nearest dealer, or CLARKE International, on one of the following numbers. PARTS & SERVICE TEL: 020 8988 7400 PARTS & SERVICE FAX: 020 8558 3622 or e-mail as follows: PARTS: Parts@clarkeinternational.com SERVICE: Service@clarkeinternational.com 2

GENERAL SAFETY PRECAUTIONS WORK ENVIRONMENT 1. ALWAYS keep the work area clean and tidy. 2. ALWAYS keep children and visitors away from the work area. 3. Although the lamp may be used outdoors, DO NOT leave it exposed to the elements. Avoid direct sunlight, direct heat, rain/moisture etc. 4. ALWAYS keep body and clothing dry. Never work in damp area without adequate insulation against electric shock. GENERAL USE 1. ALWAYS check for damage before using the lamp. Inspect the power cable and plug for damage and make sure that no connections are loose. Any damage should be properly repaired or the part replaced. Consult your CLARKE dealer. 2. NEVER modify the plug in any way. Do not use adaptor plugs with earthed (grounded) power tools. Correct plugs and outlets will reduce the risk of electric shock. 3. ALWAYS disconnect from the mains supply before moving or performing any maintenance. 4. NEVER move your lamp or replace fluorescent tubes or broken parts with wet hands or when standing on a wet or damp surface or in water. Always ensure the power supply is disconnected at the mains. 5. ALWAYS use an outdoor weatherproof socket when using the lamp outdoors. 6. NEVER abuse the mains cable or yank the cable to disconnect it from the socket. Keep the cable away from sharp edges/hot surfaces. 7. NEVER cover the lamp. 8. ALWAYS disconnect from the power supply when not in use. 9 NEVER immerse the lamp in water. 10. ALWAYS store this product in a dry, secure place out of reach of children. 11. NEVER carry out any alterations or modifications to this product. 12. NEVER use this product if it is defective/operating abnormally. Please keep these instructions in a safe place for future reference. 3

ELECTRICAL CONNECTIONS Connect the mains lead to a standard, 230 Volt /50Hz electrical supply through an approved 13 amp BS1363 plug, or a suitably fused isolator switch. WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: The wires in the mains lead should be wired up in accordance with the following colour code: Green & Yellow - Earth Blue - Neutral Brown - Live Connect the GREEN & YELLOW coloured cord to the plug terminal marked with a letter E or Earth symbol or coloured GREEN or GREEN & YELLOW. Connect the BROWN coloured cord to the plug terminal marked a letter L or coloured RED. Connect the BLUE coloured cord to the plug terminal marked a letter N or coloured BLACK If this appliance is fitted with a plug which is moulded on to the electric cable (i.e. non-rewireable) please note: 1. The plug must be thrown away if it is cut from the electric cable. There is a danger of electric shock if it is subsequently inserted into a socket outlet. 2. Never use the plug without the fuse cover fitted. 3. Should you wish to replace a detachable fuse carrier, ensure that the correct replacement is used (as indicated by marking or colour code). 4. Replacement fuse covers can be obtained from your local Clarke dealer or most electrical stockists. FUSE RATING The fuse in the plug must be replaced with one of the same rating and this replacement must be ASTA approved to BS1362. We strongly recommend that this machine is connected to the mains supply via a Residual Current Device (RCD). If in any doubt, consult a qualified electrician. DO NOT attempt any electrical repairs yourself. 4

TECHNICAL SPECIFICATION Feature Specification Weight Dimensions (d x w x h) Supply cable length Input voltage 2.3 kg 149 x 269 x 272 mm 1650 mm 230V/50 Hz F luorescent Tubes 28W (2D) Light output 3420 lux @ 300 mm I nsulation Class IP54* Please note that the details and specifications contained herein, are correct at the time of going to print. However, CLARKE International reserve the right to change specifications at any time without prior notice. USE OF THE WORK LAMP The folding carrying handle can be used as a hook to suspend the lamp from a fixed point or overhead line. Use the holes to facilitate fixing to a flat surface using suitable screws or bolts (not supplied) The socket at the rear of the worklamp can be used as an extension socket (max 13 amps) for secondary applications in dry conditions. *The IP54 (splash & dustproof) rating only applies when the sockets are closed and the product is used with an external waterproof socket. SPARE PARTS Description Part No Description Part No Starter KNKCTL24301 Fluorescent Tube KNKCTL24302 Mains Cable KNKCTL24303 Ballast KNKCTL24304 Transparent Cover KNKCTL24305 Rubber Surround KNKCTL24306 5

MAINTENANCE Keep the unit clean by wiping with a dry cloth. DO NOT use solvents as a cleaning agent. Check the power cable to ensure it is sound & free from cuts / cracks etc. REPLACING A FLUORESCENT TUBE OR STARTER Before attempting to replace the tube, ensure the lamp is switched off and isolated from the main electrical supply by removing the plug from the socket. Allow the lamp to cool down for a few minutes after switching off, before performing any maintenance tasks. Handle the fluorescent tube using either a glove or a piece of cloth wrapped around the tube. 1. Pull off the rubber surround from around the fluorescent tube and lift away the transparent front cover. 2. Remove the lamp centre cover by pinching the sides together. 3. Pull the tube assembly from the frame where it is held by four fixing pins. 4. Replacing the fluorescent tube unit is a reverse of the above process, taking care that the four pins of the fluorescent tube line up with the corresponding four holes inside the connecting base socket. Press the fluorescent tube into place. 5. To remove a defective starter, simply twist it gently anti-clockwise and pull it from its socket. 6

DECLARATION OF CONFORMITY 7