J L I e x h a u s t h o o d

Similar documents
KVI Kitchen Canopy With Capture Air

KWF Water Wash Canopy with Supply Air

Hoods for professional kitchens

JSI/JLI TURBO HOODS. Installation, adjustment and user guide

Hoods for professional kitchens

KSOM Control exhaust valve

KWT GALLEY WATER WASH HOOD GALLEY WATER WASH HOOD KWT. With supply air and Capture Jet technology

KTI Supply air valve. Product Facts. Product code example. Quick Selection

Zest Iris Duct Dampers

OPTIVENT Housing HVSA, HVSL

Filter Hood Model CA-S

ADAPTTM. Extract. Extract air diffuser for the WISE system. Quick Selection

THB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser

2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m

STI Supply air valve. Specifications. Quick Selection. Product code example Supply air valve STI-160-C

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

Front panel Perforated galvanised steel Stainless steel AISI 316 as option Casing Galvanised steel Stainless steel AISI 316 as option

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

HMR DUAL DUCT CABIN UNIT CABIN UNITS HMR. For passenger and crew cabins

KTS Supply air valve. Specifications. Quick Selection (50 Pa) Product code example Supply air valve KTS-100-C

Exhaust air diffuser HPKH + Plenum box ATTS

Duct Nozzle Diffuser. L e

DATASHEET PRODUCT CODE EXAMPLE:

series RVV Variable flow rate controllers

Adriatic for individually suspended installation Exposed active climate beam with cooling, heating and ventilation

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

KSOF Fire damper valve

KVR Capture Jet. KVR- Capture Jet Round Island Hood with Perimeter Jets. Round Island Hood with Perimeter Jets

IrisControlDamper. For Adjustment and Measuring of Airflow.

NEW. Iris Control Damper (ICD) For adjustment and measuring of airflow. Features. Quick and simple installation and maintenance

AHF - Exhaust Grille. Halton AHF. Exhaust Grille

HME SINGLE DUCT CABIN UNIT CABIN UNITS HME. Sound attenuator and balancing box

CornerAir. CornerAir. Active chilled beam

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

DKR - Multi-nozzle Ceiling Diffuser. Halton DKR. Multi-nozzle Ceiling Diffuser

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser

HDF - Exhaust Grille. Halton HDF. Exhaust Grille

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

High Performance Fan Coils FCHG Genesis Series Horizontal

ADAPTTM. Sphere. Active communicative, supply air diffuser for the WISE system. Quick Selection

PELICANTM. Wall. Rectangular perforated wall air diffusers for supply air. Quick guide

ACTIVENT System. Specifications. Product code example ACTA

Extract-air grille with ATK plenum box

Supply air diffusers RHKH and RHOH / Supply air units RHKB/RHOB (=RHKH/RHOH+ATTD)

TBV - Terminal Unit. Halton TBV. Terminal Unit

TUBUS TUBUS. Key figures. Function Wall-mounted supply air diffusers

For installation into ductwork

DFA - Conical Ceiling Diffuser. Halton DFA. Conical Ceiling Diffuser

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R

5/S1 KITCHEN HOODS NZK, NZR, NZP, NSK, NSR, NSP, NES, NEZ. v 2.6 (en)

KVL-P with Plate Shelf

EAGLE Wall. Wall air diffusers with discs for supply air and flush mounting QUICK FACTS

ADAPTTM. Free. Active communicative, supply air diffuser for the WISE system, ADAPT F

TRH - Plenum for diffusers. Halton TRH. Plenum for diffusers

Exhaust air diffuser EYMA-2 and air intake device DYMA-1

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS

Nozzle diffuser DYRH / Supply air unit DYRB (=DYRH+ATTD)

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

DKS - Multi-nozzle Ceiling Diffuser. Halton DKS. Multi-nozzle Ceiling Diffuser

THL - Conical Ceiling Diffuser. Halton THL. Conical Ceiling Diffuser

Supply air unit DYBA. Specifications. Connbox. Quick Selection DYBA, without slot, 1:3 plenum box ATTC (50 Pa)

4/S6 VAV DAMPERS RVP-C, RVP-P, RVK RVP-C-T, RVP-P-T. v 2.5 (en)

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

Ceiling swirl diffusers

Ceiling swirl diffusers with perforated face plate

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

BRC

KVM KVM. Capture Jet Hybrid Backshelf Hood. Capture Jet TM Hybrid Backshelf Hood

Extraction arm FX100 Original

RETROFIT TERMINAL UNITS

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

Regulation and shut-off damper SPB and SPC

PART MATERIAL PART MATERIAL. Casing Hot galvanized steel / Option: stainless steel EN (AISI316L) Reheat coil EN 1.

Ceiling swirl diffusers

KGEB Exhaust valve. Specifications. Quick Selection. Product code example Exhaust valve KGEB-100-C Mounting ring KGEZ-01

Model ND-2 Specification

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts

Accessories. Front vane panel Coupling sleeve with gasket Galvanised steel Gasket of rubber compound

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Wall air diffusers with discs for supply air and flush mounting. Quick guide COLIBRI WALL

Casing Hot galvanised steel / Option: stainless steel EN (AISI316L) Reheat coil EN (AISI 304)

ULA - Valve. Halton ULA. Valve

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Twin and Single Inline Fans. Offers a range of flexible installation and application options, including auto-changeover on the Twin range

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

Product Data. Features/Benefits. 36CBAC,AE,AF,AN, PB,PD,PS Series Active and Passive Chilled Beams. 11 to 190 cfm

CONSTANTFLOW Volume Flow Controllers

5/9.2/EN/6. Volume Flow Limiter. Type VFL for insertion into air ducting. The art of handling air

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Ceiling swirl diffusers

Supply air diffusers RPPH and ROPH / Supply air units RPPA/ROPA (=RPPH/ROPH+ATTD)

HOODS HOODS PLAY AN IMPORTANT ROLE IN THE KITCHEN, BOTH AESTHETIC AND FUNCTIONAL. DESIGNED. Range Versatility

C O L M A N. Air Distribution JET DIFFUSERS DCJ SERIES DCJ SERIES

ROOFMASTER STEF-HT ROOF FAN

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

Krantz. Floor displacement outlet Q-B-DN 200. Air distribution systems

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

Transcription:

JLI exhaust hood

PAGE Table of Contents Product description & Product code Functioning principle, Parts Dimensions Positioning, Design Service Exhaust air 7 Pressure loss & Sound data, Lights 8 We want to help you in design of ventilation by offering Jeven designer service to your disposal. Design Service helps in design and makes unique proposal solution with Jeven products. Contact us: jeven@jeven.fi 00 00

PRODUCT DESCRIPTION The Jeven JLI hood has been designed for light duty kitchens where exhaust-only hoods are needed or supply air units are impossible to install. JLI hoods are equipped with filter units, damper plates and measurement taps. JLI is equipped with special filter units, which are easy to wash in a dishwasher. LIGHTS AND FILTERS All Jeven hoods come equipped with lights. Standard JLI hoods are equipped with cyclonic JCE grease filters. MATERIAL The canopy s base material is stainless steel AISI 0. The side panels can be made of stainless steel (JLI-R) or laminated glass (JLI-S). ACCESSORIES Covering boards to enclose the area between the top of the hood and the ceiling. PRODUCT CODE JLI - R 000 x 00 x 0 - x - 080 m/h - CB Seinämateriaali R= Stainless steel S= Glass Length Width Height Number and size of the exhaust air connections Exhaust air flow, m/h Accessories CB=Covering boards PAGE

PAGE FUNCTIONING PRINCIPLE. Heat and impurities rise into the hood.. Grease particles are removed in the filter. Clean air is exhausted. PARTS. Outer casing. Light fixture with a cable. Grease filters and measurement tap for exhaust air. Exhaust air connection and damper plate. Ceiling console. Hanging bracket

SIVU DIMENSIONS Island type hood Wall hood A xw Module JCE B JCE xw Module Module Module xw xw width width B Y A A JCE JCE A (module) length xw xw length Y-Y 7 height height 7 width width Hoods length, width and A, B-dimensions can be chosen freely. Max. module size is 000mm x 800mm. Filters require 0 mm of free space to open. Y (module) A-A

PAGE POSITIONING X 00-00 The size of the canopy is determined by the size of the kitchen equipment. The overhang depends on the type of equipment and the distance between the hood and the equipment. For this type of equipment, the overhang should be at least 00 mm. The typical distance between the hood side and the floor is 00-00 mm. If the equipment has any doors that open upwards, make sure there is enough distance to the canopy. >0. *X >00 Oven DESIGN SERVICE Jeven Design Service helps you choose the best solution for your professional kitchen project. Simply email us a drawing of the kitchen lay-out and a list of the cooking equipment to jeven@jeven.fi We will do all the calculations and prepare all the necessary drawings of the canopies. This service is always free of charge to you.

EXHAUST AIR The recommended exhaust airflow rate is max. 0 l/s per mm spigot, with a duct velocity of. m/s. By default, the canopies come with a suitable number of filter units so that the pressure level will be between 0 and 0 Pa. The nominal airflow of the filter units is 0 l/s per filter module. GREASE FILTER EXTRACTION RATE Extraction rate( % ) 00 90 80 70 0 0 0 0 0 0 8 Particle size ( µm ) Pressure loss> 0 Pa Pressure loss> 00 Pa Recommended exhaust flow / spigot Spigot size ø mm 00 00 Exhaust flow l/s m/h 0-0 - 00 0-0 00-0 - 0-90 SIVU 7

PAGE 8 LIGHTS Pressure loss 80 70 0 0 db(a) =0 8 Ps (Pa) 0 00 Number of filter modules 78 0 PRESSURE LOSS AND SOUND DATA B db(a) =0 0 0 80 00 0 00 0 00 00 800 l/s 0 0 00 00 00 700 000 00 00 m³/h 800 Sound power level Lw in each octave band is computed by adding the corresponding factor, Kok to the sound power level LpA. Lw= LpA+Kok. Light fixture as standard IP -7 T8: B=mm, (x8w, xw, x8w) B=8mm, (x8w, xw, x8w) Colour temperature 80(Cool White) About m cable, type EKK x, Factor, Kok Hz Kok tol. ± 0 ± 00 000 000 000 - -9 - ± ± ± ± By default, every hood module comes with a light fixture. The light fixture has a cable which should be connected to a junction box with a cable lock. The junction box is not included. SOUND ATTENUATION Exhaust JCE-, spigot = ø 00 mm. Sound attenuation, (db) Hz Damper closed Damper open 0 7 00 000 000 000 7 0 0 0 0 00 000 000 000 0 0 7 Exhaust JCE-, spigot = ø mm. Sound attenuation, (db) Hz Damper closed Damper open 9..0 The average sound attenuation includes the end reflection of the connection spigot. It is recommended to use damper open values when calculating sound attenuation