User Instructions for WRC1021D. Doc

Similar documents
RDx-xxxDT Installation. Contents. Mounting: Holes for a mounting bracket. Holes are threaded for ¼-20 and are approximately.275 deep.

th Street, Surrey, B.C. Canada V3W 0A6 Telephone Fax July 2012

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (0-10VDC Input Version)

Linear Actuator Swing Gate Operator Installation Manual Model # LA405-24

EG1069X. Generator Electronic Governor Controller Operation Manual

PSM72H Push-Button Start Module

Spray Height Controller

PEAKTRONICS DMC-101 ADDITIONAL FEATURES. DC Motor Controller, 5A DMC-101

TECHNICAL DATASHEET#TD1516AX 3 AMP SOLENOID DRIVER

Starting System DS-102 Series 200. Elmatik AS P.O.Box 309 NO-3471, Slemmestad T F

12 Series Linear Actuators. Operation & Maintenance Manual, Analog Positioner Installation

LIPPERTCOMPONENTS, INC.

CABINET REEL OPERATING INSTRUCTIONS

ESC2301. Universal Electronic Governor Controller Operation Manual

DMC mA Positioner

BX88175 Installation Instructions ToadStop II Vacuum Brake System

WARNING This manual should only be used by a qualified Service Technician. FinishPro 390/395 Airless/Air-Assisted Sprayer Repair Electrical Manual

MT50 & MT150 Electrical Multi-turn Valve Actuators

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

TABLE OF CONTENTS. 8.3 Online Sensor Specifications. Series TS (Models TS1, TSP, TSH, TSL,TSF, TSB1, TSB2) According to Electromatic factory procedure

B100S - Super Swing. Instruction Manual. Document number: B100S-C Release: V4.0 Date: May 08,2009

DFC-1 STANDARD TEMPERATURE CONTROL. DFC-2 TEMPERATURE CONTROL w/ INTEGRAL 40 F-90 F SELECTOR DFTD TEMPERATURE SELECTION DIAL DFTS TEMPERATURE SENSOR

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

17429X.00 SERIES MODELS:

Section 55 Chapter 6

F ERNI K I T THE FERNI-S KIT CONSISTS OF:

1. AC VOLTS: Displays generator output in voltage. 2. AC FREQUENCY: Displays the speed of the generator set in Hertz.

ESD5550 / 5570 Series Speed Control Units

JBI Docupunch P33 Automatic Punch

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

CONTROLLER DIAGNOSTIC GUIDE

EG3000. Generator Electronic Governor Controller Operation Manual

P3 3-STOP POSITIONER IOM

EG1065X. Compatible with Barber Colman* Dyn1-1065X series * Use for reference purpose only and not a genuine Barber Colman product.

TECHNICAL MANUAL AND ELECTRONICAL MODULE REGULATION VVVF-4 +

DENISON HYDRAULICS Jupiter 500 Driver Card Series S

Flight Systems. Replacement for KASSEC DESCRIPTION

Troubleshooting Guide

Troubleshooting Guide

APPLICATION NOTES VALVE CHECKER M

RODIX, INC. FC-40-PLC Plus Series Control Troubleshooting Guide for Circuit Board P/Ns and

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved

APPLICATION NOTES PQ VALVE CHECKER G A002

DTS SECURITY P.O.BOX 3399 EDENVALE 1610 Base plate-mounting instructions TELEPHONE

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved

OIL FIELD ELECTRIC ACTUATOR INSTRUCTION MANUAL SPECIAL APPLICATIONS ACTUATORS Q 6.0.1

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

EPM72 Engine Protection Module

Electric Modulating Actuator Installation, Operation & Maintenance Manual

ANALOG CONTROL PANEL

VLP-UL-KIT INSTALLATION INSTRUCTIONS. The VLP-UL-KIT for 36 or 48 is a field installable solenoid latch pullback for the Von Duprin 33/35 &

2-Way & 3-Way Non Spring Return Characterized Ball Valves

12 Series Linear Electric Actuator Installation, Operation & Maintenance Manual

Electro-Pneumatic Positioner Series 830/831-WP/EX. Operation & Maintenance Manual

ELECTRIC FENCE ENERGIZER SERVICE MANUAL MODEL 950 SERVICE MANUAL FOR OLLI 950 FENCE ENERGIZERS

Remote Temperature Controller for Heated Mold Shoes, using a RTD/Digital Display, # C (version pre-2009).

Three Function Remote Control System with Alarm (Model RCA-3)

FAULT CODE 474. Starter Solenoid Lockout Relay Driver Circuit

Sensors W2 and E2 are optional. Installation guide, 'Pickle Fork' Back-and-Forth Model Train Controller

TA-05/C. Instruction and Operation Manual. valid for art.-no.: F-TA-05/C-ISO. (start at modification No. 1601)

DC-Motor Controller. User Manual

TD1512AX Technical Data. REMOTE MOUNT SOLENOID DRIVER (4-20mA Input Version)

Inlet Controller SB3500 USER'S MANUAL

Service Manual Temperature Calibrators JOFRA CTC-140/320/650 A/B, CTC-1200 A JF INSTRUMENTS MTC-140/320/650 A Copyright 2003 AMETEK DENMARK A/S

ELECTRICAL. Contents - Wiring Diagrams

ENGINE GOVERNING SYSTEMS

MODULATING SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

Oper pe ati t ng i Presented by:

ELECTRIC SCHEMATICS LS1 LS2. "1532ES / 1932ES" Service & Parts Manual - ANSI Specifications March 2008 Page 5-9 ART_2236 ART_2243

INSTALLATION INSTRUCTIONS 464, 424 & 324 POST-MIX VALVES

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

Twin Power. Manual. Pneumatic Multiturn actuator in Standard and ATEX design WARNING! WARNING! Mounting. Assembly example

Gate & Door Controller with LCD and Intelligent Technology

GLM SERIES CONTROL Users Manual Rev:


ASSEMBLY INSTRUCTIONS FOR NEW FK109 4 LED Railroad Crossing Flasher Kit WITH ADJUSTABLE FLASHING SPEED CONTROL with 4 Red 3mm Leds

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

DC3R Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC

TWO-WAY LED MANUAL TRANSMISSION REMOTE STARTER. User Guide WARNING



Eaton Electronic Proportional (EP) Control for Medium Duty Piston Pumps

Operating Instructions. Angle Seat Control Valve. Type 7020

OWNER S MANUAL MODEL: PT 450 / PT 450M WELDING POSITIONER

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

Table of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION...

Operating manual and installation instructions ENGLISH. Electronic engine remote control. Copyright 2001 Vetus den Ouden n.v.

MANUAL TROUBLESHOOTING. ECM Motor. ECM / ECM-DX Series. v100 Issue Date: 08/15/ Price Industries Limited. All rights reserved.

Electronic Refrigerator Diagnostics

MicroGuard 586 Retrofit Rated Capacity Indicator System. Calibration and Testing for:

PM300E Voltage Regulator Instruction Manual

CHUBBSAFES EVOLVE INSTRUCTION MANUAL

Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

RUS-L24-MOD Electric 24 Volt Modulating Control Damper & Louver Actuator

CRUISE CONTROL SYSTEM

Baelz-electrodyn Actuator for modulating duty Motorized linear actuator baelz 373-E45

SmartX MF and MS

Table of Contents. Timer Identification Timer ID BLU-U Features: 1K 6K BLU-U Features 1K 6K

PM500. Voltage Regulator User Manual. A Regal Brand. Scan here for other languages.

MVE2XX. Globe Valves Actuators. Power. Model Force (N)

Transcription:

User Instructions for WRC1021D Doc. 0001-5989

CONTENTS 1.0 INTRODUCTION TO THE WRC1021D... 2 2.0 FUNCTIONAL DESCRIPTION... 3 3.0 POTENTIOMETERS, SWITCHES AND INDICATORS... 5 4.0 CALIBRATION AND START-UP OF WRC1021B CIRCUIT BOARD... 7 5.0 THE FEEDBACK POTENTIOMETER... 9 6.0 SERVO SYSTEM... 12 7.0 ERRORS AND TROUBLESHOOTING.... 13 Årsundveien 24, N-6270 Brattvåg, rway 1

1.0 INTRODUCTION TO THE WRC1021D The WRC1021D remote controller is a replacement for the older type WRC1021 boards. It is 100% mechanical and functional compatible with the older WRC1021. WRC1024D are designed with modern SMD technology to extend the life time. TECHNICAL SPECIFICATIONS Power Supply 230V AC/50 60 Hz 24V DC Power Consumption 220V 0.04A (no servo valves connected) 24V 4.0A Max (depending on Output Limit alarms) Max Output Servo Drivers 1.5A 220VAC Max Output Limit alarms 2.0A 24VDC (Absolute max. rating). Board Dimensions 100 x 160 mm Euro Card Board Weight 385 grams Item id 000070089 WRC1021D is produced with serial nr. and product revision number. Refer to these numbers when you request for service. Ser.. yynnnn PRnn Årsundveien 24, N-6270 Brattvåg, rway 2

2.0 FUNCTIONAL DESCRIPTION Order Potentiometer Limit alarm 1 Feedback Potentiometer Limit alarm 2 Slave Order Potentiometer WRC 1021 Hoist valve Lower valve Command shift Full hoist Bypass valve Option Minimum configuration Fig.1 Block Diagram The WRC1021D remote controller compares current order signal with the feedback signal. The system may have two orders one main order and one slave order, which is selected via the Slave order signal. If order and feedback are out of balance the WRC1021D board will set the servo valve outputs according to the signal difference. When balance is achieved the valves will go inactive and hold this position until the order takes a new position. The bypass will open if the order has been left in neutral position for 7 seconds (if this option is not disabled), or an error is detected, such as signals out of range. Årsundveien 24, N-6270 Brattvåg, rway 3

Fig. 2 Electrical connections. Options - R2 Slave potentiometer - S1 Disconnects order pot.meter and sets the manoeuvring handle in full hoist pos. - S2 Disconnects main order and connects slave order input. - S3 Reduces the speed of the manoeuvring handle. - K1 0VDC output when the manoeuvre handle is in alarm area 1 - K2 0VDC output when the manoeuvre handle is in alarm area 2 24VDC Supply is not necessary if none of the options are connected. Årsundveien 24, N-6270 Brattvåg, rway 4

3.0 POTENTIOMETERS, SWITCHES AND INDICATORS Fig. 3 Board Layout Trim. Potentiometers Dip Switches Led Indicators P1 Full hoist Position S1.1 Alarm2 Invert DL1 5V Indicator P2 Full hoist Speed S1.2 Alarm1 Invert DL2 Running P3 Alarm2 Limit S1.3 Flushing DL3 Hoist Open P4 Alarm1 Limit S1.4 t in use DL4 Lower Open P5 Deadband S1.5 Creep Drive DL5 Bypass Closed S1.6 Disable Auto Bypass DL6 Alarm2 S1.7 Set Full hoist DL7 Alarm1 S1.8 Calibration Årsundveien 24, N-6270 Brattvåg, rway 5

P1 Adjusts the winch manoeuvre arms position when a full hoist signal is applied. Turning the pot meter counter clockwise will move the arm against hoist. Shall stop 3-5 mm from end-stopper on valve unit. P2 Adjusts the winch manoeuvre arms speed, when moving to full hoist position when a full hoist signal is applied. The speed increases when pot meter is turned counter clockwise. P3 Adjusts the position at which the Alarm2 will be activated. Since it is activated via the feedback signal it will be fully functional even when the winch is manually operated. The Alarm2 limit moves towards lower when pot meter is turned clockwise. (Factory setting: approx 10% lower, terminal no. 21). P4 Adjusts the position at which the Alarm1 will be activated. Since it is activated via the feedback signal it will be fully functional even when the winch is manually operated. The Alarm1 limit moves towards lower when pot meter is turned clockwise. (Factory setting: approx 50% lower, terminal no. 20). P5 Adjusts the systems Dead band. The Dead band increases when pot meter is turned clockwise. S1.1 If this switch is set Alarm2 function will be inverted. Where it was active it will now be passive and vice versa. S1.2 If this switch is set Alarm1 function will be inverted. Where it was active it will now be passive and vice versa. S1.3 Sets the valves in flushing position, to simplify the flushing operation. Signal for full hoist and close bypass will be set, regardless of the order and feedback pot meter are connected or not. S1.4 t in use. S1.5 This switch will enable the possibility to creep drive for special modes. S1.6 This switch will disable the automatic bypassing function (7 sec. Auto bypass). S1.7 Forces the winch to full hoist position set by P1. (Used during adjustments.) S1.8 This switch set the card in modus for calibration. Earlier memory will be deleted when you operate this switch. Operate the remote controls and the manoeuvre handle to maximum range. Set the switch in off position. Calibrated values are now saved. L1 When lit, indicates that the circuit board power supply is delivering 5V. L2 When blinking steadily, it indicates that the program is executing normally. When blinking rapidly, it indicates error in order or feedback potentiometer circuit. L3 When lit, the Hoist output is energizing the Hoist valve and opens it. L4 When lit, the Lower output is energizing the Lower valve and opens it. L5 When lit, the Bypass output is energizing the Bypass valve and closes it. L6 When lit, the Alarm2 output in active. L7 When lit, the Alarm1 output in active. Årsundveien 24, N-6270 Brattvåg, rway 6

4.0 CALIBRATION AND START-UP OF WRC1021D CIRCUIT BOARD How to calibrate / adjust circuit board WRC1021D after replacing circuit board and/or change of feedback potentiometer on winch. NOTE: Make sure that all main pumps are OFF and servo-pump is ON during calibration/adjustment of WRC card. See fig.3 for circuit board layout. 1. Calibration of control lever on winch. Make sure that all control levers are standing in correct stop position. Activate dipswitch number 8 on WRC card. Operate the control lever on winch to full hoist and then to full lower. Operate joysticks on bridge panel to full hoist and then to full lower. Operate joysticks on deck panel, if present, to full hoist and then to full lower. Deactivate dipswitch number 8 on the WRC card to store the calibration values into the card. 2. Calibration of dead band. The dead band value is adjusted using pot meter number 5 on the WRC card. Clockwise adjustment will result to a bigger dead band. Counter clock-wise adjustment will result to a smaller dead band. If the control lever on the winch won t settle in stop position, adjust the dead band clock-wise. 3. Adjustment of full hoist position in auto mode. Use dipswitch number 7 to activate the full hoist mode on the WRC card (dipswitch number 7 activates the WRC card in the same way that a full hoist signal from the control system). Adjust full hoist on the winch control lever by using pot meter P1 on the WRC card. Turn dipswitch number 7 off when the full hoist position is properly adjusted. Use pot meter P2 to adjust the control lever movement time from stop to full hoist position when full hoist command is activated. Adjust the control lever movement time to approx 10 seconds. 4. Activating Creep drive function. On anchor handling and towing winches the last few years, the function creep drive is implemented to avoid damage on gear during coupling in. Activate dipswitch number 5, and make sure that P2 is adjusted as described in above chapter. Adjust movement time to approx 10 seconds. 5. Digital output channels on WRC card. On winch deliveries during the few last years, there are mounted valves that lead some of the oil around the winch manoeuvre valve and directly into the motor. These valves, together with other valves on pipe- and pump-arrangement, are partly controlled from the WRC 1021 circuit board. Årsundveien 24, N-6270 Brattvåg, rway 7

The WRC card uses two digital output channels called Alarm 1 and Alarm 2 to control this function. The use of Alarm 1 and Alarm 2 changes from installation to installation. Use the circuit diagrams for each installation to determine how the WRC card output channels are used. The relays set point is adjusted with pot meter 4 for Alarm 1 and pot meter 3 for Alarm 2. The relay function can be inverted using dipswitch number 2 for Alarm 1 and dipswitch number 1 for Alarm 2. Diode L7 is lit when Alarm 1 is active and diode L6 is lit when Alarm 2 is active. Potentiometers number 3 and 4 on the WRC card ( Alarm 1 and Alarm 2 set point) is normally adjusted such that the digital output channels are activated when manoeuvre valve on winch reaches 80-90% of full hoist signal. Årsundveien 24, N-6270 Brattvåg, rway 8

5.0 THE FEEDBACK POTENTIOMETER. The feedback potentiometer, usually are of 2 k ohm type. To achieve optimum performance an original potentiometer should be used. Part no. 818-640-00, or spare part kit including seals, part no. 000001943. tes: 1. If oil leakage, pos. no. 7. and 9. to be changed. NB! Remember to remove expansion pressure in the hydraulic system before dismantling! Pos no. Qty. Description 2 2 Seal Washer 4 1 O-ring 7 1 Gasket 9 1 U-ring 18 1 Potentiometer 2. If only potentiometer pos. no. 18 to be changed, removal of expansion pressure is not necessary, as long as Device housing is not dismantled. 3. When finished replacing the potentiometer, the lever is to be moved in fully hoist/lower position. This is to ensure proper mechanical function of the feedback potentiometer. Årsundveien 24, N-6270 Brattvåg, rway 9

Earlier feedback potentiometer has a different mechanical solution, see Fig. 4. 100 ohm feedback potentiometer has item no. 240-682. 1 Kohm has item no. 151-604- 04. To upgrade the complete housing to the new version, use item 403-732-00. Fig. 4 Feedback potentiometer adjustments If a potentiometer on the control lever must be replaced, following procedure shall be used. 1- Stop the pumps. 2- Let out the expansion pressure to prevent an oil leakage through the o-ring in figure no.4 3- Remove the cover and indicator housing fastened by the four bolts. 4- Make sure that the wires are marked before disconnecting them. 5- Carefully pull out the indicator housing. 6- Replace the potentiometer, to avoid damage of potentiometer and oil spill, make sure the potentiometer pin and O-ring are correctly fitted before the bolts are tightened. 7- Potentiometer to be adjusted in centre when lever is in stop position. 8- Readjust the feedback as described in chapter 4. Årsundveien 24, N-6270 Brattvåg, rway 10

If the system for some reason is not letting itself be calibrated check the following points. 1- Feedback potentiometer is incorrectly connected, the two endpoint connections has been switched. This is easily checked with a voltmeter at the rear of the WRC1021 rack system, see fig. 2 (electrical connections). Place the black (0V) measuring pin at '9' and the red (+) at '8', now get someone to move the manouver arm against hoist, the voltage should now be decreasing. If not the endpoints must be switched. And while you are at it check the Order and Slave order signals if any. You can keep the black measuring pin at '9' and the red at '11' for Order and '14' for Slave order. The result should be the same, decreasing voltage in hoist, if not take corrective measures accordingly. 2- The servo oil lines are crossed. This must be checked by actuating the valves by means of a screwdriver at the end of solenoid see Fig.5 and visually check that the manouver arm moved correctly. PS. You have to activate the Bypass valve as well, keeping it from bypassing. Make sure the manoeuvre arm is moving against hoist when the A solenoid is manually activated and Lower when B is activated. 3- The servo valves electrical connections have been switched. Try switching the solenoid connectors. When the arm is moving correctly, turn the indicator housing until the manoeuvre arm is exactly in STOP position, then tighten the 4 cover bolts carefully. Årsundveien 24, N-6270 Brattvåg, rway 11

6.0 SERVO SYSTEM Fig. 5 Servo system R8B and R8 Årsundveien 24, N-6270 Brattvåg, rway 12

7.0 ERRORS AND TROUBLESHOOTING. Even when an installation is correctly installed problems may turn up after while. To help during faultfinding we will here present a troubleshooting chart, covering the most common symptoms and causes. The system is divided into an electronic part and a hydraulic part. Simply follow the pointer until the error is located or end of procedure. Start Servo on Switch on L1 on Only this card main fuse wiring Yes fuses on card supply and wiring Replace WRC1021 L2 blinking Slow (1Hz) Switch power off then on Blinking fast (10 Hz) L2 on Replace WRC1021 Yes Set order in stop order and feedback Recalibrate Is L3 or L4 blinking Yes potmeter wirings Recalibrate/ adjust Goto chart for hydraulics Move order to hoist check L3 is blinking and L5 is on Move order to hoist check L4 is blinking and L5 is on that voltage across 9-11 (order) 9-8 (feedback) 9-14 (slaveorder) is following potmeter position Ref. page 12 potmeter Replace potmeter Goto start for hydraulics Goto chart for hydraulics Fig. 6 Trouble-shooting chart electronics Årsundveien 24, N-6270 Brattvåg, rway 13

Start Servo on Switch on Motor running supply voltage and thermal protection Are pressure according to system servo Manually activate bypass valve and lower (Bcoil) Manually activate bypass valve and hoist (Acoil) bypass valve on winch bypass valve on winch bypass valve and hoist/ lower valve Replace solenoid valve for bypass and/ or hoist/lower valve sylinder Service/ replace sylinder Move order in hoist. Manouver arm in hoist? Move order in lower. Manouver arm in lower? solenoid A solenoid B bypass solenoid. wiring Replace WRC1021 And/or solenoid valves OK? Call Service department Fig.8 Trouble-shooting chart hydraulics. Ref. to page 13, servo system principle drawings. Årsundveien 24, N-6270 Brattvåg, rway 14