Spring Mount SAB30403 (Sold Separately)

Similar documents
Sensor SNS06 Shown. Monitor. Toughened Nut Sensor Installation Instructions With thread detection calibration procedures. 1.

PGS Gripper Double Blank Sensors

T84T - Excelon Plus Modular System 3/2 shut-off valve

PGS10 Series Pressroom Gripper System

BL84 - Excelon Plus Modular System Filter/regulator - Lubricator Combination Units

L84M, L84C - Excelon Plus Modular System Micro-Fog and Oil-Fog Lubricators

Description General-purpose models Timer-function models Output NPN PNP NPN PNP Part number E3X-NH11 E3X-NH41 E3X-NH21 E3X-NH51 Appearance

Type 500X. Electropneumatic Transducer (I/P, E/P) Installation, Operation and Maintenance Instructions. Ordering Information.

HDI inch Choke Position Indicator User s Manual Rev Indicator Gauge Linear Potentiometer

Patient Care Facility

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

MODUL-CONNECT 1.2. Owner s Manual. Modular, digital wiring and control system. Document Part Number MSMC Rev 9 (04/18)

Type 500X. Electropneumatic Transducer (I/P, E/P) Installation, Operation and Maintenance Instructions. Ordering Information.

INSTRUCTION MANUAL CAUTION

Patient Care Facility

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

ARC Welder Assembly & Operating Instructions

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

Type 2000 Transducer Product Instructions

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

5001TCP SPEED CONTROLLER

5001TCP SPEED CONTROLLER

PRO REMOTE Series CAPACITANCE PROBE

Installation Instructions

FEATURES. Power Status and Charge Indicator: A red LED indicates the battery is charging and a green LED indicates the battery is fully charged.

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

ICM 326HN/327HN Line Voltage Head Pressure Control Installation, Operation & Application Guide

Application Engineering

PRO REMOTE 25 LV CAPACITANCE PROBE

PCS-250 System Installation Instructions

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

Installation Instructions

EyeMax TECHNICAL MANUAL. Technology, LLC FOR UPDATED INFORMATION, VISIT TABLE OF CONTENTS

Inductive Proximity Sensor

T21 Thermal Differential Switch

DC Variable Speed Drive Panel

XT130B1NAL2 capacitive sensor - XT1 - cylindrical M30 - brass - Sn 10 mm - cable 2 m

DUAL LINEAR MOTOR / ACTUATOR CONTROLLER W/ CURRENT SENSING AUTO REVERSE

AA4006 Speed Sensitive Trip Unit. User Manual

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

CT-930 MANUAL HYDRAULIC COMPRESSION TOOL TABLE OF CONTENTS

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information

DSL-1 E DIESEL TACH INTERFACE UNIT

SERIES PR90H PROGRAMMABLE INCREMENTAL HOLLOW SHAFT ENCODER FOR INDUSTRIAL APPLICATIONS REFERENCE PR90H - C C - C. External diameter 58 mm

TECHNICAL GUIDE. For TOUGH GARD Spatter Cleaner GENERAL SAFETY INSTALLATION MAINTENANCE TECHNICAL DATA ORDERING INFORMATION

Model 550 Series Vibration Switches

NorthStar. brand. Instruction Manual. SLIM Tach SL Thru-Shaft Diameter. Magnetoresistive Encoder Designed for GE Wind Energy

Inductive Proximity Sensor

PRODUCT INFORMATION BULLETIN

EC20 Pocket Conductivity Tester Instruction Manual

MODULATING SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

Model: OBD-L On-Board-Diagnostics II Memory Saver Detector

RP-4000 Reserve Power Control

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

ICM325HN. Head Pressure Control with Optional Heat Pump Override. Installation, Operation & Application Guide

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

The Series I/P Current to Pressure Transducer

Product Features: Removes 99% of free water. Available with 2, 10, or 30 micron Aquabloc II media

MPT-250B SPECIFICATIONS AND OPERATING INSTRUCTIONS

30 Amp Solar Charge Controller

Installation, Operation and Maintenance Instructions Output Range Part Number Input psi bar Impedance Output Range

Technical Description

RF Point Level Control with Sensor Monitor

M-100 Adjustable flow switch with right-angle flow

DMX-A2-DRV Integrated Advanced Step Motor Driver

XXV18B1PAL2 Ultrasonic sensor - M18 metal - Sn 50mm - PNP NO - cable 2m

C1 Controller & Driver. User s Guide

ATP-2040 Electric Damper Actuator/Transmitter

Panel Mount Digital Tachometer Model

R & D SPECIALTIES ROTROL I USER'S MANUAL

BLD75-1. Bilevel Step Motor Driver. User s Guide. 910 East Orangefair Lane, Anaheim, CA

SUREPOWR TM SERIES -SURE 24/25 FIELD INSTALLATION INSTRUCTIONS

1.5 TON ALUMINUM RACING JACK

RV Stabi-Lizer Installation & Operation Manual Effective May 2018

2.5 mm. (0.10 in) E2S -Q25 E2S -Q26. Output configuration. 2.5 mm. End face E2S -W15 E2S -W16 End face PNP

CIRCUIT-TEST OPERATION MANUAL. Switching Mode Power Supply with Remote Sensing PSC V 5A / 0-27V 3A / 0-36V 2.2A (80W)

LEVEL AND FLOW MEASUREMENT WS131 FLOW METER USER MANUAL.

Part Number AEM 4-CH WIDEBAND UEGO CONTROLLER

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Racor 75500FGX Turbine Series fuel

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

Ordering Information. Long Barrel Inductive Prox. E2E2 2-Wire DC. Reduce Wiring to Control Devices with 2-Wire Inductive Prox Sensors

Explanation 1 Input External Switch 2 Input Hipot Safety Switch

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

PXT-K Series. Pressure Transmitters Section 05

INSTRUCTION and OPERATIONS MANUAL. for

PENTEK XE-6. OWNER S MANUAL 6 Submersible Motors 293 WRIGHT STREET, DELAVAN, WI PH: PENTEK

Ultrasonic Two-Wire Point Level Control

Speed Sensors Line Guide

Application Engineering

Inductive Proximity Sensor

APOLLO Gate Operators, Inc.

Materials: 10. Technical Data. VMAA Smart Pump Installation & Maintenance. Table of Contents

Inductive Proximity Sensor

E2EZ-X2D1-N E2EZ-X2D2-N

LION. Application Note LA November, 2015 PRECISION. Using Eddy-Current Sensors For Thread Detection

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved

BLHV, BLHV-1. High Voltage Step Motor Driver. User s Guide. (714) fax: (714) website:

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

Transcription:

1. System Components Spring Mount SAB30403 (Sold Separately) Cable (Sold Separately) 1. System Components: Blue Black To Customer's Control Sensing Area Sensor Power On LED Load On LED Monitor Monitor Adjustment Potentiometer 2. Technical Data Monitor Power/Sensor Connectors: 3 Position Terminal Blocks Sensor Connector: 3-Pin (male) 8mm Pico Type Connector Supply Voltage Range: 10-30 VDC Maximum Continuous Load Current: 150mA Operating Temperature Range 0 C to +60 C Response Time: 25ms Green LED: On When Power Supply is Active Yellow LED: On When Target is Detected Target Material: Ferrous/Non-Ferrous Target Size: See Target Size Tables Short Circuit Protection: Yes (self resetting) Overload Protection: Current Limits at.8a Typ. Reverse Polarity Protection: Yes, Up to 50 VDC Interface: 3-Wire Device: Output (Current Sinking) Output (Current Sourcing) Monitor Housing: Plastic housing sealed to IP65 Sensor Housing: All Steel construction. Housing sealed To IP67 Sensor Housing, Axial Loading: 75lbs. Maximum Sensor Housing, Side Loading: 50lbs. Maximum Missing Probe Detection: Output turns off when probe is disconnected or damaged Patent Number 5617025 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. 2016 Norgren Automation Solutions, LLC 26108 00213SL Rev: 006

Sensor Catalog # Monitor Catalog # Nut Size Minimum Nut Thickness Maximum Blank Thickness Output SMR36005 5mm 4.0mm (0.16") SMR37005 SNP50608 SMR36006 For 6mm 5.0mm (0.20") 1.6mm (0.06") M5, M6 & M8 SMR37006 SMR36008 8mm 6.5mm (0.26") SMR37008 SMR36010 SNP01012 10mm 8.0mm (0.31") SMR37010 For 2.5mm (0.10") M10 & M12 SMR36012 12mm 10.0mm (0.39") SMR37012 Min. Nut Thickness Max. Blank Thickness 3. Wiring Electrical loads up to 150mA, such as control relays, can be driven directly. Power supply voltages may range between 10 and 30 volts DC, and must match the relay or PLC input requirements. 10-30 VDC + LOAD 1 2 3 6 5 Black 4 Blue To Sensor 10-30 VDC + LOAD 1 2 3 6 5 Black 4 Blue To Sensor 02 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. 2016 Norgren Automation Solutions, LLC 26108 00213SL Rev: 006

The sensor cable should not be run near any wires which contain high voltage, high current or a switching load. This can be avoided by running the sensor cable through a metal conduit as shown below, or using a shielded cable for the power / switching line. The sensor cables of multiple nut sensors should not be bundled together (at least 1 cable diameter apart); however, the power/signal cables of multiple monitors may be bundled. Power / Switched Line Metal Sensor 4. Adjusting the Monitor Each monitor is factory assembled to closely match its intended metric nut sensing size (M5, M6, M8, M10 & M12). In addition a fine tuning adjustment (25 turn adjustment potentiometer) is provided to optimize each monitor for variations in clearance hole size, plate thickness, nut thickness, sensor interchangeability, fixture positioning, and usage with English nut sizes. Turning the adjustment potentiometer clockwise will increase the sensitivity (smaller thickness or larger diameter nuts will illuminate the "Load On" LED). Turning the adjustment potentiometer counter-clockwise will decrease the sensitivity (thicker plate thickness or tighter clearance holes will not illuminate the Load On LED in the absence of the nut). Mechanical Alignment of Sensor: A. The typical sized standard and smaller jam or half nuts should be centered within the lines that mark the sensing region on the probe tip for best performance. B. The larger Heavy Duty nuts should cover the entire sensing region including the lines marked on the sensor s probe tip. Monitor Adjustment: A. If the monitor s Load On LED (yellow) does not illuminate with the nut present, then slowly turn the monitor s adjustment potentiometer clockwise until the LED turns on. Turn an additional 4 full turns clockwise. Check that the monitor s Load On LED does not illuminate when the nut is NOT present. B. If the monitor s Load On LED (yellow) remains illuminated with no nut present and the fixtures are engaged, then slowly turn the monitor's adjustment potentiometer counter-clockwise until the LED turns off. Turn an additional 4 full turns counter-clockwise. Check that the monitor s Load On LED does illuminate when the nut is present. 26108 00213SL Rev: 006 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. 2016 Norgren Automation Solutions, LLC 03

Adjustment for Thread Detection Adjusting the monitor for thread detection requires a sample part with threads and a sample without threads. Monitor selection follows the same criteria that is used for nut detection if the threads are in nuts or sheet metal. Monitor Selection for detecting threads in thick plate steel is often a trial and error process. Field trials have shown that the maximum differential between a thread and no thread condition is often a monitor that is not the one normally used for nut or sheet metal thread detection which is based on the thread size. An example would be a 6mm (0.25" thick) steel plate with M10 threaded through hole. Some installations have found that the M10 probe with M6 monitor provided the greatest number of turns of the sensitivity adjustment between detecting threads and no threads. Monitor Adjustment A. Insert probe into part that has threads. Rotate sensitivity adjustment potentiometer counter- clockwise until the load on/nut present light turns off. Slowly rotate clockwise until light turns on and stop rotating. B. Insert probe into part that does not have threads. Rotate sensitivity adjustment clockwise counting the number of rotations. Stop rotating when the load on/nut present light turns on. Record the number of rotations required. C. Divide the number of rotations by 2 and rotate the sensitivity adjustment counter-clockwise that number of turns. This calibration procedure sets the sensitivity halfway between sensing the part with threads and sensing the part without threads. Most applications result in 4 to 6 turns between sensing the part with and without threads. The result will be an output that turns on when threads are present in the part and no output if the threads are not present. 5. Installation Considerations The adjustment potentiometer of the monitor may have to be adjusted to compensate for plate and/or nut thickness. (see section 4 Adjusting the Monitor ). To avoid mutual interference between two nut sensors, a minimum distance of 16mm (0.63") for the M5, M6 & M8 sensors and 21mm (0.83") for the M10 & M12 sensors must be provided. Nearby welding operations will not damage the sensor and monitor, but the monitor may give a false part present indication while the welder is active. All nut detection operations should be performed while the welder is off. 04 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. 2016 Norgren Automation Solutions, LLC 26108 00213SL Rev: 006

6. Dimensional Information: 61.3mm (2.41") 8.8mm (.34") 17.5mm (.69") Clearance for M4 Bolt 50mm (1.97") For 35mm Rail Mounting 55.2mm (2.17") 20mm (.79") 70mm (2.76") English equivalents are approximate. NAS Part Number SCE13000 = 2M Cable SCE13005 = 5M Cable 4.5mm (.18") 8mm (.31") 2 Meters (Max. Length is 8 meters) 26108 00213SL Rev: 006 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. 2016 Norgren Automation Solutions, LLC 05

M5, M6 or M8 Sensor 2.5mm (.10") Sensing Area 6.4mm (.25") Jam nuts (wrench size 13mm) M8 X 1.0 Thread 4mm (.16") 14mm (.55") 7.6mm (.30") 44.5mm (1.75") 68.6mm (2.70") 2.5mm (.10") M10 or M12 Sensor Sensing Area 10.2mm (.40") 17.8mm (.70") Jam nuts (wrench size 13mm) M8 X 1.0 Thread 7.6mm (.30") 44.5mm (1.75") 2.5mm (.10") 33mm (1.30") 80mm (3.15") Warning Improper selection, misuse, age or malfunction of components used in systems can cause failure in various modes. The system designer is warned to consider the failure modes of all component parts and to provide adequate safeguards to prevent personal injury or damage to equipment or property in the event of such failure modes. System designers and end users are cautioned to consult instruction sheets and specifications available from the factory. The system designer/end user is responsible for verifying that all requirements for the application are met. Warranty The products described herein are warranted subject to seller s Standard Terms and Condition of Sale, available at seller s website. Proposition 65: These products may contain chemicals known to the state of California to cause cancer, or birth defects, or other reproductive harm. 06 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. 2016 Norgren Automation Solutions, LLC 26108 00213SL Rev: 006