ExtractAire. Grease Filters for Commercial Kitchen Ventilation Hoods. Baffle. High Velocity Cartridge (HVC)

Similar documents
Model ND-2 Specification

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

KVL-P with Plate Shelf

KVM KVM. Capture Jet Hybrid Backshelf Hood. Capture Jet TM Hybrid Backshelf Hood

KVR Capture Jet. KVR- Capture Jet Round Island Hood with Perimeter Jets. Round Island Hood with Perimeter Jets

EXPERIMENTAL STUDY OF GREASE EMISSION FILTRATION FOR KITCHEN HOOD BY WATER MIST

Filter Hood Model CA-S

KWT GALLEY WATER WASH HOOD GALLEY WATER WASH HOOD KWT. With supply air and Capture Jet technology

Tubular Centrifugal Fans

Roof Upblast and Sidewall Exhaust

Kitchen Ventilation Systems. Exhaust Hoods & Grease Extraction Fire Suppression Systems Accessories

Halton - Advanced Air Purification, Now with ELF Extended Life Filters!

Roof Upblast and Sidewall Exhaust

Efficiency powered to infinity. Nederman Filtac oil mist filters for continuous operation

Air Boss M-Series Media & Adsorption Air Cleaner

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS

ENVIRO UNIT CES SERIES

KVI Kitchen Canopy With Capture Air

Filtered Kitchen Supply Packaged Ventilator

Extraction Arms. Capturing fumes at the source

KWF Water Wash Canopy with Supply Air

Electrical Control Panel

XLR TM. Next generation air filtration

Fume extractor is warranted for two years, parts and labor.

Part 1 of this series discussed optimizing outdoor

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.

Optimizing System Performance

PennBarry Fan Guide Specification. Laboratory Exhaust System: Model vplume

Vline V-LINE WITH POWER LUNG TM COMBINES LUXURY, PERFORMANCE AND VALUE. By Vent-A-Hood


Protector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector

EcoWatt Products. Advancing Ventilation

WELD STRONG BREATHE FREE

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV

Tube Axial Inline Fans

A Division of Nailor International Inc. ECONOMY AIR HANDLERS

Hi-Flo ES. Energy saving pocket filter with guaranteed lifetime efficiency. Energy Saving, Extended Surface Area, High Efficiency Air Filter

Centrifugal Exhaust Fans Series C. Roof Upblast and Sidewall

Product Data. FNCCAB & FILCCFNC High Efficiency Fan Coil Filtration. Sizes 014, 017, 021 & 024. FNCCAB Filter Cabinet. FILCCFNC Media Filter

Requires Ductwork and Blower

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven

FNCCAB & FILBBFNC Sizes 014, 017, 021 & 024

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

Centrifugal Upblast Power Roof Ventilators

SECTION HVAC AIR CLEANING DEVICES

Fabric Pulse Jet Collector Early Designs (Circa 1963)

Scope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

Inline Fans [ 14 ] * UL is optional and must be specified.

an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS CHICAGO BLOWER CORPORATION GLENDALE HEIGHTS, ILLINOIS USA

Introduction to Johnson Controls Dampers

belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07

COMMERCIAL DUTY PLENUM FANS

LEDGELESS VERTICAL CARTRIDGE DUST COLLECTOR

Completing Your Fume Removal System

Air Handling Unit Fan Selection Guide

Direct Gas-Fired Heating

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Factory Option Codes L M E S P R D V F F H E

LINCOLN ENVIRONMENTAL SYSTEMS

FUME HOOD SELECTION GUIDE

TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN

The reference in sandblasting. DCM\DCM 3000 a DCM to series.

TU-WAY ROOF VENTILATORS

Twin City Fan & Blower

EXTRACTION ARMS. Capturing fumes at the source

Alarge portion of kitchen ventilation planning is dedicated to

ENERGY RECOVERY SYSTEM 60 HZ

DW Series - Exhaust Only Wall Canopy

VOLU-probe/SS. Stainless Steel Pitot Airflow Traverse Probes

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD

ZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS

TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS

WSO Mist Collectors. cáäíê~íáçå=qéåüåçäçöó Ñçê=jáëí=`çääÉÅíáçå

nivia utilities Why Air Filters???

WAC Air Curtains Technical Guide

LINEA Low Discharge Roof Exhausters

Mancoolers Models MCY, MCB, MCP

UltraWebisAlwaysBetter.com

BioMAX. Koch Filter Corporation. A Complete Line of HEPA Filters for Hospital, Commercial and Industrial Applications

Gaylord 30-inch Tall ELX-ND-BDL-54 Wall-Mounted Canopy Exhaust Hood Performance Report

Installation, Operation and Maintenance Manual

UNDER-FLOOR WHEEL LATHE

Leading the way for clean air in the new millennium. S o u r c e C a p t u r e

Model VSI-I & VSI-II Positive Pressure Venting Systems

ENGINEERING STANDARD STANDARD NO: PAGE 1 OF 9 DATE: 4/15/04 REVISION: 4 HEPA FILTER REQUIREMENTS

Air Purification Unit Grease, Smoke, and Odor Abatement for Commercial Kitchen Applications

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VQBL

Fumex. Upblast Roof Exhauster Technical Specifications BULLETIN FX17

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan GRAVITY VENTILATORS MGI & MGR GRV TEL & TIL LUG CATALOG 4720 MAY 2014

3.5 Exposure Control Measures

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct

J L I e x h a u s t h o o d

Gaylord Company, Model EL-ND-BDL-54 Wall-Mounted Canopy Exhaust Hood Performance Report

LOW PRESSURE MIXED FLOW FANS

XeteX, Inc. All Rights Reserved.

FOR AIR CONDITIONING AND VENTILATING APPLCATIONS

Indoor Air Quality Solutions for Machining Applications MistBuster source collection and MX-Series centralized filtration

Transcription:

ExtractAire Grease Filters for Commercial Kitchen Ventilation Hoods 50% Efficient 100% Efficient High Velocity Cartridge Multi-Stage* (HVCMS) US Patent No. 6,394,083 High Velocity Cartridge (HVC) Grease Extraction www.streivor.com 18% Efficient Baffle *Patent Pending

Commercial Kitchen Ventilation (CKV) Grease Filter Requirements Designs Extraction Efficiencies Streivor ExtractAire HVC & Baffle Filters Grease Filter Requirements CKV Hoods used for capturing and removing grease and smoke produced from commercial cooking equipment require grease filters or extractors that provide: 1. A fire barrier which limits the projection of flames downstream of the filter face. 2. Drain any collected grease from the exhaust airstream in a manner such that the grease will not fall back onto the cooking surface. Grease Filter Designs The most commonly used grease filters in CKV hoods are High Velocity Cartridge (HVC) and Baffle Filters. HVC Filters provide the ultimate in fire protection and grease extraction efficiency. HVC Filters can take on the harshest CKV environments. Baffle Filters provide reliable fire protection and grease extraction efficiency. Baffle Filters are a good choice for lighter duty CKV environments. Grease Filter Extraction Efficiencies Grease filter extraction efficiency is calculated by measuring the total percentage of grease removed by the grease filter verses the total amount of grease exhausted through the grease filter. Grease Filter Extraction Efficiency can vary greatly dependent on: 1. The design of the grease filter. 2. The size of the grease particles. Grease Particle Sizes and Categories Grease particles are measured in microns and are catagorized into three distinct groups: 1. Submicron: 0.03 to 0.55 microns, visible as smoke and other small particles. 2. Steam: 0.55 to 6.2 microns, seen as grease covered moisture and air mixtures. 3. Spatter: 6.2 to 150 microns, manifesting as larger more visible particles. The chart below shows the grease extraction efficiency curves for Streivor s ExtractAire High Velocity Cartridge Multi-Stage (HVCMS), High Velocity Cartridge (HVC), and Baffle filters. Grease Extraction Efficiency (%) 100 90 80 70 60 50 40 30 20 10 0 0.5 1 2 3 4 5 6 7 8 9 10 Particle Diameter (Microns) ExtractAire HVCMS 100 % Efficient ExtractAire HVC 50 % Efficient Baffle Filter 18 % Efficient Testing was performed by the Department of Mechanical Engineering University of Minnesota, to the ASHRAE Standard 52.2-2007. Oleic Liquid particles were used instead of KCI Solid Particles in accordance with the ASTM Standard F2519-05 since grease filters were being characterized.

Streivor ExtractAire Baffle Filter ExtractAire Baffle Filters are engineered for use in Commercial Kitchen Ventilation hoods requiring a filter that is Listed to the UL 1046 Standard. The ExtractAire Baffle Filter design and construction provides reliable fire protection and grease extraction for lighter duty CKV environments. 18 % Efficient Features / Benefits ExtractAire Baffle Filter Grease extraction efficiency: 18% @ 8 microns Round Baffle Design Aluminum Construction Stainless Steel Construction CFM per filter Provides an effective fire barrier Sightly and easy to clean Corrosion resistant Economical Corrosion resistant Added durability ExtractAire Baffle Filters are available in various sizes ranging in heights from 12 to 20 and widths from 16 to 25. The air flow characteristics for each filter size is shown in the chart below. ExtractAire TM Baffle Filter Air Flow Characteristics 1000 900 800 700 600 500 400 300 200 100 0 (*EFFECTIVE AREA) (20x25) ( *2.85) ( 16x25) (20x20) ( 16x20 ) ( * 1.73 ) ( *2.23 ) ( 12x20 ) ( * 1. 25 ) ( 12x 16) ( *0.97).25.50.75 1.00 1.25 RECOMMENDED OPERATING RANGE 200-400 FPM Static Pressure (measured in inches of H 2 O) Streivor ExtractAire Baffle Filter

Streivor ExtractAire High Velocity Cartridge (HVC) Filter Fire Barrier ExtractAire HVC Filters provide the ultimate fire barrier which prevents against a cooking fire spreading from the hood canopy into the exhaust system. Grease Extraction Process Grease laden air generated by commercial cooking equipment rises and is captured by the ventilation hood canopy. The air is then drawn into the top of the HVC Filter by an exhaust system where the air is forced around a 180º change of direction into and through a tunnel ram. The air passing through the tunnel ram accelerates by 4 times the entrance speed. At the bottom of the tunnel ram, the grease laden air is forced around a second 180 change in direction where, by means of centrifugal force and gravity, the grease particles are thrown out the open bottom of the HVC and impact with and collect in the pitched grease drip tray of the hood. Up to 50% of the grease laden air effluents larger than 8 microns are removed from the exhaust air stream by Streivor s HVC Filter. Streivor ExtractAire HVC Filter Clean Air Adjustable Air Flow Control The ExtractAire HVC Filter provides total air flow control within each individual filter. The operator can increase or decrease the airflow through each filter by simply moving the adjustable diverter choke up or down. This feature gives the installer the ability to customize the air flow into segments within a hood that contains ExtractAire HVC Filters. For example, the installer may want to increase the airflow through the filter(s) over high temperature equipment, such as broilers, or decrease air flow through the filter(s) over low temperature equipment, such as ranges. The result is the most efficient and versatile control of airflow through CKV filters ever designed. Durability Grease Removal & Collection Area Dirty Air Adjustable Choke The ExtractAire HVC is built to last indefinitely. It is constructed from heavy gauge type 304 Stainless Steel with a strong all welded body. Under normal use the HVC Filter should never need to be replaced. Choke Adjustment Positions

Streivor ExtractAire High Velocity Cartridge (HVC) Filter ExtractAire HVC Filters are engineered for use in CKV hoods requiring a filter that is Listed to the UL 1046 Standard. The ExtractAire HVC Filter design and construction provides the ultimate fire protection and grease extraction for heavy duty CKV environments. 50 % Efficient HVC Features / Benefits High Velocity Cartridge Filter Grease extraction efficiency: 50% @ 8 microns 3x more efficient than a typical baffle filter Triple Wall Construction All welded stainless steel construction provides the ultimate fire barrier Tunnel Ram Adjustable Choke Non-Loading Open Bottom Design Dishwasher Safe CFM per filter 800 750 700 650 600 550 500 450 400 350 300 250 200 US Patent No. 6,394,083 0 (*EFFECTIVE AREA) Increases the exhaust air speed inside of the filter to 4x the entrance speed Allows for airflow control within each filter Grease is not collected in the filter Allows access for thorough hand or machine cleaning Fit 3 at a time into a commercial dish wash machine HVC Air Flow Characteristics.25.50.75 1.00 1.25 1.50 RECOMMENDED OPERATING RANGE 250-1400 FPM Static Pressure (measured in inches of H 2 O) Streivor ExtractAire HVC Filter

Streivor ExtractAire High Velocity Cartridge Multi-Stage (HVCMS) Filter Streivor ExtractAire HVCMS Filter ExtractAire HVCMS Filters are engineered for use in CKV hoods requiring a filter that is Listed to the UL 1046 Standard. The ExtractAire HVCMS Filter design and construction provides the ultimate fire protection and the highest level of grease extraction available in CKV Grease Filters. ExtractAire HVCMS Filters can withstand the harshest CKV environments. The HVCMS Filter embly incorporates Streivor s sustainable, organic, replacable, and biogradable Absorb Filters. HVCMS Features / Benefits High Velocity Cartridge Multi-Stage Filter Triple Wall Construction Tunnel Ram Adjustable Choke Non-Loading Open Bottom Design Dishwasher Safe Absorb Filter* Spark Arrestor Filter** Filter Front Grease extraction efficiency: 100% @ 8 microns 5x more efficient than a baffle filter All welded stainless steel construction provides the ultimate fire barrier Increases the exhaust air speed inside of the filter to 4x the entrance speed Allows for airflow control within each filter Grease is not collected in the filter Allows access for thorough hand or machine cleaning Fit 3 at a time into a commercial dish wash machine Sustainable organic filter Easily removable, biodegradable, landfill safe Listed for use in CKV Grease Filters *May eliminate the need for a secondary pollution control unit. **Spark Arrestor Filter may be used with or without the Absorb Filter. Facilitates the code requirement for inclusion of a Spark Arrestor as part of a grease filter used in CKV hoods over solid fuel cooking equipment Removable for easy cleaning or replacement of Absorb Filter Filter Back 100 % Efficient Patent Pending

Streivor ExtractAire Absorb Filter Streivor s Absorb Filters are engineered for use in Commercial Kitchen Ventilation Hoods to capture effluents produced during commercial cooking. The Absorb Filters can capture grease particles as small as.05 microns and can achieve 100% capture and containment of grease particles 8 microns and larger. Absorb Filters are available by the case (20 filters per case) Absorb Filters are: 3 Sustainable 3 Organic 3 Replaceable 3 Biodegradable Airborne grease particles that come into contact with Streivor s Absorb Filters are absorbed and entrapped in the organic fiber. The entrapped grease particles remain in the Absorb Filter until the filter is removed and disposed. The Absorb Filters contain an antimicrobial and antibacterial agent for added health and sanitation security. The Absorb Filters are sustainable, biodegradable, and landfill safe. Removing a high percentage of the grease particulates from the exhaust air stream is extremely beneficial. Reduced emissions improve air quality and protect the environment. Reduced grease particle emissions also decreases the amount of grease buildup on the hood, ductwork, exhaust fan, and rooftop surfaces. This reduces fire hazard potentials and the amount of service and cleaning required to maintain the kitchen exhaust system. Absorb Filter* 100 % Efficient Clean Air Grease Removal & Collection Area Dirty Air CFM per filter Streivor s Absorb Filters are ETL Listed for use in CKV hoods. 800 750 700 650 600 550 500 450 400 350 300 250 200 HVCMS Air Flow Characteristics 0 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 (*EFFECTIVE AREA) RECOMMENDED OPERATING RANGE 250-1400 FPM Static Pressure (measured in inches of H 2 O) Streivor ExtractAire Absorb Filter

Streivor ExtractAire Cartridge Wash Rack Designed for Easy Cleaning The ExtractAire HVC and HVCMS Filters are easily removable for cleaning. The adjustable diverter choke is also removable, allowing total access for hand washing of both the inside and outside of the cartridge. There are no sharp edges or tight openings for fingers to become trapped or injured as in the typical baffle or other types of filters. The ExtractAire HVC and HVCMS Filters have been designed to fit into most commercial dishwashers. When the ExtractAire HVC or HVCMS filters are removed from a Streivor exhaust hood, the entire hood plenum is accessible for easy cleaning. Streivor Air Systems manufactures a heavy duty ExtractAire Cartridge Wash Rack (CWR) that fits into most commercial dish washers. The ExtractAire CWR is fabricated from 16 gauge stainless steel and 5/16 type 304 round bar. The CWR measures approximately 20 x 16 x 4. The CWR accommodates up to three 20 long ExtractAire Cartridges at one time. This protects the environment by reducing water usage, energy consumption, and the use of harmful chemicals. US Patent No. 6,394,083 www.streivor.com 1742 Sabre Street, Hayward, CA 94545 Phone: 1(888) 343-6464 Fax: (510) 670-9055 1.2014 Copyright Streivor, Inc.