HOODS AIR CHEM SYSTEMS, INC.

Similar documents
DEPAUL UNIVERSITY. Fume Hoods Manual. Environmental Health & Safety. April 2017

PVC Ductwork

VERANTIS. FRP Fans: CMHB Series Performance and Technical Information. Environmental Solutions Group

3.5 Exposure Control Measures

---:...-- Environmental Health & Safety RADIATION PROCEDURES MANUAL. Procedure Cover Sheet. Procedure Number: EHS REV 2

FRP Fans: CLUB Series Performance and Technical Information

UNIVERSITY OF ROCHESTER DESIGN STANDARDS JANUARY 2012 SECTION FUME HOODS AND LOCAL EXHAUST SYSTEMS

USER'S GUIDE TO FUME HOODS. Procedures for Increasing the Effectiveness of Laboratory Hoods. Revised December, Hood Basics

APPENDIX A. 15 DUAL WELD STATION FUME EXTRACTION with 30 WELDING BOOTHS

January, 2014 Page 1 of 6

ANATOMY DISSECTION TABLES

LABORATORY HOOD MANUAL

Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System

Model ND-2 Specification

UNR Ventilation Policy

Open Front Booths. UL & ETL listed control panel. Air solenoid valve. 5/16" bolts with serrated lock nut. Industry-leading light levels

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

RDM. Laboratory Fume Hoods SEFA SCIENTIFIC EQUIPMENT & FURNITURE ASSOCIATION

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

Proper location for Fresh Air Intake

Dust Collectors and Fume Exhausters

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

Fume Hood Program. Program originated: 08/2008 Updated: 06/2016. Gordon Krueger Environmental Safety Specialist

CORPORATION DURALAB CORPORA

Ventilated Balance Enclosures

BAC, BAF, BAH Central Station Air Handlers

ExtractAire. Grease Filters for Commercial Kitchen Ventilation Hoods. Baffle. High Velocity Cartridge (HVC)

VENT SILENCER PRODUCT GUIDE

FIBERGLASS DAMPERS FOR ODOR CONTROL AND CORROSIVE HVAC SYSTEMS

General Purpose Walk-In Fume Hood

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

Protector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector

KVR Capture Jet. KVR- Capture Jet Round Island Hood with Perimeter Jets. Round Island Hood with Perimeter Jets

Design Standard - Fume Hoods & Fume Hood Exhausts

General Purpose Walk-In Fume Hood

Vline V-LINE WITH POWER LUNG TM COMBINES LUXURY, PERFORMANCE AND VALUE. By Vent-A-Hood

General. Technical Bulletin: ACCESSORY INFORMATION

Industrial Mini Vent Sets

BMC. Laboratory Fume Hoods SEFA SCIENTIFIC EQUIPMENT & FURNITURE ASSOCIATION M E M B E R

FIBERGLASS ROUND CONTROL DAMPERS. Model K-RD INTRODUCTION M.K. PLASTICS PROVIDES FOUR DAMPER MODELS K-RD SUGGESTED SPECIFICATION

How to Use a Chemical Fume Hood Safely

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

Operating Manual SE JOHNSON CREEK BLVD. PORTLAND, OR (503) Mdf`shudOqdrrtq Negative Pressure d

Fiberglass Axial Flow Fans. Series 28 Series 28B. Series 34 Series 35 Series 35V. Series 29 Series 29B HARTZELL

Fume Hood Standard. The appropriate maintenance/engineering division on each campus or other business unit operating on UofT property shall:

Modified Downdraft Paint Booth Nut and Bolt Assembly Pre-Punched Panel Flanges

F. VAV hoods shall have a restricted bypass plate.

TABLE OF CONTENTS STANDARDS FOR THE DESIGN, CONSTRUCTION, MAINTENANCE AND USE OF LABORATORY FUME HOODS. Effective August 2010

FlameGuard. Fire Retardant FRP Duct/Pipe. FlameGuard Fiberglass Reinforced Pipe & Fittings

Completing Your Fume Removal System

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

Laboratory Fume Hood. Operation & Maintenance Manual APR 2005

TP300 INDUSTRIAL TRASH PUMP OPERATOR S MANUAL

MODELS UBB & UBX UPBLAST PROPELLER ROOF EXHAUSTERS BELT AND DIRECT DRIVE

V05 General Purpose Bench Fume Hood

Requires Ductwork and Blower

downflo workstation dust collectors

Fixed Range Exhaust Flow Canopies for NU 540 (Series 1 ), NU 543 (Series 1 ) Class II, Type A2, Biological Safety Cabinets

Viking Installation Guide

Type VSD35. Nominal length up to 1500 mm: one spigot

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)

Ductless Nanoparticle Containment Enclosures

Engineered Products. Contact an Engineered Products team member today for your special projects.

Downflo workstation DuSt ColleCtorS

OPTIMIZATION OF BUILDING VENTILATION FOR GERDAU BEAUMONT MELTSHOP USING PHYSICAL FLUID DYNAMIC MODELING*

Enclosure Drawer #8 (2) Mounting Brackets. # / (L&R) Front Mounting Brackets # / (L&R) Rear Mounting Brackets

LINEAR DIFFUSERS AND BAR GRILLES

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)

Crispin Valves Operating Guide. Crispin

SECTION DUCTWORK ACCESSORIES

MODERN-AIRE. For the professional or the everyday gourmet, Modern-Aire Ventilating. Range Hoods

GLOVE BOX GALLERY. Inert Gases. Temperature and Humidity

Protector XStream Laboratory Hoods

Lightweight protection with safety at the forefront

LABORATORY FUME HOODS OF 5

Ductless mobile fume hoods with modular filtration column

belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07

Ductless Nanoparticle Containment Enclosures

FUME HOOD SELECTION GUIDE

Product Data. Features/Benefits. WEATHERMASTER 36S Water Control Induction Air Terminals to cfm (1770 to 8900 Btuh)

SERIES COOLING TOWER. MULTI-CELL HRT COOLING CAPACITY Modular Design Crossflow Type LOW NOISE SUPER LOW NOISE ENERGY SAVING SUPER LOW NOISE

FRP VENTS. Fiberglass Reinforced Plastic Vents... No Exposed Metal Components. Distributed by Relevant Solutions relevantsolutions.

Price O.R. Systems AIR CURTAIN SYSTEM

Horizontal downflow pleated cartridge dust collector

Unit D: Agricultural Equipment Systems. Lesson 1: Understanding Applications of Fluids and Lubricants in Agricultural Equipment

Package Unit Modulating Economizer Installation Instructions

FXV/CXV & FXV3/CXV3 Layout Guidelines

CUSTOM FLOW ARCHITECTURAL SLOT DIFFUSER

MODEL TDB TUBEAXIAL INLINE BELT DRIVEN DUCT FAN

Denray Machine s Product Catalog

Cast Resin Transformers

DRUM LOUVERS DRUM LOUVERS 45DL SERIES. Models: 45DL1 Single Vanes 45DL2 Split Vanes G151 HIGH CAPACITY LONG THROW ALUMINUM CONSTRUCTION

quatroair.com AIR TECHNOLOGIES INC.

LINEAR SLOT DIFFUSERS PLENUMS

Optimizing Airflow on Dust, Mist and Fume Collection Systems

Catalog Swirl diffuser DAL 358

Proposed Amended Rule 1469 Hexavalent Chromium Emissions from Chromium Electroplating and Chromic Acid Anodizing Operations

Ducting & Ventilation Components

KVL-P with Plate Shelf

Ductless Nanoparticle Containment Enclosures

Transcription:

AIR CHEM SYSTEMS, INC. HOODS AIR CHEM SYSTEMS, INC. manufactures an extensive line of air pollution control equipment for the electronic, metal finishing, plating, sewage treatment, and other industries that generate nonflammable corrosive fumes and odors. Phone: 562-598-7100 Fax: 562-598-7115 Toll Free: 1-800-237-2865 Email: airchemsys@aol.com Web Site: www.airchemsystems.com

Ventilation Systems The Industrial Ventilation, A Manual of Recommended Practice published by the American Conference of Governmental Industrial Hygienists (ACGIH) has established hazard classifications for chemical substances used in the work environment. These classifications are known as Threshold Limit Values (TLV) and range from A-1 for very hazardous to D-4 where general room ventilation is adequate. Based on the hazard classification (TLV) and tank size and shape (aspect ratio), a ventilation rate expressed in CFM (Cubic Feet per Minute) is calculated to provide the necessary control velocities to protect personnel in the workplace. This is the first step in determining the size of the ventilation system and the hood design. ACS Hood Designs The hood is the capture device used to collect fumes being emitted from a process tank. There are three basic types of hood systems: lateral exhaust hoods, canopy hoods and enclosing hoods. The following pages discuss these three types of hood and their applications as generally found in industry. Page 2

The Lateral Exhaust Hood The lateral exhaust hood is the most common type of hood used for open process tanks. It is designed to create an evenly distributed lateral flow of air across the tank and away from the operator. There should also be a high zone of air flow to capture rising steam and vent the parts as they are raised out of the process tank. To assure proper draw, a lateral exhaust hood must be sized for the volume of air required, therefore, a specific amount of space around the tank must be allocated for the desired hood. A properly designed ventilation system must be designed at the same time as the tank line. If you have an existing line but not enough space for lateral exhaust hoods, contact AIR CHEM SYSTEMS, INC. for assistance. On large tanks where you cannot put hoods on opposite sides or where there is insufficient room for finger hoods between tanks, you can provide adequate ventilation with a push air system on the operator side of the tank, which blows fresh air toward a lateral exhaust hood at the rear of the tank.the down side of this application is that it can expose the operator to a higher risk of contamination. In processing large parts in the tank, the push air is deflected off the parts and out of the hood's capture zone toward the operator. The Canopy Hood The canopy hood is located over a tank and is used primarily for capturing steam. This hood is not practical for toxic fumes for two reasons: 1. The fumes are drawn past the operator who may be leaning over the tank. 2. A very large air volume is needed to satisfy the minimum air velocity requirements for various hazard classifications. If there are no alternatives, a possible solution is to enclose as many sides of the tank as possible thereby reducing air volume and the effect of cross drafts. Page 3

The Enclosing Hood The enclosing hood encloses the tank operation. This can be a laboratory hood, a localized tank enclosure or a total enclosure over a complete tank line. These hood systems can greatly reduce the air volume required to maintain control velocities. Page 4

1.0 MATERIALS Hood Specifications A. Resins: All hoods are fabricated using a premium grade, vinyl ester, fire-retardant resin with antimony to achieve a flame spread rating of 25 or less unless otherwise specified. B. Interior Surface: The interior surface shall have two layers of c-glass or synthetic veil to suit the chemicals the hood is being exposed to on the corrosion layer for maximum chemical resistance. C. Finish: The finish shall have a gel-coated outside finish of a commercially available resin with pigment for color. D. Fittings: All hoods shall have a 1 or larger female threaded drain fitting. E. Hardware: All hardware required to mechanically attach hoods to the tank shall be 316 stainless steel. Except for clean room applications, it is always desirable to keep the process room under negative pressure to prevent fumes from entering adjacent rooms, office spaces and/or escaping the facility. When venting large volumes of air in a facility you should consider how the air is to be replaced. Large doors and windows, poorly located in relation to the tank line, may create cross drafts at the tanks and destroy the lateral flow of the hood system. If this is the case, you can alleviate the cross draft problem by powering in up to 90% of the air vented through a return air duct system. Ideally, you should introduce this makeup air somewhere behind the operator side of the tank with sufficient diffusion to avoid blowing directly at the operator or the tanks. Consult your local air conditioning company for help in your makeup air system. Specific ACS hood types are described on the following pages. Page 5

HOF Open-Face Lateral Exhaust Hood The open-face lateral exhaust hood is the most economical type of hood for small hand dipping tanks that are generally no more than 4 feet wide and have an aspect ratio (W + L) of less than 1. The large face opening creates a high capture zone which captures more of the fumes emitted off parts as they are lifted out of the tank. Air distribution over the length of the hood is by internal slot velocity. This hood can be installed in the downdraft position for below tank duct systems. HMS Multi-Slotted Lateral Exhaust Hood The multi-slotted lateral exhaust hood allows for a much higher capture zone as the openings are divided and distributed over a much larger area of the hood face. The HMS-type hood is used for larger tanks where an automated or hand operated hoist lifts parts high out of the tank. This multi-slotted hood can also be in the downdraft configuration. Air distribution is either slot velocity or face velocity with adjustable faceplates. Page 6

HSF Single Finger Lateral Exhaust Hood The single finger lateral exhaust hood is used on large tanks with an (L) dimension of six feet or longer and the short side of the tank (W) on the operator side. This hood has a low profile allowing parts to be lifted by crane over the hood. Though this hood will adequately vent the tank, its low profile and slot opening allows fumes to escape off parts that have been lifted past the hood capture zone. It may not capture all the steam from tanks having an elevated solution temperature and high aspect ratio. On tanks wider than four feet, two hoods opposite each other are recommended. HDF Double Finger Lateral Exhaust Hood The double finger lateral exhaust hood is similar to the single finger hood but it draws air from both sides. Most tank lines will have a mixture of single and double finger hoods. One double finger hood costs less than two single finger hoods. A double finger hood can be designed to draw different ventilation rates from each side when the associated tanks have different ventilation rates. Air distribution over the length of the hood is by slot velocity and splitter veins. Page 7

HUF U-Finger Lateral Exhaust Hood The U-finger lateral exhaust hood is, basically, two single finger hoods connected by a common plenum at the rear. This type of hood is used on relatively square tanks up to four feet in either direction and where an updraft type hood cannot be used. Usually this tank is isolated and not in a tank line. This type of hood is more expensive to make than two single finger hoods connected with duct. Air distribution over the length of the hood is by slot velocity. HLE Lip Exhaust Lateral Exhaust Hood The lip exhaust lateral exhaust hood is similar to the single finger type hood except that its collection point is centered on the slot. This type of hood is used for below-tank duct systems. Two or more of these types of hoods can be mounted on the sides of long tanks for multiple take off points. This allows closer tank spacing since the plenum width will be narrower than a finger hood. Air distribution over the length of this hood is by slot velocity. Page 8

HCAN Canopy Hood The canopy hood is used primarily for steam vapor or other innocuous materials. This hood is not recommended for toxic fumes or where workers must lean over the source of toxins. HENC Enclosed Hood The enclosed hood is most often used to vent a tabletop operation or a specific tank process at a greatly reduced air flow. Because this hood is enclosed on three sides and the top it requires less air than a lateral flow hood to maintain a control velocity. A sliding sash or doors can be added to further reduce air requirements. Page 9

Tank Line Enclosure The tank line enclosure is a full enclosure over the tank line. It is custom fabricated and can be fitted with viewing windows and end doors. Page 10

Air Chem Systems, Inc. Hoist Enclosure The hoist enclosure is frequently used in conjunction with a lateral exhaust hood or tank cover. It vents only the parts as they are raised up into the enclosure. It is not intended to vent the tank as it moves from tank to tank during processing. 15222 Connector Lane Huntington Beach, CA 92649 Phone (714) 897-1017 Fax (714) 897-0639 Page 11

Manufacturer of Fiberglass Air Pollution Control & Industrial Equipment 10539 Humbolt Street Los Alamitos, CA 90720 Phone: 562-598-7100 Fax: 562-598-7115 Toll Free: 1-800-237-2865 Email: airchemsys@aol.com Web Site: www.airchemsystems.com