TECHNICAL SPECIFICATIONS

Similar documents
GR4GD Series. Single Packaged Gas/Electric Units TECHNICAL SPECIFICATIONS. GR4GD 13 SEER 2 Ton thru 5 Ton Units FEATURES AND BENEFITS

GR4GC Series Single Packaged Gas/Electric Units

GR4GA Series Single Packaged Gas/Electric Units

Q4SD Series TECHNICAL SPECIFICATIONS. Single Packaged Heat Pump, Single Phase FEATURES AND BENEFITS

R6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/Electric Units 3-5 Ton Units

R6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/ Electric Units with R-410A 3-5 Ton Units WARRANTY

TECHNICAL SPECIFICATIONS

R4GA Series TECHNICAL SPECIFICATIONS. Single Packaged Gas/Electric Units. R4GA 10 SEER 2 Ton thru 5 Ton Units FEATURES AND BENEFITS

P4SD Series Single Packaged Air Conditioning, 13 SEER 3, 4 and 5 Ton Units

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

GQ4SD Series. Single Packaged Heat Pump 13 SEER TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

GQ4 Series TECHNICAL SPECIFICATIONS. Three Phase Single Packaged Heat Pump (12 SEER) GQ4SC-036C GQ4SC-048C GQ4SC-060C FEATURES AND BENEFITS

P6SD Series Single Packaged Air Conditioning, 13 SEER - R-410A 3, 4, 5 Ton Units

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

R6GF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units Two-Stage Heat/Cool with Variable Speed Blower

GQ4SD Series. Single Packaged Heat Pump 13 SEER TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

DF6SF Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 4-Stage Heat/2-Stage Cool with Variable Speed Blower ihybrid Package Units with R-410A

TECHNICAL SPECIFICATIONS

DF6SF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units

TECHNICAL SPECIFICATIONS

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioning, 13 SEER. 3, 4, 5 Ton Units

R6GI Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Q4SE Series Single Packaged Heat Pump, Single Phase

P8SE Series. 14 SEER, Three Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY

R8HE Series Rev A. Single-Phase and Three-Phase TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

P3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800 to 48,000 Btuh

GQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS

GP4SN Series TECHNICAL SPECIFICATIONS. Single Packaged Electric Cooling Units. P4SN 10.3 EER Commercial System 7½ and 10 Ton Units

GR4GN Series TECHNICAL SPECIFICATIONS. Single Packaged Gas/Electric Units. GR4GN 10.1 EER Commercial System 7½ and 10 Ton Units FEATURES AND BENEFITS

GP5RD Series. Single Packaged Air Conditioner, Single Phase TECHNICAL SPECIFICATIONS

P5RF Series Rev "A" Single Packaged Air Conditioner Single Phase

Q7RE Series Single Packaged Heat Pump, Single Phase

P5RF Series Single Packaged Air Conditioner Single Phase

P7RF Series Two-Stage, Single Phase Packaged Air Conditioner

R6GN Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units with R-410A WARRANTY

P7RE Series Single Packaged Air Conditioner

Q5RD Series Single Packaged Heat Pump, Single Phase

Q7RE Series Single Packaged Heat Pump, Single Phase

P7RD-A Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

P7RE Series Single Packaged Air Conditioner

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

R6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

RPGE13. Product Specifications. 13 SEER Gas / Electric Residential Packaged Unit. Refrigerant System. Heat Exchanger. Cabinet Construction.

13 SEER Light Commercial 3 Phase

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

PGAA SERIES 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

RCE13. Product Specifications. 13 SEER Electric / Electric Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower.

13 SEER PACKAGE GAS / ELECTRIC UNIT (3 Phase) 35 to 53 MBtuh

CPG COMMERCIAL 5-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT

CONVERTIBLE SINGLE PACKAGE HEAT PUMP

PGB SERIES 10 SEER PRODUCT SPECIFICATIONS. Self-Contained Gas/Electric Packaged Air Conditioner

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP

14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

PGMD Series 10 SEER. International Comfort Products 651 Heil Quaker Avenue Lewisburg, Tn Part No

RPHP13. Product Specifications. 13 SEER Heat Pump Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower. Controls.

CPH COMMERCIAL 7½- TO 10-TON SELF-CONTAINED PACKAGED HEAT PUMP

CPG COMMERCIAL 4-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER

PGF / PGC SERIES CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT. PGF = Standard Models PGC = California Models with NOX baffles

GPG COMMERCIAL PRODUCT SPECIFICATIONS 13 & 10 SEER 80% AFUE 3, 4, & 5 TON, 3-PHASE SELF-CONTAINED PACKAGED GAS/ELECTRIC

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

DCG Series. Submittal Data Form. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE

PACKAGE AIR CONDITIONERS

TECHNICAL SPECIFICATIONS

13 SEER. Light Commercial 3 Phase Packaged Heat Pump. RHP13 Features and Benefits. Refrigerant System. Cabinet Construction. Blower.

14 SEER R -410A PACKAGE DUAL FUEL HEAT PUMP 2 to 5 TONS Two -Stage, Gas Heating / Electric Heating and Cooling Unit

JS5BD-KA Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

TECHNICAL SPECIFICATIONS

PHB SERIES 7-1/2 and 10 TON

PHF SERIES. THREE PHASE 50 Hz OPERATION CONVERTIBLE SINGLE PACKAGE HEAT PUMP

APD14. Packaged Dual-Fuel Units Up to 14.5 SEER 81% AFUE / 8.0 HSPF

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

CPC Series. Submittal Data Form. 15- & 20-Ton Self-Contained. Packaged Air Conditioner. with R-410A

CPG Series. Submittal Data Form. 3- to 6-Ton Self-Contained. Packaged Gas/Electric. with R-410A

TECHNICAL MANUAL *PG13 R410A

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

PHR5. Product Specifications

ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS 05.16

Transcription:

TECHNICAL SPECIFICATIONS Model PPG1GD Series M1010 Product Line Single Packaged Gas/Electric Units 13 SEER 2-5 Ton Units

10 YEAR WARRANTY WORRY-FREE PERFORMANCE 5 YEAR DEPENDABILITY PROMISE The PPG1GD Series single packaged gas/electrics are high efficiency self contained cooling units that can be installed on the roof or on a slab. The convertible unit design makes installations simple in all applications. Units are ETL and ETLc listed. The unit is truly designed with the contractor and the consumer in mind. Features and Benefits Compact Footprint/Low Profile Easy to handle and transport. Heavy-Gauge, Full Perimeter Base Rails Facilitates forklift handling and curb mounting. Convertible Air Delivery Horizontal or downflow to accommodate rooftop or horizontal application. Galvanized Steel Cabinet Unit is trimmed in a silicone-protected polyester finish with a 950 hour salt spray finish that resists corrosion 50% better than comparable units. Plastic Coated Coil Guard and Mesh Hail Guard Will never rust and protects the coil from being damaged by balls, lawnmowers, hail etc. Externally Accessible Service Ports Quick access to refrigerant system without disrupting operation. Access to Controls and Major Components Easy in and out service. Corrosion-Resistant Drain Pan Quickly drains away evaporator condensate. Smaller Panels, Great Fit and Finish, Total Seal Well-designed, quality construction. Drip edge on top panels whisks away rainwater. Embossed bottom pan keeps blower component compartment dry. Proven, Industry Standard Components Easier service and availability. Quiet Operation and Low Vibration 20 fan blade combined with custom venturi condenser fan. Accessories Roof curbs and more. SmartStart Control Board Provides extended life to ignitors using hot surface ignition technology. Programmed to learn the heatup characteristics of the ignitor, then adapt the ignition time to the characteristics of the furnace so the ignitor is energized appropriately. Low Pressure Control Loss of charge protection ensures long compressor life. Quiet Plus TM Compressor Sound Blanket Engineered to significantly reduce unwanted noise. 10 Year Residential Parts and Labor Warranty and 5 Year Dependability Promise The best warranty in the business. 2

IDENTIFICATION CODE P = Premier PG = Packaged 1 = Series SPECIFICATIONS Single Phase P PG 1 G D 24 K 072 X G = Gas D = 13 SEER X = NOx C = Standard Heating Capacity Electrical Code (000) Btu K = 208/230-60-1 Cooling Capacity (00) Btu MODEL PPG1GD -024K045(*) -024K072(*) -030K045(*) -030K072(*) -036K072(*) -036K096(*) -042K72(*) -042K96(*) -048K96(*) -48K120(*) -060K096(*) -060K120(*) Performance Heating Input Btuh 45,000 72,000 45,000 72,000 72,000 96,000 72,000 96,000 96,000 120,000 96,000 120,000 Heating Output Btuh 35,000 56,000 35,000 56,000 56,000 75,000 56,000 75,000 75,000 94,000 75,000 94,000 Capacity-Cooling Btuh 23,000 23,000 28,000 28,000 35,000 35,000 40,000 40,000 46,000 46,000 55,000 55,000 AFUE 78 78 78 78 78 78 78 78 78 78 78 78 Efficiency -- SEER 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 13.00 Efficiency -- EER 11.4 11.4 11.0 11.0 10.9 10.9 11.0 11.0 10.5 10.5 10.3 10.3 Electrical Rating - 60 Hz Phase 1 1 1 1 1 1 1 1 1 1 1 1 Operating Voltage Range 187-253 187-253 187-253 187-253 187-253 187-253 187-253 187-253 187-253 187-253 187-253 187-253 Minimum Circuit Ampacity 20.00 20.00 25 25 25.5 25.5 34.1 34.1 35.8 35.8 42.5 42.5 Max. Overcurrent Protection 30 30 40 40 40 40 50 50 50 50 70 70 Compressor Data Volts 208 / 230 208 / 230 208 / 230 208 / 230 208 / 230 208 / 230 208 / 230 208 / 230 208 / 230 208 / 230 208 / 230 208 / 230 Rated Load Amps 11.6 11.6 15.7 15.7 16 16 21.5 21.5 22.5 22.5 28.2 28.2 Lock Rotor Amps 54 54 68 68 77 77 104 104 137 137 141 141 Indoor Blower Wheel Diameter 10 x 10 10 x 10 10 x 10 10 x 10 10 x 10 10 x 10 10 x 10 10 x 10 10 x 10 10 x 10 10 x 10 10 x 10 Motor Type Fixed Torque Fixed Torque Fixed Torque Fixed Torque Fixed Torque Fixed Torque Fixed Torque Fixed Torque Fixed Torque Fixed Torque Fixed Torque Fixed Torque Motor HP 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 3/4 Motor Amps 4.1 4.1 4.1 4.1 4.1 4.1 6.0 6.0 6.0 6.0 6.0 6.0 Outdoor Fan Motor HP 1/4 1/4 1/8 1/8 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 Motor Amps 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 Fan Diameter/CFM 20" / 3500 20" / 3500 20" / 3500 20" / 3500 20" / 3500 20" / 3500 20" / 3500 20" / 3500 20" / 3500 20" / 3500 20" / 3500 20" / 3500 Refrigerant Charge (oz) 89.6 89.6 93.4 93.4 100 100 192 192 216 216 188.8 188.8 * Can be either C or X 3

DIMENSIONS To Electrical 24.9 Inside Perimeter of Base Rail 45.7 13.5 16.0 CG 13.5 16.0 2.63" 47.5 B 13.3 12.0 Downflow Supply Duct 12.0 A 23.5 Downflow Return Duct Top View Model Center of Gravity Height (in inches) Number Unit Shipping C PPG1GD Weight Weight A B with base rails without base rails 024K045 425 435 26.5 26.5 39.0 35.3 024K072 435 445 26.0 26.5 39.0 35.3 030K045 430 440 26.5 26.5 39.0 35.3 030K072 440 450 26.0 26.5 39.0 35.3 036K072 470 480 26.5 26.5 39.0 35.3 036K096 485 495 26.0 26.5 39.0 35.3 042K072 500 510 27.0 26.5 39.0 35.3 042K096 515 525 27.0 26.5 39.0 35.3 048K096 540 550 27.5 26.5 43.0 39.3 048K120 555 565 27.5 26.5 43.0 39.3 060K096 560 570 27.5 26.5 43.0 39.3 060K120 575 585 27.5 26.5 43.0 39.3 Denotes either "C" or "X" 4

DIMENSIONS continued 1.8 Electric Supply Entry Low Voltage Entry 31.0 Gas Supply Entry 24.6 16.6 2.9 47.5 4.0 Side View 1.75 Horizontal Supply Duct Horizontal Return Duct 4.0 Condensing Coil C 8.75 16.0 13.5 16.0 13.5 12.45 12.45 9.75 24.75 55.8 4.0 Back View 5

AIRFLOW DATA Model Number PPG1GD Heating Input (BTUh) 24K045( ) 45,000 35,000 30-60 24K072( ) 72,000 56,000 40-70 30K045( ) 45,000 30K072( ) 72,000 56,000 40-70 36K096( ) 96,000 Heating Output (BTUh) Heating Rise Range(F) 35,000 30-60 28,000 10 X 10 75,000 45-75 42K096( ) 96,000 75,000 45-75 48K120( ) 120,000 94,000 45-75 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise T1 845 38 735 44 625 52 540 60 453 72 335 -- 217 -- 207 -- * T2 905 36 830 39 750 43 690 47 635 51 575 56 515 -- 495 -- ** T3 950 34 880 37 810 40 755 43 705 46 655 49 600 54 570 57 T4 1110 -- 1065 30 1020 32 965 34 910 36 865 37 825 39 790 41 T5 1260 -- 1215 -- 1175 -- 1125 -- 1075 30 1030 31 990 33 960 34 T1 845 61 735 -- 625 -- 540 -- 453 -- 335 -- 217 -- 207 -- * T2 905 57 830 62 750 69 690 -- 635 -- 575 -- 515 -- 495 -- ** T3 950 55 880 59 810 64 755 69 705 -- 655 -- 600 -- 570 -- T4 1110 47 1065 49 1,020 51 965 54 910 57 865 60 825 63 790 66 T5 1260 41 1215 43 1,175 44 1125 46 1075 48 1030 50 990 52 960 54 T1 845 38 735 44 625 52 540 60 453 72 335 -- 217 -- 207 -- T2 905 36 830 39 750 43 690 47 635 51 575 56 515 -- 495 -- 23,000 10 X 10 1/2 23,000 10 X 10 1/2 ** T3 1/2 950 34 880 37 810 40 755 43 705 46 655 49 600 54 570 57 * T4 1110 -- 1065 30 1,020 32 965 34 910 36 865 37 825 39 790 41 T5 1260 -- 1215 -- 1,175 -- 1125 -- 1075 30 1030 31 990 33 960 34 T1 845 61 735 -- 625 -- 540 -- 453 -- 335 -- 217 -- 207 -- T2 905 57 830 62 750 69 690 -- 635 -- 575 -- 515 -- 495 -- ** T3 950 55 880 59 810 64 755 69 705 -- 655 -- 600 -- 570 -- 28,000 10 X 10 1/2 36K072( ) 72,000 56,000 40-70 35,000 10 X 10 1/2 * T4 1110 47 1065 49 1,020 51 965 54 910 57 865 60 825 63 790 66 T5 1260 41 1215 43 1,175 44 1125 46 1075 48 1030 50 990 52 960 54 T1 950 55 880 59 810 64 755 69 705 -- 655 -- 600 -- 570 -- T2 1110 47 1065 49 1020 51 965 54 910 57 865 60 825 63 790 66 T3 1220 43 1180 44 1135 46 1085 48 1030 50 990 52 945 55 915 57 ** T4 1260 41 1215 43 1175 44 1125 46 1075 48 1030 50 990 52 960 54 * T5 1345 -- 1300 40 1250 41 1210 43 1170 44 1120 46 1070 48 1030 50 T1 950 73 880 -- 810 -- 755 -- 705 -- 655 -- 600 -- 570 -- T2 1110 63 1065 65 1020 68 965 72 910 -- 865 -- 825 -- 790 -- T3 1220 57 1180 59 1135 61 1085 64 1030 67 990 70 945 73 915 -- ** T4 1260 55 1215 57 1175 59 1125 62 1075 65 1030 67 990 70 960 72 35,000 10 X 10 1/2 42K072( ) 72,000 56,000 40-70 40,000 10 X 10 3/4 * T5 1345 52 1300 53 1250 56 1210 57 1170 59 1120 62 1070 65 1030 67 T1 1020 51 940 55 860 60 800 65 740 70 680 -- 615 -- 570 -- T2 1185 44 1110 47 1035 50 980 53 925 56 875 59 820 63 785 66 * T3 1410 37 1330 39 1250 41 1195 43 1140 45 1085 48 1030 50 975 53 ** T4 1525 -- 1450 -- 1370 -- 1320 -- 1270 41 1210 43 1150 45 1100 47 T5 1650 -- 1585 -- 1520 -- 1465 -- 1405 -- 1340 -- 1280 41 1235 42 T1 1020 68 940 74 860 -- 800 -- 740 -- 680 -- 615 -- 570 -- T2 1185 59 1110 63 1035 67 980 -- 925 -- 875 -- 820 -- 785 -- 40,000 10 X 10 3/4 48K096( ) 96,000 75,000 45-75 46,000 10 X 10 3/4 * T3 1410 49 1330 52 1250 56 1195 58 1140 61 1085 64 1030 67 975 71 ** T4 1525 46 1450 48 1370 51 1320 53 1270 55 1210 57 1150 60 1100 63 T5 1650 -- 1585 -- 1520 46 1465 47 1405 49 1340 52 1280 54 1235 56 T1 1185 59 1110 63 1035 67 980 71 925 75 875 -- 820 -- 785 -- T2 1410 49 1330 52 1250 56 1195 58 1140 61 1085 64 1030 67 975 71 T3 1525 46 1450 48 1370 51 1320 53 1270 55 1210 57 1150 60 1100 63 * T4 1650 -- 1585 -- 1520 46 1465 47 1405 49 1340 52 1280 54 1235 56 ** T5 1775 -- 1715 -- 1650 -- 1600 -- 1540 45 1460 48 1375 51 1330 52 T1 1185 73 1110 -- 1035 -- 980 -- 925 -- 875 -- 820 -- 785 -- T2 1410 62 1330 65 1250 70 1195 73 1140 -- 1085 -- 1030 -- 975 -- T3 1525 57 1450 60 1370 64 1320 66 1270 69 1210 72 1150 -- 1100 -- 46,000 10 X 10 3/4 60K096( ) 96,000 75,000 45-75 55,000 10 X 10 3/4 60K120( ) 120,000 94,000 45-75 Cooling Output (BTUh) Motor Tap Blower Size Motor HP * T4 1650 53 1585 55 1520 57 1465 59 1405 62 1340 65 1280 68 1235 70 ** T5 1775 49 1715 51 1650 53 1600 54 1540 57 1460 60 1375 63 1330 65 T1 1185 59 1110 63 1035 67 980 71 925 75 875 -- 820 -- 785 -- T2 1525 46 1450 48 1370 51 1320 53 1270 55 1210 57 1150 60 1100 63 T3 1625 -- 1560 45 1490 47 1435 48 1380 50 1315 53 1255 55 1210 57 * T4 1725 -- 1660 -- 1600 -- 1545 45 1485 47 1415 49 1340 52 1300 53 ** T5 1775 -- 1715 -- 1650 -- 1600 -- 1540 45 1460 48 1375 51 1330 52 T1 1185 73 1110 -- 1035 -- 980 -- 925 -- 875 -- 820 -- 785 -- T2 1525 57 1450 60 1370 64 1320 66 1270 69 1210 72 1150 -- 1100 -- T3 1625 54 1560 56 1490 58 1435 61 1380 63 1315 66 1255 69 1210 72 55,000 10 X 10 3/4 External Static Pressure (Inches Water Column) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 * T4 1725 50 1660 52 1600 54 1545 56 1485 59 1415 62 1340 65 1300 67 ** T5 1775 49 1715 51 1650 53 1600 54 1540 57 1460 60 1375 63 1330 65 * Denotes Factory Set Cooling Speed ** Denotes Factory Set Heating Speed Can be C or X 6

ACCESSORIES Description Part Number Roof Curb (8 ) 547830 Roof Curb (14 ) 547831 Roof Curb (18 ) 547850 Roof Curb (24 ) 547851 Cap, Duct Adapter, 12 Round 913811A Cap, Duct Adapter, 14 Round 913812A Supply/return transition, 16 547834 Supply/return transition, 18 547835 Concentric diffuser, fl ush, 16 547836 Concentric diffuser, fl ush, 18 547837 Concentric diffuser, step down 16 547838 Concentric diffuser, step down 18 547839 Manual Fresh Air Damper 547832 Motorized Fresh Air Damper 547840 Economizer, downfl ow w/fi lter (does not require fi lter kit) modulating 547833 Economizer, horizontal modulating 547841 Economizer, horizontal 3-position w/fi lter 547896 Economizer, downfl ow 3-position w/fi lter 547897 Power Exhaust, horizontal economizer (special order) 547843 Power Exhaust, downfl ow economizer (special order) 547842 Filter Kit PPG1GD 024-042 547888 Filter Kit PPG1GD 048-060 547889 Filter Kit, All Downflow Applications (not required with economizer) 547885 Hood Type Hail Guard, Coil Dim. 34 X 76 PPG1GD-024,030,036,042 547846 Hood Type Hail Guard, Coil Dim. 38 X 76 PPG1GD-048,060 547847 CO2 sensors (special order) 547848 DUCT SMOKE DETECTOR PHOTO ELEC 547892 MULTI SIGNAL CONTROL 547893 SAMPLING TUBE ST3 547894 SAMPLING TUBE ST5 547895 Low Ambient Kit 913549A High Pressure Switch Kit 913550 Low Pressure Switch Kit 913551 Canadian LP Gas Conversion Kit (0 to 4,500 ft above sea level) 904091A U.S. LP Gas Conversion Kit (0 ft to 10,000 ft above sea level) 904090A Outdoor Thermostat Kit 913852 Universal Hard Start Kit 912933 P-Trap Kit 913810 7

CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Maytag is a registered trademark of the Maytag Corporation and is used under license. 980B-0506 (Replaces 980B-0306) Printed in U.S.A. (05/06)