RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

Similar documents
TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

INSP-3 Wiring Inspection Tester

PY-11 Voltage & Continuity Tester

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

TMA5 Mini Vane Anemometer

KMP Insulation-Continuity Tester. Users Manual

TIME-10 Process Control Stopwatch

TMULD-300 ULD-300. Ultrasonic Leak Detector. Users Manual. 99 Washington Street Melrose, MA Phone Toll Free

TACH-10 Contact / Non-Contact Tachometer

KMP7010. Ground Resistance Tester. Users Manual

362 Clamp Meter. Users Manual

Operator s Manual TC-253A. Temperature Converter

373 Clamp Meter. Users Manual

365 Detachable Jaw True-rms Clamp Meter

AMB V Insulation Resistance Tester. Users Manual. For detailed specifications and ordering info go to

THWD-3 and TH-3 Relative Humidity and Temperature Meters

323/324/325 Clamp Meter

CM100. Carbon Monoxide Meter. 99 Washington Street Melrose, MA Phone Toll Free

AC50A. Leakage Clamp Meter. User Manual. For detailed specifications and ordering info go to

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

362 Clamp Meter. Users Manual

302+/303 Clamp Meter. Users Manual

IR-500 Infrared Thermometer / Voltage Detector / Flashlight

Users Manual. Phase Rotation Indicator

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

THWD-5. Relative Humidity Temperature Meter. Users Manual. For detailed specifications and ordering info go to

TMD90A Dual Input Digital Thermometer

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

233 True-rms Remote Display Digital Multimeter Safety Information

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

i3000s/i2000 Flex AC Current Probe

i400s Calibration Information Introduction

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Visit us at

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Calibration Manual. Detachable Jaw True-rms Clamp Meter

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

Users Manual. MegOhmMeter

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

Instruction Manual ICM A1 AC/DC Clamp Meter ICM A1

716 Pressure Calibrator

CO2-100 CO2 Meter. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

712 RTD Calibrator. Instruction Sheet. Introduction


Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card.

User Guide. Model Insulation Tester / Megohmmeter. Introduction

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

OPERATING INSTRUCTIONS

719 Series. Pressure Calibrator with Electric Pump. Product Overview (E)

Instruction Manual. Model 307A Analog Insulation & Continuity Meter

718 30G/100G. Users Manual. Pressure Calibrator. 99 Washington Street Melrose, MA Phone Toll Free

ANALOGUE INSULATION-CONTINUITY and VOLTAGE METER

Go to to register your product and find more information.

90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

Dawson DDM190D. Digital Multimeter User s Manual

PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL

80 Series V Digital Multimeter Safety Information

R&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual

Low Amp Probe EETA308A

5.2 PRE-OPERATION PROCEDURE WARRANTY

OPERATING INSTRUCTIONS

717 Series. Pressure Calibrators. Instruction Sheet. Introduction

Infrared Thermocouple Probe

OPERATING INSTRUCTIONS

Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

Digital/Analog Megohmmeter Model 1026

BK BK J93 MA BK MA BK MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

Switching DC Power Supply

1 INTRODUCTION SPECIFICATIONS Electrical Data General Data... 3

Dawson DAN100. Analog Multimeter User s Manual

CP GermanCp 41_CP C. Operating Instructions. CP 30 CP 330 CP 1100 AC/DC current probe /7.10

For technical questions and replacement parts, please call

AC/DC CURRENT TRANSDUCER INSTRUCTION MANUAL

Autoranging Multimeter

1000FLT. Users Manual. Fluorescent Light Tester

707Ex. Users Manual. ma Calibrator

SLA Battery Capacity Analyzer

Users Manual. Airflow Meter

DC REGULATED POWER SUPPLY

Model 1693, 1694 Switching DC Power Supply

True RMS Autoranging Multimeter

27 II/28 II. Digital Multimeters. Getting Started Manual. Specifications

DC POWER SUPPLY ALIMENTATION C.C.

Table of Contents Title Page No.

BK BK A BK MA BK MA BK J93 MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

Digital/Analog Megohmmeter Model 1026 USER MANUAL

Transcription:

RS-3 PRO RS-1007 PRO CAT IV Analog Clamp meter Series Users Manual For detailed specifications and ordering info go to www.testequipmentdepot.com

RS-3 PRO RS-1007 PRO CAT IV Analog Clampmeter Series English Users Manual RS3RS1007_Rev001 2009 Amprobe Test Tools. All rights reserved. 1

Limited Warranty and Limitation of Liability Your Amprobe product will be free from defects in material and workmanship for 1 year from the date of purchase. This warranty does not cover fuses, disposable batteries or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Amprobe s warranty obligation is limited, at Amprobe s option, to refund of the purchase price, free of charge repair, or replacement of a defective product. Resellers are not authorized to extend any other warranty on Amprobe s behalf. To obtain service during the warranty period, return the product with proof of purchase to an authorized Amprobe Test Tools Service Center or to an Amprobe dealer or distributor. See Repair Section for details. This warranty is your only remedy. All other warranties - whether express, implied or statutory - including implied warranties of fitness for a particular purpose or merchantability, are hereby excluded. Neither Amprobe nor its parent company or affiliates shall be liable for any special, indirect, incidental or consequential damages or losses, arising from any cause or theory. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you. Repair All test tools returned for warranty or non-warranty repair or for calibration should be accompanied by the following: your name, company s name, address, telephone number, and proof of purchase. Additionally, please include a brief description of the problem or the service requested and include the test leads with the meter. Non-warranty repair or replacement charges should be remitted in the form of a check, a money order, credit card with expiration date, or a purchase order made payable to Amprobe Test Tools. In-Warranty Repairs and Replacement All Countries Please read the warranty statement and check your battery before requesting repair. During the warranty period any defective test tool can be returned to your Amprobe Test Tools distributor for an exchange for the same or like product. Non-Warranty Repairs and Replacement US and Canada Non-warranty repairs in the United States and Canada should be sent to a Amprobe Test Tools Service Center. Call Amprobe Test Tools or inquire at your point of purchase for current repair and replacement rates. 2

1 2 Analog Clamp Meter Analog Clamp Meter NEEDLE LOCK 3 NEEDLE LOCK AMP 4 AMP 100 100 V A 80 V A 80 60 5 60 40 40 20 20 e ZERO 0 6 e ZERO 0 CAT IV 600V COM Ve W X MAX 600V B J 7 CAT IV 600V COM Ve W X MAX 600V B J RS-3 PRO RS-1007 PRO ➊ Current jaws ➋ Jaw opening lever ➌ Function / Range selector wheel ➍ Needle Lock ➎ Volt Amp needle - zero adjust, Ohms - adjust ➏ (On side) Ohms zero adjust ➐ Input jacks for Volts and Ohms 3

RS-3 PRO / RS-1007 PRO CAT IV Analog Clampmeter Series Contents Symbols...5 Safety Information...5 Warnings and Precautions...5 Unpacking and Contents...6 Introduction...6 Operation...6 Measuring AC Voltage (See Fig. 1)...6 AC Current Measurement (See Fig. 2)...6 Measuring Resistance /Continuity (See Fig. 3)...6 Maintenance and Repair...6 Battery Replacement (see Fig. 4)...7 Fuse Replacement...7 Specifications...7 4

Symbols Battery Refer to the manual Double insulated Dangerous Voltage Alternating Current Earth Ground Conforms to relevant Australian standards. Do not dispose of this product as unsorted municipal waste. Complies with EU directives Underwriters Laboratories.[Note: Canadian and US.] Application around and removal from hazardous live conductors is permitted Safety Information The RS-1007 Pro and RS-3 Pro Analog Clamp meters conform to EN61010-1:2001; EN61010-2-032:2002; CAT IV 600 V, class II and pollution deg.2 This instrument is EN61010-1 certified for Installation Category IV (600V). It is recommended for use in primary supply lines, overhead lines and cable systems and distribution level and fixed installations, as well as lesser installations. Do not exceed the maximum overload limits per function (see specifications) nor the limits marked on the instrument itself. Never apply more than 600 V ac rms between the test lead and earth ground. Warnings and Precautions Before and after hazardous voltage measurements, test the voltage function on a known source such as line voltage to determine proper meter functioning. Disconnect the test leads from the test points before changing meter functions. Disconnected from the meter s test leads before measuring current. Inspect the Clampmeter, test leads and accessories before every use. Do not use any damaged part. Never ground yourself when taking measurements. Do not touch exposed circuit elements or test probe tips. Do not operate the instrument in an explosive atmosphere. To reduce the risk of fire or electric shock, do not expose this product to rain or moisture. The meter is intended only for indoor use. To avoid electrical shock hazard, observe the proper safety precautions when working with voltages above 60 VDC, 42.4 Vpk, or 30 VAC rms. These voltage levels pose a potential shock hazard to the user. Before and after hazardous voltage measurements, test the voltage function on a known source such as line voltage to determine proper meter functioning. Keep your hands/fingers behind the hand/finger barriers (of the meter and the test leads) that indicate the limits of safe access of the hand-held part during measurement. Inspect test leads, connectors, and probes for damaged insulation or exposed metal before using the instrument. If any defects are found, replace them immediately. This Clamp-on meter is designed to apply around or remove from uninsulated hazardous live conductors. Individual protective equipment must be used if hazardous live parts of the installation could be accessible. Exercise extreme caution when: measuring voltage >20 V // current >10 ma // AC power line with inductive loads // AC power line during electrical storms // current, when the fuse blows in a circuit with open circuit voltage >1000 V // servicing CRT equipment. Remove test leads before opening the case to change the battery. CAUTION For non-invasive ACA current measurements, clamp the jaws around only one single conductor of a circuit for load current measurement. More than 1 conductor will cause false readings. CAUTION Verify the needle lock is released before making measurements. 5

Unpacking and Contents Your shipping carton should include: 1 RS-1007 Pro or RS-3 Pro 1 Test lead set 1 1.5V AAA battery (installed) 1 F 0.5 A 1000V Fuse (installed) 1 Users Manual 1 Carrying Case If any of the items are damaged or missing, immediately return the complete package to the place of purchase for an exchange. Introduction The RS-1007 Pro and RS-3 Pro Analog Clamp-On meters are manual ranging 1000 / 600 ACA and 600 V clamp meter. The features include AC voltage, AC current, and Resistance test ranges. Both clampmeters have a mechanical needle clamp to prevent needle damage during transportation. Operation Measuring AC Voltage (See Fig. 1) CAUTION Remove clamp jaws from wire before connecting to or measuring voltage. 1. Rotate the meter scale wheel to appropriate V range. 2. Using the V A Zero screw (front panel), adjust the needle for 0. 3. Connect the test leads: Red to + and Black to COM. 4. Connect the test probes to the circuit test points. 5. Read the needle location on the meter scale and, if necessary, correct any overload (needle pegged) conditions. AC Current Measurement (See Fig. 2) CAUTION Disconnect test leads from circuit and meter if voltage was being tested. 1. Rotate the meter scale wheel to appropriate A range. 2. Using the V A Zero screw (front panel), adjust the needle for 0. 3. Open spring-loaded clamp by pressing the lever on left side of meter. 4. Position clamp around one wire or conductor and release the clamp lever. 5. Read the needle location on the meter scale, and, if necessary, correct any overload (needle pegged) conditions. CAUTION Using Resistance or Continuity function in a live circuit will produce false results and may damage the instrument. In most cases the suspected component must be disconnected from the circuit to obtain an accurate measurement reading. Measuring Resistance /Continuity (See Fig. 3) 1. Rotate the meter scale wheel to Ω range. 2. Turn off power to the circuit being measured and discharge any capacitors in the circuit. 3. Connect the test leads: Red to + and Black to COM. 4. Short the test leads and adjust Ω Zero knob for 0 Ω. 5. Remove the short from the test leads. 6. Using the V A Zero screw, adjust the needle for. 7. Connect the test probes across the resistance. 8. Read the needle location on the meter scale, and, if necessary, correct any overload (needle pegged) conditions. Maintenance and Repair If there appears to be a malfunction during the operation of the meter, the following steps should be performed in order to isolate the cause of the problem: 1. Verify the needle lock is disengaged (all the way to the left). Needle should move when meter is moved. 2. Check the battery and fuse (ohms range only). 3. Review the operating instructions for possible mistakes in operating procedure. 4. Inspect and test the test leads for a broken or intermittent connection. Except for the replacement of the fuse, battery or test probes, repair of the multimeter should be performed only by a Factory Authorized Service Center 6

or by other qualified instrument service personnel. The front panel and case can be cleaned with a mild solution of detergent and water. Apply sparingly with a soft cloth and allow to dry completely before using. Do not use aromatic hydrocarbons or chlorinated solvents for cleaning. Battery Replacement (see Fig. 4) Warning To prevent electrical shock or meter damage, disconnect the meter s test leads from any circuit and the meter, then turn the meter off before removing the battery cover. Battery replacement should be performed in a clean environment and with appropriate care taken to avoid contaminating the meter s interior components. 1. Remove the screw and lift the battery cover. 2. Remove the battery using the pull strap. 3. Replace the battery with the same type, 1.5 V AAA battery (NEDA-24A, IEC LR03). Note polarity of the battery. 4. Replace the battery cover and screw. Fuse Replacement 1. Remove the screw and lift the battery cover. 2. Remove the battery using the pull strap. 3. Remove the fuse using the pull strap. 4. Replace the fuse with F 0.5 A Fuse (FP500) 5. Replace the battery noting the polarity of the battery. 6. Replace the battery cover and screw. Specifications General Display: Analog scales with clamping needle Power Supply: Volts / amps: powered by circuit under test Ohms: 1.5 V AAA battery (ANSI/NEDA-24A, IEC LR03) Low Battery: Below approx. 1.2 V Environmental: Indoor operation; below 2000m (6,562ft) Operating Temperature : -15 C to 50 C (5 F to 122 F) ; < 80% Storage Temperature: -20ºC to 60ºC (-4ºF to 140ºF), < 80% R.H. (with battery removed) Temperature Coefficient: nominal 0.15 x (specified accuracy)/ºc @ 0ºC to 18ºC or 28ºC to 40ºC (32 F to 64 F or 82 F to 104 F) Dimension: RS-1007 Pro: 261 x 102 x 41 mm (10.3 x 4.0 x 1.6 in.) RS-3 Pro: 243 x 102 x 41 mm (10.3 x 4.0 x 1.6 in.) Weight: RS-1007 Pro: 0.474 kg (1.05 lb.) RS-3 Pro: 0.455 kg (1.0 lb.) Jaw opening / Conductor diameter: RS-1007 PRO: 47mm (1.88") max RS-3 PRO: 41mm (1.64") max Safety LVD: Meets EN60101-1:2001; EN61010-2-032(2002), Category IV - 600 Volts ac; pollution degree : II; class 2 EMC: EN 61326-1:2006 This product complies with requirements of the following European Community Directives: 2004/108/EC (Electromagnetic Compatibility) and 2006/95/EC (Low Voltage) as amended by 93/68/EEC (CE Marking). However, electrical noise or intense electromagnetic fields in the vicinity of the equipment may disturb the measurement circuit. Measuring instruments will also respond to unwanted signals that may be present within the measurement circuit. Users should exercise care and take appropriate precautions to avoid misleading results when making measurements in the presence of electronic interference. Electrical 23ºC ± 5ºC (73ºF ± 9ºF) <75%RH AC Voltage (50/60 Hz) Ranges: 150 / 300 / 600 Vrms Accuracy: ± 3% of Full Scale. Input Impedance: 1.5 MΩ 7

OL Protection: 600 V ac rms AC Amp (50/60 Hz) Ranges: RS-1007 Pro: 15 / 40 / 100 / 300 / 1000 Arms RS-3 Pro: 6 / 15 / 40 / 100 /600 Arms Accuracy: ± 3 % of Full Scale Ohms Range: 1000 ohms 25 Ohms mid-scale Accuracy: ± 3 degrees of Arc Open Circuit voltage: 1.5v Short circuit Current: 58 ma OL Protection: (F 0.5 A / 1000 V, size 6 x 32 mm IR fast blow ceramic) 8

B Analog Clamp Meter NEEDLE LOCK VOLT 150 V A 125 100 75 50 20 e ZERO 0 CAT IV 600V COM Ve W X MAX 600V B J Fig 1. Volts Analog Clamp Meter NEEDLE LOCK AMP 100 V A 80 60 40 20 e ZERO 0 CAT IV 600V COM Ve W X MAX 600V B J Fig 2. Amps 9

Analog Clamp Meter NEEDLE LOCK Ω 0 V A 5 10 20 50 100 200 e ZERO 500 1k CAT IV 600V COM Ve W X MAX 600V B J Fig 3. Ohms + 1.5 V AAA F 0.5A 1000V Fig. 4 Battery Fuse 10