Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Similar documents
Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

Features, Benefits and Functions

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

SWITCHGEAR DIVISION PRODUCT PROFILES

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Unit Substation Transformers 5 and 15 KV Class

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Medium Voltage Equipment 5-15 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

Detail Bill of Material Page 1 of 1 Project Name: Amphi School - MVS Replacement Negotiation No: TU700213X7K2 General Order

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

Chapter 6 Generator-Voltage System

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Unitole UP kv Primary substations Motor control centres

Solar Power Switchgear & Energy Storage Renewable Energy Systems

Unitole UP kv Primary substations Motor control centres

Submersible Vacuum Fault Interrupters

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin

45 kva Isolation Transformer - 480V Delta Primary - 400V Delta Secondary - N3R - Copper Windings

Descriptive bulletin. ReliaGear ND ANSI narrow frame metal-clad switchgear

Three-Phase Ventilated

Overview Brochure Integrated Power Distribution. Medium Voltage Assembly Solutions

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

Tradition. Technology. Innovation.

Class I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

Horizontal Circuit Switchers

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

A. This section includes unit capacitors for power factor correction.

University of Houston Master Construction Specifications Insert Project Name

SafeGear TM Motor Control Center Arc resistant metal-clad construction

BUSWAY Low Voltage (Pow-R-Flex)

Single-Phase Ventilated

www. ElectricalPartManuals. com lncoming-6900 through 69,000 volts Outgoing-2400 through 13,800 volts Ratings:

SIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC

Totally Enclosed Non-Ventilated

A comparison of metal-enclosed load interrupter (ME) switchgear and metal-clad (MC) switchgear

C1000 Series Automatic Cap Bank

POWERCON CORPORATION

30kVA Transformer - 3 Phase Delta Primary - 380Y/220 or 400Y/230 Secondary - NEMA 3R

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

Contents. Page INTRODUCTION Power/Vac GUIDE FORM SPECIFICATION thru

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

Switchgear. Low Voltage

Pretest Module 29 High Voltage Unit 1

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

Dry-Type Transformers Mini-Power Centers

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

7. SERVICES OVER 600 VOLTS

Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear. ABB Group February 25, 2015 Slide 1

16.13 Unit Substation to 15kV Construction Standards Page 1 of 7

www. ElectricalPartManuals. com

SIMOVAC and SIMOVAC-AR. Medium-voltage controllers 2.3 kv kv. usa.siemens.com/simovac

SECTION PANELBOARDS

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!

ATLV MaxSG. Low Voltage Metal Enclosed Switchgear

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

75 kva Transformer - 480V Delta Primary - 208Y/120 Wye-N Secondary - NEMA 3R - K-13 - Copper Winding

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

Horizontal Circuit Switchers

Electrical Switchgear Replacement Montgomery County Community College

DRIESCHER Y WITTJOHANN, S.A. MEDIUM VOLTAGE SOLUTIONS

POWERCON CORPORATION

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

A. This section includes enclosed dry type transformers for lighting and power loads, with primaries and secondaries rated 600 volts and less.

Midwest Dry Type Transformers

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

Innovac SVS/08 - SVS/ kv modular switchgear

SECTION MOTOR STARTERS (AMPGARD) MEDIUM VOLTAGE

.1 Low Voltage Switchgear Magnum DS Switchgear with Molded Case Circuit Breaker Feeder Section Cross-Reference Eaton s Electrical Sector has an organi

1500 kva Pad Mount Transformer GRDY/14400V Primary - 208Y/120 Wye Secondary - Oil Cooled

Gas Insulated Metal-clad Switchgear, HMGS!

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Unit

WLI Medium Voltage Switchgear Renewal Parts

GE Energy Connections Industrial Solutions. DET-882 Application and Technical Guide. SecoGear

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

Critical Power Switchboards. Selection and Application Guide

Extensible Unit - VCE2a

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage

Metal-enclosed medium-voltage power factor correction system

BGE STRATEGIC CUSTOMER ENGINEERING

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

SECTION ELECTRIC DISTRIBUTION

Customer Substation Manual

Transcription:

January 2003 Vol. 1, Ref. No. [1011] -1 Medium Voltage Metal-Enclosed Switches Contents Description Page MVS................................... -2 and Breaker MSB........................ -3 Metal-Enclosed Breaker MEB................................... -4 Unitized Power Centers UPC.................................... -5 OEM Component MVS-C.................. -6 00000 MVS

-2 January 2003 MVS Vol. 1, Ref. No. [1012] MVS MVS Cutler-Hammer MVS switchgear by Eaton Corporation is available in one or more vertical section assemblies to provide safe, low-cost switching and circuit protection where occasional or infrequent disconnecting means is desired. The three-pole switch will interrupt its rated load current with its quick-make, quick-break mechanism. Optional fuses ensure short circuit protection at all times. De-ion Arc Interruption: De-ion Arc chambers and spring loaded auxiliary blades ensure fast load current interruption and eliminate arcing damage to the main contacts. Positive Switch Position Indication: Red and Green multilingual (English/ Spanish/French) labels located directly on the switch operating mechanism gives visual indication of switch position. Interlocked for Safety: Mechanical interlocks prevent closing the switch when the compartment door is open, or the opening of the door when the switch is closed. Safety Under Fault Conditions: The switch, depending upon the rated voltage, is available with three or four fault-closing operations with ratings up to 61,000 amperes rms asymmetrical exceeding the industry standards one time operation. See Descriptive Bulletin 31-935 for the available ratings. Safety Barrier: A hinged solid metal barrier with a perforated metal viewing area shields the disconnect switch when the compartment door is opened. Short Circuit Protection: A full range of Eaton s Cutler-Hammer fusing options is available for short circuit protection. MVS switchgear meets or exceeds IEEE C37.20.3 and NEMA SG-5 as they apply to metal-enclosed switchgear. Either Underwriters Laboratories or Canadian Standards Association listing is available for MVS switchgear in many configurations, with a number of options. MVS switchgear is available seismically qualified to meet the requirements of the Uniform Building Code, California Title 24 and IBOCA requirements in many configurations with a number of options. Rated maximum voltage classes, kv: 5, 15, 27, 38. Rated impulse levels, kv BIL: 60, 95, 125, 150. Continuous and load-break ratings: 600 amperes available at all voltage classes, 1200 amperes available at 5 kv and 15 kv. Designs available in indoor and outdoor non-walk-in configurations. MVS switchgear can be applied for many switching duties whether manual, motor operated or automatic operation is specified: Inspection Window De-ion Arc Interrupters Transformer primary switching. Transformer secondary switching. Power distribution switching. Switch Drive Mechanism Interlock Quick-Make, Quick-Break Mechanism: A reliable heavy-duty coil spring mechanism drives the switch blades at high speed into either the open or the closed position. The speed of operation is independent of the person operating the switch. Direct Drive Mechanism: A metal-tometal direct drive mechanism eliminates chains or cables that may break or need adjusting. Operating Handle (Mounted in Access Door) MVS Fuses High Dielectric Insulation (Also Used Between Switch Phases and Ground) Descriptive Bulletin.............. 31-930C Price List....................... 31-930 Guide, 13th Edition............... CA08104001E Renewal Parts Catalog........... 26-000

January 2003 Vol. 1, Ref. No. [1013] MSB -3 and Breaker MSB Cutler-Hammer MSB switchgear by Eaton Corporation is an integrated assembly of a visible load break disconnect switch, fixed mounted vacuum circuit breaker, and control devices which are integrated electrically and mechanically for circuit protection. All major components are manufactured by Eaton s Cutler- Hammer, establishing one source of responsibility for the equipment and assuring high standards in quality, coordination, reliability and service. MSB switchgear would typically be used where both cost and protection are important design parameters. Excellent applications would include ground fault protection, primary and/ or secondary switching and protection on unit substations, automatic transfer switching at medium voltage levels, capacitor switching, frequent operation, and tight system coordination protection. Eaton s Cutler-Hammer Medium Voltage Vacuum Breaker (MSB) switchgear provides economic and reliable circuit switching and fault protection for medium voltage circuits of 4.76 kv, 15 kv and 27 kv. MSB is ideal for applications where load interrupter switches should not be applied, such as ground fault protection, high duty cycle applications, or high speed automatic transfers. It is also a better engineering alternative than load interrupter switches for applications involving shunt tripping, single-phase protection, capacitor switching, and ground protection. MSB switchgear can also be an economic benefit in single-ended substations since it may allow the customer to eliminate the secondary main protection and switching device. Visible isolation. Fully rated vacuum circuit breaker. Electrical operation. No fuses. Improved coordination capability. Improved transformer protection. Ground fault protection. Capacitor switching. High switching duty cycling. MSB switchgear meets or exceeds IEEE C37.20.3 and NEMA SG-5 as they apply to metal-enclosed switchgear. Either Underwriters Laboratories or Canadian Standards Association listing is available for MSB switchgear in many configurations with a number of options. MSB switchgear is available seismically qualified to meet the requirements of the Uniform Building Code, California Title 24 and IBOCA requirements in many configurations with a number of options. and Breaker MSB Rated maximum voltages of 4.76, 15 and 27 kv. Continuous current ratings of 600 and 1200 amperes. 25 ka rms symmetrical short circuit interrupting capacity. Designs available in indoor and outdoor non-walk-in configurations. Single vertical section and transformer primary configurations. Lineups consisting of MSB and MVS vertical sections. Descriptive Bulletin.............. 31-930C Price List........................ 31-930 Guide, 13th Edition............... CA08104001E Renewal Parts Catalog........... 26-000

-4 January 2003 MEB Vol. 1, Ref. No. [1014] Metal-Enclosed Breaker MEB Cutler-Hammer MEB switchgear by Eaton Corporation is a metal-enclosed assembly of single high drawout VCP-W vacuum circuit breakers and control devices that are integrated electrically for circuit protection. (For drawout vacuum breaker metal-clad switchgear, type VacClad-W, see Section 22.) All major components are manufactured by Eaton s Cutler-Hammer, establishing one source of responsibility for the equipment and ensuring high standards in quality, coordination, reliability and service. MEB switchgear would typically be used where both cost and protection are important design parameters. It can be applied as the primary main device and integrated with fused feeder switches in a lineup of fused MVS switchgear. Eaton s Cutler-Hammer Metal-Enclosed Vacuum Breaker (MEB) switchgear provides economic and reliable circuit switching and fault protection for medium voltage circuits of 4.76 kv and 15 kv. MEB is ideal for applications where load interrupter switches should not be applied, such as ground fault protection, high duty cycle applications, or high speed automatic transfers. It is also a better engineering alternative than load interrupter switches for applications involving shunt tripping, single-phase protection, capacitor switching, and ground protection. MEB switchgear can also be an economic benefit in single-ended substations since it may allow the customer to eliminate the secondary main protection and switching device. Fully rated vacuum circuit breaker. Electrical operation. Improved coordination capability. Improved transformer protection. Ground fault protection. Capacitor switching. High switching duty cycling. MEB switchgear meets or exceeds IEEE C37.20.3 and NEMA SG-5 as they apply to metal-enclosed switchgear. Either Underwriters Laboratories or Canadian Standards Association listing is available for MEB switchgear in many configurations with a number of options. MEB switchgear is available seismically qualified to meet the requirements of the Uniform Building Code, California Title 24 and IBOCA requirements in many configurations with a number of options. Metal-Enclosed Vacuum Breaker MEB Rated maximum voltages of 4.76 and 15 kv. Continuous current rating of 1200 amperes. Short circuit current ratings up to 38 ka rms symmetrical. Designs available in indoor and outdoor non-walk-in configurations. Single vertical section and transformer primary configurations. Lineups consisting of MEB vertical sections and MVS vertical sections. Descriptive Bulletin............... 31-960 Price List........................ 31-930 Guide, 13th Edition................ CA08104001E Renewal Parts Catalog............ 26-000

January 2003 Vol. 1, Ref. No. [1015] UPC -5 Unitized Power Centers Unitized Power Center Cutler-Hammer Unitized Power Centers by Eaton Corporation combine a MVS primary disconnect switch, a ventilated dry-type transformer, and Pow-R-Line 4 secondary distribution devices in a compact, factory assembled integral unit. These selfcontained units provide maximum kva in minimum space, and their one-piece construction simplifies installation. Other advantages include: Front accessibility. Against-the-wall mounting. Dimensions consistent with standard doorways. Liberal space for primary and secondary cables. Molded case circuit breaker or fusible switch secondary distribution. Benefits, Features Components The Primary Disconnect Switch is a manually operated, two-position, quick-make, quick-break type MVS. Distribution class surge arresters protect the transformer from surge voltages and when specified current limiting fuses protect against fault currents. Insulated cable passes through a steel barrier to connect the switch to the transformer. The Power Transformer is of a ventilated, dry-type, core-form construction. Standard Class 220 C insulation allows normal operation at 150 C temperature rise above a 30 C nominal ambient and a 40 C peak ambient. Core and coil assemblies meet all applicable IEEE/ANSI/NEMA standards. The Secondary Distribution Section consists of group mounted Series C molded case circuit breakers or FDP-W fusible switches separated from the transformer by steel barriering. Additional vertical sections may be added for additional low voltage distribution. Power Center Ratings Maximum primary voltages: 3 kv through 15 kv 3-phase, 60 Hz, Delta primary Primary BIL: Voltages not exceeding 2.5 kv maximum 20 kv BIL Voltages above 2.5 kv up to 7.2 kv maximum 30 kv BIL Voltages above 7.2 kv up to 15 kv maximum 60 kv BIL Transformer: kva: 112.5 1000 Winding material, copper type, ventilated dry Insulation: Class H 220 C rise (standard) 150 C, 115ºC and 80 C rise available Fan cooling available to increase kva rating by 33 1 / 3 % Taps: ±(2) 2.5% FCAN and FCBN Secondary voltages: 208Y/120 volts 4-wire 240 volts 3-wire 480Y/277 volts 4-wire 575 volts 4-wire Secondary BIL: 10 kv BIL. Guide, 13th Edition............... CA08104001E

-6 January 2003 MVS-C, Vol. 1, Ref. No. [1016] OEM Fusible Switches MVS-C Switch MVS-C Fuse Mounting MVS-C switches are open frame switches that must be mounted in a suitable enclosure for the OEM market. Cutler-Hammer MVS-C load interrupter switches by Eaton Corporation are available in many ratings. When properly applied, they will provide safe, low-cost switching where occasional or infrequent disconnecting means is desired. The three-pole switch, with its quick-make, quickbreak mechanism, will interrupt its rated load current. MVS-C switches can be applied in suitable enclosures for many switching duties whether manual or automatic operation is specified: Transformer primary switching. Transformer secondary switching. Power distribution switching. Plug & Play: The switch and operating mechanism installs as a single entity. No handle and chains or cables to mount and adjust. Improves productivity in assembly reducing overall cost. Quick-Make, Quick-Break Mechanism: A reliable heavy-duty coil spring mechanism drives the switch blades at high speed into either the open or the closed position. De-ion Arc Interruption: De-ion Arc chambers and spring loaded auxiliary blades ensure safe, fast load current interruption and eliminate arcing damage to the main contacts. Positive Switch Position Indication: Red and Green multilingual (English/ Spanish/French) labels located directly to the switch operating mechanism gives visual indication of switch position. Interlocked for Safety: When properly installed to utilize the built-in design feature, mechanical interlocks prevent closing the switch when the enclosure door is open, or the opening of the door when the switch is closed. As an alternate interlock method, key interlock provisions are included. Safety Under Fault Conditions: The switch, depending upon the rated voltage, is available with three or four fault-closing operations with ratings up to 61,000 amperes rms asymmetrical exceeding the industry standards one-time operation. See PL 31-931 for available ratings. Fuse Mountings: Complete threephase fuse mounting assemblies or fuse live parts are available that are fully compatible with MVS-C switches. The fuse mountings are intended for use with Eaton s Cutler-Hammer fuses. Direct Drive Mechanism: A metalto-metal direct drive mechanism eliminates chains or cables that need adjusting or break. MVS-C switches meet or exceed ANSI C37.22 ratings. Underwriters Laboratories and Canadian Standards Association recognized component listing service is available for 5 and 15 kv manual and motor operated MVS-C switches. Rated maximum voltage classes, kv: 5, 15, 27, 38. Rated impulse levels, kv BIL: 60, 95, 125, 150. Continuous and load-break ratings: 600 amperes available at all voltage classes, 1200 amperes available at 5 kv and 15 kv. Price List.............................. 31-931 Renewal Parts Catalog.................. 26-000