INSTALLATION INSTRUCTIONS

Similar documents
INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS

CRECOMZR054B00 CRECOMZR055B00. VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS WARNING TABLE OF CONTENTS

ECONOMIZERS. 5/2012 Supersedes

Package Unit Modulating Economizer Installation Instructions

INSTALLATION INSTRUCTION

Package Unit Modulating Economizer Installation Instructions

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard C**H Series 2 & 2½ Ton 2-Stage Wall Mount Heat Pumps

LXIPEB33 505,038M MARCH 14, 2012 SUPERCEDES

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard CH Series 3, 4, & 5 Ton Wall Mount Heat Pumps

IMPORTANT ATTENTION INSTALLERS:

DTC Series. Submittal Data Form 3- TO 5-TON SINGLE-PHASE PACKAGED AIR CONDITIONER

ECONOMIZERS. 1/2012 Supersedes

RANGER 900 POWER STEERING KIT

Installation Instructions

Blank-off. HVAC unit screws. Spacer for 1" filter ILL. 3. Screw

ACCESSORY KIT INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard 2 2-1/2 Ton Wall Mount T Series Heat Pumps

CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

EconoMi$er, Power Exhaust, and Sensor Installation Instructions

COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2014 Supersedes 8/2012

CPC Series. Submittal Data Form. 15- & 20-Ton Self-Contained. Packaged Air Conditioner. with R-410A

Installation Instructions

Installation Instructions

Library Product Section Product Model Literature Type Sequence Date File No. Supersedes

Model 8144NC Fresh Air Ventilator

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Instructions for Field Retrofit of a Model 98 Temperature Controller in place of a Model 85 Temperature Controller

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

RCE13. Product Specifications. 13 SEER Electric / Electric Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower.

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Installation Instructions

RPHP13. Product Specifications. 13 SEER Heat Pump Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower. Controls.

INSTALLATION INSTRUCTIONS ISLAND LINER INSERT

13 SEER Light Commercial 3 Phase

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

2SA13 60HZ P A C K A G E D E L E C T R I C / E L E C T R I C

CPG Series. Submittal Data Form. 3- to 6-Ton Self-Contained. Packaged Gas/Electric. with R-410A

MicroMetl INSTALLATION INSTRUCTIONS FOR 0689ZJ36EC

Assembly Instructions

INSTALLATION INSTRUCTION ELECTRIC HEATER ACCESSORY MODELS 2NH THRU 2NH045025, 2NP THRU 2NP045025, 2ND , AND 2NX GENERAL

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

INSTALLATION PROCEDURE, HHT WITH BULKHEAD. Vehicle prep

RPGE13. Product Specifications. 13 SEER Gas / Electric Residential Packaged Unit. Refrigerant System. Heat Exchanger. Cabinet Construction.

TECHNICAL GUIDE FLEXIBLE LIGHT COMMERCIAL UNIT CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS

Installation Instructions

ELECTRIC HEAT ACCESSORY INSTALLATION INSTRUCTION. 20, 30 & 40 kw for 15 Ton Split System Air Conditioners Models: LB180 & LL A-0102

ZHA/ZHB SERIES WARNING

ac-500 hot surface ignition & i.i.d.spark ignition vertically fired gas convection oven

19" ELECTRIC WALK BEHIND MOWERS SERIES 1, 3, & 5

I-VIC300MS. Vic -300 MasterSeal Butterfly Valves WARNING SERIES 761

AC-500 HOT SURFACE IGNITION & I.I.D.SPARK IGNITION VERTICALLY FIRED GAS CONVECTION OVEN REPLACEMENT PARTS LIST

SECTION 10 - ELECTRICAL

R6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/Electric Units 3-5 Ton Units

Mfg. No: EED, B&S 11.5 Gross TP 22" Single

INSTALLATION INSTRUCTION ELECTRIC HEATER ACCESSORY MODELS 2NH THRU 2NH045025, 2NP THRU 2NP045025, 2ND , AND 2NX GENERAL

Factory Option Codes L M E S P R D V F F H E

SUNLINE 2000 (WORLD 50 HZ)

ZIP Economizer Fault Detection and Diagnostics (FDD) Table

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

SUNLINE 2000 SINGLE PACKAGE AIR - TO - AIR HEAT PUMPS DESCRIPTION. B1CH 180 & and 20 NOMINAL TONS ( EER)

I-VIC300MS. Series 761 Vic-300 MasterSeal Carbon Steel Butterfly Valve Series 461 Vic-300 MasterSeal Stainless Steel Butterfly Valve WARNING

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP

PGAA SERIES 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

13 SEER. Light Commercial 3 Phase Packaged Heat Pump. RHP13 Features and Benefits. Refrigerant System. Cabinet Construction. Blower.

ACCESSORY KIT INSTALLATION INSTRUCTIONS

R6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/ Electric Units with R-410A 3-5 Ton Units WARRANTY

P8SE Series. 14 SEER, Three Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

ELECTRIC START KIT KIT P/N

GR4GC Series Single Packaged Gas/Electric Units

INSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD

Installation Instructions

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

ENERGY RECOVERY SYSTEM 60 HZ

DESCRIPTION SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DBUC/DBHB NOMINAL TONS 8.5 EER

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

VENTILATION SYSTEM SECTION VTL CONTENTS VENTILATION, HEATER & AIR CONDITIONER VTL-1 FUNCTION DIAGNOSIS... 3 PRECAUTION... 6 PREPARATION...

GR4GA Series Single Packaged Gas/Electric Units

ILL. 1. Horizontal. supply air cover panel shipped on HVAC unit. Access door/ panel

PGMD Series 10 SEER. International Comfort Products 651 Heil Quaker Avenue Lewisburg, Tn Part No

FOLDING TOP HYDRAULIC CYLINDER HOSE IDENTIFICATION

INSTALLATION INSTRUCTIONS

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

Safety & Installation Instructions

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997

Installation Instructions

Remote engine start INSTALLATION INSTRUCTIONS

SINGLE PACKAGE HEAT PUMPS

INSTALLATION INSTRUCTIONS FOR DSP9600/9100 WHEEL BALANCER

SUNLINE 2000 TM TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE AIR-TO-AIR HEAT PUMPS

SAFETY INSTRUCTIONS Before installation and operation, read these instructions carefully and use this product only in the manner described by the manu

SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS SUNLINE 2000 DESCRIPTION

ENCORE 52" X-TREME. 2-BAG GRASS CATCHER for units w/ S/N and above ASSEMBLY AND PARTS DIAGRAMS

MODEL ELC-12/40-CVM-D BATTERY CHARGER

97-02 JEEP TJ BODY LIFT KIT INSTRUCTIONS

Transcription:

FOR 6.5 THRU 12.5 TON SINGLE PACKAGE EQUIPMENT MODEL AIR CONDITIONERS Gen eral The instruction provides all the necessary information to properly field install this economizer on the above indicated equipment. Economizer Model 2EE04703324 has a single input solid state enthalpy sensor that provides automatic 100% outdoor air capability with 2% leakage. Refer to the respective unit wiring diagram for information regarding electrical circuitry on the economizer. A relief air damper for barometric air balance is provided with each basic unit and is mounted on the face of the return air damper section. Refer to the basic unit installation instruction for additional information. Step 1: PANELS TO BE REMOVED FRESH AIR DAMPER RETURN AIR DAMPER Verify all unit parts in box. a. 1 ea. - Return Air Damper b. 1 ea. - Fresh Air Damper c. 1 ea. - Hood Package 1 ea. - Fresh Air Hood 1 ea. - 22 x 30 1 8 x 1 Mist Eliminator Filter 1 ea. - Hardware Bag: 21 ea. - Type A #10-16 x ½ Screws 4 ea. - Self tapping #10-16 x ½ Screws 10 ft. - 1 8 x 1 2 Gasket HOOD PACKAGE

Step 2: Remove the Discharge Air Sensor from the fresh air damper and save for later installation (Step 12). Step 3: To assemble the Fresh Air Hood use the Type A #10-16 x ½ screws (Qty 21) provided. Follow these steps: DISCHARGE AIR SENSOR A. Take (1) and align holes of (2) with holes of (1) and screw in place. B. Take (3 & 5) and align holes of (4) with holes of (3 & 5) and screw in place. C. Take (1) and (3) put the flange of (1) to the inside of (2) and screw in place. D. Take (5) and screw in place like Step C. E. Take (6) and place flanges over (3 & 5) and secure. F. Slide filter (7) into (4). G. Take (8) and do the same as Step E. Set Fresh Air Hood to the side for use in Step 10. (6) (4) (5) (8) ALIGN HOLES (7) (2) 31 11 16 18 1 2 (3) (1) 12 1 4 ALIGN HOLES 21 9 16 Step 4: Remove the return air duct cover and the two (2) rear panels from the end of the unit as shown. Keep screws to use later in Steps 10 and 13. HORIZONTAL DUCT OPENING WITH COVER AND END PANELS REMOVED

HOLES TO ATTACH FRESH AIR DAMPER Step 5: Install the return air damper into the horizontal return air duct opening as shown. Using the self tapping #10-16 x ½ screws provided secure to duct connection (two on each side). The two holes with bushings will be on the right hand side and the damper bracket will be on the damper bottom inside the unit. TWO HOLES WITH BUSHINGS DAMPER BRACKET Step 6: Slide the fresh air damper into the unit as shown using some of the screws removed in Step 5. Step 7: Secure the fresh air damper to the unit with the screws removed in Step 4 though the slotted holes in the damper section. Do Not tighten screws at this time. Step 8: Connect the linkage from the fresh air damper to the return air damper. The linkage rod is shipped connected to the fresh air damper. To connect the linkage to the return air damper, open the return air damper and insert the rod through the opening in the damper bracket. With the rod through the return air damper bracket, close the return air damper tightly, and tighten the set screw on the return air damper bracket as shown. Note: Linkage rod should be flush with the back of the return air damper bracket.

Step 9: Plug the economizer cable into the unit as shown. The jumper plug that ships with the unit should be removed and saved in the control compartment for future needs. ECONOMIZER CABLE Step 10: Install the assembled Fresh Air Hood as shown. Using the keyhole slots on the barometric relief hood, place the barometric relief hood over the screws and slide down into the slots and tighten screws in place. This is the time to tighten all screws that were previously not tightened. Step 11: FLANGE ON HOOD SIDE If the barometric relief is to be installed cut a 20 x 21 hole in the return air duct near the Economizer. (Note: Barometric relief must be ordered separatley. Step 12: Secure barometric releif damper over hole in return air duct using (8) screws. 20 24 20 7 8 RETURN DUCT 24 3 4 27 3 4 BAROMETRIC RELIEF DAMPER (1RD0411)

Step 13: Reinstall the top rear panel which was removed in Step 5 of the unit using the remaining screws also removed in Step 5. TOP REAR PANEL Step 14: The Discharge Air Sensor installs in the blower compartment of the unit. Open the access door to the blower and you will see a cable on the left side. The cable has two wires with insulated connectors that the Discharge Air Sensor plugs into. These wires are shown in the photo. Plug the Discharge Air Sensor wires into those provided inside the unit, and using a wire tie, strap the Discharge Air Sensor to the cable as shown below. DISCHARGE AIR SENSOR WIRES CONTROL CURVE CONTROL POINT APPROX. o F ( o C) AT 50% RH A 73 (23) B 70 (21) C 67 (19) D 63 (17) WIRE TIE DISCHARGE AIR SENSOR APPROXIMATE DRY BULB TEMPERATURE - o F ( o C) 1 HIGH LIMIT CURVE FOR W6210D, W7210D, W7459D. JULY 21, 2000 FORM# YKIHE29B

S7/P7 ECONOMIZER SECTION SOCKET /PLUG CONNECTION DAS DISCHARGE AIR SENSOR S12/P12 POWER EXHAUST SOCKET/PLUG CONNECTION M5 POWER EXHAUST CONTACTOR RC CAPACITOR ES1 POWER EXHAUST END SWITCH NOTES: 1. ALL FIELD WIRING TO BE ACCOMPLISHED FOLLOWING CITY, LOCAL AND/OR NATIONAL CODES IN EFFECT AT TIME OF INSTALLATION OF THIS UNIT. 2. CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSED IMPROPER AND DANGEROUS OPERATION. IF ANY OF THE WIRE, AS SUPPLIED WITH THE UNIT MUST BE REMOVED. IT MAY BE REPLACED WITH TYPE 105 DEGREE C, GOO VOLT WIRE OR EQUIVALENT CLEARLY RENUMBERED FOR IDENTIFICATION. VERIFY PROPER OPERATION AFTER SERVICING. 3. WHEN ECONOMIZER IS INSTALLED REMOVE PLUG WITH JUMPER WIRE 816/Y