Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1

Similar documents
Assembly. Trunk IN + - S U, I U, I. Spur 1

Fieldbus Segment Protector F2-SP-IC* Features. Assembly. Function. Connection. Zone 2 Div. 2

Service Fieldbus Engineering and Consulting

*-JBSC-* Fieldbus junction box with integrated short-circuit current limitation

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS5500 Wire rope load cell

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS5190 Trough hole (annular) heavy capacity load cell

ABB MEASUREMENT & ANALYTICS DATA SHEET. Series and Katharometer power supply units

FICHA TÉCNICA DE PRODUTO

BRIDGE-BOY Load limitation electronics with 1 or 3 set points

RSDE10 / RSDE20 (Contrac) Electrical Linear Actuator

Terminal Boxes in Stainless Steel SLS**.T

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

Solenoid Valve Island Type 3965

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Shut-off valves and accessories for pressure measuring instruments

RS85 Vibrating fork level switch

PROCESS AUTOMATION. Instruction Manual JUNCTION BOXES/ SEGMENT PROTECTORS

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

RSD100 (Contrac) Electrical Linear Actuator

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

Moving Coil Indicators with direct temperature sensor input

CoriolisMaster FCB430, FCB450, FCH430, FCH450 Coriolis Mass Flowmeter

EAS822 (Contrac) Power Electronic Unit

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

ABB i-bus KNX DG/S x DALI-Gateway Basic

Additional Information. Measurement made easy

MW05 MagWave Magnetic Level Gauge. Dual chamber level system K-TEK Products

Resistance thermometer Without thermowell Model TR10-H

Type Z & Ex pz purge and pressurization system

Surface thermocouple Model TC50

ABB i-bus KNX Hotel IP Link, Bundle HIL/S , 2CDG110237R0011

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

ABB i-bus KNX HIL/S , Hotel IP Link, Bundle

Thermocouple For additional thermowell Model TC10-B

For single and double operated actuators. Exhaust air recirculation (3/2 way function)

Solenoid Valves Type 3963

Leading the way in hazardous areas Features EATON

AT100 Magnetostrictive Level Transmitter. High accuracy magnetostrictive liquid level transmitter K-TEK Products

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

Terminal Boxes Series 8125

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Emergency-off application Manual motor starter MS116/MS132 Undervoltage release UA1

Manual motor starter MS132

Model WEP Electro-pneumatic positioner. WEP positioner A valve control without compromise

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

Manual motor starter MS132

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Additional Information. Measurement made easy

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Manual motor starter MS132

CEAG Products Main Catalogue Part 1 Chapter 3. Emergency and safety light fittings. EATON 1.3.1

Direct-acting 3/2 way plunger valve

Cable resistance thermometer Model TR40

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

Thermal overload relay TF65 and TF96

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

Thermal overload relay TF140DU and TF140DU-V1000

Resistance thermometer Model TR10-E, for additional thermowell

Manual motor starters Overview and benefits

Reed sensor For bypass level indicators Model BLR

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

POSITIONERS and Controls for Complete Valve Automation

Low Voltage Systems MNS and MNS is PowerCenter

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. Electronic unit and accessories Retrofitting on Contrac

Resistance thermometer Model TR10-B, for additional thermowell

97300 NAMUR 3/2 & 5/2 way spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, NAMUR Interface

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

I Ex-control stations I

Operating Instructions

Valve Blocks. For direct flanging to pressure and differential pressure transmitters. Drop-forging housing. Replaceable valve seat

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

Sensor boxes SRBE Key features and product range overview

Gas analyzers EL3060 The specialists for hazardous areas

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

For double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring

Resistance thermometer For sanitary applications, exchangeable sensor Model TR22-A

Solutions Ex d IIB+H2, Aluminum and Stainless Steel

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Manual motor starter MS116

Product information. ECOSS Electronic compact starter for wound rotor drives

Manual motor starter magnetic only MO325

Electronic overload relay EF65, EF96 and EF146

Mini contactors B6, BC6 with 3 pole

Electronic overload relays EF205 and EF370

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

CERTIFICATE OF COMPLIANCE

Thermocouples Model TC10-E, for Additional Thermowell

Safety stop buttons Smile, INCA and Compact

Level Measurement Point level measurement - RF Capacitance switches

Solenoid Operator 0516 / 1216

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Type Electronic Limit Switch

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

ZS4 Screw Clamp Terminal Blocks Feed-through

97105 Inline. Ordering information. Technical data. Accessories See page 5

Transcription:

Data Sheet DS/NGB-EN Rev. B Multi barriers Measurement made easy Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1

Change from two to one column Multi barriers Change from one to two columns NGB900 Fieldbus barrier 4 outputs Ex ia IIC. FieldBarrier in Zone 1/Div. 2. Instruments in Zone 0...1/Div. 1. Short circuit current limitation per output. For FOUNDATION Fieldbus H1 and PROFIBUS PA. Power, Com, and Error LEDs. Supports FISCO and Entity. Integrated cable tie-downs. Change from one to two columns The FieldBarrier, a device coupler in an aluminum housing, connects 4 instruments with intrinsic safety (Ex ia/ex ib) and short circuit current limitation at each output. This ensures proper operation of the segment during faults or hot work at the spur. The F2 housing is made of sturdy cast aluminum for installation in rough environments. High power on the trunk enables maximum cable lengths and device count in any hazardous area. The integrated fieldbus terminator features high-availability design and is selectable. A choice of fixed screw or spring output terminals connect 1 device each. LEDs simplify troubleshooting and help decrease repair time. Hard and capacitive grounding and shielding concepts can be chosen via jumper. 2 DS/NGB-EN Rev. B Multi barriers

NGB900 Fieldbus barrier Specifications Fieldbus interface Main cable (Trunk) Connection input (Trunk IN): terminals 3+, 4-, 5s output (Trunk OUT): terminals 7-, 8+, 6s Rated voltage 16 V DC / 32 V DC Rated current 31 ma / 26 ma (no spur load) 44 ma / 38 ma (at 1x 20 ma spur load) 115 ma / 77 ma (at 4x 20 ma spur load) 221 ma / 122 ma (at 4x 43 ma spur load) 140 ma / 84 ma (at 3x 20 ma & 1x short-circuit) 241 ma / 135 ma (at 4x short-circuit) Voltage drop trunk IN to trunk OUT 100 mv max. Number of barriers max. 4 per segment Outputs (Spurs) Number of devices per 1 output (Spurs) Connection output 1: terminals 10+, 11-, 12S shield; output 2: terminals 13+, 14-, 15S shield; output 3: terminals 16+, 17-, 18S shield; output 4: terminals 19+, 20-, 21S shield Rated voltage 10... 13 V Rated current 43 ma Short-circuit current 50 ma General specification Design / Mounting Outside installation Conformity Degree of protection EN 60529 Shock resistance EN 60068-2-27 Vibration resistance EN 60068-2-6 Ambient conditions Ambient temperature see table 2 Storage temperature -40 85 C (-40 185 F) Mechanical specifications Enclosure cover detachable cover with retaining screws Degree of protection IP 67 Cable entry cable gland and stopping plug options see separate table Material Housing ALSI12 (Cu) DIN1725 (Si 1.2%), anodized Surface painted green Seal silicone, one piece Mass 3350 g Dimensions see figure 2 and see table 2 Mounting thru-holes Ø6.5 mm Grounding M5 threading for grounding bolt Terminating impedance 100 Ω switchable Indicators / operating means LED voltage Fieldbus green: on, bus voltage existent LED status output red flashing: short-circuit Multi barriers DS/NGB-EN Rev. B 3

Multi barriers NGB900 Fieldbus barrier Ex relevant specifications Data for application in connection with Ex-areas EC-Type Examination Certificate PTB 02 ATEX 2086 Group, category, type of protection, temperature class II 2 (1)G Ex e mb [ia Ga] IIC T4 Gb II 2 G (1D) Ex e mb [ia IIIC Da] IIC T4 Gb Declaration of conformity CERT-3315 Group, category, type of II 3 D Ex tc IIIC T135 C Dc protection, temperature class Directive conformity Directive 94/9/EC EN 60079-0:2012 EN 60079-7:2007 EN 60079-11:2012 EN 60079-18:2009 EN 60079-31:2009 International approvals FM approval CoC 3015728 Control drawing No. 116-0226 Approved for Class I, Division 2, Groups A, B, C, D / Class I, Zone 2, AEx na [ia] IIC T4 CSA approval CoC 1592754 Control drawing 116-0266 Approved for Class I, Division 2, Groups A, B, C, D / Class I, Zone 2, Ex na [ia] IIC T4 IECEx approval IECEx PTB 03.0003 Approved for Ex me [ia] IIC T4 Certificates and approvals FOUNDATION Fieldbus FF-846 Marine approval DNV A-14038 General information Supplementary information EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. 4 DS/NGB-EN Rev. B Multi barriers

NGB900 Fieldbus barrier Change from two to one column Mounting dimensions Fieldbus barrier with aluminium housing, connection variants and dimensions see table 2... 3 Multi barriers DS/NGB-EN Rev. B 5

Change from one to two columns Multi barriers NGB900 Fieldbus barrier Electrical connections S1: Fieldbus terminator, switchable 6 DS/NGB-EN Rev. B Multi barriers

Change from one to two columns Change from two to one column NGB900 Fieldbus barrier Table 1: Connection of terminals Terminals Functions 10+, 13+, 16+, 19+ Spur Ex ia + 11-, 14-, 17-, 20- Spur Ex ia - 12s, 15s, 18s, 21s Spur shield 3+ Trunk 1, Ex e + 4- Trunk 1, Ex e - 5s Trunk 1, shield 7- Trunk 2, Ex e - 8+ Trunk 2, Ex e + 6s Trunk 2, shield 1B Spur, shield bridge 2B Trunk, shield bridge PA Potential equalization The terminals 5s and 6s are connected internally with terminal 2B. The terminals 12s, 15s, 18s and 21s are connected internally with terminal 1B. The terminal PA is connected to the housing grounding point (versions with field housing only). Capacitive grounding is delivery standard for the cable shields. By bridging 1B and 2B the trunk shields can be hard grounded. Change from two to one column Table 2: Variations of cable connections, housing types and temperature ranges Type of connection, Type of cable connection F2 housing, outside SW1 (mm) SW2 (mm) Temperature range identification F, G dimension "X" (mm) ( C) CG Terminals, cable glands plastic 140 20 24-30... 70 Table 3: Cable diameter depending on cable gland Type of connection, identification F, G Output cable diameter (mm) Trunk cable diameter (mm) CG 5 10 7 12 Change from two to one column Ordering information Fieldbus barriers for PA / H1 segments NGB900 Fieldbus barrier in an aluminium housing 4x [Ex ia/ex ib] and 2x (Ex e) cable bushing plastic (shielding capacitive!), switchable bus termination IP 67, Zone 1 / Div. 2 Catalog No. (204715-0001) 3KXN611900L0010 Based on T157030_ENG.xml / RD 2015-10-07 Multi barriers DS/NGB-EN Rev. B 7

Contact us ABB Automation GmbH Service Instrumentation Kallstadter Straße 1 68309 Mannheim Germany Customer Service Center: +49 180 5 222 580* E-Mail: automation.service@de.abb.com www.abb.com/measurement * 14 cents/minute from German landlines, Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents - in whole or in parts is forbidden without prior written consent of ABB. DS/NGB-EN Rev. B 01.2017 max. 42 cents/minute from mobiles. Copyright 2017 ABB All rights reserved 3KXN611000R1001 Sales Service