Operating Instructions 2-channel pushbutton interface 4-channel pushbutton interface

Similar documents
Operating Instructions. Tronic Dimmer

Operating Instructions Electronic transformers for lowvoltage halogen lamps

1 Safety instructions. 2 Device components. Blinds Management Motor control insert Universal AC 230 V ~ Art. No. 232 ME. Operating instructions

1 Safety instructions. 2 Device components. Light Management Rotary dimmer. Operating instructions

ABB i-bus KNX Hotel IP Link, Bundle HIL/S , 2CDG110237R0011

ABB i-bus KNX HIL/S , Hotel IP Link, Bundle

Figure 1: Device components

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S

Room Controller LS 990 / LS plus Stainless Steel / Aluminium

1 Safety instructions. 2 Device components. Light Management LED touch dimmer insert. Art. No LEDDE. Operating instructions

ABB i-bus KNX DG/S x DALI-Gateway Basic

Local Control Network - building controls in perfection

Energy Profile Installation Instructions

ABB i-bus KNX Magnetic Contact EnOcean, 868 MHz MKE/A , 2CDG R0011

DALI-Gateway DG/S ABB STOTZ-KONTAKT GmbH G. Schlag. Folie 1

Motor Starter Reverse MSR22-FBP

Battery Voltage, Overload Protected Hot only in Start & Run 15 GN (green)

ThunderION. Static Neutralising System. GB User's Manual 2

Safety Sensor CSS 180 Product Information

Pressure/vacuum switch (V)PE-1/8-...(-SW) PE-PK-...(-SW)

LED Driver Compact fixed output

LED Driver Compact fixed output

zelsius Installation and operating manual All that counts EnergyMetering

zelsius Installation and operating manual All that counts. EnergyMetering

Operating instructions Safety sensor EX-CSS About this document. Content. 7 Disassembly and disposal 7.1 Disassembly Disposal...

Series 7000 Torque Sensor for PTO-shafts

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

Series 7000 Torque Sensor for PTO-shafts

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

Tina 10A/B/C Adaptor unit

3 CE-Conformity. General information. Signal lamps. 3-2 Signal lamps

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series

RT2DB Excitation and voltage regulation system for synchronous generators

LEDLINE ECX. LED Constant Current Drivers ELECTRONIC CONSTANT CURRENT DRIVERS LED CONSTANT CURRENT DRIVERS

Electronic Ballast EVG 2000-T

Emergency lighting units EM powerled

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

1 Safety instructions. 2 Device components. System Blind control insert with auxiliary input

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

Operating Instructions

ABB i-bus KNX Room Master, MDRC RM/S 4.1, 2CDG R0011

Safety Door Handle System with SIDENT Safety Switch Ref. no , -11, -12

Touch Sensor 2 plus Installation Instructions

FMC-1/2 Tina Muting unit

Solenoid Valves Type 3963

Technical Documentation

Oxymax W COS31. Brief Operating Instructions. Dissolved oxygen sensor

VAPORIX-PCM. Technical Documentation. Corrective control module for connection to VAPORIX-Control. Version: 3 Edition: Art.

Smile 11 RA/-B Smile 12 RF/-G Reset button

Operating instructions. FreeCon Contactless Power Contactless power transmission IE-CL240W-PP-BASE IE-CL240W-PP-REMOTE

VAPORIX The Automatic Monitoring System for Active Vapour Recovery

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS

Vehicle CAN Database. Porsche 911 (991) GT3 Cup Gen1 - Bosch Connector

Valve terminal VTUG-...-M/VTUG-...-V

Recommended spare parts and often used accessories

Mar H: SUPPLEMENTAL PARALLELING GEAR (16315-H)

Overview of operation modes

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

Wilo-Control SC-Fire Jockey

Duris E5 PowerFlex LED Strips 7.5mm LED Pitch

Operating instructions Binary level sensor. LI214x /00 04/2016

Temposonics. G-Series Analog Redundant. Magnetostrictive Position Sensors. Redundancy for enhanced safety

System 2000 DRA automatic stairway lighting, Impulse insert. 1 Safety instructions. 2 Device components

Aurora Wind Interface Box

Duris E5 PowerFlex LED Strips 7.5mm LED Pitch

Recommended spare parts and often used accessories

Magnetic switch For bypass level indicators Model BGU for nuclear power plants

JUMO ecotrans Lf 01/02

Heat Meter Integrator

Turny Evo. Autoadapt. Seat lift. Installation manual

Tina 11A Connection block

Type Operating Instructions. Bedienungsanleitung Manuel utilisateur

Solenoid Valve Island Type 3965

Operating Instructions. bluesmart Active

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

AWZ 200. AWZ 13,8V/2A/7Ah/L

HYDRUS ULTRASONIC METER

Your Global Automation Partner. LTX Linear Position Sensors with SSI Interface. Operating instructions

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal touch dimmer insert LED

Emergency lighting units EM powerled

1x 20A H Bridge output for controlling direction of DC motors through polarity change (MOI)

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Emergency lighting units EM powerled

Emergency lighting units EM series

HST-BL-2830MS & HST-BL-2830MS-USA

Flowmeter Ultrasonic Flow Metering / Dosing Device. Operating Manual

Dragon 4 IR 12 PowerCluster

Series 77 & 78. Compact & Modular Valves. solutions. Series 77 - Compact Valves. Series 77 - Sub-D. Series 77 - Fieldbus

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies

fluid technology temperature sensors 1600 intelligent temperature sensor membrane keyboard, USB opto interface

OPERATING INSTRUCTIONS

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Electronic Circuit Breaker ESS20-0..

PHOENIX CONTACT - 01/2008

onlinecomponents.com

Operation Manual for Torque Sensors

Emergency lighting units EM powerled

Transcription:

Ref-no.: 2076-2T Operating Instructions 2-channel pushbutton interface 4-channel pushbutton interface 1. Safety warnings Electrical equipment must be installed and fitted by qualified electricians only and in strict observance of the relevant accident prevention regulations. Failure to observe any of the installation instructions may result in irreparable damage, in fire and in other hazards. 2. System information This unit is a product of the instabus-eib-system and corresponds to the EIBA Guidelines. Detailed technical knowledge acquired in instabus training courses is a prerequisite for the understanding of the system. The functions of the device are software-dependent. Detailed information on the software and the functions implemented and the software itself are available from the manufacturer s product data bank. Planning, installation and commissionning of the device are effected with the help of EIBA-certified software. The updated product database and the technical description are available in the Internet under www.jung.de. Stand: Jun-08 825 238 13

3. Function The 2-channel and 4-channel pushbutton interfaces are equipped with 2/4 independent channels which depending on parameterization may be used as inputs or alternatively also as outputs (channels 1 or 2 only). The pushbutton interfaces can evaluate at their potentialfree inputs up to 2/4 pushbutton / switch states with a common reference potential and send the corresponding telegrams over the instabus EIB. The telegrams may be telegrams for switching or dimming, for blind/shutter control or for value transmitter applications (dimming value transmitter, light-scene extension, temperature or brightness value transmitters). Moreover, switch or pulse counters are available (2-channel type: 1 counter, 4-channel type: 2 counters). As an alternative, channels 1 and 2 can control up to 2 light-emitting diodes (LED) as independent outputs. To increase the output current (see technical data), these channels can also be connected in parallel with the same parametrization. The outputs are protected against short circuits, overload and wrong polarity. 4. Safety warnings The connection of 230 V signals or other external voltages to the inputs is not permitted! The voltage potentials of the connecting lines for the contacts and the LEDs are not electrically separated from the the bus voltage. Connect ONLY potential-free pushbuttons / switches to the inputs. 5. Fitting instructions To prevent EMC-related interference, do not run the lines to the inputs (D) in parallel with lines lines carrying mains voltage or with lines feeding loads. Figure 1 Fig. 1: The bus is connected with bus connecting terminal (A). The physical address is programmed by means of programming button (B) and programming LED (C). 2

Wiring of 4-channel pushbutton interface Switches and pushbuttons or LEDs are connected to the device by means the connecting cable supplied (D) as shown in figs. 2 and 3. Colour coding: Green (GN): channel 1 (E1/A1) Red (RD) : channel 2 (E1/A2) Yellow (YE) : channel 3 (E3) Pink (PK) : channel 4 (E4) Grey (GY) : reference potential (com) Figure 2 Fig 2: Example for 4-channel pushbutton interface with 4 inputs Figure 3 Fig. 3: Example for 4-channel pushbutton interface used with 2 inputs and 2 outputs 3

Wiring of 2-channel pushbutton interface Switches and pushbuttons or LEDs are connected to the device by means of the connecting cable supplied as shown in figs. 4 and 5. Colour coding: Green (GN): channel 1 (E1/A1) Yellow (YE) : channel 2 (E1/A2) Grey (GY) : reference potential (com) Figure 4 Fig. 4: Example for 2-channel pushbutton interface with 2 inputs Figure 5 Fig. 5: Example for 4-channel pushbutton interface used with 1 input and 1 output 4

6. Technical data Supply instabus EIB : Power consumption : Connection instabus EIB : Inputs / Outputs dual type : quad type : length : recommended cable : 21 32 V DC typically 150 mw instabus connecting terminal 3-wire cable set 5-wire cable set 25 cm, can be prolonged to 5 m max. EIB bus line J-Y(St)Y 2x2x0.8mm Inputs dual type : up to 2 (depending on application) quad type : up to 4 (depending on application) Outputs for LEDs : max. 2 constant current : 0.8 ma per output Dimensions (W x H x D) : 44 x 29 x 16 mm Ambient temperature : -5 C... +45 C Type of protection : IP 20 Safety class : III Technical specifications subject to change. 7. Acceptance of guarantee We accept the guarantee in accordance with the corresponding legal provisions. Please return the unit postage paid to our central service department giving a brief description of the fault: ALBRECHT JUNG GMBH & CO. KG Service-Center Kupferstr. 17-19 D-44532 Lünen Service-Line: +49 (0) 23 55. 80 65 51 Telefax: +49 (0) 23 55. 80 61 89 E-Mail: mail.vki@jung.de Technik (allgemein) Service-Line: +49 (0) 23 55. 80 65 55 Telefax: +49 (0) 23 55. 80 62 55 E-Mail: mail.vkm@jung.de Technik (KNX) Service-Line: +49 (0) 23 55. 80 65 56 Telefax: +49 (0) 23 55. 80 62 55 E-Mail: mail.vkm@jung.de The -sign is a free trade sign addressed exclusively to the authorities and does not onclude any warranty of any properties. 5