Homepage > Prodotti > Elementi ed unità filtranti > Cassonetti terminali per l'alloggiamento di filtri a piccole pieghe > Terminali filtranti per camere bianche > Type TFP Type TFP FOR CRITICAL AIR CLEANLINESS AND VERY CRITICAL HYGIENE REQUIREMENTS, SUITABLE FOR CEILING INSTALLATION Pharmaceutical clean room terminal filters as final filter stage with Mini Pleat filter panels for the separation of suspended particles. Used in highly sensitive areas in pharmaceuticals, medicine, and biology Mini Pleat filter panels with downstream fluid seals meet the highest hygiene requirements Easy, time-saving, and secure filter change Diffuser face is held in place by magnets and can be hinged down to facilitate cleaning and validation; filter change without tool Robust, welded construction Compact construction, suitable for low ceilings Various diffuser face plates to ideally meet individual requirements Horizontal or vertical connection Removable spigot for installation into closed ceilings in case of horizontal connection For air cleanliness classes 5 to 8 according to ISO 16-1 Meets the hygiene requirements of VDI 6022
APPLICATION Application Pharmaceutical clean room terminal filter type TFP for ceiling installation as final filter stage and for air distribution in sensitive areas of the pharmaceutical industry Fitting of filter elements for the separation of suspended particles such as aerosols, toxic dusts, viruses and bacteria from the supply or extract air Special characteristics Compact construction Flush ceiling installation Removable spigot for installation into closed ceilings Diffuser face plate can be hinged down Nominal sizes [mm] 00, 500, 600, 625 DESCRIPTION Variants TC: Top entry circular spigot SC: Side entry circular spigot SCR: Side entry circular spigot, removable Construction Sheet steel, powder-coated RAL 9010, pure white Attachments FD: Ceiling swirl diffuser TDF: Ceiling swirl diffuser Useful additions
Mini Pleat filter panels (MFP) Suitable filter elements to be ordered separately Construction features Welded filter casing with sealing frame for fitting filter elements, with a seal on the downstream side Mounted pressure measurement points to monitor the operating differential pressure and with internal measuring tube Materials and surfaces Casing and diffuser face plate made of sheet steel, powder-coated RAL 9010, pure white Standards and guidelines Hygiene meets the requirements of VDI 6022, VDI 3803, DIN 196 Part, ÖNORM H 6021 and ÖNORM H 6020, SWKI VA 10-01 and SWKI 99-3, and EN 13779 Maintenance Diffuser face plate can be hinged down to facilitate disassembly and cleaning Particulate filter need not be removed for cleaning (seal on downstream side) Easy change of filter elements due to special frame profile; no additional fluid sealing frame is necessary TECHNISCHE INFORMATION Function, Specification text, Order code, Related products FUNCTION
SPECIFICATION TEXT Pharmaceutical clean room terminal filter type TFP for ceiling installation as final filter stage and for air distribution in sensitive areas of the pharmaceutical industry. Fitting of filter elements for the separation of suspended particles such as aerosols, toxic dusts, viruses and bacteria from the supply or extract air. Welded filter casing with sealing frame for fixing the Mini Pleat filter panels, with a fluid seal on the downstream side. With top entry or side entry spigot; removable spigot as an option. The Mini Pleat filter panels are pressed into place using a tensioning frame with knurled screws. Casing with mounted pressure measurement points to monitor the operating differential pressure and with internal measuring tube. Diffuser face plate made of sheet steel, powder-coated (RAL 9010), types FD and TDF; can be hinged down to facilitate disassembly and cleaning. Leakage test for each casing. Special characteristics Compact construction Flush ceiling installation Removable spigot for installation into closed ceilings Diffuser face plate can be hinged down Materials and surfaces Casing and diffuser face plate made of sheet steel, powder-coated RAL 9010, pure white Construction Sheet steel, powder-coated RAL 9010, pure white
ORDER CODE Variants, Dimensions and weight, Product details
Homepage > Prodotti > Elementi ed unità filtranti > Cassonetti terminali per l'alloggiamento di filtri a piccole pieghe > Terminali filtranti per camere bianche > Type TFP VARIANTS TFP-TC Gehäuse mit rundem Anschlussstutzen Anschlussstutzen oben angeordnet TFP-SC Gehäuse mit rundem Anschlussstutzen Anschlussstutzen seitlich angeordnet TFP-SCR Gehäuse mit rundem Anschlussstutzen Anschlussstutzen seitlich angeordnet Anschlussstutzen demontierbar DIMENSIONS AND WEIGHT Alle Gewichtsangaben sind netto, ohne Verpackung Filtergröße 3 5 6 7 5 6 B H T K M J L kg 00 295 295 85 158 250 365 371 398 30 10 500 395 395 85 250 65 71 98 0 15 198 600 95 95 85 250 565 571 598 50 21 625 520 520 85 198 250 590 596 623 565 23 3 Außenmaß Luftdurchlass Außenmaß Gehäuse 5 Außenmaß Gehäuseflansch 6 Lochabstand Aufhängung oben 7 Gewicht (ca.) Home Contatto Stampa Condizioni generali di vendita e consegna Privacy Disclaimer 26/01/2018 TROX Italia S.p.A.
Homepage > Prodotti > Elementi ed unità filtranti > Cassonetti terminali per l'alloggiamento di filtri a piccole pieghe > Terminali filtranti per camere bianche > Type TFP Filtergröße 3 5 6 7 8 5 6 B H T K M J L G kg 00 295 295 85 158 350 365 371 398 30 265 11 500 395 395 85 198 350 65 71 98 0 25 16 600 95 95 85 198 350 565 571 598 50 25 22 625 520 520 85 198 350 590 596 623 565 25 2 3 Außenmaß Luftdurchlass Außenmaß Gehäuse 5 Außenmaß Gehäuseflansch 6 Lochabstand Aufhängung oben 7 Anschlussmaß bis Stutzenmitte 8 Gewicht (ca.) Filtergröße 3 5 6 7 8 5 6 B H T K M J L G kg 00 295 295 85 158 350 365 371 398 30 255 11 500 395 395 85 198 350 65 71 98 0 235 16 600 95 95 85 198 350 565 571 598 50 235 22 625 520 520 85 198 350 590 596 623 565 235 2 3 Außenmaß Luftdurchlass Außenmaß Gehäuse 5 Außenmaß Gehäuseflansch 6 Lochabstand Aufhängung oben 7 Anschlussmaß bis Stutzenmitte 8 Gewicht (ca.) Installation details, Basic information and nomenclature Home Contatto Stampa Condizioni generali di vendita e consegna Privacy Disclaimer 26/01/2018 TROX Italia S.p.A.
Homepage > Prodotti > Elementi ed unità filtranti > Cassonetti terminali per l'alloggiamento di filtri a piccole pieghe > Terminali filtranti per camere bianche > Type TFP INSTALLATION DETAILS Installation and commissioning Fitting of filter elements with a fluid seal on the downstream side The filter element is pressed into place using a tensioning frame with knurled screws Diffuser face plate is hinged and held in place by magnets; no additional tools required TROX Italia S.p.A. Online-Services Service-Hotlines TROX Academy Your contact partner Online fault report Telefono +39 02-98 29 7.1 Telefax +39 02-98 29 7 60 Via Mecenate 90 20138 Milano ITALY Home Contatto Stampa Condizioni generali di vendita e consegna Privacy Disclaimer 26/01/2018 TROX Italia S.p.A.