Home > Products > Filter elements and filter units > Particulate filter air terminal devices > Pharmaceutical clean room terminal filters > Type TFP

Similar documents
Type TFP FOR CRITICAL AIR CLEANLINESS AND VERY CRITICAL HYGIENE REQUIREMENTS, SUITABLE FOR CEILING INSTALLATION

Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES

Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

HEPA terminal filter units Ceiling diffusers: F640, F650, F654, F655, F656, F659, F660 Wall grilles: F670

Type AK FOR LOW-LEAKAGE SHUT-OFF. Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK

Parts and characteristics

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Ducted HEPA filter units for highly sensitive areas

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK

Ceiling swirl diffusers with perforated face plate

Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

Ceiling swirl diffusers with perforated face plate

Type NAK. Gas-tight shut-off damper with pneumatic actuator

Ceiling swirl diffusers

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Ceiling swirl diffusers

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

Ceiling swirl diffusers

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

RN-S: 80, 100, 125 RN: 80, 100, 125, 160, 200, 250, 315, 400 RN-FL: 100, 125, 160, 200, 250, 315, 400

Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION

Multileaf damper with actuator

Type TVZ. VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Shut-off dampers. Type AKK. For contaminated air PD AKK 1

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

Type VSD35. Nominal length up to 1500 mm: one spigot

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

Slot diffusers for ceiling installation

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

Homepage > Products > Control units > VARYCONTROL > VAV TERMINAL UNITS > Type TVR. Type TVR

CONSTANTFLOW Volume Flow Controllers

Type WG. External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES

Ventilation grilles for installation into walls, sills or rectangular

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element

CAV controllers Type RN

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

Type TVLK OPTIMISED FOR USE IN LABORATORIES AND ON FUME CUPBOARDS

Floor diffusers. The art of handling air. Type FB. In aluminium and plastic

Particle Filter Box FKU

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

Circular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en

2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m

2/1/EN/3. Slot Diffuser. Type VSD15. with 15 mm wide diffuser face

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Volume Flow Limiters Type VFL

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

N O V E L T Y Diffuser with particulate filter class H13

ceiling swirl diffuser DQJ

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

CLAIRE TOTAL SAFETY CABINET TYPE B2 Safe for chemicals due to Total Exhaust

Apartment ventilation

Pressure relief dampers

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

TYPE EK-EU SMOKE CONTROL DAMPER

Type CF FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, FLEXIBLE ALUMINIUM CONSTRUCTION

Apartment ventilation

Particle Filter Box Model FKF

Type Pneumatic actuators

Type Pneumatic actuators

CG INLET CEILING. Inlet ceiling with the laminar discharge flow for operating rooms

JG, JK, JP Ultrafilter

Duct filter units. Duct HEPA filter units AKF

Heat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en

Displacement flow diffusers. L e

TROX Prisliste Filtrering K7-00

Air terminal devices

Splash-proof Terminal HEPA Filter

Ceiling Swirl Diffuser DQJ

Maximum Protection in Filter Systems CGF/CGG. GEA Ceiling Air Outlets Data & Facts. GEA Heat Exchangers / GEA Air Treatment

COMPETENCE BROCHURE Filter Media DELBAG HEPA Filter. Fresh Air Freed of Floating Materials

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

NR series. Circular CAV air volume control terminals with system powered mechanical regulator

A CLEAN AIR WORLD. Rigid, gas tight, shock and vibration resistant. Operating pressure guaranteed to ± 8000 Pa. Functional design, userfriendly

For installation into ductwork

Swirl Diffuser Model DQF

Transcription:

Type TFP FOR CRITICAL AIR CLEANLINESS AND VERY CRITICAL HYGIENE REQUIREMENTS, SUITABLE FOR CEILING INSTALLATION Pharmaceutical clean room terminal filters as final filter stage with Mini Pleat filter panels for the separation of suspended particles. Used in highly sensitive areas in pharmaceuticals, medicine, and biology Mini Pleat filter panels with downstream fluid seals meet the highest hygiene requirements Easy, time-saving, and secure filter change Diffuser face is held in place by magnets and can be hinged down to facilitate cleaning and validation; filter change without tool Robust, welded construction Compact construction, suitable for low ceilings Various diffuser face plates to ideally meet individual requirements Horizontal or vertical connection Removable spigot for installation into closed ceilings in case of horizontal connection For air cleanliness classes 5 to 8 according to ISO 16-1 Meets the hygiene requirements of VDI 6022

APPLICATION Application Pharmaceutical clean room terminal filter type TFP for ceiling installation as final filter stage and for air distribution in sensitive areas of the pharmaceutical industry Fitting of filter elements for the separation of suspended particles such as aerosols, toxic dusts, viruses and bacteria from the supply or extract air Special characteristics Compact construction Flush ceiling installation Removable spigot for installation into closed ceilings Diffuser face plate can be hinged down Nominal sizes [mm] 00, 500, 600, 625 DESCRIPTION Variants TC: Top entry circular spigot SC: Side entry circular spigot SCR: Side entry circular spigot, removable Construction Sheet steel, powder-coated RAL 9010, pure white Attachments FD: Ceiling swirl diffuser TDF: Ceiling swirl diffuser Useful additions

Mini Pleat filter panels (MFP) Suitable filter elements to be ordered separately Construction features Welded filter casing with sealing frame for fitting filter elements, with a seal on the downstream side Mounted pressure measurement points to monitor the operating differential pressure and with internal measuring tube Materials and surfaces Casing and diffuser face plate made of sheet steel, powder-coated RAL 9010, pure white Standards and guidelines Hygiene meets the requirements of VDI 6022, VDI 3803, DIN 196 Part, ÖNORM H 6021 and ÖNORM H 6020, SWKI VA 10-01 and SWKI 99-3, and EN 13779 Maintenance Diffuser face plate can be hinged down to facilitate disassembly and cleaning Particulate filter need not be removed for cleaning (seal on downstream side) Easy change of filter elements due to special frame profile; no additional fluid sealing frame is necessary TECHNICAL INFORMATION Function, Specification text, Order code, Related products FUNCTION

SPECIFICATION TEXT Pharmaceutical clean room terminal filter type TFP for ceiling installation as final filter stage and for air distribution in sensitive areas of the pharmaceutical industry. Fitting of filter elements for the separation of suspended particles such as aerosols, toxic dusts, viruses and bacteria from the supply or extract air. Welded filter casing with sealing frame for fixing the Mini Pleat filter panels, with a fluid seal on the downstream side. With top entry or side entry spigot; removable spigot as an option. The Mini Pleat filter panels are pressed into place using a tensioning frame with knurled screws. Casing with mounted pressure measurement points to monitor the operating differential pressure and with internal measuring tube. Diffuser face plate made of sheet steel, powder-coated (RAL 9010), types FD and TDF; can be hinged down to facilitate disassembly and cleaning. Leakage test for each casing. Special characteristics Compact construction Flush ceiling installation Removable spigot for installation into closed ceilings Diffuser face plate can be hinged down Materials and surfaces Casing and diffuser face plate made of sheet steel, powder-coated RAL 9010, pure white Construction Sheet steel, powder-coated RAL 9010, pure white

ORDER CODE Variants, Dimensions and weight, Product details Home Contact Imprint Disclaimer Privacy 01-27-2018 TROX USA Inc.

VARIANTS TFP-TC Gehäuse mit rundem Anschlussstutzen Anschlussstutzen oben angeordnet TFP-SC Gehäuse mit rundem Anschlussstutzen Anschlussstutzen seitlich angeordnet TFP-SCR Gehäuse mit rundem Anschlussstutzen Anschlussstutzen seitlich angeordnet Anschlussstutzen demontierbar DIMENSIONS AND WEIGHT Alle Gewichtsangaben sind netto, ohne Verpackung Filtergröße 3 5 6 7 5 6 B H T K M J L kg 00 295 295 85 158 250 365 371 398 30 10 500 395 395 85 250 65 71 98 0 15 198 600 95 95 85 250 565 571 598 50 21 625 520 520 85 198 250 590 596 623 565 23 3 Außenmaß Luftdurchlass Außenmaß Gehäuse 5 Außenmaß Gehäuseflansch 6 Lochabstand Aufhängung oben 7 Gewicht (ca.) Home Contact Imprint Disclaimer Privacy 01-27-2018 TROX USA Inc.

Filtergröße 3 5 6 7 8 5 6 B H T K M J L G kg 00 295 295 85 158 350 365 371 398 30 265 11 500 395 395 85 198 350 65 71 98 0 25 16 600 95 95 85 198 350 565 571 598 50 25 22 625 520 520 85 198 350 590 596 623 565 25 2 3 Außenmaß Luftdurchlass Außenmaß Gehäuse 5 Außenmaß Gehäuseflansch 6 Lochabstand Aufhängung oben 7 Anschlussmaß bis Stutzenmitte 8 Gewicht (ca.) Filtergröße 3 5 6 7 8 5 6 B H T K M J L G kg 00 295 295 85 158 350 365 371 398 30 255 11 500 395 395 85 198 350 65 71 98 0 235 16 600 95 95 85 198 350 565 571 598 50 235 22 625 520 520 85 198 350 590 596 623 565 235 2 3 Außenmaß Luftdurchlass Außenmaß Gehäuse 5 Außenmaß Gehäuseflansch 6 Lochabstand Aufhängung oben 7 Anschlussmaß bis Stutzenmitte 8 Gewicht (ca.) Installation details, Basic information and nomenclature Home Contact Imprint Disclaimer Privacy 01-27-2018 TROX USA Inc.

INSTALLATION DETAILS Installation and commissioning Fitting of filter elements with a fluid seal on the downstream side The filter element is pressed into place using a tensioning frame with knurled screws Diffuser face plate is hinged and held in place by magnets; no additional tools required TROX USA, Inc. Online-Services Service-Hotlines USA Representatives Canada Representatives Sales USA and technical consulting +1-770-569-133 305 Settingdown Circle Cumming Georgia 30028 Tel: +1-770-569-133 Fax: +1-770-569-135 Home Contact Imprint Disclaimer Privacy 01-27-2018 TROX USA Inc.