VL Circuit Breaker FG 250A frame Breaker type Defined by the 3rd character of the catalog number K Global, Non-interchangeable

Similar documents
VL Circuit Breaker DG 150A frame

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

Molded Case Circuit Breakers

Tmax Molded Case Circuit Breakers

Speedfax Supplement to Product Catalog. Electrical, Commercial, and Industrial Power Distribution and Control Products

L-Frame. With Standard Line and. Standard Terminals Only. Catalog Number. Price U.S. $ LDB2300 LDB2350 LDB2400 LDB2450 LDB2500 LDB2600

Tmax Molded Case Circuit Breakers

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) RG H ZG E C

Molded Case Circuit Breakers

S4 N 250 B W - 2 xxx. Isomax. Isomax Molded case circuit breakers S3 S8. MCCBs

2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G

VL Circuit Breakers. MG 800A Frame, VL Series. Selection/Dimensions. Revised 03/08/13. Dimensions, inches (mm) Interrupting Ratings

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

Product Line Overview. The Most Logically Designed Contact Assembly

VL Circuit Breaker Features & Benefits. powerful ideas RELIABLE SOLUTIONS

Thermal-Magnetic For Mining Applications Class 600

Molded Case Circuit Breakers

L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

S4 N 250 B W - 2 xxx. Isomax MCCBs. Isomax Molded case circuit breakers S1 S8

SENTRON VL Series Product Specifications

Molded Case Circuit Breakers

Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches. Ex9 Series - M. na.noark-electric.

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

Bulletin 140U R-Frame Molded Case Circuit Breakers

Miniature Circuit Breakers

25.4. Molded Case Circuit Breakers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

Section 3: Molded Case Circuit Breakers

Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches Ex9 Series - M

Technical Information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

Catalog LV 1 Add-On October sentron CIRCUIT-BREAKERS. 3VL Molded Case Circuit-Breakers approved according to UL 489 up to 1600 A

Control Circuit Protection

Molded Case Circuit Breakers Reference Guide

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker

Series KTU7 UL489 Molded Case Circuit Breakers

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB

Series KTU7 UL489 Molded Case Circuit Breakers

Q and M-Frame Circuit Breaker Instruction Leaflet for Installation and Operation for Thermal Magnetic Trip Units

US Brochure. Tmax XT Molded case circuit breakers Simply XTraordinary

Molded Case Circuit Breakers Amperes LSIA. LSIG Catalog Number 3-Pole Standard Interrupting Capacity 600V AC Rated V AC 13,950.

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

Molded Case Circuit Breakers

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Magnum IEC Low Voltage Air Circuit Breakers

Molded Case Circuit Breakers

Molded Case Circuit Breakers

S200 UL 1077 Series S200. Supplementary protective devices. UL 1077 Series. Miniature. circuit breakers. S200 Supplementary protective devices

Series G Moulded Case. Circuit Breakers. Series G Moulded Case Circuit Breakers 1

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

C E R T I F I C A T E O F C O M P L I A N C E

DPX earth leakage DPX 3 -I earth leakage

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

2.3. Molded Case Circuit Breakers. Contents

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

Critical Power Switchboards. Selection and Application Guide

DPX Magnetic only

Type MP-T Type MP-HT Type MP-MT

Molded Case Circuit Breakers

UL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers 1.22 [31.1] 1.77 [45.1] 4.86 [123.4] Clearance 1.77 [45]

Engine Generator Circuit Breakers

Preliminary AC1615S. ABB Molded Case Circuit Breakers

PowerPact B. Molded case circuit breakers and switches from A

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence

Product Line Overview. The Most Logically Designed Contact Assembly

Power Break II Switchboard

S200-C, 480Y/277 VAC Supplemental protectors UL 1077, CSA 22.2

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

PD-Series Ground Fault Circuit Protection

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame


PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers

Selection Information Molded Case Circuit Breakers

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Section 3. Molded Case Circuit Breakers.

LOW VOLTAGE SWITCHGEAR

Supplementary Protectors. Circuit Breakers & Circuit Breakers & Supplementary Protectors Contents

3.1. Power Breakers, Contactors and Fuses. Contents. Series NRX Low Voltage Power Circuit Breakers. Power Circuit Breakers

2.3. Molded Case Circuit Breakers. Contents. Internal Accessories. Series C. Product Overview. Description

System pro M compact Miniature Circuit Br eakers Description Features

Molded Case Circuit Breakers Industrial Circuit Breakers A Thermal Magnetic Trip. Section 3. BuyLog Catalog 3-29

SENTRON Switching and Protection Devices Molded Case Circuit Breakers

SB Encased Systems Breakers, Trip Units and Accessories. Selection and Application Guide October 1, 1999

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

Phone: Fax: Web: -

SD Series Non-Fused Load Switches

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD

Series L9 UL-489 Miniature Circuit Breakers

A. Submit manufacturer's literature and technical data before starting work.

Jtec 489 UL489 Branch Circuit Breaker

Transcription:

VL Circuit Breaker FG 250A frame Breaker type Defined by the 3rd character of the catalog number K Global, Non-interchangeable Trip unit type Defined by the 5th character of the catalog number B Thermal-magnetic, model 525 N LI, electronic, model 545 P LSI, electronic, model 545 X LIG, electronic, model 545 U LSIG, electronic, model 545 D LSI, electronic with LCD, model 576 E LSIG, electronic with LCD, model 576 R LI, electronic, Model 555 T LSI, electronic, Model 555 W LIG, electronic, Model 555 V LSIG, electronic, Model 555 A LSI, electronic with LCD, Model 586 G LSIG, electronic with LCD, Model 586 K LSI + GF alarm, electronic with LCD, Model 586 For DC applications, use thermal magnetic trip unit only. For reverse-feed applications, select non-interchangeable trip breakers only. Due to the location of the magnetic tripping solenoid, the left accessory pocket of electronic breakers is not available for accessories. HACR rated. b Interrupting ratings RMS symmetrical amperes (ka) UL 489 IEC 60947-2 UL or IEC Volts AC Volts AC Volts DC a Interrupting Breaker 240 480 600Y/347 240 Class Type I cu /I cs 415 I cu /I cs 690 I cu /I cs 250 500 600 N NFGB 65 35 18 65 / 65 40 / 40 12 / 6 30 18 H HFGB 100 65 18 100 / 75 70 / 70 12 / 6 30 18 42 L LFGB 200 100 18 200 / 150 100 / 75 12 / 6 30 18 UL / CSA / NOM 40ºC 50/60Hz IEC 40ºC 50/60Hz a For DC applications and wiring diagrams, see p. 5 of VL Information Guide. b Special version, Type HFGD. See Speedfax catalog for more information. Trip Unit Model 525 Thermal magnetic trip units, model 525 I n Trip unit rating I i Nominal instantaneous trip (amps) adjustable range (amps) 100 625 750 875 1000 1125 1250 110 800 960 1120 1280 1440 1600 125 800 960 1120 1280 1440 1600 150 800 960 1120 1280 1440 1600 175 1000 1200 1400 1600 1800 2000 200 1000 1200 1400 1600 1800 2000 225 1250 1500 1750 2000 2250 2500 250 1250 1500 1750 2000 2250 2500 960 I i 1120 AMPS 1280 1440 800 1600 Trip Unit Model 545 Electronic trip units, Model 545 with LI (Trip unit type N) or LIG (Trip unit type X) Trip Functions I n = 150A 40º C TM ~ TRIP UNIT/DISPARADOR 525 Trip unit model 525 Type / Tipo CDT3 100 40 40 45 50 60 63 70 80 90 100 150 60 60 63 70 80 90 100 110 125 150 250 70 80 100 125 150 160 175 200 225 250 rating (amps) t r Long time delay switch settings (seconds) Pt @ 6 x I r 100, 150, 200 2.5 4 6 8 10 14 17 20 25 30 rating (amps) I i Nominal instantaneous trip switch settings (amps) 100 125 150 200 300 400 500 600 800 1000 1100 150 187 225 300 450 600 750 900 1200 1500 1650 250 312 375 500 750 1000 1250 1500 2000 2500 2750 Fixed settings (LIG only) rating (amps) I g Ground fault pickup (amps) t g Ground fault delay 100 80.07 sec 150 120.07 sec 250 200.07 sec Trip unit model 545 15

Trip Unit Model 545 (continued) Electronic trip units, Model 545 with LSI (Trip unit type P) or LSIG (Trip unit type U) Trip Functions 100 40 40 45 50 60 63 70 80 90 100 150 60 60 63 70 80 90 100 110 125 150 250 70 80 100 125 150 160 175 200 225 250 rating (amps) I sd Short time pick-up switch settings (amps) x I r 100, 150, 250 1.5 2 2.5 3 4 5 6 7 8 10 rating (amps) t sd Short time delay switch settings (seconds) @ 8xl r 100, 150, 250 0 0.1, I 2 t OFF 0.2, I 2 t OFF 0.3, I 2 t OFF 0.4, I 2 t OFF 0.5, I 2 t OFF 0.1, I 2 t ON 0.2, I 2 t ON 0.3, I 2 t ON 0.4, I 2 t ON Fixed settings rating (amps) t r Long time delay I i Nominal instantaneous trip I g Ground fault pick-up (LSIG only) t g Ground fault delay (LSIG only) 100 1100A 80A.07 sec. 150 10 sec. (I 2 t @ 6 x I r ) 1650A 120A.07 sec 250 2750A 200A.07 sec Trip Unit Model 555 Switch 4 Electronic trip units, Model 555 with LI (Trip unit type R) or LIG (Trip unit type W) Trip Functions Switch 4 (LIG Only) 100 40 45 50 55 60 63 70 80 90 100 150 60 63 70 75 80 90 100 110 125 150 250 70 80 100 125 150 160 175 200 225 250 rating (amps) t r Long time delay switch settings (seconds) I 2 t @ 6 x I r 100, 150, 250 2.5 4 6 8 10 14 17 20 25 30 I n - Trip unit rating (amps) I i - Nominal instantaneous trip switch settings (amps) 100 125 150 200 300 400 500 600 800 1000 1100 150 187 225 300 450 600 750 900 1200 1500 1650 250 312 375 500 750 1000 1250 1500 2000 2500 2750 rating (amps) I g - Ground fault pick-up switch settings (amps) 100 80 40 40 40 60 60 60 100 100 100 150 120 60 60 60 90 90 90 150 150 150 250 200 100 100 100 150 150 150 250 250 250 rating (amps) t g Ground fault delay switch settings (seconds) 100, 150, 250 0.07 0.10 0.20 0.30 0.10 0.20 0.30 0.10 0.20 0.30 16

Trip Unit Model 555 (continued) Switch 4 Electronic trip unit, Model 555 with LSI (Trip unit type T) Trip Functions Switch 4 100 40 50 60 80 100 40 50 60 80 100 150 70 80 100 125 150 70 80 100 125 150 250 125 150 200 225 250 125 150 200 225 250 rating (amps) t r Long time delay switch settings (seconds) I 2 t @ 6 x I r 100, 150, 250 4 4 4 4 4 14 14 14 14 14 rating (amps) I sd Short time pick-up switch settings (amps) x I r 100, 150, 250 1.5 2 2.5 3 4 5 6 7 8 10 rating (amps) t sd Short time delay switch settings (seconds) 100, 150, 250 0 0.1, I 2 t OFF 0.2, I 2 t OFF 0.3, I 2 t OFF 0.4, I 2 t OFF 0.5, I 2 t OFF 0.1, I 2 t ON 0.2, I 2 t ON 0.3, I 2 t ON 0.4, I 2 t ON rating (amps) I i Nominal instantaneous trip switch settings (amps) 100 125 150 200 300 400 500 600 800 1000 1100 150 187 225 300 450 600 750 900 1200 1500 1650 250 312 375 500 750 1000 1250 1500 2000 2500 2750 Electronic trip unit, Model 555 with LSIG (Trip unit type V) Trip Functions Switch 4 100 40 50 60 80 100 40 50 60 80 100 150 70 80 100 125 150 70 80 100 125 150 250 125 150 200 225 250 125 150 200 225 250 rating (amps) t r Long time delay switch settings (seconds) I 2 t @ 6 x I r 100, 150, 250 4 4 4 4 4 14 14 14 14 14 rating (amps) I sd Short time pick-up switch settings (amps) x l r 100, 150, 250 1.5 2 2.5 3 4 5 6 7 8 10 rating (amps) I i Nominal instantaneous trip switch settings (amps) x l n 100, 150, 250 5 5 5 5 5 11 11 11 11 11 rating (amps) t sd Short time delay switch settings (seconds) 60, 100, 150 0 0.1, I 2 t OFF 0.2, I 2 t OFF 0.3, I 2 t OFF 0.4, I 2 t OFF 0.5, I 2 t OFF 0.1, I 2 t ON 0.2, I 2 t ON 0.3, I 2 t ON 0.4, I 2 t ON rating (amps) I g Ground fault pick-up switch settings (amps) 100 80 40 40 40 60 60 60 100 100 100 150 120 60 60 60 90 90 90 150 150 150 250 200 100 100 100 150 150 150 250 250 250 rating (amps) t g Ground fault delay switch settings (seconds) 60, 100, 150 0.07 0.10 0.20 0.30 0.10 0.20 0.30 0.10 0.20 0.30 17

Trip Unit Model 576 and 586 X3 440JM ESC Electronic trip units with LCD Model 576 (Trip unit type D and E) or Model 586 (Trip unit type A, G and K) I n Trip unit rating (amps) Trip unit model 576 Trip unit model 586 I r Continuous amps range a t r Long time delay settings (I 2 t @ 6 x I r ) Motor circuit protectors Amp I i Nominal instantaneous trip rating adjustable range (amps) 250 60-1200 a 250 1000-2000 b 250 1750-3500 c a Settings adjustable in increments of 120 amps. b Settings adjustable in increments of 200 amps. c Settings adjustable in increments of 350 amps. 600 V DC circuit breakers Amp rating Short-circuit rating 600 V DC 100, 150, 250 42 ka I sd Short time pick-up range t sd Short time delay settings Ii Nominal instantaneous trip range ab 125-1100A 100 40-100 2.5, 4, 6, 8, 10, 14, 0.1, 0.2, 0.3, 0.4, 0.5 sec. 150 60-150 1.25-10 x I 17, 20, 25, 30 sec. r 187-1650A or I 2 t @ 8 x I 250 70-250 r 313-2750A rating (amps) I g Ground fault pick-up range a 100 40-100A 150 60-150A 250 100-250A t g Ground fault delay Pre-alarm indication 0.1, 0.2, 0.3, 0.4, 0.5 sec. 80-100% I2t @.5 x I n x I r (Amps) a Current settings are adjustable in 1-amp increments. b Model 586, can turn function OFF. Instantaneous trip override function will be enabled to ensure self protection of circuit breaker. Molded case switch Amp rating Self-protective instantaneous override Short-circuit current rating 480 V AC a 250 3500A 65 ka 250 3500A 100 ka a Max. available current when protected by an appropriate overcurrent protective device. 18

Terminal Connectors Wire range Cables per connectors Wire size Torque Ib-in. (Nm) Catalog number #3 350 kcmil 1 (Cu only) #3 350 220 (25) 3TW1FG350 #4 350 kcmil 1 (Cu / Al) #4 350 kcmil 1 (Cu only) #4 #3 #1 1/0 350 #4 #3 #1 1/0 350 150 (16.95) 200 (22.60) 275 (31.07) 150 (16.95) 200 (22.60) 275 (31.07) 3TAW1FG350 b 3TCW1FG350 Compression connector kits #6 350 1 (Cu / Al) 3CLF350 Distribution connector kits #14 2/0 3 (Cu only) #14 #8 #6 2/0 40 (4.52) 120 (13.5) 3TA3FG20 #14 #4 6 (Cu only) #14 #4 35 (3.95) 3TA6FG04 a Packaged as 3 connectors. b Standard connectors when an L suffix is used on an assembled breaker catalog number. Internal accessories Auxiliary and alarm switch kits Description Mounting pocket Catalog number 1 Alarm switch 1 A/B a bases AMBL2 and AMBL3 Left, rightb ASKL1 2 Aux. switches 1A + 1B base AMBL1 Left, right ASKL2 2 Aux. + 1 Alarm switch 1A + 1B, 1A/B bases a AMBL2 and AMBL3 Left, right b ASKL3 a Includes 1A and 1B contact for alarm purposes, only one of which may be installed at any time. b Kit includes 2 bases - one for mounting switches in left pocket and another for mounting in right pocket. Auxiliary and alarm switch mounting base only Description Mounting pocket Catalog number For 2 Aux + 1 Alarm Left AMBL2 For 2 Aux + 1 Alarm Right AMBL3 For 3 Aux Left, right AMBL1 Shunt trip Control voltage Catalog number 48 60 VAC STRLM60 110 127 VAC STRLN120 208 277 VAC STRLS277 380 600 VAC STRLV600 24 VDC STRLB24DC 48 60 VDC STRLC60DC 110 127 VDC STRLD125DC 220 250 VDC STRLE250DC Shunt trips or UVR s may be mounted in the Right Pocket only. Internal accessory locations Left accessory pocket Right accessory pocket Up to 3 auxiliary switches Shunt trip or UVR or up to 3 auxiliary switches Up to 2 auxiliary switches + 1 alarm switch Maximum of 6 switches total. Maximum of 2 alarm switches, 1 Left + 1 Right Pocket. Shunt trip or UVR or up to 2 auxiliary switches + 1 alarm switch Auxiliary / Alarm switches only (requires a base) Description Catalog number 1 NO (normally open contact) ASWPA 1 NC (normally closed contact) ASWPB (A) Normally open contacts are open when the breaker contacts are open. (B) Normally closed contacts are closed when the breaker contacts are open. Undervoltage release Control voltage Catalog number 110 127 VAC UVRLN120 220 250 VAC UVRLR240 208 VAC UVRLP208 277 VAC UVRLS277 380 425 VAC UVRLT415 440 480 VAC UVRLU480 12 VDC UVRLA12DC 24 VDC UVRLB24DC 48 VDC UVRLC48DC 60 VDC UVRLG60DC 110 127 VDC UVRLD125DC 220 250 VDC UVRLE250DC 19

X X.22 [5.5] 1.375 [35] 1.375 [35].09 [2.5] (150A).16 [1.3] (250A) 4.19 [106.5] 3.56 [90.5] 3.20 [81.5].75 [19].69 [17.5] (3P) 6X ø.33 [ø8.5] 2.06 [52.5] 2.50 [63.5] 4.11 [104.5] (3P) 1.25 [32].62 [16] NFT00773a 7.31 [185.5].22 [5.5] 3.49 [88.5] 5.86 [149] 2.98 [75.5] 4.74 [120.5] 2.28 [58] 5.17 [131.5].76 [19.5] 2.55 [65] Y 1.25 [31.5].75 [19].16 [4].69 [17.5] (3P) 2X ø.22 [ø5.5] (3P) Y Y X Dimensions (complete breaker) Shipping weight, lbs. (kg) Frame Trip unit Complete Poles only Thermal-mag Electronic breaker 2,3 3.45 (1.56) 1.35 (.62) 1.60 (.72) 6.2 (2.8) Permissible mounting positions 90 90 30 30 20