EVD-ice FOR PS SERIES

Similar documents
EX3: stepper motor valve with safety embedded solenoid ON/OFF valve

19,1 261,0 kw COOLING 23,7 333,0 kw HEATING

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

Mini Vehicle Controller (MVC)

Copeland Scroll Indoor Condensing Units for Refrigeration

VTZ variable speed Reciprocating compressors

User manual. EVD evolution twin. Driver for 2 electronic expansion valves. Integrated Control Solutions & Energy Savings READ CAREFULLY IN THE TEXT!

RECU-NOVO. heat recovery unit

ENR Incorporating

technical catalogue tetris KW Chiller and heat pumps air/water

REPLACEMENT PARTS MANUAL

Kirby Polar Pack Series III Outdoor Condensing Units

User manual. Standard Modular Chiller HP 1/8 compressors with CAREL driver Application program for pco 1, pco 2, pco 3, pco C and pco XS.

50Hz ZBD45KCE-TFD R404A Dew Point

OEZ IEZ NOMENCLATURE STANDARD FEATURES FACTORY INSTALLED OPTIONS

Application Engineering Europe

EVD evolution twin Driver for 2 electronic expansion valves

Semi-hermetic reciprocating compressors

CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

Thermo -Expansion Valves Series TX7

TV-Line Condensing Units

LSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS

Inverter scroll compressors VZH single and manifold

PEDESTAL PLUG FANS FPP SERIES, HIGH EFFICIENCY CATALOGUE

Improves fan ef ciency

VENCO. Instruktions MANUAL. typ: pco LAN PERFORMO SWN. TPi Klimatimport AB Tel: Fax:

Thermostatic Expansion Valve

NECS-WQ. Climaveneta Technical Bulletin NECS_WQ_0152_1604_201006_GB. INTEGRA unit for 4-pipe systems, water source ,6-522 kw

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw

AZURA. Air/water multifunctional chiller&heat pump, kw

Reciprocating Compressors AIRBOX / AIRBOX CENTER

Model H30 Operation Manual

SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS

30-450kW. Now Available. Ultima Compact Chiller Range kW. > Ultima Compact Chiller Range. Free-Cooling models up to 450kW.

CWP-CO / CWP-RC / CWP-HP 02 to 35

Sporlan ispeed TM Inverter Series. Drive Systems for Refrigeration Compressors, Condenser Fans and Pumps BULLETIN ME

Immersion chillers E 01

Product Catalog. NQ Series. Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons

Semi-Hermetic Condensing Units KL

UMXCA/UMXCBA ECVA/ECVBA

Bitzer Friga Pack Catalogue

AHN 064 to 304 EHN/CHN 064 to 304

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432K VRF HEAT PUMP

Electrical Control Valves

Crankcase pressure regulator Type KVL

Digital Room Thermostats with Touch Screen LCD

Hot gas bypass regulator type CPCE Liquid gas mixer type LG (accessory)

Accessories. Series REC

Remote on/off switch Connector for remote on/off switch available on all models. DIP switch for 50/60Hz selection (48/350 model only)

Ultima Compact Chiller Range kW

Kirby WRC Remote Condenser. With HyBlade EC Fans and AxiTop Diffuser

Optyma TM Slim Pack Just mount, braze and plug

DRAFT. Technical Data OPA Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

WQL/WQH/WQRC 524 to 1204

LOW AIR / DUAL THROW UNIT COOLER. EPC - High & Medium Temperature Application Capacity: 2.2kW to 19.2kW

Electronic suction modulating valves type KVS

kW. Ultima Screw Chiller Range kW. > Ultima Screw Chiller Range. Includes Ultima FreeCool Chiller Range

SANYO SCROLL COMPRESSORS

HYDROCIAT LW. Use. Range. Water-cooled chillers. Screw compressors CIAT shell and tubes direct expansion evaporator HPS (High Power System) equipment

Top view. Illustrated Part List 3400 PCA 130/2 - CE Recommended Spare parts list rev. B. A11 VFD without fan (572315) M2 Centrifugal Fan (VN0310)

Chiller. SWS/SWR 1602 to Water Cooled Chillers Cooling Only and Condenserless Versions Engineering Data Manual.

Variable speed application guidelines

YOSHI AWS D3 YoshiAirWaterSystem

ZF Copeland Scroll Compressor Range for Low Temperature Refrigeration using R407A/F, R448A/R449A and R404A

Solutions for Cooling Professionals. Price Catalogue 2011 Cooling Components.

Kirby Centurion Condensing Unit

Crankcase pressure regulator Type KVL

EMERSON CLIMATE TECHNOLOGIES-EX

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw

ECONOMY CYCLE. Rooftop Packaged Air Conditioners with Economy Cycle. Economy Cycle Rooftop Packaged Air Conditioners

FULL DC INVERTER SYSTEMS INDIVIDUAL AND MODULAR CONSTRUCTION FLEXIBLE COMBINATIONS AIR CONDITIONING COMMERCIAL AIR CONDITIONERS SDV4 2014

CPU-95 ADVANCED DIGITAL IGNITION SYSTEM FOR INDUSTRIAL ENGINES

Tecumseh Semi Hermetic Condensing Units

MARATHON SLA SERIES CAST ALUMINIUM MULTI-MOUNT THREE PHASE MOTORS SIZES , KW

USER MANUAL DCA15. Auto Aır Conditioner Controller Unit. Elektrosan Elektronik Müh. San. Ve Tic. Ltd. ENG. DCA15 V01 03/17

00% Optyma Plus TM New Generation Plug and play solution. Catalogue. R404A/R507, R134a MAKING MODERN LIVING POSSIBLE.

MATRIX LLC LEVEL CONTROL PANEL

MARATHON HLA SERIES HLA CAST ALUMINIUM MULTI-MOUNT THREE PHASE MOTORS SIZES , KW

Progress all along the line

Three Phase UPS Systems Range: 10 to 500kVA

Air-Cooled Liquid Chiller with integrated hydraulic module

HYDROCIAT LW R134a. Water cooled chillers USE RANGE

Air Cooled CAPACITY: TR CHILLER PRODUCT DATA BOOK

SMT-AZC INSTALLATION / OPERATION MANUAL

Low Air Process Room. Chiller Series. EPC - High & Medium Temperature Application Capacity: 2.2kW to 19.2kW

RANGE. STD Version (Standard): HEE Version (High Energy Efficiency): OPERATION LIMITS. Series LP 46ºC 12ºC 18ºC 5ºC

Reciprocating Compressors AIRBOX / AIRBOX CENTER

Electrical Control Valves Series EX4, EX5, EX6, EX7 & EX8

GEA Bock 6 and 8 Cylinder Compressors HG76e and HG88e

COMMISSIONING Tick the tests carried out by attendee.

Air Cooled Packaged Units Technical Data

Proudly 100% Australian Owned Manufacturers & Distributors of Variable Speed Drives & Soft Starters ECODRIVE Solar Variable Speed Drive

Crankcase pressure regulator Type KVL

Total and partial heat recovery RANGE. AQUACIAT power LD series. AQUACIAT power LDC - LDH series. AQUACIAT power ILD series

CS Series Condensing Units

Transcription:

THE PERFECT COMBINATION EVD-ice FOR PS SERIES EVD-ice Electronic Valve Driver Technology World First: PS Series fitted with EVD-ice HX-514-2 AUS

THE PERFECT COMBINATION FROM HOT TO COLD. RUNNING EFFICIENTLY THROUGHOUT THE YEAR. BOTTLE SHOP EVOLUTION SERIES PS SERIES WITH EVD-ice

PS SERIES & EVD-ice THE PERFECT COMBINATION The BUFFALO TRIDENT PS Series Evaporator factory fitted with EVD-ice superheat control provides the contractor with a plug and play package. Factory fitting the EEV driver, Ultracap and pre-wiring to all components including fans, removes on site costs for parts & labour. In many installations, a liquid line solenoid is no longer required as the EVD-ice will regulate the EEV with an on/off signal from the room temperature control. In the event of a power failure the Ultracap will discharge power to the EEV coil and drive the valve closed, preventing floodback to the refrigeration plant. Commissioning costs are reduced with the factory programmed control (adjustment can be made on site), and the proven accuracy and performance of the EVD-ice provides a reduction in pull down time for room temperature and product, resulting in energy savings for the end user. SYSTEM BENEFITS Ease of installation: EVD-ice can be connected easily to a cold room thermostat for regulation on / off signal and alarm (available on next release of Ultracella control). EVD-ice can also be connected to a supervisory system for monitoring (real time operating conditions, alarms, messages). Easy commissioning: Quick and easy start up with two parameters. Thanks to the user friendly interface the installer can easily set refrigerant type and electronic superheat (ktd) (avoiding recalibration). Advanced commissioning is available in a second level menu (MOP, LOP etc). Ultracap module: The Ultracap will discharge when power is lost driving the EEV closed. The Ultracap module is totally sealed thanks to overmolding technology. It is simple to fix onto and connect to the EVD-ice, and can be connected through IP65 connectors to the EVD-ice compatible model. The new Ultracap module integrates high tech capacitors and an integrated intelligent charging process enhancing the capacitors life time and power back-up reliability. THE SPECIFIC FEATURES INCLUDE: // Fast commissioning: user friendly interface for fast setup on site, or RS485 serial communication available for advanced settings supervisory systems (Modbus protocol) // IP65 rated thanks to overmolding plastic technology. The electronic board is completely sealed, including sensors and cable connectors. Operating condition: -30 C to 40 C // Integrated package design to operate in cold storage applications // Internal power supply 230V / 115V - no additional transformer to power on the electronic driver // Software features based on Carel EVD evo: all Carel experience in EEV regulation inside // Compatible with a number of refrigerants including: R22, R134a, R404A R407A, R407C, R407F R410A, R417A, R422A, R422D R423A, R427A, R245Fa R507A PLUG & PLAY SOLUTION 3 HX-514-2 AUS

ENERGY SAVING COMPARATIVE TEST: EEV vs TEV A field test was set up to analyse the operational performance between an EEV and TEV. The below diagram indicates the installation. The system automatically switches from EEV to TEV each 3 days. Energy consumption (kwh) is measured in both cases considering all cold room loads. The below graph provides the results. Application: Low temperature cold room 90m 3 for meat storage (set -20 C) Evaporator: 5.5kW, heater defrost 3PH 5kW, 4 fans 200W 1PH Condensing unit: 5.5kW Refrigerant: R404a S1 Solenoid valve EEV EEV Evaporator Cold room P Refrigerant > S2 Solenoid valve TEV TEV T > Thanks to EEV, compressor duty cycle on time is lower - this means an effective energy saving for the system. // Food quality maintained thanks to extremely short temperature pull down times // Optimal evaporator efficiency thanks to precise refrigerant flow control // Ultimate energy saving with EEV, floating suction and condensing pressure ENERGY SAVING RESULTS European winter (November 2014 > February 2015) TEV > 6800KWh EEV > 4900KWh Saved 1900 kwh One year energy saving (summer / winter) from 15% to 20% HX-514-2 AUS 4

EVD-ice SYSTEM Integrated package design to operate in cold storage applications: PS Series Evaporator EVD-ice electronic valve driver Complementary components: E2V E3V bodies Pressure sensor FAST FIELD COMISSIONING WITH SIMPLE 2 STEP SETUP Thanks to the user friendly interface the installer can easily set refrigerant type and superheat. Press & hold button to enter program. Press and to scroll through menu, and to select. 1. Refrigerant type Compatible with most widely used HFC, HC refrigerants (up to 22 options). 2. Superheat (ktd) Exact setpoint entered, avoiding (re)calibration or adjustment, improving comissioning and operation. Advanced commissioning is available in a second level menu (MOP, LOP etc). Ultracap module EVD-ice ELECTRONIC CONTROL SYSTEM Component Specifications Power supply 230V / 115V Power consumption 9W Emergency Power Supply 22Vdc+/-5% (If the optional EVD*** model is installed) Motor connection 5-wire cable, CAREL P/N E2VCABS*** Lmax = 0.5m On / Off Input Connection High voltage digital input (230V / 115V); Closing current 5mA, Lmax< 20m Low temperature NTC: Probe S1 10kΩ at 25 C in range -50 C to 90 C meas. error: 1 C in range -50 C to 50ºC, 3 C in range +50 C to 90 C RS485 Serial Connection Lmax = 1000m, shielded cable Operating Conditions -30 C to 40 C Ingress Protection IP65 HX-514-2 AUS 5

BITZER Australia Pty Limited 134 Dunheved Circuit, St Marys, NSW 2760 Australia tel +61 (2) 8801 9300 fax +61 (2) 9673 4698 info@bitzer.com.au Victoria tel +61 (3) 8326 8200 fax +61 (3) 9310 2520 Queensland tel +61 (7) 3725 1360 fax +61 (7) 3274 3621 South Australia tel +61 (8) 8345 6110 fax +61 (8) 8268 4555 Western Australia tel +61 (8) 6350 6297 fax +61 (8) 9359 2077 BITZER New Zealand BITZER Australia Pty Ltd 9a Douglas Alexander Parade Rosedale 0632 Auckland New Zealand tel +64 9 415 2030 www.bitzer.com.au info@bitzer.com.au In the interest of continuous improvement BITZER reserves the right to change the specifications or design of any of its products without notice. The BITZER Symbol, Name BITZER and model numbers are registered trade marks. All products manufactured are pending design and specification registration and must not be copied or duplicated in any way. Note: The ISO standard only applies to the BITZER NSW and VIC branches Quality ISO 9001 03.2016