Maximum 20 ma, 24 VDC 825 ohms (see section 3.3) Supply voltage dependence

Similar documents
7007 Loop Mate 2 Loop / Voltage / Current Simulator

Time Electronics DC Voltage Calibrator. Technical Manual

PRODUCT / TEST MANUAL 2C58K2 INSTANTANEOUS OVERCURRENT

P200 P/I Transducer. Installation, Operation, and Maintenance Instructions INTRODUCTION

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (0-10VDC Input Version)

Carbon Monoxide Transmitter

GS-AQ1000 VOC Indoor Air Quality Sensors

534HS Pressure Transmitter

PRODUCT/TEST MANUAL 2C58K37 INSTANTANEOUS OVERCURRENT RELAY

GE Sensing & Inspection Technologies

Chapter Page. 1 Introduction Description 1

MODEL AMMONIA GAS SENSOR MODULE 4-20 ma

User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator

TD1512AX Technical Data. REMOTE MOUNT SOLENOID DRIVER (4-20mA Input Version)

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

3000RS PRECISION RESISTANCE STANDARD 3000 PRECISION SERIES LABORATORY REFERENCE STANDARDS

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

PEAKTRONICS DMC-101 ADDITIONAL FEATURES. DC Motor Controller, 5A DMC-101

Damper Actuator Installation

LTX RF LEVEL SENSOR. Instruction Manual

WARNING! READ BEFORE INSTALLATION

TABLE OF CONTENTS. 8.3 Online Sensor Specifications. Series TS (Models TS1, TSP, TSH, TSL,TSF, TSB1, TSB2) According to Electromatic factory procedure

Tension Control Unit Type Product Manual EUROTHERM DRIVES. Copyright Eurotherm Drives Limited Printed in England HA Issue 3

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

FS5 Thermal Mass Flow Sensor For various gas flow applications

CN0055 & CN0055B DC to DC NEGATIVE RESISTANCE SPEED CONTROL

REMOTE MOUNT SOLENOID DRIVER (0-5 VDC/0-20 ma/10k Potentiometer Input)

PLATINUM SERIES SWITCHBOARD METERS

MM1/MM2 INSTALLATION & MAINTENANCE INSTRUCTIONS

Type 500X. Electropneumatic Transducer (I/P, E/P) Installation, Operation and Maintenance Instructions. Ordering Information.

Differential Pressure Transmitter

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved

Continental Hydraulics Installation Manual CEM-AA-A

Excellence in Level Measurement

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

Manual Installation & Operation

FC/FCA 12, 24, 32 & 48 VOLT, 6 & 10 AMP BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

Design Considerations for Pressure Sensing Integration

INSTRUCTION MANUAL 272-5X5 ANALOG TRANSMITTER (210 SERIES FLOW METERS) 272-5X7 ANALOG TRANSMITTER (220/240 SERIES FLOW METERS)

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

Model DS1000/DT20 System

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

FEATURES AND BENEFITS

CB-005N Circuit Board

TIME OF FLIGHT Components from:

5001TCP SPEED CONTROLLER

Series 20 Installation Instructions

5001TCP SPEED CONTROLLER

POWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc.

Weatherproof Tubular Slip Ring Assembly

RP-4000 Reserve Power Control

********SERVICE MANUAL********* MODELS:

SR1V. Industrial Low Cost String Pot

Time Electronics DC Multifunction Voltage/Current/Resistance Calibrator. Technical Manual

VOC Duct and Rough Service Sensor

CP (Vdc) CP (Milliamp) CP (Slidewire)

Ultrasonic Sensor U-B

Figure 1: WPR2 Dimensions and Hardware

How to Implement xdrive Designs

Micro H 2 Meter Service Manual H 2

MODEL 905V OPERATING INSTRUCTIONS

TIME OF FLIGHT Components from:

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM

MODEL ITMA - INTELLIGENT THERMOCOUPLE MODULE WITH ANALOG OUTPUT

MODEL IRMA - INTELLIGENT RTD MODULE WITH ANALOG OUTPUT

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

SCHNITZ MOTORSPORTS PNC-202, 2-STAGE PROGRESSIVE NITROUS CONTROLLER USER MANUAL AND INSTALLATION GUIDE NOS PULSE FREQUENCY

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

Application Note Thermal Mass Flow Sensor FS7

PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL USA From outside US: +1 Tel: (561) Fax: (561)

MODEL 901 OPERATING INSTRUCTIONS

Mini Pressure Transmitter HA7

Voltmeter. for Experiments with the fischertechnik Expansion Kit. Order No

GF1900 SULFURYL FLUORIDE MONITOR

User's Manual O

Chapter 9 Basic meters

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved

USER'S MANUAL MODEL DPS32PG1 DRIVER PACK

VSO Thermally Compensated Proportional Valve

Pressure sensor with built-in amplification and temperature compensation circuit

SMART VALVE POSITIONER 4 to 20 ma + HART Digital Communication. smar B87

Data Sheet for Precision Potentiometer

Miniature Proportional Valve Thermally Compensated Proportional Valve. Physical Properties

Conversion of a Turnigy 9X to Hall effect sensors

INSTRUCTION MANUAL 276-5XX SERIES 4-20MA TRANSMITTERS

TEGAM HTRHSERIES. High Temperature, Relative Humidity/ Temperature Probe Transmitter

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

UNIVERSAL CALIBRATOR M

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

Global Water Instrumentation, Inc.

AVR Hybrid Universal Analog Digital Voltage Regulator Operation Manual

m WARNING! READ m BEFORE INSTALLATION

THUNDERBIRD. Agricultural Weighing Systems SS1000 Instructions

24P Installation and Operations Manual

10260 Retrofit to 10260A Non-Contact Sensor Instructions Kits through -512

MDC V, 30A Brushless Controller. User s Guide L East Orangefair Lane, Anaheim, CA

1100 Series Piston Type Differential Pressure Gauges

Model 124 Filter Minder & Model 124

Harris IRT Enterprises Digital Resistance Tester Model XP

Transcription:

ALPHASENSE USER MANUAL Page 1 4-20mA Transmitter for Oxygen Sensors 072-0126 Issue 2 1 INTRODUCTION The Transmitter PCB includes circuitry for an electrochemical oxygen sensor to convert the µa output signal from the sensor to a 2-wire 4-20mA signal. The transmitter board is shipped with four mounting pillars and hardware that may be used if required Alphasense 4-20 ma transmitters offer convenience and easy maintenance for gas sensors: Transmitters are shipped pre-calibrated for immediate use. Circuitry includes onboard voltage regulator and uses low power two-wire transmitter systems, allowing the simplest wiring format. Small circuit board size allows smaller sensor housing. Conformally coated circuit board gives environmental protection of circuit. Low power circuitry with excellent performance means no degradation of sensor performance due to electronics. Close PCB tracking and buffer circuit reduces noise pick-up and RFI/EMI susceptibility. Besides periodic sensor re-calibration, the transmitter electronics require no maintenance throughout the lifetime of the sensor. The sensor can be replaced at the end of the twoyear sensor working life. Re-calibration is required when the sensor is changed. See section 7. Please read these instructions to ensure correct installation, use and calibration of your gas sensor/ transmitter. 2.1 Transmitter Specification Input Voltage Required +7.5 to + 35 VDC Output at 15% oxygen concentration 4mA Output at 20.9% oxygen (ambient) 13.44 ma Output at 25% oxygen concentration 20mA Setability / stability <0.1mA (<0.5% FS) Maximum load @ 20 ma, 24 VDC 825 ohms (see section 3.3) Supply voltage dependence < ±0.2% output from +7.5 to +35 VDC Connector on PCB 2 pin Molex plug (ref. 22-27-2021) PCB current requirement <100 µa PCB dimensions 39mm x 39mm x 19 mm (height) Operating conditions See sensor specification (90%rh maximum) Calibration (shipped pre-calibrated) multi-turn zero and span potentiometers Power supply protection Diode protection for voltage regulator

072-0126 Iss 2 Page 2 2.2 Range/Options Sensor and transmitter boards are shipped from Alphasense pre-calibrated. You may wish to confirm calibration. Standard available range is listed below: Sensor Oxygen Concentration Range (%) O2-A2 15 to 25 Table 1. Oxygen Transmitter ranges Although the sensor and transmitter are pre-calibrated and the ranges are preset, it is possible to modify the range by adjusting the zero and gain potentiometers, which changes the circuit gain and offset. Contact Alphasense before proceeding. 3 Set Up Oxygen sensors are packed separate from the transmitter board to prevent loss of lifetime during shipping and storage. The sensor and transmitter are matched, so to reconnect the sensor and transmitter board: 1 Remove the oxygen sensor from the clear bag. 2 Plug the sensor into the board. 3 Wait one hour for the sensor to stabilise before checking that the output in ambient air is 13.3 to 13.6mA. 3.1 Mechanical Mounting Transmitters should be mounted to your housing using the pillars provided. These pillars should first be attached to the PCB using the supplied screws and washers. (Important note: Ensure that a washer is fitted on BOTH sides of the PCB see figure 3). Two sets of mounting holes are provided so that the assembly can be fixed to either the housing top, (using the locating holes in the corner of the PCB), or to the base of the housing, (using either set of locating holes Note: Long pillars will be required for this configuration, Alphasense Pt No: 034-0005-00). Figure 1 below shows mounting hole locations (dimensions are in mm). Figure 2 diagrams the locating holes; normally the outer holes are used for mounting, while the inner holes are in the same location as the earlier issue of this PCB, allowing backward compatibility with the earlier PCB design. 14.7 Ø3.20 32 39 19.5 32 39 Figure 1. Mounting hole locations. Figure 2. Inner and outer mounting holes. 072-0126 Iss 2 Page 3

The pillars are tapped to accept an M3 screw. We recommend a screw length that is at least 8mm to ensure rigid fixing. It is good practice to hold the pillar when screwing into the pillars to stop the pillar from rotating on the PCB. It may be easier to remove the sensor whilst screwing the circuit board pillars to your housing. If you move the pillars, ensure that, if mounting to the lid of your housing that you include the washer between the pillar and PCB to ensure correct height of the pillar assembly. See figure 3. Allow 60 minutes after plugging the sensor back into the board for the output to stabilise before calibrating or checking performance. M3 Zero adjust M3 Span adjust Connector Screw Washers Pillar Span Pot Connector Zero Pot Figure 3. Mounting pillar configuration for Figure 4. Mounting pillar configuration for attaching to the lid of an enclosure. attaching to the base of an enclosure. (Long pillars required Pt: No 034-0005-00) Figure 5. Side view of mounting to lid of an enclosure. Figure 6. Side view of mounting to the base of an enclosure. 16.5 20 M3 Pillars Washers MUST be fitted both sides 072-0126 Iss 2 Page 4 3.2 Connection and Wiring

Power to the transmitter board is via a Molex 2-pin mini plug (type 22-27-2021: supplied with the transmitter). Connect using a screened, two-core cable to the wires (black is ground, red is positive) by either soldering or using a screw terminal block. These leads can be shortened or extended as needed. 3.3 Power Supply Your power supply must be between 7.5 and 35 VDC with less than 0.2V ripple. Do not supply mains AC power to this unit: this will destroy the transmitter and void the warranty. The transmitter is protected against incorrect polarity, but will not function if you have reversed the power supply wires by connecting the Molex plug incorrectly to the transmitter board socket. When selecting the power supply voltage, you must not exceed the maximum total loop resistance, which includes your measuring resistor used to change the 4-20 ma current into a measured voltage. The transmitter requires a minimum of 7.5 volts to operate; therefore, the maximum potential drop allowed across your sensing resistor and cable is: (power supply voltage) -(7.5V) Assuming full-scale deflection at 20 ma, use Ohm's law to calculate the maximum loop (cable plus sensing resistor) allowed resistance. 4 Correct Usage and Maintenance Ensure that there is a good gas seal between the sensor and the housing; also if the sample is pumped, then ensure that the flow rate is sufficient. Alternatively, the sample gas can be allowed to diffuse to the front face of the sensor. Alphasense recommends 250 to 500 standard cubic centimetres per minute (sccm) flow rate if pumped. Higher flow rates may be used, but beware that pulsing flow and higher-pressure drops may lead to erratic readings. No maintenance is required, but if the top dust/ oil filter has become badly contaminated, then contact Alphasense for replacement dust filter. See table 2 below. Part Number Description 024-0023-00 Self-adhesive dust/oil filter 010-0178-00 Cable assembly 034-0005-00 20mm long Spacer Table 2. Replacement part numbers

072-0126 Iss 2 Page 5 5 Calibration The 4-20mA transmitter is shipped pre-calibrated to the range shown in 2.1. Periodic recalibration is required for all gas sensors, especially in safety-critical applications. Full calibration requires a nitrogen bottle and accurate blending equipment to generate 15% oxygen to set zero, but because the zero and span adjustments are interactive, we strongly recommend that the output is checked in ambient air (13.44mA) and if the output is less than 12.7mA or greater than 14.1mA, then re-calibration may be frustrating and we recommend that the transmitter board is returned to Alphasense and a new sensor will be fitted and re-calibrated. For small re-calibrations follow the instructions below. The transmitter and sensor were calibrated at 25 C. If the sensor will be constantly exposed to a temperature significantly different than 25 C, then allow the sensor to stabilise at that temperature, then recalibrate as explained below. To Recalibrate: 1 First ensure that the power supply is connected correctly. Ensure that the sensor has been powered for at least one hour before checking calibration. 2 Ambient air calibration Either pump or allow clean air to diffuse to the sensor for ten minutes. Adjust the zero potentiometer (RP2: see figure 3) with a small screwdriver until the reading is within ± 0.05 ma of the Air Calibration Point shown in Table 3. Sensor Full-scale % oxygen (20.9% oxygen) Air Calibration Point (ma) O2-A2 25 13.44 Table 3. 4-20 ma Transmitter Air Calibration Mass flow oxygen sensors are used in these transmitters. With low temperature and pressure dependence, these are well suited for fixed system applications. This type of oxygen sensor has a small non-linearity, which can normally be ignored. Table 4 below lists the output error (measured output actual concentration) due to non-linearity. % O 2 O2-A2 (15-25%O2 range) 15 0 20 0 25 +0.5 Table 4. Transmitter non-linearity

072-0126 Iss 2 Page 6 6 Warranty Transmitters are warranted for two years. Alphasense O2-A2 oxygen sensors are warranted for two years. If you have any difficulties or problems then contact: Customer Support Alphasense Limited Sensor Technology House 300 Avenue West Skyline 120 Great Notley Essex United Kingdom CM77 7AA Tel: +44 (0) 1376 556 700 Fax: + 44 (0) 1376 335 899 email: sensors@alphasense.com 7 Attachment Figure 7. Circuit diagram

αlphasense Ltd Sensor Technology House 300 Avenue West, Skyline 120, Great Notley, Essex, United Kingdom CM77 7AA Tel: +44 (0) 1376 556 7008 Fax: +44 (0) 1376 335 899 e-mail: sensors@alphasense.com web: www.alphasense.com