XENON POWER SUPPLY for 10 kw Britelight Lamphead

Similar documents
XENON POWER SUPPLY 4000 Watt Gladiator IV

XENON POWER SUPPLY Compact Model 220 Volt Equipment Type

XENON POWER SUPPLY Watt

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

XENON POWER SUPPLY 2000 Watt

XENON POWER SUPPLY Watt

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

ULTRA 80. Xenon Lamphouse STRONG INTERNATIONAL. Type 40001, Rev. 5/99

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

POWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc.

SUPER LUME-X Xenon Lamphouse

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

BL7000 SYSTEM OPERATING MANUAL

Yaskawa Electric America Unit Troubleshooting Manual Section One: Introduction & Checks Without Power GPD 506/P5 and GPD 515/G5 (0.

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

TS-E TURBO STEAM ELECTRIC COUNTERTOP CONVECTION STEAMER PARTS AND SERVICE MANUAL

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

2015 EDITION SUBMERSIBLE MOTORS AIM MANUAL. APPLICATION INSTALLATION MAINTENANCE 60 Hz, Single-Phase and Three-Phase Motors. franklinwater.

4000 SYSTEM OPERATING MANUAL

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

Assembly Instructions MP-P2 Power Supply and Chassis Base Plate

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

MINE CHARGER INSTALLATION AND OPERATION MANUAL MODEL NUMBERS: MSP MSQ MSR MSS

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

ST Charger. Industrial Battery Charger

BRIVIS DUCTED INVERTER SERVICE MANUAL DRCi

OWNER S MANUAL. Please read installation and operation instruction before using this Power inverter.

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

Power Distribution System User s Manual. Model: PDS-100

C.E. Niehoff & Co. N1601, N1602, N1603, and N1604 Alternator Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

P445 Series Electronic Lube Oil Control

Welcome to PTI--Photon Technology International--Optical Building Blocks!

CDBR-B. Instruction Manual. Dynamic Braking Unit. March 2013 Part Number: R4 Copyright 2013 Magnetek

STANDARD AND GROUND SWITCHED APPLICATIONS

MODEL ELC-12/60-D BATTERY CHARGER

CV - 6SL INSTRUCTION MANUAL 6000W POWER SUPPLY

C.E. Niehoff & Co. C703/C703A and C706 Alternators Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING.

Contents. DX Ignition Page 2

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

C.E. Niehoff & Co. C505, C527, C531, and C534 Alternators Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING

10000AR X2 INSTALLATION MANUAL

CDBR-B. Dynamic Braking Unit Instruction Manual. April 2009 Part Number: R1 Copyright 2009 Electromotive Systems

Application Engineering

TROUBLESHOOTING GENERATOR UNITS

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

BF Series Flasher Thermal flasher circuitry

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

INSTALLATION, OPERATION & MAINTENANCE SERIES ABC11B-120-XX BATTERY CHARGERS

INDEX Section Page Number Remarks

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Controlled Ferroresonant Ballast (CFB) Generation #3. Manual

User s Manual. Automatic Switch-Mode Battery Charger

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

G76x Direct Spark Ignition Controls

High Frequency SineWave Guardian TM

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

R & D SPECIALTIES ROTROL I USER'S MANUAL

Troubleshooting Manual

CONTROL FEATURES AVAILABLE OPTIONS

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

E.S.P. Embedded Sensing Probes for Motor Brushes

Application Engineering

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL

ELECTRONIC MANUAL VOLTAGE CONTROL Model: MVC 300. Part Number:

Contacts The moveable contact, which is the one affected by the armature is sometimes referred to as the hinge contact.

A1P OPERATING MANUAL

Northwest RV Supply Manual Compliments of Printed From TROUBLESHOOTING

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

XENON SUPER TROUPER Follow Spotlight

Optimal Series. Automatic Transfer Switch. Installation and User Manual for the OPT2225 Automatic Transfer Switch. Full Version

G600 Series Replacement Intermittent Pilot Ignition Controls

Manufacturing of: Vehicle Mounted Generators Hydraulic Generators

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator.

SE-3SCR-LM MANUAL MOTOR LOAD MANAGER

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

N1387 Series Troubleshooting Guide for N Alternators

ATD WATT INVERTER

G72x Series Direct Spark Ignition Controls

BURGLAR ALARM KIT MODEL K-23. Assembly and Instruction Manual ELENCO

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

ARC 1850 LIST OF FIGURES

Series 20 Installation Instructions

Electric Motor Controls BOMA Pre-Quiz

AIR COOLED RECTIFIER SPECIFICATION S-50-A

********SERVICE MANUAL********* MODELS:

LS/ CCS. Constant Current Charger

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

Troubleshooting Guide for N1225-1/N1237-1/N Alternators

LESTRONIC II BATTERY CHARGER TAYLOR-DUNN MODEL TYPE 24LC25-8ET

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation

PowerOhm Installation Manual for BM R Series Braking Modules

PRINTING LAMP ASSEMBLIES DOUTHITT. 245 ADAIR ST. DETROIT, MI or TOLL FREE AT DOUTHIT(T)

CDBR-D. Instruction Manual. Dynamic Braking Unit. May 2014 Part Number: R1 Copyright 2014 Magnetek

Transcription:

XENON POWER SUPPLY for 10 kw Britelight Lamphead Rev. June 2004 STRONG INTERNATIONAL a division of Ballantyne of Omaha, Inc. 4350 McKinley Street Omaha, Nebraska 68112 USA Tel 402/453-4444 Fax 402/453-7238 www.strongint.com

CONTENTS Page PREFACE... 1 INSTALLATION... 1 Tap Adjustment... 2 INSTALLATION DIAGRAM... 5 TROUBLESHOOTING... 6 MAINTENANCE... 9 WIRING DIAGRAM... 10 PARTS ILLUSTRATIONS Figure 1... 11 Figure 2... 13 Figure 3... 14

PREFACE THIS XENON POWER SUPPLY manufactured by Strong International is a dualchassis, high reactance 10,000 watt unit utilizing silicon diodes as the power conversion elements. All models are designed for 50/60 Hertz operation, and are available in varying AC input types, depending upon the configuration of the main power transformers. Check the Equipment Data Plate to determine the exact AC requirement prior to installation. COARSE AND FINE TAPS are easily set to regulate the DC current to the xenon bulb. Some models of this power supplies have the capability of overdriving a xenon bulb; carefully check the power requirements specified by the bulb manufacturer and do not exceed the maximum current stated. DC OUTPUT to the xenon bulb is filtered by means of filter capacitors. A relayoperated resistor circuit reduces the inrush current upon ignition to prolong bulb life. Suppression capacitors prevent RF interference. OVERSIZE HEAT SINKS disperse the heat normally generated by the silicon diodes. Each power supply chassis include an internally wired blower for additional heat dissipation. Thermal switches on the rectifier heat sinks act as safety interlocks to shut down the power supply and protect the rectifier diodes in case temperatures reach excessive levels. INSTALLATION CHECK THE EQUIPMENT DATA PLATE and make certain that the AC source conforms to the power requirements of the main power transformers. See the Installation Diagram on Page 5 for detailed AC hook-up, line protection, and lamp connections. The AC service wiring should be installed by a licensed electrician in conformance to local codes. The unit must be connected to an adequate earth ground. THE AC LINE to the xenon power supply must include a marked line safety switch or other power disconnect device adjacent to the unit and accessible to the operator. For operator safety, it is necessary to turn off all power to the unit when adjusting or servicing the xenon power supply. This safety switch or power disconnect should be tagged OFF - UNIT UNDER REPAIR when the power supply is being serviced. 1

INSTALLATION (continued) OBSERVING ALL SAFETY PROCEDURES, install a xenon bulb of the desired wattage into the lamphouse. Check the bulb manufacturer s documentation to confirm the recommended current range of the 10 kw bulb (165-210 amperes DC). A new bulb is normally first operated at nominal current, which is around 85% of the maximum level (180 A.). DO NOT, at any time, exceed the maximum current level specified by the bulb manufacturer. IGNITE THE XENON BULB and check the current as indicated on the control panel ammeter. Allow (30) seconds for the current to stabilize and provide an accurate reading. If the current is not within the above-noted range, extinguish the bulb. It will be necessary to increase or decrease the DC output. OUTPUT CURRENT ADJUSTMENT WARNING Turn off ALL primary AC power before making any adjustments or performing service procedures. Allow several minutes for the capacitors to drain stored energy. The power supply normally operates warm to hot; allow the unit to cool to safe temperature. 2

INSTALLATION (continued) FINE ADJUSTMENT of the DC current is made to the NUMBERED taps found on the upper three terminal blocks (TB4, TB5, TB6). Fine taps are numbered 1-2-3-4, with 1 providing the lowest output, increasing to 4, yielding the highest output. A fine tap adjustment raises or lowers the current approximately four amperes. The three fine tap terminal blocks are interconnected by means of a three-lead jumper wire assembly attached to like-numbered terminals. To increase the DC output, move the jumper wire assembly to tap the next (3) higher numbered terminals, for example, move from terminals 2 to terminals 3. ALL TAPS MUST BE ON THE SAME NUMBERED POSITION (1-1-1, 2-2-2, 3-3-3, or 4-4-4). If the DC output is still too low when terminals 4 are interconnected, see the following instructions for adjusting coarse taps. To decrease the DC output, move the jumper wire assembly to tap the next (3) lower numbered terminals, for example, move from terminals 3 to terminals 2. ALL TAPS MUST BE ON THE SAME NUMBERED POSITION (1-1-1, 2-2-2, 3-3-3, or 4-4-4). If the DC output is still too high when terminals 1 are interconnected, see the following instructions for adjusting coarse taps. COARSE ADJUSTMENT of the DC current is made to the LETTERED taps found on the lower three terminal blocks (TB1, TB2, TB3). Coarse taps are lettered W-X-Y-Z, with W providing the lowest output, increasing to Z at the highest output. The coarse tap terminals connect to contactor terminals T1, T2, and T3. The (3) contactor leads must connect to the same lettered step (W-W-W, etc.). A coarse tap adjustment raises or lowers the current approximately twelve amperes. To increase the coarse DC output, move each of the contactor leads to tap the next higher lettered terminals, for example, move from terminals W to terminals X. ALL TAPS MUST BE ON THE SAME LETTERED POSITION (W-W-W, X-X-X, Y-Y-Y, or Z-Z-Z). Place the fine tap jumper on 1-1-1. Ignite the lamp, check the output, and increase the fine tap setting as required. To decrease the coarse DC output, move each of the contactor leads to tap the next lower lettered terminals, for example, move from terminals Y to terminals X. ALL TAPS MUST BE ON THE SAME LETTERED POSITION (W-W-W, X-X-X, Y-Y-Y, or Z-Z-Z). Place the fine tap jumper on 1-1-1. Ignite the lamp, check the output, and increase the fine tap setting as required. NOTE: Balance power supply output; i.e. set power supplies at or near the same output settings: Power Supply A X-X-X, 4-4-4 (or as required) Power Supply B Y-Y-Y, 1-1-1 (or as required) INSPECT TAP CONNECTIONS to verify that the terminal is clamping the copper conductor, not the insulation. Make certain all terminal clamping screws are tight. 3

INSTALLATION (continued) WHENEVER MAKING A COARSE ADJUSTMENT, again check the ammeter reading and make certain the current is within the desired range. A re-adjustment of the fine taps is frequently required after changing coarse taps. OBSERVE CURRENT (AMPERAGE) READING ONLY when setting the output. The voltage reading can vary between individual xenon bulbs, and while wattage can be determined by multiplying volts times amperes, it is possible to overdrive and damage the bulb by operating it over 210 amperes. The arc voltage reading serves as a troubleshoooting tool detailed later. REMOTE IGNITION CONTROL is enabled by connecting a dry contact across Terminals TB3-1 and TB3-2 and placing the REMOTE/LOCAL switch on the control panel to REMOTE. The lamphead will then ignite only when SYSTEM ON/OFF switch is in the ON position and the remote control contact is closed. AFTER PROLONGED OPERATION, the light output of the xenon bulb will decrease. This is a normal factor of bulb aging, and can be compensated by raising the DC output of the xenon power supply. If the bulb was first operated at nominal current, the power supply output can gradually be increased to, but not in excess of, he maximum current specified by the bulb manufacturer. Increase the current as instructed above. Decrease the power supply output to its former nominal current level upon the installation of a new replacement bulb. TIMER PC BOARD OPERATION TIMER PRINTED CIRCUIT BOARD ASSEMBLY (Part No. 32-70137) provides timing functions to lamphead ignition and shutdown. Upon closure of the POWER ON switch ( Local mode), and assuming all interlocks are closed, Relays K2 and K3 latch and energize the igniter circuit. The lamphead igniter will discharge and provide a pulsed arc between the electrodes of the xenon bulb. A functional bulb will normally ignite after one or two of these pulses. If the bulb does not ignite within a period of one (1) minute, the relays will drop out and de-energize the igniter circuit to protect the bulb electrodes. In this event, it is necessary to replace the xenon bulb or troubleshoot the lamphead and power supply system. THE STRIKE SWITCH on the control panel bypasses the above timing function and provides an immediate ignition pulse assuming the system is ON and all interlocks closed. AFTER EXTINGUISHING THE ARC (POWER OFF setting), Time-Delay Relay K4 will actuate and allow the cooling blowers to continue operating for 20 minutes. This measure is necessary to properly cool the xenon bulb and insure full bulb life. Most xenon bulb manufacturers will not grant warranty credit on bulbs that are not forced-air cooled after operation. 4

INSTALLATION WIRING DIAGRAM Power Source BRITELIGHT LAMPHEAD (Connections Prewired) Line Safety Switch P1 Fuse/Breaker Panel AC LINE PROTECTION 208/230 V. 380/440 V. 50 A. 25 A. Lamphead Cable Assembly TB9 Connections: 1 Green 2 Orange 3 Blue 4 Red 5 Black 6 White 7 Brown 8 Yellow OBSERVE CORRECT POLARITY AC Input SYSTEM MUST BE GROUNDED All wiring must conform to local electrical code; shield lamphead cable in conduit if required. XENON POWER SUPPLY 5

TROUBLESHOOTING WARNING: Exercise extreme caution when taking voltage measurements in a power ON condition. Allow the capacitors (2) minutes to discharge. POWER LINE PROBLEMS PRIMARY POWER (AC source) problems are most commonly (a) complete loss of AC power, or (b) phase loss, in which one phase loses power. a) Check line safety switch ( ON ). Check fuses or breakers in supply line. Using an AC voltmeter, measure input power at contactor terminals L1, L2, L3. b) When power is lost on one phase, the current ripple will increase and trip the AC line circuit breaker or blow an AC fuse. To detect a lost phase, measure the AC voltage phase-to-phase at contactor input terminals L1, L2, and L3. PROBLEMS of this nature, once detected, are generally corrected by the power supplier (i.e. the local utility company). BOOST CIRCUIT PROBLEMS THE BOOST CIRCUIT generates the high open circuit ( no load ) DC voltage which, in conjunction with the igniter pulse, will ignite the xenon bulb. The open circuit voltage should measure at least 110 V.DC. It is displayed briefly on the lamphouse ammeter by pressing the VOLT- AGE button at ignition, or the reading can be sustained by disabling lamphouse ignition by removing one AC lead from the igniter feed. A TERTIARY WINDING on the main transformer (T1) supplies the source for the Boost Circuit. Three wires derive from the T1 transformer; two are single conductors, and the third is a soldered pair. The Boost Circuit should be connected only to the (2) single conductors. Filter capacitors store energy and also contribute to bulb ignition. CONTROL CIRCUITRY THE MAIN POWER TRANSFORMER is energized by contactor K1, which is pulled by (a) a remote system closure or (b) manual actuation of the ON switch. All lamphouse interlock switches ( Door, Air, etc.) must also be closed to complete the contactor circuit. ANY INTERRUPTION of the control circuit will disable K1 and open the AC circuit to the transformers. In addition to the above lamphouse interlock switches, thermal switches (S1), mounted to the rectifier heat sinks, will open and disable K1 if the temperature at the heat sinks exceeds 190 F. (88 C.). The S1 switches will automatically re-set when temperatures fall to safe levels. 6

TROUBLESHOOTING (continued) POWER CONVERSION PROBLEMS RECTIFICATION (AC to DC) is performed by bridge diodes CR1 - CR6. CR1, CR2, and CR3 are forward diodes, and CR4, CR5, and CR6 are reverse diodes. The two types are not interchangeable. AN OPEN DIODE will cause a pronounced flicker in the light output. Two or more open diodes will disable bulb ignition. A shorted diode will trip the circuit breaker (at the wall or in a power distribution panel) protecting the AC input line. See the following DIODE TESTING & REPLACEMENT section. THE BANKED CAN CAPACITORS C3 and C7 filter the rectified DC output. Filter capacitors also store energy to contribute to the open circuit ignition discharge. A shorted capacitor can trip the AC circuit breaker. RELAY K6, in the presence of high DC open circuit voltage, will pull and place the nichrome resistor in series with the filter capacitors. This resistor limits the inrush surge and prolongs the discharge of the filter capacitors to promote bulb ignition. If K6 relay fails, the nichrome resistor will remain in circuit. DIODE TESTING & REPLACEMENT 1. Disconnect the diode from its circuit. Inspect for discoloration, oxidation, or loose crimp at lead junction. 2. A shorted diode will show low resistance in both directions. An open diode will have infinite resistance in both directions. An ohmmeter test is required. 3. a) Analog VOM (Volt-Ohm Meter): Select R x 1 Ohm scale. With meter leads connected in one direction, the reading should be zero (or nearly so); reversing the meter leads should show very high resistance. If the diode does not exhibit these characteristics, replace it. NOTE DIODE TYPE: forward or reverse. b) Digital VOM: Select Diode Test. With meter leads connected in one direction, the reading should be OL (overload); reversing the meter leads should display approximately.4 volt. If the diode does not exhibit these characteristics, replace it. NOTE DIODE TYPE: forward or reverse. 4. Carefully clean the area of the heat sink in which the diode mounts. Apply heat sink compound (Radio Shack #276-1373 or equivalent) using a wood or plastic spatula or stick. A thin layer is adequate. WARNING: HEAT SINK COMPOUND IS HIGHLY CAUSTIC. Do not apply with fingers; keep away from eyes. Carefully follow ALL the instructions printed on the package. 5. Install the new diode and tighten securely for maximum mechanical contact and electrical conduction. Clean and firmly secure the lead terminal to the buss. 7

TROUBLESHOOTING (continued) Contactor does not energize (no audible click ) 1. Line safety switch open. Turn ON. 2. AC line circuit breaker off. Turn ON. 3. Circuit breaker or fuse in AC line open. Check AC source. 4. REMOTE/LOCAL switch set incorrectly. Romote contact required when in REMOTE mode. 5. Lamphead interlock switch open. See lamphead manual. 6. Faulty K1 contactor coil or loose connection at coil terminals. Repair or replace. 7. Defective S1 thermal switch. Repair or replace. 8. Defective relay K1 or K6; Repair or replace. Contactor pulls but lamphouse igniter does not fire 1. Faulty contactor contacts. With coil energized, check for continuity across the contacts from the L side to the T side; repair or replace if defective. 2. Insufficient DC output. See INSTALLATION section; increase tap setting as required. 3. Faulty timer PC board assembly. If igniter fires when STRIKE switch is pressed, repair or replace timer board. 4. Faulty igniter. See lamphead manual. 5. Low open circuit voltage (less than 110 V.DC). a) Check ceramic resistors R1 & R2; should be in circuit and measure 100 Ohms. b) Check boost diodes D2 and D3. See preceding DIODE TESTING section. c) Check filter capacitors. Replace if defective. Bulb requires multiple ignition pulses to light 1. Insufficient DC output. See INSTALLATION section; set tap setting as required. 2. Faulty or expired xenon bulb. Check for darkened envelope, worn electrodes; replace if required. 3. One or more faulty bridge diodes. See preceding DIODE TESTING section. Bulb goes out during operation 1. Fuse F1 missing or open. Replace with same rated (3 ampere) fuse. 2. Excessive heat at rectifier heat sinks; thermal switch S1 opening. Check for free air flow, blower operating at full speed. Check for loose connection. 3. Faulty lamphead interlock switch ( Door, Air, etc.). See lamphead manual. Excessive flicker in light output 1. Improper tap setting. All taps must be on same numbered or lettered step. 2. Faulty bridge diode. See preceding DIODE TESTING section. 3. Faulty xenon bulb. Check for cracked or sagging electrode(s). 4. Leaking xenon bulb. Check for white or bluish discolored envelope, high current and low voltage (below 48 volts DC). Replace as required. 8

TROUBLESHOOTING (continued) Bridge diodes (CR1-6) fail repeatedly 1. Insufficient air flow; defective blower. Clean, repair, or replace as required. 2. Incorrect replacement diode. Use only the specified rated diode(s). Reduced light output 1. AC line voltage drop. Check AC line voltage; re-set DC output taps to compensate. 2. Bulb envelope discoloring with normal aging. Increase DC output setting; do not exceed 210 amperes. 3. Faulty xenon bulb. Check for cracked or sagging electrode(s). Replace as required. 4. Leaking xenon bulb. Check for white or bluish discolored envelope, high current and low voltage (below 48 volts DC). Replace as required. Elapsed Time Meter fails to record hours 1. Current sensor PC board not in contact with DC lead. PCB must be tie-wrapped to the insulation of one of the heavy DC output leads from the xenon power supply. 2. Defective component on current sensor PCB. Repair or replace; secure replacement board to DC lead as noted above. 3. Defective hour meter. Replace as required. MAINTENANCE VERY LITTLE MAINTENANCE is required to keep this power supply in good operating condition. Like most lighting equipment, regularly scheduled cleaning is most important. WARNING Turn off ALL primary AC power before making any adjustments or performing service procedures. Allow several minutes for the capacitors to drain stored energy. Allow the power supply to cool to ambient temperature. 1. Remove all accumulated dust and dirt from the rectifier. Vacuum the heat sinks. Make certain all air inlets and outlets are unobstructed. 2. Regularly check all electrical connections for tightness. Clean, retighten, or replace any discolored connections or terminals. 3. The blower motors contains sealed bearings and requires no lubrication. 9

WIRING DIAGRAM Britelight 10 kw Xenon Power Supply 10

FIGURE 1 12 3 13 11 14 15 9 8 10 7 1 2 4 5 3 6 11

PARTS LIST Figure 1 Item Part No. Description 1 32-00215 Top Cover Panel - 4100621 Mounting Screw, 10-32 x 5/8" - 4107101 Flatwasher, #10 2 32-00412 Rear Panel - 4100621 Mounting Screw, 10-32 x 5/8" - 4107101 Flatwasher, #10 3 32-90014 Power Supply Chassis Assembly (see Figure 3) - 4250752 Mounting Screw, 1/4-20 x 3/4" - 4254001 Lockwasher, 1/4" - 4257102 Flatwasher, 1/4" 4 32-70137 Timer Printed Circuit Board Assembly (includes Relays K2, K3, & K4) 5 32-00223 Control Panel Assembly (see Figure 2) 6 32-00414 End Panel, Control Side - 4100621 Mounting Screw, 10-32 x 5/8" - 4107101 Flatwasher, #10 7 32-00222 Bottom Panel 8 31-62011 Terminal Section (8 req d.) - 31-62012 Terminal Strip End 9 31-62025 Barrier Strip 10 32-00019 Capacitor Assembly (2 req d.) - 31-08133 Power Factor Capacitor, 60µf, 370 V.AC - 32-40724 Bracket 11 31-62044 Barrier Strip (2 req d.) 12 32-00410 Front Panel - 4100621 Mounting Screw, 10-32 x 5/8" - 4107101 Flatwasher, #10 13 32-00413 Blower Panel - 4100621 Mounting Screw, 10-32 x 5/8" - 4107101 Flatwasher, #10 14 71627000 Blower, 220 V.AC, 50/60 Hz. (2 req d.) 15 32-00192 Frame, Welded Assembly 12

1 2 3 4 5 FIGURE 2 15 14 13 12 11 10 9 8 7 6 Item Part No. Description 1 31-30005 Indicator Light, Red 2 31-30006 Indicator Light, Green 3 31-32004 Elapsed Time Meter 4 31-32007 Volt Meter 5 31-32006 Ammeter 6 32-00218 Panel (less Components) 7 4100621 Mounting Screw, 10-32 x 5/8" 8 31-98160 Test Point Socket, Black 9 31-98162 Test Point Socket, Red 10 31-61049 Focus Switch, Momentary - 11-98150 Rubber Switch Boot 11 31-61030 Strike Switch, SPST Pushbutton - 31-61065 Rubber Switch Boot 12 31-61048 On-Off Switch, DPDT 13 31-61048 Remote/Local Switch, DPDT - 11-98150 Rubber Switch Boot 14 31-61015 Switching Circuit Breaker, 5 A. - 31-61126 Rubber Boot 15 31-30076 Indicator Light, Amber MOLEX CONNECTORS (not shown) Part No. Description 31-13283 Two-Pin, Male 31-13288 Two-Pin, Female 31-13033 Six-Pin, Male 31-13288 Six-Pin, Female 31-13262 Twelve-Pin Male 13

FIGURE 3 23 22 24 20 21 19 1 18 2 5 6 16 15 14 3 4 7 7 17 8 11 12 13 10 9 XENON POWER SUPPLY CHASSIS 14

PARTS LIST Figure 3 Item Part No. Description 1 82-40264 Capacitor Mounting Bracket 2 61-06001 Capacitor Clamp (2 req d.) 3 61-08027 Filter Capacitor, 5400 µf, 200 V.DC (C3, C7) 4 82-40248 Shorting Bar 5 82-40047 Terminal Board Mounting Plate, Phenolic 6 91-64011 Power Transformer (T1), 208/230 V.AC, 50/60 Hz. Input 6 91-64007 Power Transformer (T1), 380/440 V.AC, 50/60 Hz. Input Item 6 Transformer includes Item 5 Mounting Plate & (6) Item 24 Terminal Blocks. 7 82-40040 Support Bracket, Rectifier Heat Sinks 8 81-46026 Ceramic Resistor (R1, R2), 100 Ohm, 100 W. 9 82-40254 Heat Sink Mounting Plate, Phenolic 10 81-45016 Relay (K6) 11 21-62067 Terminal Block Segment (3 req d.) - 21-62066 Terminal Block End 12 31-21054 Fuse Block 13 31-21038 Fuse, 30 A. 250 V. 14 32-40624 Chassis Plate, Welded Assembly 15 82-40255 Heat Sink Mounting Plate 16 82-20032 Heat Sink 17 81-47004 Forward Diode (CR1,2,3), 100 A. 300 V. (1N3290) 18* 61-71010 Positive Lead (Red) 19* 61-71009 Negative Lead (Black) - 94129000 Ring Terminal (2 per lead req d.) - 32-70140 Current Sensor Printed Circuit Board Assembly 20 91-98031 Buss Bar (3 req d.) 21 81-47001 Reverse Diode (CR4,5,6), 100 A. 300 V. (1N3290R) 22 81-33026 Squirrelcage Blower, 230 V.AC, 50/60 Hz. 23 81-14003 Contactor (K1) 24 81-62001 Tap Terminal Block (6 req d.) * Order by foot 15