CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

Similar documents
CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

Uninterruptible Power System

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

1. Important Safety Warning

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

User Manual. PF0.9 1K/2K/3K Online UPS. Uninterruptible Power Supply System. Version: 1.3

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

1KVA/ 2KVA/ 3KVA/ 4KVA/ 5KVA MS, LV MPPT INVERTER / CHARGER. User Manual. Version: 2.3

User Manual 1KVA-5KVA INVERTER / CHARGER

User Manual 1.5KVA-3KVA INVERTER / CHARGER. Version: 1.1

SAFETY WARNINGS AND GUIDELINES

User Manual 1KVA-5KVA INVERTER / CHARGER

User Manual 1KVA-5KVA (PF1) INVERTER / CHARGER. Version: 1.0

User Manual Rittal PMC UPS 6kVA

Solar Hybrid Inverter SP Brilliant Series

Liebert GXT MT+ User Manual VA Installer/User Guide

User Manual 4KVA/ 5KVA INVERTER / CHARGER. With MPPT Controller

User Manual 5KVA/5KW INVERTER / CHARGER. Version: 1.3

ULTIMA W SERIES. 1K/2K/3K Online UPS USER MANUAL

USER MANUAL ONLINE UPS

MPPT Controller PVTS Series User Manual. User Manual. 800W-4000W Hybrid solar inverter. Version: 1.4

User Manual SOLARMAX 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

Solar Hybrid Inverter SP Efecto Series

General Precautions. Personnel Precautions

User Manual 1.5KVA-3KVA INVERTER / CHARGER

Solar Hybrid Inverter SP Efecto Series

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

User manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger

User Manual 1KVA-5KVA INVERTER / CHARGER. Version: 2.1

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

Centurion 1000/1500/2000/3000 Tower/Rackmount On Line UPS User s manual

NEWTECH PRO X KVA DSP LCD 1/1 ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

User Manual V1.0 MaxiFlex 3000

R series solar charger inverter 1000W to 6000W

Uninterruptible Power System

Solar inverter with MPPT AX II - M series: 4 / 5 kva, AX II - P series: 3 kva. With integrated star point grounding* according to VDE AR-E 2510-

Uninterruptible Power System

User Manual. Axpert King 3.2KW/5.2KW 48V MPPT SOLAR INVERTER. Version: 1.0

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

User Manual. 6K/10K Online UPS. Uninterruptible Power Supply System

Microcare Inverter Manual

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

User Manual. PF0.9 6K/10K Online UPS

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Sine Wave Solar UPS. Owner s Manual. Thank you for choosing the intelligent NON STOP Solar UPS with state of art technology.

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

FlinSlim Lite Solar Hybrid Inverter 1KVA-5KVA USER MANUAL. Version: 1.3

User Manual 3KVA-5KVA INVERTER / CHARGER. Version: 1.1

MERU Solar Off-Grid Inverters

Installation and Operation Back-UPS BX550CI-CN

USER MANUAL DN / DN

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

Application. Battery. Public Grid GS HYBRID INVERTER

Solar Hybrid Inverter SP Initial Series

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

User Manual 1KW-5KW SOLAR INVERTER / CHARGER. Version: 1.2

User Manual. 1P-1P 6KL/7.5KL/10KL Online UPS

User Manual. EGL - 6K/10K Online UPS. Uninterruptible Power Supply System

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

BRAVER UPS. (Uninterruptible Power System) User s Manual

User Manual 3KW/5KW INVERTER / CHARGER. Version: 1.0

MICROCARE 3 PHASE INVERTER MANUAL

USER'S GUIDE. WiseHP11 SINGLE PHASE HIGH PRECISION AVR SERVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

USER MANUAL. PowerMust 1080 LCD (1KVA), Online, IEC PowerMust 2016 LCD (2KVA), Online, IEC PowerMust 3024 LCD (3KVA), Online, IEC

according to VDE AR-E Manual V 3.1

SOLAR INVERTER/CHARGER SOLAR INVERTER/CHARGER MPPT 2KVA- 3KVA. Appliances. Airconditioning Fridge. Washing machine

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

POWER. Inverters.

Uninterruptible Power System

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

User M anual. Rack/Tower Online UPS 1K/1.5K/2K/3K

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

Low Frequency Inverter. User Manual

User Manual LV 3KVA-24V INVERTER / CHARGER. Version: 1.1

FRUK+19 6K / FRUK+19 10K FRUK RM-01V / FRUK RM-01V

MPPT Solar Integrated Inverters (500VA~2500VA) User Manual THE SOLAR TECH CO.,LTD. Solar Integrated Inverter Series 500VA~2500VA 13.

w w w. o p t i - s o l a r. c o m Tel: Catalogue Fax: mail: OPTI-Solar USA: Tel: Fax: OPTI-Solar Europe:

User Manual. 6K/10K Online UPS with Isolation Transformer. Uninterruptible Power Supply System

Installation and Operation Manual Back-UPS BX1100CI-CN

USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

SOLARINVERTER MPPT 4KVA - 5KVA

Centurion. 6000/10000 VA Rack Online UPS. Users Manual.

USER MANUAL. E4 LCD TX 5000(S) / 6000(S) / (S) With Output Isolation Transformer. Uninterruptible Power Supply System

SmartOnline 3-Phase In/Out 120/208V 20kVA 16kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, DB9 Serial, Hardwired

USER MANUAL. Power GUARD UPS. Uninterruptible Power System

Installation and Operation Manual Back-UPS BR800/1100CI-IN

USER S MANUAL SOLAR POWER INVERTER KW-6KW

User Manual. 6K/10K Online UPS with Isolation Transformer

Transcription:

USER MANUAL

1

CONTENTS 1. INTRODUCTION... 1 2. SAFTY INSTRUCTION... 3 3. CABLE CONNECTION... 4 4. SYSTEM DESCRIPTION... 5 5. OPERATION... 9 6. TROUBLE SHOOTING GUIDE... 25 7. OPERATION MODES..... 27 8. SPECIFICATION...... 29

1. INTRODUCTION 1.1 General Description The Inverter/ Charger (solar charge controller as optional), a powerful all-in-one solution, delivers unsurpassed clean true sine wave output power and combines this with a selectable multistage battery charging current. Applicable for any kind of loads such as air conditioner, home appliances, consumer electronic and office equipments. This series features a durable&continuous 24 operation. The built-in 5-stage intelligent charger automatically charges any type of batteries without the risk of overcharge. The compact&modular design makes utility interactive installations easier and more cost effective. It is a high quality product that offers the best price/performance ratio in the industry. 1.2 Key features 1. Multiple microprocessor design base. 2. Compatible with both linear&non-linear load. 3. Stronger charger to support batteries of 500AH up. 4. 24 hours operation on the inverter. 5. DC start and automatic self-diagnostic function. 6. THD less than 3%. 7. High efficiency design to save electricity. 8. Low heat dissipation in long time operation 9. Design to operate under harsh environment 10. 3U 19 Rack Mount or WALL Mounted design 11. DC priority or AC priority selectable 1.3 Important Notices 1. Read instructions carefully before operating the Inverter/ Charger. 2. Inverter/ Charger power connect instruction should be followed. 3. Please don t open the case to prevent danger. 4. Maximum solar charging current: 50AMP 5. Retain the load within the rating of Inverter/ Charger to prevent faults. 6. Keep the Inverter/ Charger clean and dry. 1

2. SAFTY INSTRUCTION 2.1 Transporting 1. Disconnect all power cables if necessary. 2. Be careful not to damage the Inverter/ Charger while transporting. 3. Don t move the Inverter/ Charger upside down. 4. Please transport the Inverter/ Charger system only in the original packaging (to protect against shock and impact). 2.2 Positioning 1. Do not put the Inverter/ Charger on rugged or declined surface. 2. Do not install the Inverter/ Charger near water or in damp environments. 3. Do not install the Inverter/ Charger where it would be exposed to direct sunlight or near heat. 4. Do not block off ventilation openings in the Inverter/ Charger system s housing and don t leave objects on the top of the Inverter/ Charger. 5. Keep the Inverter/ Charger far away from heat emitting sources. 6. Do not expose it to corrosive gas. 7. Ambient temperature : 0-40 2.3 Installation 1. Connect the Inverter/ Charger only to an earthed shockproof socket outlet. 2. Place cables in such a way that no one can step on or trip over them. 2

2.4 Operation 1. Do not disconnect the mains cable on the Inverter/ Charger or the building wiring socket outlet during operations since this would cancel the protective earthing of the Inverter/ Charger and of all connected loads. 2. Ensure that no fluids or other foreign objects can enter the Inverter/ Charger system. 2.5 Maintenance and Service 1. Caution - risk of electric shock. Even after the unit is disconnected from the mains power supply (building wiring socket outlet), components inside the Inverter/ Charger are still connected to the battery and are still electrically live and dangerous. Before carrying out any kind of servicing and/or maintenance, disconnect the batteries and verify that no current is present. 2. Batteries may cause electric shock and have a high short-circuit current. Please take the precautionary measures specified below and any other measures necessary when working with batteries: - remove wristwatches, rings and other metal objects - use only tools with insulated grips and handles. 3

3. CABLE CONNECTION 3.1 Inspection 1. The system may be installed and wired only by qualified electricians in accordance with applicable safety regulations. 2. When installing the electrical wiring, please note the nominal amperage of your incoming feeder. 3. Inspect the packaging carton and its contents for damage. Please inform the transport agency immediately should you find signs of damage. Please keep the packaging in a safe place for future use. 3.2 Connection 1. Inverter/ Charger Input Connection If the Inverter/ Charger is connected via the power cord, please use a proper socket with protection against electric current, and pay attention to the capacity of the socket. 2. Inverter/ Charger Output Connection The output of this model is with terminal block. Simply wire the load power cord to the output terminal to complete connection. 4

4. SYSTEM DESCRIPTION 4.1 Front Panel Description for LCD Model 1. LCD Display: This indicates the Inverter/ Charger operation information, including UPS status, input/output voltage, input/output frequency, battery voltage, battery capacity left, output load, inside temperature, and the times of history events. 2. Up-key: Use to select upward the Inverter/ Charger status on LCD Display. 3. Down-key: Use to select downward the Inverter/ Charger status on LCD Display. Beside, press it simultaneously with the Up-key to switch off the Inverter/ Charger. 4. Enter-Key: It is pressed with the Down-key to turn on the Inverter/ Charger. In battery operation mode, press it with Up-key at the same time to disable the buzzer. Beside, it is pressed to confirm and enter the item selected. 5. Fault LED (red): To indicate the Inverter/ Charger is in fault condition because of inverter shutdown or over-temperature. 6. Warning LED (yellow): To indicate the Inverter/ Charger is in the status of overload, bypass and battery back-up. 7. Normal LED (green): To indicate the Inverter/ Charger is operating normally. 8. ON/TEST/MUTE key: It should be pressed with the control key simultaneously to switch on Inverter/ Charger, do auto-test in normal AC mode and turn off the buzzer in battery operation. 5

4.2 Outline Description 800W Rack Mount Type 1600W / 2400W Rack Mount Type 6

800W Wall Mounted Type 1600W / 2400W Wall Mounted Type 4000W / 6000W / 8000W Wall Mounted Type 7

800W Wall Mounted Type (Black case) 1600W / 2400W Wall Mounted Type (Black Case) 8

5. OPERATION 5.1 Check Prior to Start Up 1. Ensure the Inverter/ Charger is in a suitable positioning. 2. Check input cord is secured. 3. Make sure the load is disconnected or in the OFF position. 4. Check if input voltage meets the Inverter/ Charger rating required. 5.2 Storage Instruction Disconnect input power in rear panel if you will not use it for long period. If the Inverter/ Charger is stored over 3 months, please keep supplying power to the Inverter/ Charger for at least 24 hours to ensure battery fully recharged. 5.3 Operation Procedure for LCD Model Please follow the instructions below for Inverter/ Charger operation. 1. Once the AC source is connected, the LCD Display shall light up immediately to display first the main menu of greeting context and the Normal LED is blinking to indicate ready to switch on the inverter. 2. By pressing the Enter-key and the Down-key simultaneously for 3 seconds, the Inverter/ Charger will start up after two beeps and Normal LED lights up to indicate the power is from its inverter to the load. 3. When the Down-key and the Up-key are pressed simultaneously for 3 seconds, the inverter will be turned off after two beeps and the Inverter/ Charger is on the standby status (LCD display illuminates and Normal LED is blinking) until AC source is disconnected. 9

5.4 LCD Display Menu Use Up/Down key to select menu-displays of the LCD described below. This screen will refresh once the system power is enabled. Rated Spec Status Voltage Frequency 10

Battery Status Output Power Temperature History Record 11

5.5 GREEN POWER SETTING After the startup screen, the LCD will display the main menu as shown in the photo. Press the key in the middle continuously until seeing the same display as shown in the photo. Then press the enter key at right, and there will be a cursor ( ) shown between SETTING and AC TO AC Press enter key again so the cursor will move down to the position between GREEN and OFF. 12

Press the key in the middle once, the LCD Display shall now display GREEN ON 30sec Press the enter key at right again, and the cursor shall move to the right and now pointing 30sec. There are 4 options (15sec, 30sec, 45sec, 60sec) for how often to run the detection. After completing the setting, press the enter key at right. The LCD Display shall display FUNCTION SETTING SAVE? NO as shown in photo. Press the key in the middle, the text NO shall now become YES, then press the enter key again to confirm the setting. 13

The same screen as shown in the photo shall be displaying, and the inverter will automatically run the detection on GREEN POWER every 30 sec. Remark: When AC IN source is connected, the Normal LED will light up; when AC IN source is not connected, the Warning LED will light up. 14

5.6 DC TO AC SETTING After startup, we can change the LCD display by the & key Press the key till you see the display shown in the picture. Press the Enter key < at right, and then you will be able to see an arrow between SETTING and AC TO AC Press the key, and switch AC TO AC to DC TO AC 15

After finishing setting, press the ENTER key < and move to save option. Press the key and switch NO to YES at save function, and then press the ENTER key < again to save Now we complete the setting for DC TO AC mode Remark: In DC TO AC mode, AC will not be operated until the DC IN is shut down. in other words, AC will not start working such as charging or outputting until switching back to AC IN. When the system detects that the AC IN is gone, it will switch back to DC TO AC automatically. It is running as loop. 16

5.7 AC INPUT VOLTAGE SETTING After startup, press the in the middle, and stop at I/P VOLT SETTING Press the ENTER key < at right, the arrow will appear at bottom before LO. Press the & key to adjust the AC input value for low voltage Press the ENTER key < again, the arrow will switch the position before HI. Press the & key to adjust the AC input value for high voltage After finishing setting, press the ENTER key < and move to save option. 17

Press the key, switch NO to YES at save function, and then press the ENTER key < again to save Now we complete the setting for adjusting the value to AC INPUT HIGH/LOW VOLTAGE Remark: Low voltage 110V system Range: 60V~100V 220V system Range 120V~200V High voltage 110V system Range: 125V~140V 220V system Range 250V~280V 18

5.8 OUTPUT VOLTAGE AND FREQUENCY ADJUSTMENT SETTING After startup, press the in the middle, and stop at VOLT/FREQ SET Press the ENTER key < at right, the arrow will appear at bottom before 100 VAC. Press the & key to adjust the output voltage Press the ENTER key < again, the arrow will switch the position before 50HZ(or 60HZ). Press the & key to adjust the output frequency After finishing setting, press the ENTER key < and move to save option. 19

Press the key and switch NO to YES at save function, and then press the ENTER key < again to save Now we complete the setting for OUTPUT VOLTAGE AND FREQUENCY ADJUSTMENT Remark: Four setup values for 110V 100V 110V 115V 120V Four setup values for 220V 200V 220V 230V 240V Two options for frequency change: - 50HZ - 60HZ 20

5.9 LOW VOLTAGE SHUTDOWN SETTING After startup, press the in the middle, and stop at BAT.SHUT Press the ENTER key < at right, the arrow will then appear between BAT.SHUT and MIDDLE Press the & key to set up the voltage value for shutdown protection After finishing setting, press the ENTER key < and move to save option. 21

Press the key, switch NO to YES at save function, and then press the ENTER key < again to save Now we complete the setting for setup value to BATTERY LOW VOLTAGE SHUTDOWN Remark: Three different setup values for low voltage shutdown protection. HIGH: 42V. MIDDLE: 40V LOW: 38V Default Value: MIDDLE - 40V 22

5.10 BATTERY CHARGE CURRENT SETTING After startup, press the in the middle, and stop at the CHG.. CURR display Press the ENTER key < at right, the arrow will then appear between BAT.SHUT and MIDDLE Press the ENTER key < again, the arrow will switch to bottom between CHG. CURR and MIDDLE Press the & key to set up the charging current 23

After finishing setting, press the ENTER key < and move to save option. Press the key, switch NO to YES at save function, and then press the Enter key < again to save Now we complete the setup value for BATTERY CHARGING CURRENT Remark: Three different setup values for battery charging current. HIGH: 100A. MIDDLE: 80A LOW: 60A Default Value: MIDDLE - 80A 24

6. TROUBLE SHOOTING GUIDE 6.1 For LCD Model The following guideline may be helpful for basic problem solving. No. UPS STATUS POSSIBLE CAUSE ACTION AC utility power is normal. 1. Charger PCB is 1. Replace the charger Inverter/ Charger is damaged. PCB. 1 running normally, but fault LED lits up. Buzzer beeps continuously. 2. Fan is damaged. 3. Unknown 2. Replace the fan. 3. Restart AC utility power is normal Overload Please reduce the 2 but Inverter/ Charger is overloaded. Warning LED 100%< load< 125% critical load to <100%. lits up and buzzer beeps per second. AC utility power is normal. Overload Please reduce the 3 Warning LED does not fade out and buzzer beeps per 0.5 second. 125%< load<150% critical load to <100%. AC utility power is normal. Overload Please reduce the 4 Warning LED lits up and buzzer beeps continuously. 150%< load critical load to <100%. 25

No. UPS STATUS POSSIBLE CAUSE ACTION AC utility power fails.the 1. AC utility power 1. Reduce the less load is supplied by battery failure. critical load in order 5 power. Buzzer alarm sounds every 4 seconds. 2. AC input connection may be not correct. to extend backup time. 2. Please check the rated input or connected line. AC utility fails. Inverter/ Battery power is Inverter/ Charger will Charger is in battery backup approaching low level. shut down 6 mode. Buzzer alarm beeps automatically. Please every second. save data or turn off the loads soon. AC utility power fails. Battery runs out Inverter/ Charger will 7 Inverter/ Charger has shut down automatically. restart up when AC utility power is restored. 26

7. OPERATION MODES 7.1 Inverter/ Charger System Block Diagram 7.2 Normal Operation (AC Priority) There are two main loops when AC utility is normal: the AC loop and the battery charging loop. The AC output power comes from AC utility input and passes through static switch to support power to load. The battery charging voltage comes from AC utility input and converted by AC/DC charger to support battery-charging power. 7.3 AC Utility Failure (Battery Mode) The AC output comes from battery, passing through DC/AC inverter and static switch within the battery backup time. 27

7.4 Normal Operation (DC Priority) The AC output comes from battery, passing through DC/AC inverter and static switch within the battery backup time. 7.5 DC Utility Failure (Out-Of-Battery Mode) The AC output power comes from AC utility input and passes through static switch to support power to load. The battery charging voltage comes from AC utility input and converted by AC/DC charger to support battery-charging power. **please refer to P.17-5.6 DC to AC SETTING 28

8. SPECIFICATION Capacity Input Output Model VA / Watt Nominal Voltage Voltage Range Voltage Acceptable Voltage Range INVERTER 800W 1.2KVA / 800W INVERTER 1600W 2.4KVA / 1600W 220Vac; 110Vac 120-280Vac ; 60-140Vac INVERTER 2400W 3.6KVA / 2400W Frequency 50Hz / 60Hz ( 45Hz - 70Hz) Line Low Transfer Line Low Return Line High Transfer Line High Return Voltage Regulation (Batt. Mode) Frequency Frequency Regulation (Batt. Mode) 120VAC ± 2% ; 60VAC ± 2% 130VAC ± 2% ; 65VAC ± 2% 280VAC ± 2% ; 140VAC ± 2% 260VAC ± 2% ; 130VAC ± 2% 200 / 220 / 230 / 240Vac re-settable via LCD panel) 100 / 110 / 115 / 120Vac re-settable via LCD panel) < 3% RMS for entire battery voltage range 50Hz or 60Hz ±0.1Hz Power Factor 0.67 Waveform Pure Sinewave Effiecincy > 75% > 80% Overload Protection Line Mode Battery Mode Circuit Breaker 110% ~ 150% for 30 sec., >150% for 200ms Transfer Time Typical < 8 ms. Battery Battery Voltage Backup Time (at full load) Max. Charging Current (3 steps selectable) 24Vdc (20~32) long time available 60 / 80 / 100 Amp 29

Model INVERTER 800W INVERTER 1600W INVERTER 2400W Battery Voltage 24V Charge Vlotage 27.7V Solar Charge (SLU) Solar Maximum Peak Voltage Solar Charge Working Voltage Maximum Charging Current Polarity Protect 50.0V 24.0V 50A YES Display LCD Back Flow Protect LCD LED YES UPS status, I/P&O/P Voltage Frequency, Load%, Battery Voltage & %, Charge current, Temperature, Model Normal (Green), Warning (Yellow), Fault (Red) Battery Mode Beeping every 4 seconds Audible Alarm Environment Low Battery UPS Fault Overload Operation Temperature Relative Humidity Beeping every second Beeping Continuously Beeping twice per second 0-40 degree C; 32-104 degree F 0-95% non-dondensing Physical Audible Noise Less than 55dBA (at 1M) Net Weigh (Kgs) 14 21 23 (WxHxD)mm Black Case (WxHxD)mm Rack Mount (WxHxD)mm Wall Mounted 298*400*155 298*450*150 298*450*150 440*132*290 440*132*360 440*132*360 298*400*150 298*450*190 298*450*190 Specifications are subjected to change without prior notice. 30

Capacity Input Model VA / Watt INVERTER 4000W 5KVA / 4000W INVERTER 6000W 6KVA / 6000W INVERTER 8000W 8KVA / 8000W Nominal Voltage 220Vac; 110Vac 220Vac only Voltage Range Voltage Acceptable Voltage Range Frequency Line Low Transfer Line Low Return Line High Transfer Line High Return Voltage Regulation (Batt. Mode) 120-280Vac ; 60-140Vac 50Hz / 60Hz ( 45Hz - 70Hz) 120VAC ± 2% ; 60VAC ± 2% 130VAC ± 2% ; 65VAC ± 2% 280VAC ± 2% ; 140VAC ± 2% 260VAC ± 2% ; 130VAC ± 2% 200 / 220 / 230 / 240Vac re-settable via LCD panel) 100 / 110 / 115 / 120Vac re-settable via LCD panel) 120-280Vac 50Hz / 60Hz ( 45Hz - 70Hz) 120VAC ± 2% 130VAC ± 2% 280VAC ± 2% 260VAC ± 2% 200 / 220 / 230 / 240Vac re-settable via LCD panel < 3% RMS for entire battery voltage range Frequency 50Hz or 60Hz Output Frequency Regulation (Batt. Mode) ±0.1Hz Power Factor 0.8 1.0 Waveform Pure Sinewave Effiecincy > 80% Transfer Time Battery Overload Protection Typical Battery Voltage Line Mode Battery Mode Backup Time (at full load) Max. Charging Current (3 steps selectable) 31 24Vdc (20~32) Circuit Breaker 110% ~ 150% for 30 sec. >150% for 200ms < 8 ms. 48Vdc (42~62) long time available 60 / 80 / 100 Amp

Model INVERTER 4000W INVERTER 6000W INVERTER 8000W Battery Voltage 24V 48V Charge Vlotage 27.7V 55.2V Solar Charge (SLU) Solar Maximum Peak Voltage Solar Charge Working Voltage Maximum Charging Current Polarity Protect 50.0V 100V 24.0V 44.0V 50A YES Display LCD Back Flow Protect LCD LED YES UPS status, I/P&O/P Voltage Frequency, Load%, Battery Voltage & %, Charge current, Temperature, Model Normal (Green), Warning (Yellow), Fault (Red) Battery Mode Beeping every 4 seconds Audible Alarm Environment Low Battery UPS Fault Overload Operation Temperature Relative Humidity Beeping every second Beeping Continuously Beeping twice per second 0-40 degree C; 32-104 degree F 0-95% non-dondensing Audible Noise Less than 55dBA (at 1M) Physical Net Weigh (Kgs) 49.2Kg 51.4Kg 55Kg (WxHxD)mm Wall Mounted 415*600*260 415*600*260 415*600*260 Specifications are subjected to change without prior notice. 32