DRY TYPE TRANSFORMERS

Similar documents
The construction features of EdM transformers

DRY TYPE TRANSFORMERS

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

Cast resin transformers

Key features. DESIGNS: - Conservator type - Hermetically sealed

*(1(5$/7(&+1,&$/63(&,),&$7,2162) +9/9 ',675,%87,2175$16)250(56

OLIVER ONLINE VOLTAGE REGULATION

TGK Prefabricated Substation Technical Data

Minera. Oil distribution transformers up to kva. eco design. Minera at a glance. Standards

YOUR KEY ENERGY EFFICIENCY PARTNER CAST RESIN DRY-TYPE TRANSFORMERS

Distribution transformers Efficiency over life-cycle

CAST RESIN TRANSFORMERS CRT ED.: DEC.13 REV.00

P2 : About Us. P3 : Elsewedy Transformers. P4 : Why Elsewedy Dry Type Transformer? P6 : Cast Resin Dry Transformers. P7 : Technical Data Sheets

56-SDMS-07 REV. 01 SPECIFICATIONS FOR

COMPACT SUBSTATION GUIDE

BC IMPREGO Impregnated dry type transformers and autotransformers

LV Capacitor CLMD Reliability for Power Factor Correction

ABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology

Variable speed asynchronous motors with FCR brake LSMV FCR. General information

Three-phase isolating transformers for photovoltaic and wind-power systems

Certified for best-in-class performance, reliability, and safety. Trihal sets a new standard for dry-type cast resin transformers

CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION

34-SDMS-02 SPECIFICATIONS FOR

Isolating transformer DS0107. Three-phase isolating transformers for the supply of three-phase loads in medical locations

FLSD (E) Atmospheres containing explosive GAS totally enclosed three-phase asynchronous motors General information

Max. Input Power (W) Inrush Current (A pk /µs)

Compact Integrated Distribution Substation (CIDS)

ABB Ltd. FACTORY IN HANOI

1500 kva Pad Mount Transformer GRDY/14400V Primary - 208Y/120 Wye Secondary - Oil Cooled

CAST RESIN DISTRIBUTION TRANSFORMERS 2017 EDITION

Three-Phase Ventilated

LSPXMV FCR Atmospheres containing explosive dust FCR asynchronous brake motors. General information

DISTRIBUTION TRANSFORMERS CATALOGUE

Industrial Control Transformers

LV Capacitor Bank APC

General Purpose Buck - Boost Wiring Diagrams... 86

LV Capacitor CLMD03 Power Module Instruction manual

Contact us. Catalog Low voltage generators for diesel and gas engines Industrial Marine applications - series Standard series

LIST OF EDD DESCRIPTION/ SPECIFICATION AS 19 TH OCTOBER 2016

Isolating transformer ES710

500 kva Pad Mount Transformer V Delta Primary - 208Y/120 Secondary - NEMA 4X - Oil Cooled

CAST RESIN TRANSFORMERS

2013 JEAN MÜLLER Products

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

Single-phase step voltage regulators

CAST RESIN TRANSFORMERS

ABB Transformers Egypt

Technical Specifications

INESING GROUP. Power System Solution

Product Overview. Transformers & Reactors. Proficient. Innovative. Customer-orientated. Transformers up to 8MVA AC/DC Reactors up to 3000A

INESING srl. MOBILE SUBSTATIONS Energy Solution. Energy Innovation. INESING srl Energy Innovation

Transformer Stations

Distribution Transformers. The most comprehensive range of solutions for distribution transformer applications

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

Single-Phase Step Voltage Regulators

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

ÒÌÃ TRANSFORMERS. ÒÌÃ 1250 kv.a

Ecodesign Transformers Energizing the World since a company of Rauscher & Stoecklin SERW ZREW Tesar

DYNACOMP. The top-class reactive power compensator

GAS INSULATED VOLTAGE TRANSFORMERS.

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system.

Single-Phase Ventilated

SBOX1250kVA Technical Data Sheet

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

LV Capacitor Bank APC

ormaset-m PREFABRICATED METALLIC TRANSFORMER SUBSTATION

EMPAC Metal enclosed capacitor bank for wind applications

Innovac SVS/08 - SVS/ kv modular switchgear

tests Partial discharge level from day 1 10 pc Insulation 24 kv : impulse tested at 125 kv Insulation 36 kv : impulse tested at 170 kv, 200 kv indeed.

Company Overview. Since 1975 in the sector, solid experience of design and production of dry type electric transformers and inductances

High-voltage high-breaking capacity VV fuse-links

Excitation system is of Static Silicon Excitation System, including excitation transformer, thyristors, and AVR.

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders

Transformers Global product offering

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Design Data 3.2 Standard Accessories 3.3 Tolerances

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

FCR asynchronous brake motors LS FCR. General information

INSTRUCTION MANUAL BR 25 FOR RAILWAY APPLICATION 5COR BR25AT REV00

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Technical Data 3.2 Standard Accessories 3.3 Tolerances

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

NEXT STEP B) SAFETY :

Products & Services EQ Series AC Drives. TEAMMaster WOUND ROTOR MOTORS WORLD SERIES SYNCHRONOUS MOTORS. EXPLOSION PROOF (Division 1, Zone 1)

MESG 12 / 17.5 / 24 / 36 KV

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

Surge-Trap Pluggable STPT2 Series - 40kA

36.02 /// THREE-PHASE TRANSFORMERS

LSN Atmospheres containing explosive GAS totally enclosed three-phase asynchronous motors General information

2. INDUCTIVE VOLTAGE TRANSFORMERS Dry and oil-paper insulation

Industrial Control Transformers

Issue Title Remarks. Instrument transformers See IEC 61869

Solar Power Switchgear & Energy Storage Renewable Energy Systems

Design specifications

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

Cast Resin Transformers

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

A good connection. International approvals.

Vacuum Cast Coil Dry Type Distribution Transformers. The reliability in your hands.

DC/DC converters - MINI-PS DC/ 5-15DC/

Marcel Fortin ing. Hydro Québec Distribution 1

Transcription:

DRY TYPE TRANSFORMERS Single-phase, Three-phase/Single-phase, Three-phase/Two-phase,Three-phase 1.1 kv to 7.2kV Class

Dry Type Transformers Transformers meant to be installed in a dry and air conditioned room or in a PTI AUGIER type substation. ELECTRICAL CHARACTERISTICS : Power rating and type : Single-phase : TMAI : 5-7.5-10 - 16-25 - 32-50 kva Three-single : TTMAI : 16-25 - 32-50 - 63-80 - 100-125 - 160 kva Three-two : TTBAI : 16-25 - 32-50 - 63-80 - 100-125 - 160 kva Three-phase : TTAI : 16-25 - 32-50 - 63-80 - 100-125 - 160-200 250-400 - 500-630 kva Insulation voltage : 1.1 kv - 3.6 kv - 7.2 kv Primary voltage : Every voltage compatible with insulation voltages above. Usually standard voltages are : 230 V - 400 V - 950 V - 3200 V - 5500 V and 6600 V. Secondary load voltage : 230 V - 400 V - 950 V - 3200 V - 5500 V and 6600 V. Couplings : Standard : Three-phase transformer : Step-down Dyn11 - Step-up YNd1 single-phase transformer :Ii0 Specific : Three-single transformer, Leblanc three-two transformer, other couplings on request. Manufacturing specifications on request : Inrush current transformer reduced or very reduced. CONNEXION: Primary and secondary connesion on copper slots, by the upper side of the transformer. STANDARD ACCESSORIES : Empty setting plugs : Three outputs on slots. Two earthing switches. Lifting lugs. Four rollers for 10 kva and higher power rating transformers. NOTE : Transformers mechanical and electrical characteristics are the same for step-down or step-up transformers. The tranformers are not reversible. Step-up transfrormers are built so that inrush currents are limited. Single-phase transformer, TMAI type, with IP21 encolsure, fuse terminal 3200 V and locking. 2

CONSTRUCTION : Magnetical circuits with crystal made sheet metal, oriented, with low losses. Copper windings, vacuum impregnated of H class and applying of a fungicide varnish. Metallic flanges. Ironed chassis with rollers. Wooden terminals plate bakelised. Cooling Use Color : in natural air : NA. : use in dry, air conditioned rooms, at a room temperature of -15 C ; + 40 C. : RAL 7035 gray. STANDARDS AND TESTS : Conforms to NF C 17-200 - NF C 52-100 - IEC 60076 standards. Other specifications on request. Routine tests U.T.E made on each transformer, specific tests on request.. Dry type transformer, naked presentation on frame Connexion plates Tap changer MV side view LV side dismantle panel Fixation by screw Lifting lugs Connexion plates Dry type transformer With IP21 enclosure Side panel dismantling (cables passage) Fixation by screw Bakélite matter To be screwed on request rollers Signaletic plate Firm plate LV side dismantling panel 3

Three-phase dry Type Transformers TTAI ELECTRICAL CHARACTERISTICS : Power rating: 16-25 - 32-50 - 63-80 - 100-125 - 160-200 - 250-400 - 500-630 kva Insulation voltage : 1.1 kv - 3.6 kv - 7.2 kv Primary voltage : Every voltage compatible with insulation voltages above. Usually standard voltages are : 230 V - 400 V - 950 V - 3200 V - 5500 V and 6600 V. Secondary load voltage : 400 V - 950 V - 3200 V - 5500 V and 6600 V. Couplings : Step-down Dyn11 - Step-up YNd1, other couplings on request. CONNEXION : Primary and secondary connexions on copper plates, by the upper side of the transformer. STANDARD ACCESSORIES : Voltage tapping adjustable out of voltage : +/- 2,5 % or +- 5% output on slots. Two earthing terminals. Lifting lugs. Four rollers for 10 kva and higher power rating transformers. Naked presentation on frame : IP00. OPTIONAL ACCESSORIES Painted sheet metal enclosure with natural airing upwards, IP21. Connexion on pluggable terminals 3200 V or 5500 V. HRC fuses protection integrated above the protection envelop. Thermal protection by thermal probe integrated to windings, one or two thresholds protection. Tap changers +/- 2,5 % +/- 5%. Keyhole locking of the protection envelop and or pluggable terminals. NOTE : Transformers mechanical and electrical characteristics are the same for step-down or step-up transformers. The tranformers are not reversible. Step-up transfrormers are built so that inrush currents are limited. ELECTRICAL CHARACTERISTICS Power rating (kva) 16 25 32 50 63 80 100 125 160 200 250 400 500 630 Copper losses at 75 C (W) 350 470 550 800 1000 1100 1350 1400 2000 2300 2800 4200 5600 7300 Iron losses (W) 100 180 200 250 250 380 450 450 500 550 650 900 1250 1500 Voltage drop (% ) at Cos = 0.83 CC tension (%) at 75 C Empty current (%) 3.3 3 3.07 3.14 3.4 3 3.2 3 3.4 3.2 3.15 3.5 3.5 3.5 3.4 3.2 3.4 3.5 4 3.5 4 4 4 4 4 4 4.5 5 1 0.7 0.8 0.9 0.7 0.8 0.9 0.6 0.7 0.5 0.5 0.8 0.6 0.7 4

TTAI Dry Transformers SIZES-WEIGHT (mm) - PRESENTATION ON IP00 FRAME - STEP DOWN TRANSFORMER Power rating (kva) 16 25 32 50 63 80 100 125 160 200 250 400 500 630 A 636 750 825 825 840 930 930 950 980 1000 1096 1240 1400 1600 B 400 480 500 500 520 530 530 530 530 570 660 660 830 900 C 611 670 718 718 734 809 809 836 858 889 1086 1134 1300 1650 D 380 510 510 510 520 580 580 590 610 650 690 770 870 900 E 295 400 400 400 400 440 440 440 440 465 520 520 520 520 Weight (kg) 155 270 310 345 365 450 465 525 600 700 940 1185 1450 1800 Protection degree IP00 SIZES-WEIGHT (mm) - PRESENTATION WITH IP21 ENCLOSURE - STEP DOWN TRANSFORMER Power rating (kva) 16 25 32 50 63 80 100 125 160 200 250 400 500 630 A 850 960 1040 1040 1050 1140 1140 1160 1190 1220 1310 1550 1610 1810 B 550 630 650 650 660 660 660 660 680 720 810 810 980 1050 C 900 970 1020 1030 1040 1100 1100 1140 1200 1200 1390 1500 1600 1950 D 380 510 510 510 520 580 580 590 610 650 690 770 870 900 E 295 400 400 400 400 440 440 440 440 465 520 520 520 520 Weight (kg) 185 300 350 400 405 535 565 630 750 900 1150 1450 1700 2050 Protection degree IP21 5

Single-phase Dry Type Transformers TMAI ELECTRICAL CHARACTERISTICS : Power rating: 5-7,5-10 - 16-25 - 32-50 kva Insulation voltage : 1.1 kv - 3.6 kv - 7.2 kv Primary voltage : Every voltage compatible with insulation voltages above. Usually standard voltages are : 230 V - 400 V - 950 V - 3200 V. Secondary load voltage : 230 V - 950 V - 3200 V. Couplings : Standard : single-phase transformer : Ii0 CONNEXION : Primary and secondary connexions on copper plates, by the upper side of the transformer. STANDARD ACCESSORIES : Voltage tapping adjustable out of voltage : +/- 2,5 % ou +- 5% sorties sur plages. Two earthing terminals. Lifting lugs. Four rollers for 10 kva and higher power rating transformers. Naked presentation on IP00 frame. OPTIONAL ACCESSORIES Painted sheet metal enclosure with natural airing upwards, IP21. Connexion on pluggable terminals. HRC fuses protection integrated above the protection envelop. Thermal protection by thermal probe integrated to windings, one or two thresholds protection. Tap changers +/- 2,5 % +/- 5%. Keyhole locking of the protection envelop and or pluggable terminals. NOTE : Transformers mechanical and electrical characteristics are the same for step-down or step-up transformers. The tranformers are not reversible. Step-up transfrormers are built so that inrush currents are limited. ELECTRICAL CHARACTERISTICS Power rating (kva) 5 7,5 10 16 25 32 50 Copper losses at 75 C (W) Iron losses (W) Voltage drop (% ) at Cos = 0.83 Cc tension (%) at 75 C Empty current (%) 100 120 170 380 500 630 750 40 60 60 80 120 150 200 2.92 2.47 3.35 3.7 3.53 3.55 3.7 2.95 2.67 3.75 3.86 3.78 4 4 3.11 2.53 2.58 2.67 2.52 2.54 2.51 6

TMAI Dry Transformers SIZES-WEIGHT (mm) - PRESENTATION ON IP00 FRAME Power rating (kva) 5 7,5 10 16 25 32 50 A 320 400 400 540 600 630 650 B 320 390 390 400 400 450 460 C 372 560 494 632 652 710 749 D - - 320 300 315 270 270 E - - 218 230 245 270 270 Weight (kg) 45 72 84 140 190 230 265 Protection degree IP00 SIZES-WEIGHT (mm) - PRESENTATION WITH IP21 ENCLOSURE Power rating(kva) 5 7,5 10 16 25 32 50 A 380 424 424 570 630 670 700 B 344 414 414 450 460 550 570 C 532 570 600 830 850 960 1020 D - - 320 300 315 270 270 E - - 218 230 245 270 270 Weight (kg) 56 83 98 160 220 270 310 Protection degree IP121 7

60 40152 With constant improvements, the manufacturer may alter information without prior warning AUGIER IS CERTIFIED ISO 9001 SINCE 1995 8