Dry-Type Transformers Mini-Power Centers

Similar documents
Safety, Reliability and Performance verified with the KEMA KEUR mark. Series G Moulded Case Circuit Breakers

Innovac SVS/08 - SVS/ kv modular switchgear

100-Ampere Busway. Effective November 2005 New Information. Elbow, Busway and Cable Tap Box. Technical Data TD E

Unitole UP kv Primary substations Motor control centres

Single-Phase Ventilated

Three-Phase Ventilated

Class I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.

SPX9000 FR10 FR12 Adjustable Frequency Drives

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Unitole UP kv Primary substations Motor control centres

Medium Voltage Metal-Enclosed Switches

Totally Enclosed Non-Ventilated

Medium Voltage Metal-Enclosed Switches

MP-4000 Motor Protection

Features, Benefits and Functions

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

Capabilities Brochure

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at

SECTION PANELBOARDS

X1PB: Explosionproof Panelboards

Pow-R-Way III Busway Service and Solutions

6.2. Power Pedestals. Contents

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

Multi-Pak Group Control

Lighthouse Power Pedestals,

W-VACi MV circuit breakers

Transformers 6. Gross Automation (877)

POWERPLEX PANELBOARD 1

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

Overview Brochure Integrated Power Distribution. Medium Voltage Assembly Solutions

5.2. Power Pedestals. Contents Description

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

Xiria 24 kv Ring Main Unit

HPS Fusion General Purpose Enclosed Transformer

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions

RV Park Equipment Product Focus. Power Pedestals Distribution Equipment

Midwest Dry Type Transformers

ATLV MaxSG. Low Voltage Metal Enclosed Switchgear

Xiria 12 kv Ring Main Unit in IEC and ENATS design

P-9. ALPN, APPN and AGPN Series: Explosionproof, Dust-Ignitionproof, Watertight Non-Factory Sealed.

General Purpose Buck - Boost Wiring Diagrams... 86

Modular contactors, type CR

Design Standard. Purpose: Design Standard:

Bolted Contact Pringle Switch. Cutler-Hammer Bolted Contact Pringle. Effective Date March 16, 2009 Replaces TD T.K

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Panelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

Cutler-Hammer. Molded Case Circuit Breakers Amperes F-Frame. January 2001

DISTRIBUTION EQUIPMENT: NEC/CEC HAZARDOUS LOCATION SWITCHES. Application

Engine Generator Circuit Breakers

IT. IEC Contactors, Starters, Overload Relays, and Accessories Product Focus

NEC/CEC CLASS/ZONE RATED HAZARDOUS LOCATION CIRCUIT BREAKERS. Application

PlexPower Factory Sealed Panelboard 15 to 150 Amps. Stainless Steel Enclosures

XIRIA Green, Smart, Compact solution

Industrial Control Transformers

Pow-R-Way III Low Voltage Busway. Product Focus. Pow-R-Way III Offers a Full Line of Low Voltage Busway to Meet the Needs of a Global Marketplace

Switchboards Instant Service

Division 1 Explosionproof Panelboards

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

Air Conditioning Disconnects Molded Case Switch

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

Lighting and Power Distribution Panelboards

W-SLC Medium Voltage fused contactor truck A safe, reliable and efficient motor starter

Magnum IEC Low Voltage Air Circuit Breakers

Introduction. Features. Intelligent Technologies Motor Control Center Structures

A. This section includes unit capacitors for power factor correction.

Product guide. Enclosed NEMA starters. Answers for industry.

Eylander Electric Inc

A. This section includes enclosed dry type transformers for lighting and power loads, with primaries and secondaries rated 600 volts and less.

Cutler-Hammer Breakers. Cutler-Hammer Circuit Breaker Afci 1 Pole 15A BR115AF CUTLER HAMMER CIRCUIT BREAKER AFCI 1 POLE 15A BR115AF

Selection and Application Guide. busway system. Cost-effective Power Distribution Compact Design

Customer Requirements Downtown Secondary Network Service

HPS Fusion General Purpose Enclosed Transformer

Contents. Volume 1 Residential and Light Commercial CA E December

Series C, F-frame molded case circuit breaker, 15A, Two-pole, Thermal Magnetic Trip, FD Breaker

CIRCUIT BREAKER PANELBOARDS

Powering business worldwide

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS

SL Series IEC Vacuum Contactors. Medium Voltage Contactors Technical Focus

O & M Manual for the EATON Generator Ready Loadcenter

Distribution Dry Type Transformers 600 Volts Class Single and Three Phase Selection

Submittal Transmittal

Open-Style Power Distribution Blocks

Product Guide. enclosed NEMA STARTERS

3.6. Panelboards and Lighting Control. Contents Description Product Overview... Product Selection Guide... Pow-R-Command 750 Panelboard...

ALPF Factory Sealed Lighting - APPF Power Distribution Panelboards Explosionproof, Dust-Ignitionproof, Watertight

POWERBUS 225 Busway and Plug-In Units

Pow-R-Flex low ampere busway

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

New Products for Integrated Electrical Systems/Questions and Answers/Resources. necdigest. Bringing a new level of electrical protection into the home

Issued Revised Approved Reviewed October 31, 1984 October 22, 2002 J. Ross J. Fuller

! WARNING I.L D WARNING GENERAL INFORMATION

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

DBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

Product guide. Enclosed NEMA starters. usa.siemens.com/controls

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

NEC DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

Selection and application guide

Transcription:

Dry-Type Transformers Mini-Power Centers Product Focus Three individual components combined into a single unit to save space and costs, 3 to 30 kva

Dry-Type Transformers Mini-Power Centers Significant Savings in Cost and Space Plus Quicker Installation Three individual components combined into a single unit. Less is More...Exclusive 3-in-1 Design Contemporary electrical distribution systems are required to do more in less space, while at the same time being cost-effective. Eaton provides a solution to these requirements with the proven Mini-Power Center. It occupies considerably less space and can save up to 31 percent of the installation costs normally required when individual components are used. The solution is possible because a Mini-Power Center combines three individual components into one NEMA Type 3R enclosure: a main breaker, an encapsulated single-phase or three-phase dry-type transformer, and a secondary distribution loadcenter with main breaker. Interconnecting wiring is completed at the factory. A Mini-Power Center is delivered ready for installation. It s also suitable for use as service entrance equipment. Ratings Single-phase: 3, 5, 7.5, 10, 15 and 25 kva. Three-phase: 15, 22.5 and 30 kva. A Wide Variety of Proven Applications Mini-Power Centers are used wherever there is a 480 V or 600 V distribution system and loads requiring 208Y/120 V, three-phase or 120/240 V, single-phase. Typical installations include: Industrial plant assembly lines. Plant expansions. Test equipment. Temporary power at construction sites. Sewage disposal plants. Warehouses. Car washes. Parking lots. Commercial buildings. Irrigation systems. Easy to Install A variety of concentric knockouts on the sides and bottom. Wiring compartment includes ample space for conduit entry. Maximum wiring gutter space is provided for ease of wiring in compliance with NEC requirements. Simplified design includes two keyholes for easy mounting and leveling. 2 EATON CORPORATION Dry-Type Transformers Mini-Power Centers

Compare the Space Savings 30 Inches Instead of 72 Inches! Specify the Mini-Power Center Take advantage of the Mini-Power Center s space and cost savings! Have your architects, design engineers, and buyers insert the Cutler-Hammer Mini-Power Center with the catalog number in the specification. Mini-Power Center Components Circuit Breakers Primary and secondary main breakers are Cutler- Hammer Type EHD or FDB. (See Catalog Number Information on pages 4 and 5.) Aluminum chassis Mini- Power Centers are available with optional primary main circuit breakers having greater AIC ratings. (See table below right.) Feeder circuits can be easily added. For aluminum chassis loadcenters, Cutler-Hammer Type BR plug-in feeder breakers (10 kaic) are used. For copper chassis loadcenters, Cutler-Hammer Type BAB bolt-on feeder breakers (10 kaic) are used. Feeder breakers are not included and are purchased separately. Loadcenter Aluminum chassis standard for plug-in Type BR feeder breakers. Copper chassis available for bolt-on Type BAB feeder breakers. Space for up to 24 feeder breakers. Ground bar is provided as standard for grounding of individual secondary circuits. Neutral bar is grounded to the enclosure. Transformer Electrical grade aluminum windings are standard with plug-in loadcenter chassis. Electrical grade copper windings are standard with bolt-on loadcenter chassis. Plug-in chassis are optional with copper windings. 185ºC insulation system. 115ºC winding temperature rise. Sand and resin encapsulated core-coil assembly. Cores are grounded with a copper lead. Safety All live parts are enclosed for personnel safety and equipment protection. Padlockable hinged front cover prevents removal of breakers. Grounding terminal provided on the enclosure. Provision to add padlock kit #PLK1 to lock primary main breaker ON/OFF. Enclosures Standard NEMA 3R indoor/outdoor heavy gauge steel enclosure with a rugged baked-polymer polyester powder coat. ANSI 61 gray color. Optional NEMA 3R, grade 316 stainless steel. Standards UL listed and CSA certified. UL listed as service entrance equipment. Meets applicable ANSI, NEMA, IEEE and UL standards. Compare the Installation Cost Savings 31 Percent Less Because we knew that putting three components in one enclosure dramatically cuts installation time, we asked an electrical contractor to estimate the job two ways: Using a separate breaker, transformer and loadcenter, including the connecting cable and hardware. Using a Mini-Power Center. HERE ARE THE ESTIMATES: Installation 15 kva 25 kva Three- Mini- Three- Mini- Component Power Component Power System Center System Center Hours 1 Switch and Fuse Layout 4 0 4 0 Switch and Fuse Mount 1 0 1 0 Transformer Layout, Remove Knockout, etc. 16 16 24 24 Transformer Fastened to Wall 4 0 4 0 Loadcenter Layout, Mount and Connect Source 4 4 6 4 Total Hours 29 20 39 28 % Time Saved with Cutler-Hammer Mini-Power Center 31% Savings 28% Savings 1 Time estimates are typical and will vary by geographical area. OPTIONAL PRIMARY MAIN CIRCUIT BREAKERS FOR PLUG-IN CHASSIS Primary Main Breaker 480 Volt kaic 600 Volt kaic EHD/FDB 14/14 na/14 FD 25 18 HFD 65 25 FDC 100 35 Fused Switch Normal Layout 15 kva 3-Phase Transformer 72" Wide Mini-Power Center P1 Transformer Loadcenter Loadcenter 30" Wide P2 P1 Primary Breaker P2 Secondary Breaker EATON CORPORATION Dry-Type Transformers Mini-Power Centers 3

Product Selection Mini-Power Centers, and other dry-type transformers, are stocked by Eaton distributors. They are supported by regional distribution centers that maintain extensive inventories of virtually every dry-type transformer. For the distributor nearest you, call toll free 1-800-525-2000. CATALOG NUMBER INFORMATION Plug-in Mini-Power Center (Aluminum-wound transformer and loadcenter chassis standard) Full Feeder Capacity Breakers 45 Style Taps Dimensions 1 Inches (mm) Weight Main Circuit Breaker 2 Max. Number Max. kva Number FCBN Height Width Depth Lbs. (kg) Frame Primary 3 Secondary 1-Pole 2-Pole Amp Single-Phase 480 Volts to 120/240 Volts 3 P48G11S03P 2-5% 27.50 (698.5) 11.90 (302.3) 8.90 (226.1) 105 (47) 283 EHD2015 BR215 8 4 12 5 P48G11S05P 2-5% 29.50 (749.3) 11.90 (302.3) 8.90 (226.1) 105 (47) 284 EHD2020 BR225 12 6 20 7.5 P48G11S07P 2-5% 29.50 (749.3) 11.90 (302.3) 8.90 (226.1) 125 (56) 284 EHD2030 BR230 12 6 30 10 P48G11S10P 2-5% 32.50 (825.5) 13.10 (332.7) 11.60 (294.6) 177 (80) 285 EHD2040 BR250 12 6 40 15 P48G11S15P 2-5% 37.50 (952.5) 13.10 (332.7) 11.60 (294.6) 212 (96) 286 EHD2060 BR270 20 10 60 25 P48G11S25P 2-5% 43.40 (1102.4) 15.90 (403.9) 14.50 (368.3) 373 (169) 287 EHD2100 BR2125 26 13 100 600 Volts to 120/240 Volts 5 P60G11S05P 2-5% 29.50 (749.5) 11.90 (302.3) 8.90 (226.1) 105 (47) 284 FDB2015 BR225 12 6 20 7.5 P60G11S07P 2-5% 29.50 (749.5) 11.90 (302.3) 8.90 (226.1) 125 (56) 284 FDB2030 BR230 12 6 30 10 P60G11S10P 2-5% 32.50 (825.5) 13.10 (332.7) 11.60 (294.6) 177 (80) 285 FDB2040 BR250 12 6 40 15 P60G11S15P 2-5% 37.50 (952.5) 13.10 (332.7) 11.60 (294.6) 212 (96) 286 FDB2060 BR270 20 10 60 25 P60G11S25P 2-5% 43.40 (1102.4) 15.90 (403.9) 14.50 (368.3) 373 (169) 287 FDB2100 BR2125 26 13 100 Three-Phase 480 Volts to 208Y/120 Volts 15 P48G28T15P 2-5% 36.10 (916.9) 28.80 (731.5) 9.40 (238.8) 320 (145) 289 EHD3040 EHD3050 18 6 40 22.5 P48G28T21P 2-5% 40.90 (1038.9) 29.90 (759.5) 13.60 (345.4) 565 (256) 290 EHD3070 EHD3070 18 6 60 30 P48G28T30P 2-5% 41.90 (1064.3) 29.90 (759.5) 13.60 (345.4) 635 (288) 291 EHD3090 EHD3100 24 8 80 600 Volts to 208Y/120 Volts 15 P60G28T15P 2-5% 36.10 (916.9) 28.80 (731.5) 9.40 (238.8) 320 (145) 289 FDB3030 EHD3050 18 6 40 22.5 P60G28T21P 2-5% 40.90 (1038.9) 29.90 (759.5) 13.60 (345.4) 565 (256) 290 FDB3050 EHD3070 18 6 60 30 P60G28T30P 2-5% 41.90 (1064.3) 29.90 (759.5) 13.60 (345.4) 635 (288) 291 FDB3070 EHD3100 24 8 80 1 Not for construction purposes. 2 Secondary main breakers fixed only. No substitutes for ampere rating. 3 Optional AIC rated main breakers available. See table on Page 3. 4 Combinations can be selected. 5 Feeder breakers not included. Use Cutler-Hammer Type BR family. EATON CORPORATION Dry-Type Transformers Mini-Power Centers 4

CATALOG NUMBER INFORMATION All-Copper Bolt-on Mini-Power Center (Copper-wound transformer and loadcenter chassis standard) Full Feeder Capacity Breakers 34 Style Taps Dimensions 1 Inches (mm) Weight Main Circuit Breaker 2 Max. Number Max. kva Number FCBN Height Width Depth Lbs. (kg) Frame Primary Secondary 1-Pole 2-Pole 3-Pole Amp Single-Phase 480 Volts to 120/240 Volts 3 P48G11S03CUB 2 @-5% 33.25 (844.6) 12.56 (319.0) 9.66 (245.4) 105 (47) 306 EHD2015 BAB2015 12 6 4 12 5 P48G11S05CUB 2 @-5% 36.14 (918.0) 12.56 (319.0) 9.66 (245.4) 110 (50) 307 EHD2020 BAB2025 18 9 6 20 7.5 P48G11S07CUB 2 @-5% 36.14 (918.0) 12.56 (319.0) 9.66 (245.4) 110 (50) 307 EHD2030 BAB2030 18 9 6 30 10 P48G11S10CUB 2 @-5% 40.85 (1037.6) 13.47 (342.1) 11.82 (300.2) 180 (82) 308 EHD2040 BAB2050 18 9 6 40 15 P48G11S15CUB 2 @-5% 43.91 (1115.3) 14.97 (380.2) 11.82 (300.2) 215 (98) 309 EHD2060 BAB2070 24 12 8 60 25 P48G11S25CUB 2 @-5% 43.37 (1101.6) 20.41 (518.4) 14.58 (370.3) 385 (175) 310 EHD2100 BAB2125 30 15 10 100 600 Volts to 120/240 Volts 3 P60G11S03CUB 2 @-5% 33.25 (844.6) 12.56 (319.0) 9.66 (245.4) 105 (47) 306 FDB2015 BAB2015 12 6 4 12 5 P60G11S05CUB 2 @-5% 36.14 (918.0) 12.56 (319.0) 9.66 (245.4) 110 (50) 307 FDB2020 BAB2025 18 9 6 20 7.5 P60G11S07CUB 2 @-5% 36.14 (918.0) 12.56 (319.0) 9.66 (245.4) 110 (50) 307 FDB2030 BAB2030 18 9 6 30 10 P60G11S10CUB 2 @-5% 40.85 (1037.6) 13.47 (342.1) 11.82 (300.2) 180 (82) 308 FDB2040 BAB2050 18 9 6 40 15 P60G11S15CUB 2 @-5% 43.91 (1115.3) 14.97 (380.2) 11.82 (300.2) 215 (98) 309 FDB2060 BAB2070 24 12 8 60 25 P60G11S25CUB 2 @-5% 43.37 (1101.6) 20.41 (518.4) 14.58 (370.3) 373 (169) 310 FDB2100 BAB2125 30 15 10 100 Three-Phase 480 Volts to 208Y/120 Volts 15 P48G28T15CUB 2 @-5% 36.12 (917.4) 28.75 (730.3) 9.38 (238.3) 320 (145) 289A EHD3040 BAB3050H 18 9 6 40 22.5 P48G28T21CUB 2 @-5% 40.88 (1038.4) 29.88 (759.0) 13.63 (346.2) 565 (257) 290A EHD3070 BAB3070H 18 9 6 60 30 P48G28T30CUB 2 @-5% 41.88 (1063.8) 29.88 (759.0) 13.63 (346.2) 635 (288) 291A EHD3090 BAB3100H 24 12 8 80 600 Volts to 208Y/120 Volts 15 P60G28T15CUB 2 @-5% 36.12 (917.4) 28.75 (730.3) 9.38 (238.3) 320 (145) 289A FDB3030 BAB3050H 18 9 6 40 22.5 P60G28T21CUB 2 @-5% 40.88 (1038.4) 29.88 (759.0) 13.63 (346.2) 565 (257) 290A FDB3050 BAB3070H 18 9 6 60 30 P60G28T30CUB 2 @-5% 41.88 (1063.8) 29.88 (759.0) 13.63 (346.2) 635 (288) 291A FDB3070 BAB3100H 24 12 8 80 1 Not for construction purposes. 2 Main breakers fixed only. No substitutes for ampere rating. 3 Combinations can be selected. 4 Feeder breakers not included. Use Cutler-Hammer Type BAB family. EATON CORPORATION Dry-Type Transformers Mini-Power Centers 5

Eaton s electrical business is a global leader in electrical control, power distribution, and industrial automation products and services. Through advanced product development, worldclass manufacturing methods, and global engineering services and support, Eaton s electrical business provides customerdriven solutions under brand names such as Cutler-Hammer, Powerware, Durant, Heinemann, Holec and MEM, which globally serve the changing needs of the industrial, utility, light commercial, residential, and OEM markets. For more information, visit www.eatonelectrical.com. Eaton Corporation is a diversified industrial manufacturer with 2005 sales of $11.1 billion. Eaton is a global leader in electrical systems and components for power quality, distribution and control; fluid power systems and services for industrial, mobile and aircraft equipment; intelligent truck drivetrain systems for safety and fuel economy; and automotive engine air management systems, powertrain solutions and specialty controls for performance, fuel economy and safety. Eaton has 60,000 employees and sells products to customers in more than 125 countries. For more information, visit www.eaton.com Eaton Electrical Inc. 1000 Cherrington Parkway Moon Township, PA 15108 United States tel: 1-800-525-2000 www.eatonelectrical.com NEMA is the registered trademark and service mark of the National Electrical Manufacturers Association. National Electrical Code and NEC are registered trademarks of the National Fire Protection Association, Quincy, Mass. Cutler-Hammer is a federally registered trademark of Eaton Corporation. UL is a federally registered trademark of Underwriters Laboratories Inc. CSA is a registered trademark of the Canadian Standards Association. ISO is the registered trademark and sole property of the International Organization for Standardization. 2006 Eaton Corporation All Rights Reserved Printed in USA Publication No. BR00904003E / Z4780 September 2006