INSTALLATION MANUAL OF EZINC OPEN LOOP THERMO SIPHON SOLAR WATER HEATING SYSTEMS

Similar documents
SOLAR ENERGY SYSTEMS. PV Energy Systems & Solar Thermal Systems

SUNRAIN SOLAR HEAT PIPE COLLECTOR TZ58/1800- R SERIES

GASOKOL vacutube. GASOKOL GmbH, vacutube_de 1 von 5

Making the World a Better Place

Fact Sheet Sky CPC 58

Technical Product Submittal

U Q He y ys. UniPlate. Solar Collectors

For our present, For their future. Version 11.03

DS Series Solar System

Product Catalog Evacuated tube collectors CPC OEM CPC w OEM

Innovo Condensing high efficiency water heater

HD [ GB ] Tipping bucket rain gauge

SEALA. Dust & Moisture Proof Luminaire

Solar Collector Product Specifications

SOLAR HEATING SYSTEM

Example printout. Building project. SDC Example. Dyfi Eco Park SY20 8AX Machynlleth UK. Mr C. Laughton Phone:

One system. One company.

WHISPERPOWER GENERATOR SETS

SOLAR THERMAL Forced circulation solar thermal system with selective flat plate collectors SELECTIVE SLIM

Evacuated tube collectors

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

BHW MEDIUM STATIC PRESSURE DUCTABLE TYPE TECHNICAL CATALOGUE

Zhejiang Ejai Kitchen & Bath Technology Co., ltd

Heat Exchangers. Evaporator Catalogue

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

PVE /117 ED VARIABLE DISPLACEMENT VANE PUMPS WITH DIRECT PRESSURE ADJUSTMENT SERIES 30 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS

Wall-hung electric storage water heater POLYURETHANE INSULATION IP25

SOLAR COLLECTORS. Excellent efficiency, the best characteristics, high quality. The highest efficiency. More power.

SDHW System Inspection Form

SPLIT SOLAR HEATER SWSP-200 SWSP-300

Results of annual simulation

Ariston Thermo S.p.A Keymark lic.no. if available - Company. Store name. length. width. Gross CNA150HF CNA200HF CNA300HF. Company. Name.

General Catalogue TECHNICAL INFORMATION

Revision THERMO TECHNOLOGIES. USDT 2001 Differential Controller. Installation and User s Guide

INSTALLATION & OPERATION MANUAL

PCXAU1601. VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ. Heat Pump 50/60 Hz R-410A

GH Hydro Kits. Technical Information. Ref: N

Technical Features. Material. Finish. Inner Depth (d1) mm 42U ,6 CPI42-X-4266A

DIN CERTCO Alboinstraße Berlin Tel: Fax:

Non-Imaging Concentrator based Solar System Operations & Maintenance Manual

MANUAL. Collector FK7300. Mounting parallel roof bracket attachment system

TECHNICAL DESCRIPTION. SPLxx-W. version 2017_01

CENTRIFUGAL FAN COIL UNIT VCE

Integrated temperature test and calibration bench Model CBS-SC4000

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C)

Küba SG industrial

TRIC A On-Roof Installation for EURO- Collectors*

Schüco Premium Collectors Outstanding quality, performance and design

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

No Q/LX.S.E Edition A/0. Expocell Group, Inc. Cylindrical Li/MnO 2 Battery. Specification. Battery Type: CR123A(CR17345) Customer.

Annex to Solar KEYMARK Certificate

STRAIGHT PERFORATED TRAY

TECHNICAL CATALOGUE SELF CONTAINED HORIZONTAL AIRCONDITIONERS Rev105

Climas y Proyectos Leyco, S.A. de C.V.

SOLAR CHARGE CONTROLLER

INSTALLATION AND OPERATION MANUAL

enviko solar product brochure

Version For our present, For their future.

Filing frame Basic-Line

DIN CERTCO Alboinstraße Berlin Tel: Fax:

(UK) Date : January 2014

PCXDMT1601. VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ. Heat Pump 50/60 Hz R-410A

available in battery up to 4 units for a total of 560 kw

Already from ** about: 60,- /m². Collector-width about 2,0 m. solar area about m². rows of retaining frames. Collector-width about 3,5 m

Qty: L50 50W. B4 Two 12V 146 Ah. B5 One 12V 176 Ah. P4 150W Double. 4 XXX 4 hours PM 0 hours AM. 5 XXX 6 hours PM 0 hours AM PM4 45 PM6 60.

Solar inverter AX-series

Manual CPK 7210 N. Flate plate collector. Mounting parallel bench srew mountingsystem x x x x / version

AHN 064 to 304 EHN/CHN 064 to 304

ACCESSORIES FOR SZE2 CABINETS

ELTAFANTECH Air Handling Unit 700 up to 42,000 CFM

SAFETY EQUIPMENT VOLTAGE DETECTORS. PHE Voltage Detector Nominal voltages up to 30 kv / 50 Hz

AV 23 Balancing valves SETTER Inline

Test Report: KTB Nr k. Mechanical load test up to 2400 Pa according to EN :2002. for: IFF Kollmannsberger KG

OVENS & INCUBATORS RESPONSE TO THE DEMANDS OF MODERN LABORATORY. INCUBATORS from 5 to 240 lt. OVENS from 5 to 720 lt

something new in the air Technical Bulletin

CLIMA CANAL HYBRID HEATING AND COOLING CLIMA CANAL. Compact floor recessed fancoil unit HEATING

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

HEATING & COOLING SYSTEMS WALL HUNG BOILERS RADIATORS WATER HEATERS CENTRAL HEATING SYSTEMS AIR CONDITIONERS

CONTINUOUS CAPACITY CONTROL MODELS

OPERATION AND INSTALLATION

Annex to Solar KEYMARK Certificate

INDEX. 3 BOREHOLE DC SOLAR PUMPS 3LLS...4 PERIPHERAL VANE DC SOLAR PUMP 3LSQB2...6

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

Automatic Roof Door Vents

TECHNICAL CHARACTERISTICS: Structure : upright type, realized in sheet steel epoxy coated white colour both in- and outside or in stainless steel

Spark arrestor type C

Cabinets Outdoor. Optimal protection from vandalism thanks to a fixing accessible only from within. Easily exchangeable exterior cladding components.

Küba Green Line XXXXXXXXXX. Küba market plus SP. High Performance Unit Cooler.

Küba Green Line. Küba comfort DP. Ceiling Air Cooler.

483 mm (19 ) Wall Mounting Cabinets IP55 (Outdoor), 600 mm width mm, 600 mm depth

4 Stroke Diesel. Oil type SAE 15 W40/E 3

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

Catalog Little Champ Hydraulic Power Unit Kits

Type Operating Instructions. Bedienungsanleitung Manuel utilisateur

Plate Heat Exchangers

1000 Series 6TWGM Marine Auxiliary Engine kw (195.7 hp) gross prime 1800 rpm

TORK DIESEL FILTER/WATER SEPARATOR

HCA-58/20(30) SOLAR COLLECTOR INSTALLATION MANUAL

TECHNICAL APPLICATIONS. Metalpak Sb200

Transcription:

INSTALLATION MANUAL OF EZINC OPEN LOOP THERMO SIPHON SOLAR WATER HEATING SYSTEMS 1) INTRODUCTION 2) GENERAL FEATURES 3) OPERATION INSTRUCTIONS 4) SUPPORT BASE AND MOUNTING STEPS 5) FITTINGS & CONNECTIONS

1) INTRODUCTION Thank you very much to prefer high quality, long-term durable and efficient EZINC solar thermal systems. Important notice: Please read this manual carefully before starting installation of solar water heater. This solar water heating system is working according to the natural circulation (thermo siphon principle). General These instructions describe mounting and installation of thermo siphon solar water heaters. All installations must be done by authorized staff. Please read these instructions carefully before starting the installation. If you do not suit to the instructions, product will be out of any guarantee. Position of the system Thermo siphon solar water heaters are able to convert the maximum solar energy to the heat, when the cover of the collector faces to the south. Local climatic conditions, wrong installation, inclination of the collector according to the coordinates of the location may effect the performance of the system. Transportation During transportation and installation you should pay attention to the following points: - Protect the glass and the back sheet of solar collectors from damages. - Do not put heavy materials on the collectors which can cause any damage. Protection recommendations During the installation, please cover the glass side of the collector with a nontransparent blanket which will avoid transmittance of the direct sunlight into the collector. Maintenance requirements To get the maximum efficiency from your thermo siphon solar water heater and to increase its lifetime, please check the following points annually: - Check the hydraulic connections. Important notice: If necessary, please install a pressure reducer between cold water inlet of the tank and main supply to avoid any problems because of high pressure of main supply. Our kit package is not including pressure reducer. 2) GENERAL CHARACTERISTICS 2

Collector specifications: COLLECTORS M XBA L XBA M USB L USB HEIGHT 1727 1891 1727 1891 DIMENSIONS (mm) WIDTH 1204 1204 1204 1204 DEPTH 99 99 99 99 WEIGHT 36 kg 41 kg 36 kg 41 kg GROSS COLLECTOR AREA (sqm.) 2,08 2,28 2,08 2,28 NET ABSORBER AREA (sqm.) 1,96 2,12 1,96 2,12 MANIFOLD TUBES COPPER Ø25 mm COPPER Ø25 mm COPPER Ø25 mm COPPER Ø25 mm RISER TUBES COPPER Ø16 mm COPPER Ø16 mm COPPER Ø12 mm COPPER Ø12 mm ABSORBER SHEET ALUMINIUM ALUMINIUM COPPER COPPER SURFACE COATING BLACK SOLAR PAINT BLACK SOLAR PAINT BLUE SELECTIVE COATING BLUE SELECTIVE COATING CASING MATERIAL ELECTROSTATIC POWDER COATED ALUMINIUM PROFILE ELECTROSTATIC POWDER COATED ALUMINIUM PROFILE ELECTROSTATIC POWDER COATED ALUMINIUM PROFILE ELECTROSTATIC POWDER COATED ALUMINIUM PROFILE INSULATION POLYURETHANE POLYURETHANE POLYURETHANE POLYURETHANE GLASS TEMPERED SOLAR GLASS TEMPERED SOLAR GLASS TEMPERED SOLAR GLASS TEMPERED SOLAR GLASS GASKETS-SEALING EPDM EPDM EPDM EPDM 1 2 3 9 4 8 5 7 6 1- Glass profile 2- Glass sealing 3- Glass (frontal cover) 4- Absorber sheet 5- Absorber riser pipe 6- Insulation 7- Absorber manifold (header) pipe 8- Female connection fitting 9- Gasket Tank specifications: 3

Open loop (direct) tanks: MODEL AG-120 AG-170 AG-300 NOMINAL CAPACITY 120 LT 170 LT 300 LT TANK TYPE OPEN LOOP OPEN LOOP OPEN LOOP TANK DIMENSIONS DIAMETER 1270 1170 1810 (mm) LENGTH Ø 510 Ø 600 Ø 600 NET WEIGHT ~58 kg ~70 kg ~100kg INTERIOR TANK COATING GLASSLINE ENAMEL GLASSLINE ENAMEL GLASSLINE ENAMEL ELECTROSTATIC POWDER COATED ELECTROSTATIC POWDER COATED ELECTROSTATIC POWDER COATED OUTSIDE COVER MATERIAL GALVANISED STEEL GALVANISED STEEL GALVANISED STEEL DIRECT-INJECTED POLYURETHANE FOAM DIRECT-INJECTED POLYURETHANE FOAM DIRECT-INJECTED POLYURETHANE FOAM INSULATION MAX. OPERATION PRESSURE STORAGE TANK 8 BAR 8 BAR 8 BAR ELECTRICAL BACKUP HEATER 2 kw (OPTIONAL) 2 kw (OPTIONAL) 2 kw (OPTIONAL) PROTECTION AGAINST CORROSION MAGNESIUM ANODE BAR MAGNESIUM ANODE BAR MAGNESIUM ANODE BAR 3) INSTALLATION & OPERATION INSTRUCTIONS 4

4) MOUNTING SET AND MOUNTING STEPS SUPPORT BASE FOR FLAT ROOF INSTALLATION: 5

5 2(b) 7 3(b) 6 8 1(b) 2(a) 4 6 DIMENSION PCS PART NO 1(a) 45 30cm 60cm 7 1318,5mm 8 Figure:2 30 mm 12 30 mm 4 40 mm 8 2640 mm 2 1550 mm 2 8 7 6 5 4 1385 mm 2 3 1950 mm 2 2 1400 mm 2 1 1 2 6

3 4 5 6 7 8 7

ANGLE ROOF INSTALLATION MOUNTING STEPS 8

5) FITTINGS & CONNECTIONS - Pressure relief (safety) valve for storage tank - Insulated connection pipes between tank and collector(s) - Other fittings IMPORTANT POINTS ABOUT INSTALLATION AND OPERATION OF THERMOSIPHON SOLAR WATER HEATERS 9

1. You must be sure that the tank is filled with water.otherwise system starts to operate and can damage the tank as it is empty. Also cover the glass of collector(s) during installation with a matt blanket to avoid heating up the system before filling. 2. Collector(s) must be installed according to the direction of UP label. 3. 3 bar solar pressure relief valve must be installed on the primary circuit to avoid problems during operation because of over temperature and over pressure. 4. 8 bar pressure relief valve must be installed before the cold water inlet of the tank and after one-way valve to protect the tank from over pressure of the water from the main supply. 5. Primaryt circuit must be filled completely by discharging the air inside the collector, and pipes. 6. Flat roof mounting sets must be installed on a flat ground and profiles parallel to the ground must contact completely with the ground. 7. Inlets and outlets axis of the tank must do a 90 degrees angle with the ground axis, otherwise system can have problems during operation. 8. All pipes between tank and collector, and connection pipes of the SWH to the house should be insulated to have the best efficiency and performance from the system. 9. Tanks must be handle and install with care. Any damages to tank can cause break of the glassline coating inside, which will cause corrosion inside from the damaged coating points. 10. Oxidation can be seen on the galvanised parts of mounting sets, if the installation done very close to the sea or humid areas. 11. Wrong and improper installations can cause accidents, damages, etc. therefore be sure that installation done by a qualified installer, properly. 12. Magnesium anode bar is a sacrificial part which protects the tank coating inside against corrosion. It should be checked annually and if it is finished, must be replaced with a new one. Please contact us or your dealer for original magnesium anode bars. 13. Pressure relief valves, one-way valves must be checked annually and if they are out of order, must be replaced with a new one. 14. These systems operate with pressurized water, therefore be sure that main water supply has a pressure of minimum 3 bars. EZINC Metal San. Tic. A.S. Address: OSB 23. Cad. No: 31 TR-38070 Kayseri TURKEY Tel: +90-352-3211321 Fax: +90-352-3211325 e-mail: sales@ezinc.com.tr www.ezinc.com.tr 10