Corso Principi di Piemonte, 65/ RACCONIGI (CN) ITALY tel fax

Similar documents
CICLÓN ATTUATORE ELETTROMECCANICO IRREVERSIBILE A BRACCIO SNODATO PER CANCELLI A BATTENTE

TURBO 40 TURBO 80 TURBO 120 TURBO 160

Installation manual ASTER AUTOMATION FOR SWING GATES 11_16

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

UNDERGROUND OPERATOR FOR SWINGING GATES. WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack

MASTIFF 300/300M SWING GATE OPENER USER MANUAL

WEL. Manuale di installazione e manutenzione per automazioni per porte battenti. Installation and maintenance. for swing doors.

IRREVERSIBLE OPERATOR FOR SWING GATES AND DOORS

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

PW150/PW200 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR

PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL. Flashing Light. Push Button. Control box. Gate 2.

Ditec LUXO Swing gates automation (Original instruction)

Istruzioni, instructions. Motoriduttore a braccio snodato per cancelli battenti Gear motor with articulated arm for swing gates ALPHEO

ARACHNE 230V 24V- 12V

AUTOMATION SYSTEM FOR SWING GATES FROG SERIES INSTALLATION MANUAL SUPERFROG

E R A I GATE AUTOMATION DIVISION

GROUND GROUND - ( ) Interrati elettromeccanici ISTRUZIONI PER L INSTALLAZIONE. Electromechanical underground INSTRUCTIONS FOR INSTALLATIONS

Automation Swing Gate Opener

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES

MEKO OPENER FOR RACK-DRIVEN SLIDING MOTOR

SWING GATE OPENERS 24V DC GEAR MOTOR

INSTRUCTIONS FOR INSTALLATION

BISON 20 OM BISON 25 OTI

Installation manual. English. mystrike OPENER FOR RACK-DRIVEN SLIDING MOTOR

L /2012 rev 0 BISON 45 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

BULL 424 ESA BULL 624 ESA

BULL 5M - BULL 5M.S BULL 8M - BULL 8 M.S BULL 8 OM - BULL 8 OM.S

SARGON S - M - L. All rights reserved INSTALLATION MANUAL

L /2013 rev 0 BISON 35 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

L /2012 rev 0 BISON 30 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

INSTALLATION MANUAL ACE. Gearmotor for swing gates 01_17

INSTALLATION MANUAL ENGLISH ALPHA 200 ALPHA 330. L C (stroke) 960 mm 1160 mm

IN-GROUND OPERATOR FOR SWING GATES FROG SERIES INSTALLATION MANUAL FROG-A 230V

Cross14, Cross14E, Cross14VE, Cross15V

BL240 BL240 - (15400) Operatore elettromeccanico lineare ISTRUZIONI PER L INSTALLAZIONE

USER INSTRUCTIONS FOR SLIDING DOORS

ARTICULATED ARM GATE OPENER USER MANUAL

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC) WARNINGS FOR THE INSTALLER

Ditec DOD Industrial sectional door automations

HYDRAULIC SWING GATE OPENER

Installation Manual. Swing Gate System. Leading the way...

Porte 150 Users Manual Swing Gate Opener 24V DC

PERSA 400 USER S AND INSTALLER S MANUAL V1.0 REV. 10/2016

Contents. EC DECLARATION OF CONFORMITY FOR MACHINES... p. 10. WARNINGS FOR THE INSTALLER... p. 10

Ditec CUBIC Swing gates automation

Ditec BOX Balanced up and over doors

IGEA LB INSTALLATION AND USER'S MANUAL. MONTAGE- und BEDIENUNGSANLEITUNG INSTRUÇÕES DE USO E DE INSTALAÇÃO

CITY1 CENTRALE DI COMANDO DIGITALE PER CANCELLI AD ANTA E SCORREVOLI DIGITAL CONTROL UNIT FOR LEAF SWING AND SLIDING GATES

MOUNTING AND CONNECTING INSTRUCTIONS 1. GATE ARRANGEMENT ENGLISH

Nice TTN3724HS TTN3724RHS TTN6024HS TTN6024RHS

SUBWING 700 USER S AND INSTALLER S MANUAL V1.0 REV. 04/2017

Ditec PWR50H/HV/HR Automation for swing gates

Ditec PWR25H/35H Automation for hinged gates

is250/is250d/is250solar SWING GATE OPENER MANUAL

TECHNICAL DATA HYDRAULIC UNIT

Porte 300 Users Manual Swing Gate Opener 24V DC for residential use only

EC DECLARATION OF CONFORMITY FOR MACHINES WARNINGS FOR THE INSTALLER

INSPECTIONS AND MAINTENANCE

UNDERGROUND OPERATOR FOR SWING GATES 119AS45EN. Installation manual FROG-A / FROG-AV / FROG-AE. English

VIS IRREVERSIBLE ELECTROMECHANICAL MOTOR FOR SECTIONAL DOORS. Rev /2011 RT

Jet. Gear motor for swing gates MADE IN ITALY INSTRUCTION MANUAL

blue garda blue roll blue roll EAsy blue micro blue micro EAsy moteurs tubulaires motores tubulares Serie - Series - Baureihe - Série - Serie

INSTALLATION MANUAL FOR SWING SHUTTERS KAF212. FACE S.r.l. Viale delle Industrie, Dosson di Casier Treviso Italy

ASW-400. Installation Manual. Downee

CAUTION CM-SE CM-S21 CM-S41

CE DECLARATION OF MACHINE CONFORMITY

Rex. Manuale di installazione e manutenzione per porte scorrevoli. Installation and maintenance manual for sliding door

FITTING AND CONNECTION INSTRUCTIONS

Automations for garage doors and rolling shutters

Multi-Mover Charger for model L25

SWING GATE OPENERS 24V DC GEAR MOTOR

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC)

F ERNI K I T THE FERNI-S KIT CONSISTS OF:

SLIDING GATE OPENER USER MANUAL

PERSA 400 USER S AND INSTALLER S MANUAL V3.1 REV. 10/2018

SLIDE & OL USER'S AND INSTALLER'S MANUAL V1.0 REV. 06/2017

LINCE 300/400/600. User s and Intaller s manual

BIG Series. D_MNL0BIG Rev.18. IT - Istruzioni originali

EC DECLARATION OF CONFORMITY

INSTALLATION AND OWNER S MANUAL MODEL ASW Actuator Swing Gate Operator

SLIDE NEW CONTROL BOARD

GB Instructions Manual

FEATURES AND SPECIFICATIONS

Ditec QIK80EH Electromechanical barrier. IP2085EN Technical Manual. (Original instructions)

Mod: KLD6-12/35XLAS-N

OBBI3BH. Manuale di installazione e manutenzione per automazioni per cancelli a battente. Installation and Maintenance manual for swing gates.

PCS. Proof of closure switch for safety gas valves. delta-elektrogas.com EE

IP2160 EN. Ditec NEOS Sliding Gates. Technical Manual. (Original instructions)

Electromechanical gear motor for sliding gates ACHILLES

Ditec CROSS18-19 Sliding gates automation. IP1984 EN Technical Manual. (original instructions)

BAYT 980. Oil-hydraulic OIL-HYDRAULIC BARRIER FOR TRAFFIC CONTROL INSTALLATION MANUAL. code 4425 Post with fixing base. POLO 44 - optional -

Automatic concealed bollards 275 H600 and 275 H800 with pit

ECO PLUS RAPID DOOR USER S AND INSTALLER S MANUAL

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

V200 USER MANUAL SWING GATE OPENER. 100kg 1.5m. 100kg 1.5m

Ditec PWR Automation system for swing gates with wings up to 5 metres

USER S MANUAL. Installation, Operation, & Maintenance

Position Limit Switches PLTA

JOINT INSTALLATION MANUALS AND SAFETY INFORMATION

ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS

Transcription:

V2 S.p.A. Corso Principi di Piemonte, 65/67 12035 RACCONIGI (CN) ITALY tel. +39 01 72 81 24 11 - fax +39 01 72 84 050 info@v2home.com - www.v2home.com IL n.131 EDIZ. 28/08/2012 Bingo I GB F E P D NL ATTUATORE ELETTROMECCANICO IRREVERSIBILE PER CANCELLI A BATTENTE IRREVERSIBLE ELECTROMECHANICAL ACTUATOR FOR SWING GATES OPERATEUR ELECTROMECANIQUE IRREVERSIBLE POUR PORTAILS BATTANTS OPERADOR ELECTROMECÁNICO IRREVERSIBLE PARA CANCELAS BATIENTES ACTUADOR ELECTROMECÂNICO IRREVERSÍVEL PARA PORTÕES DE BATENTE NICHT UMKEHRBARER ELEKTROMECHANISCHER ANTRIEB FÜR FLÜGELTORE ELEKTROMECHANISCHE, ONOMKEERBARE LINEAIRE MOTOR VOOR HEKKEN MET VLEUGELS

IMPORTANT REMARKS For any installation problem please contact our Customer Service at the number +39-0172.812411 operating Monday to Friday from 8:30 to 12:30 and from 14:00 to 18:00. For correct installation of the system, we recommend following the instructions issued by UNAC very carefully, which can be consulted at the following web site: www.v2home.com V2 has the right to modify the product without previous notice; it also declines any responsibility to damage or injury to people or things caused by improper use or wrong installation. m Please read this instruction manual very carefully before installing and programming your control unit. This instruction manual is only for qualified technicians, who specialize in installations and automations. The contents of this instruction manual do not concern the end user. Every programming and/or every maintenance service should be done only by qualified technicians. AUTOMATION MUST BE IMPLEMENTED IN COMPLIANCE WITH THE EUROPEAN REGULATIONS IN FORCE: EN 60204-1 EN 12445 EN 12453 (Machinery safety electrical equipment of machines, part 1: general rules) (Safe use of automated locking devices, test methods) (Safe use of automated locking devices, requirements) DECLARATION OF CONFORMITY The following statement is applicable only if the below listed equipments are employed in accordance with the purpose indicated in the instruction manual. Company: V2 SPA Corso Principi di Piemonte 65 12035 RACCONIGI -ITALY Tel. +39 01 72 82 10 11 Fax +39 01 72 82 10 50 Contact person: Cosimo De Falco Chief Executive Officer V2 SPA declares that the series of BINGO actuators are in conformity with the provisions of the following EC directives: 73/23/EEC 89/366/CEE 98/37/EEC low voltage directive electromagnetic compatibility directive machine directive Note: Declares that the above mentioned devices may not be operated until the machine (automated gate) is identified, CElabeled, and declared to be compliant to the specifications of Directive 89/392/EEC and following modifications. The installer must provide for a device (es. magnetotermical switch) ensuring the omnipolar sectioning of the equipment from the power supply. The standards require a separation of the contacts of at least 3 mm in each pole (EN 60335-1). The plastic case has an IP55 insulation; to connect flexible or rigid pipes, use pipefittings having the same insulation level. Installation requires mechanical and electrical skills, therefore it shall be carried out by qualified personnel only, who can issue the Compliance Certificate concerning the whole installation (Machine Directive 98/37/EEC, Annex IIA). The automated vehicular gates shall comply with the following rules: EN 12453, EN 12445, EN 12978 as well as any local rule in force. Also the automation upstream electric system shall comply with the laws and rules in force and be carried out workmanlike. The door thrust force adjustment shall be measured by means of a proper tool and adjusted according to the max. limits, which EN 12453 allows. We recommend to make use of an emergency button, to be installed by the automation (connected to the control unit STOP input) so that the gate may be immediately stopped in case of danger. The appliance is not to be used by children or persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction. Children being supervised do not play with the appliance. The person in charge for the machine start-up must provide the following records: Technical specification paper Declaration of conformity CE-labeling Testing record Maintenance record Operation manual and directions Racconigi 20/10/2009 V2 SPA legal representative Cosimo De Falco PREPARATORY STEPS The new series of actuadors BINGO, has been devised to serve gates up to 500 Kg with leaf up to 5 meters wide (look at the table technical data). Before proceeding with the installation, please make sure that your gate opens and closes freely, and that: Hinges and pins are in optimum condition and properly greased. No obstacles are within the moving area. There is no friction with the ground or between the leaves. Your gate is equipped with a central latch. 7

TECHNICAL DATA BINGO400 - BINGO500 - BINGO400-120V - BINGO500-120V BINGO400-24V - BINGO500-24V Opening and closing mechanical stop BINGO400 02- BINGO500 02 BINGO400 BINGO400 02 BINGO400 120V Opening and closing mechanical stop Opening and closing electrical limit switch Built-in trigger capacitor BINGO500 BINGO500 02 BINGO500 120V BINGO400 24V Max. leaf lenght m 3,5 3,5 5 5 3,5 5 BINGO500 24V Max. leaf weight Kg 400 400 500 500 350 400 Power supply VAC - Hz 230-50 120-60 230-50 120-60 24 VDC 24 VDC Idling current A 2 4 2 4 1,8 1,8 Full load current A 3,2 6 3,2 6 5 5 Maximum Power W 480 480 480 480 120 120 Capacitor µf 8 2 x 10 8 2 x 10 - - Max travel mm 370 370 490 490 370 490 Operating speed m/s 0,017 0,018 0,017 0,018 0,010 0,018 Maximum thrust N 1800 1800 1800 1800 1800 1800 Working temperature C -30 +60-30 +60-30 +60-30 +60-30 +60-30 +60 Protection IP 34 34 34 34 34 34 Working cycle % 30 30 30 30 80 80 Motor weight Kg 11 11 12 12 11 12 INSTALLATION LAYOUT BINGO actuator cable 4 x 1 mm 2 Blinker cable 2 x 1,5 mm 2 Aerial cable RG-58 Key or digital selector cable 3 x 0,5 mm 2 Safety edge (EN 12978) - Internal photocells External photocells cable 4 x 0,5 mm 2 (RX) cable 2 x 0,5 mm 2 (TX) cable 4 x 0,5 mm 2 (RX) cable 2 x 1 0,5 mm 2 (TX) Control unit cable 3 x 1,5 mm 2 8

INSTALLATION MEASURES To carry out a proper installation of the operator parts as well as to ensure the best automation performance, the measurement levels shown in the following table shall be complied with. Change the gate structure to adapt it to one of the cases in the table, if necessary. m WARNING: In the case of leaf longer than 2,5 metres, an electric lock must be fitted to ensure an efficent closig. m WARNING: In order to avoid contatcts of the operator against the shutter, it is necessary to keep as much exactly as possible the height D taking into consideration a margin between 0 and +5mm. BINGO400 γ A [mm] B [mm] C [mm] D [mm] E [mm] 90 100 20 140 130 120 695 30 150 160 140 665 40 160 160 140 665 50 170 160 140 665 60 180 150 140 675 70 190 150 120 675 80 200 140 120 685 90 210 130 120 690 100 220 125 120 695 110 210 130 120 690 20 140 165 120 660 30 150 160 120 660 40 140 160 120 660 50 150 160 120 660 60 160 155 120 660 70 160 145 110 670 BINGO500 γ A [mm] B [mm] C [mm] D [mm] E [mm] 90 100 110 40 160 150 140 795 50 170 150 140 795 60 180 160 140 785 70 190 160 140 785 80 200 160 140 785 90 210 160 140 785 100 220 160 140 785 110 230 160 140 780 120 240 160 140 780 130 250 160 140 780 140 260 160 140 780 150 270 150 140 790 160 280 150 140 785 40 160 190 140 755 50 170 190 140 755 60 180 190 140 755 70 190 190 140 755 80 200 190 140 755 90 210 190 140 755 100 220 190 140 755 110 230 185 140 760 120 220 190 140 750 130 230 185 140 755 40 160 220 140 725 50 170 220 140 725 60 180 220 140 725 70 170 210 130 730 80 180 205 130 735 9

ACTUATOR FIXING Choose measures referring to the table you can find in the previous page, mark them on the pillars and continue as follows: Fix brackets on the pillars and on the gate. Close the swing. Unlock the actuators. Position BINGO on the brackets and fix the pin no. 1 with self-locking nut (see the picture). Insert the ring nut 2, paying attention to the side of the entrance. m WARNING: inserting the ring nut n. 2 in the opposite side would be very difficult because of the conicity of the hole and the bush 3. An over forcing may cause the damage of some components. Once inserted correctly the ring nut 2, fix it on the bush 3 using the screw 4 with its self-blocking nut. Close the self-blocking nut before hand moving the leaves. Try more times to hand open and close the leaves, checking that there are no frictions between the actuator and the structure of the gate. Make that the hole for the fastening of the screw n. 4 is on the lower side. 10

LIMIT SWITCH ADJUSTMENT Versions WITHOUT electric limit switch To adjust the limit switch, please do as follows: Open the swing as much as possible and position the mechanical stop no. 1 in contact with the female screw. Fasten the mechanical stop fixing the bolt using a 13 mm spanner. Move the leave in closing position, then position the mechanical stop 2 next to the nut (keep a distance of at least 5 mm). m PLEASE NOTE: Stop No. 2 must only be used for installations with no closure stop, or to intervene as a result of over-running under emergency conditions. Where the door has a mechanical stop, avoid setting stop No. 2 at the female screw end-stop when the gate is closing. The female screw could seize in such a way as to make it very difficult to release the Bingo. Versions WITH electric limit switch As regards models equipped with electrical limit switches, the female screw stops 5mm before the mechanical stop; the electrical limit switch (already wired inside the motor) interrupts the motor power supply, to avoid unusefull stress and overheatings. To adjust the limit switch, please do as follows: Open the swing as much as possible and position the mechanical stop no. 1 in contact with the female screw. Fasten the mechanical stop fixing the bolt using a 13 mm spanner. Close the swing as much as possible and position the mechanical stop no. 2 in contact with the female screw. Fasten the mechanical stop fixing the bolt using a 13 mm spanner. Fasten the mechanical stop fixing the bolt using a 13 mm spanner. 11

ELECTRICAL CONNECTIONS Unscrew A, pull the connector out of the motor, remove the gasket B, open the connector levering with a screwdriver in the slot C provided for this purpose. As regards 230 V BINGO and 120 V BINGO installed on the right swing, please connect the terminals as follows: 1 Closing cable, 3 Common cable 2 Opening cable, Earth wire 24 V BINGO require connection of the connector terminals no. 1 and no. 2 with the control unit terminals + and. Remember to connect the earth wire with the terminal. As regards BINGO installed on the left leaf invert cables on terminals no. 1 and no. 2. Replace the gasket B, insert the connector, bolt the screw A, and check the correct functioning of the automation. m WARNING: Always remember to connect the earth according to current standards (EN 60335-1, EN 60204-1). Do not use cables with diameter above 10 mm. If the feeder is damaged, a replacement must be effected from licensed and qualified personnel. EMERGENCY RELEASE In case of a blackout, the gate can be operated directly from the motor. Insert the key supplied in the lock, per--form 1/4 of a turn and open the plastic door completely. To restore the automation, simply close the door, rotate the key in closed position and slide the specially provided plastic cover onto the lock. 12