Compact Integrated Distribution Substation (CIDS)

Similar documents
COMPACT SUBSTATION GUIDE

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS

TGK Prefabricated Substation Technical Data

Key features. DESIGNS: - Conservator type - Hermetically sealed

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

SafeLink The Ultimate RMU. Rex de Bruyn PTMV New Zealand. ABB Ltd - Page 1 ABB

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

EMPAC Metal enclosed capacitor bank for wind applications

24kV Medium Voltage Switchgear Metal-Enclosed (LSC2A)

tests Partial discharge level from day 1 10 pc Insulation 24 kv : impulse tested at 125 kv Insulation 36 kv : impulse tested at 170 kv, 200 kv indeed.

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

NXPLUS C Single busbar. Maintenance-free for lifetime

56-SDMS-07 REV. 01 SPECIFICATIONS FOR

Medium Voltage Metal-Enclosed Switches

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system.

MESG 12 / 17.5 / 24 / 36 KV

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

Extensible Unit - VCE2a

Single phase pole mounted. 11kV. Electrical Engineer KEU ID#:

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

Medium Voltage Metal-Enclosed Switches

Technical Specification of GECOL. Packaged Transformers

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

Figure 1. Two and Three-phase MagneX.

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

with Vacuum Circuit Breaker HAF

abb SafeLink SF 6 Insulated Ring Main Unit Installation and Operating Instructions Switchgear Division Auckland, New Zealand SLMIO ver 2.

SWITCHGEAR DIVISION PRODUCT PROFILES

8DJ. Maintenance-free for lifetime

1500 kva Pad Mount Transformer GRDY/14400V Primary - 208Y/120 Wye Secondary - Oil Cooled

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED)

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Power Voltage Transformers for Air Insulated Substations

Fusing Equipment. Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly GENERAL INSTALLATION

GROUP D. Switch & Protective device.

ZX-Family Gas-insulated medium voltage switchgear

Minera. Oil distribution transformers up to kva. eco design. Minera at a glance. Standards

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

High-Voltage Fuse Links according to IEC

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

Metal Clad Switchgears

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance

NEXT STEP B) SAFETY :

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Outdoor Distribution (15 kv through 25 kv) S&C Fault Tamer Fuse Limiter

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

LCL FILTERS INSTRUCTIONS MANUAL (M A) (c) CIRCUTOR S.A.

COMPACT AND EXTENSIBLE RING MAIN UNIT. insulated Ring Main Unit with load break switch or integrated vacuum circuit breaker

S&C Fault Tamer Fuse Limiter. Outdoor Distribution (15 kv through 25 kv)

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

UniGear. Technical Guide

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

SF 6. -insulated Ring Main Unit, SafeRing 36 and -insulated Compact Switchgear SafePlus kv ABB

Modular medium-voltage switchgear. NorMax

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

500 kva Pad Mount Transformer V Delta Primary - 208Y/120 Secondary - NEMA 4X - Oil Cooled

GENERAL INFORMATION POLE MOUNT TRANSFORMER SINGLE PHASE PAD MOUNT TRANSFORMER SINGLE PHASE POLE MOUNT TRANSFORMER THREE PHASE 17

7.0 Technical Guarantee Specification of 60MVA, 132/33kV Mobile Substation. TECHNICAL DATA SCHEDULE 60MVA, 132/33 kv MOBILE SUBSTATION

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Unit

Gas-Insulated Switchgear. Type 8VN1 blue GIS up to 145 kv, 40 ka, 3150 A

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

INESING srl. MOBILE SUBSTATIONS Energy Solution. Energy Innovation. INESING srl Energy Innovation

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

Padmount Solid Dielectric Switchgear Catalog

Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC

RESIDUAL CURRENT CIRCUIT BREAKER

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

with Vacuum Circuit Breaker HAF

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

Combined instrument transformers

PLATINUM SERIES SWITCHBOARD METERS

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

Benefits, typical uses

Fusing Equipment. Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly GENERAL INSTALLATION

Distribution transformers Efficiency over life-cycle

Accelerate your grid modernization with smart RMUs. Ring main units with smart grid-ready feeder automation

ZX2 Gas-insulated medium voltage switchgear

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

AIR CORE REACTORS. Phoenix Electric Corporation

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

Transcription:

Compact Integrated Distribution Substation (CIDS)

1- INTRODUCTION SAVE SPACE 2.5m 2 footprint for CIDS up to 630kVA. SAVE THE ENVIRONMENT No SF6, No PCB. SAVE MONEY Save up to 50% from conventional package substation with housing. ENSURE SAFETY FOR PUBLIC No exposed live parts. ENSURE SAFETY FROM FIRE If filled with flame retardant fluid. 2

2- DESCRIPTION The CIDS is a compact fully integrated outdoor package substation with medium voltage equipment, transformer, and low voltage equipment. The package substation is completely manufactured and assembled ready for installation on site. It ensures a high level of protection against access to live parts with a protection degree of IP 54 according to IEC 60529. The operation and control is achieved from the front of the unit, with separate compartments for medium voltage and low voltage sections. Four lifting lugs located on the upper part enable the lifting of the complete unit easily. 2.1. Major Benefits 2.1.1. Compact design-reduced footprint Reduction of space requirement. Reduction of footprint. 2.1.2. Cost Savings Minimum installation and maintenance labor costs. Minimum civil work; no building or vault structure. No need for main low voltage circuit breaker. 2.1.3. Operational Integrity Components are assembled and tested as an integral unit at the factory. Access to all elements of control and protection in one casing. 2.1.4. Safety Live parts inside the secure enclosure are hidden from the public and environment. If filled with flame retardant fluid, risk of transformer fire is greatly reduced due to high fire and flash points. 2.1.5. Environmental Integrity Low profile design requires minimum real estate. Dielectric fluid replaces ozone-depleting SF6 gas, currently used in RMU switching modules. 3

2.2. Main Components 2.2.1. Enclosure Single compact enclosure housing the transformer, medium voltage and low voltage sections. The is designed to be installed outdoor, with a protection degree of IP 54 according to IEC 60529 2.2.2. Low voltage section This section can be designed and manufactured according to the needs of each customer. Basic equipment includes: Low voltage bushings Three current transformers Four outgoing circuits by fuse links Three ammeters One voltmeter + one selector switch Optional: Circuit breakers instead of fuse links Multifunction electronic meter 2.2.3. Medium voltage section It includes the following components: Plug-in bushings Two sectionalizing switches for incoming and outgoing lines with earthling facility Main interrupter for protection against overloads and secondary short circuits Backup fuses for protection against internal faults Tap changer for voltage control (off-load) Voltage presence indicators Hotstick for sectionalizing switch operation Optional: Earth fault and short circuit indicators 2.2.4. Transformer section It includes the core and the windings of the transformer. 4

Fig 1 Plug-in bushing Fig 2 Three phase load break sectionalizing switch Fig 3 Back-up current limiting fuse Fig 4 Main interrupter Plug-in bushing (Fig 1) Built in capacitive point for voltage presence detection. Three phase loadbreak sectionalizing switch (Fig 2) Make-Before-Break operation. Silver plated copper contacts. Open/Close/Earth positions. Back-Up current limiting fuse(fig 3) For transformer internal faults. Protects and isolates faulty equipment. Coordinated with main interrupter (4), gives full range of fault protection. Main interrupter (Fig 4) Current and temperature sensitive protective device. Protects from overloads and secondary faults. Three phase trip, externally resettable. Insulating fluid Standard mineral PCB free oil according to IEC 60296. Optional: fire resistant high fire point organic or synthetic fluid. 5

Fig 5 Lifting Lugs Fig 6 Name Plate + single line diagram Fig 7 Mimic and labels Fig 8 Three phase main interrupter 2.3. CIDS Single Line Diagram A Source 1 2 Closed Open Earth 3 4 Transformer Coil B Source LV Closed Open 5 LV Panel Earth 6

Fig 9 Off load tap changer Fig 10 LV porcelain bushings Fig 11 Medium voltage screened bushings Fig 12 Pressure relief valve Fig 13 Dielectric level indicator 2.4. Technical Data GENERAL Design ambient temperature 40 C Frequency 50Hz or 60Hz TRANSFORMER 250kVA 400kVA 630kVA Rated voltages Primary highest voltage 12kV /17.5kV/24kV Rated secondary voltage From 231V up to 433V Vector group Dyn11 Lightning impulse voltage (primary) 75kV/95kV/125kV Industrial frequency withstand during 1 min (primary) 28kV/38kV/50kV Off load tap changer (5 positions) ± 2x2.5% No load losses 445W 840W 920W Load losses 2715W 3950W 6020W Short circuit impedance 4.00% 4.00% 4.00% ACCORDING TO IEC 60076 STANDARD MEDIUM VOLTAGE Rated short duration admissible current Sectionalizing switch for input-output and ground Highest voltage level Rated direct current Fuses Highest voltage level Maximum interrupting current Plug-in bushings, 6 in loop Highest voltage level Rated direct current ACCORDING TO IEC 60298 STANDARD 16kA 12kV /17.5kV/24kV 630A for 12kV primary 400A for 17.5kV and 24kV primary 24kV 50kA rms 24kV 630A LOW VOLTAGE Rated voltage Rated current Short time current (1s) Earthing Industrial frequency withstand during 1 min Lightning impulse withstand test ACCORDING TO IEC 60439 STANDARD From 231V up to 433V Up to 1000A (according to transformer rating) 25kA Neutral solidly earthed 2.5kV 6kV For 1000kVA please consult us For other requirements than the above table, please consult us 7

MATELEC s.a.l Made in Lebanon C A a b c B a Manufactured by Matelec s.a.l E ma il : ma te le c@ ma te le cg ro up.com P.O.Box : 12 Jbeil - Lebanon Tel: +961 9 620 920 Fax: +961 9 620 934/35 A1 A2 B1 B2 C1 C2 b c Sectionalizing Switch Fuse MagneX n Fig 14 Line Sectionalizing switch and earth controls Fig 15 Led ( voltage indicator) Fig 16 Elbow Connector Fig 17 Grounding terminals 2.5. Dimensions and Weights L1 L2 E A B F C D H G Rating kva 250 400 630 -Bmm 850 850 850 -Amm 1230 1230 1230 -Hmm 813 813 813 -Cmm 2080 2080 2080 -Dmm 1230 1230 1230 -Emm 1975 1975 1975 -Fmm 715 715 715 -Gmm 1117 1117 1117 Total Weight Kg 2550 2900 3250 Dimensions and weights are approximate and may change according to specifications. 8

Fig 18 Medium voltage cable support + clamps Fig 19 Insulated device for drive (Hotstick) Fig 20 Medium voltage compartment Fig 21 Low voltage compartment 1 2 3 4 5 6 7 8 9 10 26 11 12 13 MATELEC Ma de s.a. Le ba in non l AB A2 C abc A1 B1 Te Fa Em Manufa P. O. l:+96 x:+96 ail:mat Bo B2C1 x ct 1 : ur ed 20 be @m 0 y 934/3 Matel - Le banon 5 ec gr ou.a.l 12 p. C2 com s9 920 b6 62 J Ma Fu se gnex Se ct itch ion al izingsw ab nc 14 L1 L2 15 16 17 22 18 19 20 18 23 24 25 21 1. Lifting Lugs (Fig 5) 14. Line Sectionalizing switch and earth controls (Fig 14) 2. Dielectric refill plug 15. Led ( voltage indicator) (Fig 15) 3. Name Plate + single line diagram (Fig 6) 16. Medium voltage screened bushings (Fig 11) 4. Mimic and labels (Fig 7) 17. Elbow Connector (Fig 16) 5. Three phase main interrupter (Fig 8) 18. Grounding terminals (Fig 17) 6. Off load tap changer (Fig 9) 19. Medium voltage cable support + clamps (Fig 18) 7. LV porcelain bushings (Fig 10) 20. Medium voltage compartment (Fig 20) 8. Power meter (Optional) 21. Rollers 9. Current Transformers 22. Fuses 10. Power Meter Protection Fuses (optional) 23. Low voltage compartment (Fig 21) 11. Pressure relief valve (Fig 12) 24. Low voltage cable support + clamps 12. Dielectric level indicator (Fig 13) 25. Drainage and sampling device 13. Blocking device 26. Insulated device for drive (Hotstick) (Fig 19) 9

ELECTRICAL EQUIPMENT INDUSTRIES COMPANY LTD. P.O.Box 850175 Amman 11185 Amman, Jordan Tel: (962) 6 5727861/2 Fax: (962) 6 5727863 E-mail: electric@wanadoo.jo INTERNATIONAL TRANSFORMERS MATELEC LTD. 10th of Ramadan City, Egypt Tel: (20) 2 4149004-2901795 Fax: (20) 2 4155614 E-mail: itm.office@link.net MATELEC S.A.L. Amchit - Ghorfine P.O.Box 12 Jbeil - Lebanon Tel: (961) 9 620920 Fax: (961) 9 620934/5 E-mail: matelec@matelecgroup.com SAUDI MATELEC CO. FOR INDUSTRIES LTD. Dabab Street, Dabab Bldg, 3rd floor, Office Nº 10 P.O.Box 52114, Riyadh 11563 Riyadh, Kingdom of Saudi Arabia Tel: (966) 1 4029909 Fax: (966) 1 4024280 E-mail: agos@saudimatelec.com.sa TRANSFO MATELEC S.A. ZI de Briangaud 35600 Redon, France Tel: (33) 2 99711650 Fax: (33) 2 99721700 E-mail: info@transfo-matelec.fr

MATELEC GROUP Amchit - Ghorfine - P.O.Box: 12 Jbeil - Lebanon Tel: (961) 9 620 920 - Fax: (961) 9 620 934/5 E-mail: matelec@matelecgroup.com www.matelecgroup.com