Table of Contents Next FLO-SAFE Manifold System Pre-Installation Kit Matrx Toll-Free: Technical Support: Fax: Rev.

Similar documents
O2/N2O Manifold System Instruction Manual

Lifeline Medical Systems

At Amico Labs we are dedicated to continued growth while producing products of outstanding quality, and providing excellent service.

Mounted Instrument Head

ClassicSeries Compressor Installation

Asepsis 21 Delivery Unit

Lifeline Medical Systems

Automatic Changeover Medical Manifold Installation, Operation and Maintenance Manual

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

Instruction Sheet. Subject: Installations Instructions. Air Compressor Kits. Importan

Radius Cuspidor (for Cascade 1040 or Decade 1011/1021 Chairs)

WARNING NORDIC ALUMINIUM LIGHTING TRACK SYSTEMS

INSTALLATION INSTRUCTIONS 88029

Installation Instructions

PowerAir Compressor Installation

ANZI Transfer Switch and Generator Wiring Installation Addendum

INSTALLATION INSTRUCTION 88088

Go Digital! Advanced Conscious Sedation Systems. 2 New Products! New! New! Digital Precision and Safety. Clearing Your Work Space.

Base Power Infeed Installation for Training Tables with Modular Table Power System

INSTALLATION INSTRUCTIONS 88511

INSTALLATION INSTRUCTIONS 88518

Installation Instructions for Lighthouse SS Power Pedestal Rev. 3 5/20/14

LED Exam Light. Service and Parts Manual. Model Numbers: FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY Rev. (1/23/18)

SECTION COMPRESSED-AIR PIPING FOR LABORATORY FACILITIES

INSTALLATION INSTRUCTIONS

Suspension System RS6582B

FULL HEIGHT ALUMINUM TURNSTILE DOUBLE UNIT AT-FAL SERIES I N STALLATION AND O P E RATING I N STRUCTIONS

RAYMOND EMC ENCLOSURES QUIETSHIELD OPERATION AND MAINTENANCE MANUAL

5300 Series Installation Guidelines

INSTALLATION INSTRUCTION 88094

Temperature Sensor Series

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series

Suspension System RS6525 (B)

ACSI MODEL POWER SUPPLY INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE. For Carrier/Bryant Residential Power Systems

EPLX and D2LX lighting panelboards Installation & maintenance information IF 1813 APPLICATION D2LX/EPLX IF SHEET TABLE OF CONTENTS WEIGHTS

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control

Installation Kitchen Faucet Filtration System Instructions GXK285JBL

Reference Manual FM-200 Series

INSTALLATION INSTRUCTION 88578

INSTALLATION INSTRUCTIONS

HP x HP. Lifeline Medical Systems High Pressure Fully-Automatic Manifold Basic/TAE NFPA/ISO. Installation, Operation and Maintenance Instructions

INSTALLATION MANUAL 2000WCY

Models- 8105, Commercial Vacuums. Product Information Product Dimensions. Important Safety Instructions

INSTALLATION INSTRUCTION W Track Recessed 120V Flangeless

NOTE: The orientation of the mounting brackets are critical. (See Figure 4)

RU SERIES UPGRADE TempAssure Compatible

Jeep Wrangler (JK)

Go Digital! Advanced Conscious Sedation Systems. Digital Precision and Safety. Clearing Your Work Space. Technology for the Future.

Installing Your 220v J-POD Kit

INSTALLATION INSTRUCTIONS FOR DSP9600/9100 WHEEL BALANCER

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

EGOLD-1000 Electronic Grease Level Detector

INSTALLATION AND OPERATING INSTRUCTIONS

MASTERsine Inverter PXA Series Installation Guide

FLUSH MANIFOLD REFERENCE MANUAL FOR LIQUID LAUNDRY SUPPLY SYSTEMS. FM-500 Series. P/N Rev. C

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

AC Level 2 Wall Mount Charging System. Installation Manual. WE-30 Series. Simply Smart.

Installation Instructions: Side Delivery Units BDS-2555

Parts and Instruction Manual Frontrunner Series Floor Machines Low Speed & Dual Speed

OPTEVA 378 ENHANCED CASH RECYCLER TERMINAL FRONT LOAD LOBBY UNIT PLAN VIEW FRONT VIEW SIDE VIEW

DEMA 951 FLUSH MANIFOLD WITH 24V DC VALVE INSTALLATION INSTRUCTIONS

Suspension System RS6507B (Rubicon models require end link kit RS6753B for a complete installation)

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS

POOL BARON Nicheless Color Changing LED Pool Light

AFT MOUNTED OXYGEN SYSTEM INSTALLATION BEECHCRAFT 33, 35, 36, 55, AND 58

Installation Instructions

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER

Lifting height 5.5" - 72" with adapters " Height overall 165" Width between columns 122" Drive through 109" Width overall 151.

INSTALLATION INSTRUCTIONS

INSTRUCTIONS. EZ-EFI FK In-Tank Fuel Kit

Installation. Part A, Section 3. This section covers the following unit configurations: 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G)

For Use with Model(s):all electric models

LED PURGE VALVE KITS P/N 16028NOS (5 lb. bottle) & 16029NOS (10 lb. bottle) Instruction Sheet P/N 199R10412

INSTALLATION INSTRUCTION Rev A

2015+ dodge charger dedicated fuel system

LED Light Bar. Series LLB. Installation Instructions

AUTO REWIND AIR HOSE REEL

INSTALLATION INSTRUCTIONS STUDIO S

Woda-Sci System Installation Parts Set

INSTALLATION INSTRUCTIONS

Suspension System RS66102B

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM

Assembly Instructions for the Portable Fluid Power Demonstrator (PFPD) (Kit Version: Excavator Arm Trainer)

Installation and Service Manual

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G)

The LED Driver Expert

Crescent Flush Manifold FOR LIQUID LAUNDRY SUPPLY SYSTEMS

A-dec 200 P RE-INSTALLATION GUIDE

SNIPER NITROUS SYSTEMS

Compose GYPSUM Mud-In

Water Valve Shutoff. WVS Water Valve Shutoff

Veterinary Scavenger Interface

Fluid Coil Installation, Operation and Maintenance

P239-1 Supply Pumper Instructions

3 Phase Smart Controller

3143 Production Drive Fairfeild, Ohio Model HA Installation and Service Manual

INSTALLATION INSTRUCTIONS

Transcription:

FLO-SAFE Manifold System Pre-Installation Kit Instruction Manual Matrx 145 Mid County Drive Orchard Park, New York 14127 716-662-6650 Toll-Free: 800-847-1000 Technical Support: 888-279-1260 Fax: 716-662-8440 E-mail: matrx@matrxmedical.com 10379100 Rev. D

Table of Contents Section 1.0 Manifold Plate Mounting...1-2 1.1 Kit Contents 1.2 Installation of Manifold Mounting Plate 1.2.1 Drywall Mounting 1.2.2 Wall Stud Mounting 1.2.3 Crossmember Mounting Section 2.0 Piping System...3 2.1 Piping System Installation 2.1.1 Piping Materials and Brazing Methods 2.1.2 Testing the Piping System 2.1.3 Purging the Piping System Section 3.0 Electrical Connections...4 3.1 Supply Circuit Connection 3.2 Low Voltage Signal Cable Safety Warnings and Important Information IMPORTANT: Installation must be performed by qualified technicians in accordance with local codes. WARNING: To prevent any possibility of cross-connection of oxygen and nitrous oxide, FLO-SAFE components use a diameter indexing system. All oxygen tubing must be 1/2 O.D. and nitrous oxide tubing 3/8 O.D. Modifying this piping convention exposes the installer to liability and presents a hazard to the doctor and his patients. CAUTION: If the optional Zone Valve is installed, protect the valve body from heat damage by wrapping the connecting tails with wet rags during brazing.

SECTION 1.0 MANIFOLD PLATE MOUNTING 1.1 Kit Contents The FLO-SAFE Manifold System Pre-installation Kit consists of these four items: Manifold mounting plate assembly with copper tubing pigtails Four-conductor alarm signal cable -100' Hardware package containing: #10 x 3/4" wood screws - 4 Hollow wall anchors - 4 Wire nuts - 2 #6-32 nuts with lock washers - 2 Romex connector - 1 Lug connector - 1 #10-32 x 2" socket head screws - 2 (For manifold installation, leave finger-tight in manifold mounting plate threaded sockets.) 1.2 Installation of Manifold Mounting Plate See Figure 1 to select a location for the manifold mounting plate. The location selected must be within 36 inches of the proposed location for the gas cylinders because 36-inch lines are provided to connect the FLO-SAFE Manifold to the cylinders. Mount the bottom edge of mounting plate 5 feet above the floor. IEC CORD CAP NOTE: UP label indicates proper orientation. 1.2.1 Drywall Mounting 1. Use the mounting plate as a template. Mark locations of the four spacers on back of plate and the four corner holes. 2. Drill 1" diameter clearance holes through drywall at each spacer location so mounting plate fits flush to wall. 3. Drill 1/4" holes at corner holes. Insert hollow wall anchors in corner holes. Attach plate using anchors. 1.2.2 Wall Stud Mounting 1. Use mounting plate as a template. Mark the upper and lower rear spacer holes. 2. Attach mounting plate to stud using wood screws. 1.2.3 Crossmember Mounting 1. Use mounting plate as a template. Mark the left, right and lower rear spacer holes. 2. Attach mounting plate using wood screws. Figure 1. Installation Options for Manifold Mounting Plate and Main Power Installation 1

MANIFOLD PLATE MOUNTING FLOW TRIPLE GANG ELECTRICAL BOX FOR ALTERNATE PRE-DRYWALL INSTALLATION (NOT PROVIDED) CONNECT WITH WIRE CONNECTORS (SUPPLIED WITH ALARM PANEL) * FOR OPTIONAL 90dB ALARM TWO ZONE VALVE SHUTOFF SIGNAL CABLES - 4 CONDUCTORS EACH ALARM PLATE AND HARDWARE SUPPLIED SEPARATELY WITH ALARM PANEL ASSEMBLY LOCATE WALL PLATE FOR OPTIONAL DESK MOUNT KIT WITHIN 6 FT OF INTENDED DESK. SELECT HIGH TRAFFIC AREA. Figure 2. Manifold Plate Pre-Installation 2

SECTION 2.0 PIPING SYSTEM 2.1 Piping System Installation Install O2 and N2O copper tubing (shown in Figure 2) as follows: 1. Leave 1/2 of lateral flexibility in piping at mounting plate pigtails to allow for installation of the FLO-SAFE manifold. 2. If the optional Zone Valve is installed, wrap wet rags around piping to prevent heat damage to the valve body. See Figure 3. 2.1.1 Piping Materials and Brazing Methods 1. Piping is to be annealed (soft temper) ASTM B88 Type K or L copper tubing, cleaned for oxygen service and capped prior to installation. 2. Joints are to be brazed without the use of flux. 3. To prevent cross-connection of oxygen and nitrous oxide: All oxygen tubing to be 1/2 O.D. All nitrous oxide tubing to be 3/8 O.D. All vacuum tubing to be 5/8 O.D. 4. While brazing, purge piping system with low flow, oil-free, dry nitrogen to prevent formation of copper oxide in the line. WRAP WET RAGS AROUND PIPING AT EACH END WHEN BRAZING 2.1.2 Testing the Piping System After brazing all joints, test piping: 1. Pressurize piping system to 150 psig with oilfree dry nitrogen and leak test all joints. 2. Allow piping system to remain pressurized to 150 psig for 24 hours with source shutoff valve closed. Maximum allowable pressure loss is 5 psi. 2.1.3 Purging the Piping System After successful completion of pressure testing, purge the piping system: 1. Blow piping system clear with oil-free dry nitrogen. 2. Purge piping system with intermittent high flow oil-free dry nitrogen to remove any particulate matter. Flow each outlet fully until purging process produces no discoloration in a white cloth. 3. Cap piping system. No further brazing shall be performed. 4. If further brazing is required, leak test and purge must be repeated. TO OUTLET STATIONS ZONE VALVE SHUTOFF BOX IN PATIENT AREA Figure 3. Brazing Copper Tubing at Zone Valve 3

SECTION 3.0 ELECTRICAL CONNECTIONS 3.1 Supply Circuit Connection All electrical connections must be made to local codes by a licenced electrician. A dedicated 15A, 115VAC, 14 gauge supply circuit is required. This must be a dedicated circuit due to the emergency system requirements, rather than the amperage demands, of the FLO-Safe system. To install the supply line: 1. Feed dedicated branch circuit line to Manifold Mounting Plate electrical box. For surface-mounted power line, use knockout on top of box. For in-wall power line, use rear center knockout. Note: Do not use side knockouts on electrical box. 2. Attach bushing of supplied Romex connector to incoming cable. Insert connector through chosen knockout and secure with connector locknut. 3. Connect supply hot line to black or brown wire using wire connector provided. 4. Connect Supply neutral line to white or blue wire using wire connector provided. 5. Connect supply ground to ground post inside electrical box. Attach ground of Manifold power cord to same post using #6-32 nut provided. 6. Attach cover to box. 7. To facilitate future servicing, label dedicated Manifold System supply circuit at service panel. 3.2 Low Voltage Signal Cable Feed low voltage four-conductor alarm signal cable (provided) through plastic bushing at upper right corner of Manifold Mounting Plate. Run opposite end to Alarm Panel Mounting Plate (supplied with Alarm Panel). Figure 4. Supply Power Connection to Manifold 4

FM 40049 ISO-9001 Certified Manufacturer 145 Mid County Drive Orchard Park, New York 14127 716-662-6650 Toll-Free: 800-847-1000 Technical Support: 888-279-1260 Fax: 716-662-8440 E-mail: matrx@matrxmedical.com 10379100 Rev. D