MPP 910 IDS MPP 930 IDS

Similar documents
SensoLyt 700 SensoLyt 700 SW

Operating manual. LabStation LS Flex/430

Operating manual. ba55321de LRD Conductivity measuring cell to be installed in pipelines. ba55321de01 12/00

Water analysis, QC and more:

JUMO BlackLine Lf-GT / -EC electrolytic 2-electrode conductivity cells

JUMO heattherm Type a Protection temperature limiter, as a panel-mounting thermostat a Compensated for ambient temperature

OPERATIONS MANUAL CR Thermoreactor

PHscan10S Pocket ph Tester Instruction Manual

Operating Instruction for Electronic Pressure Switch. Model: PDD

JUMO heattherm-at and JUMO heattherm-dr

Conductivity Measurement CLM 280

Explosion-protected surface-mounting Thermostat ATH-Ex Series

Agilent InfinityLab Quick Change Valve G4237A

PH60 Series Premium ph Testers

ADA-WA 1 ADA-WA 4. Installation instructions. Sensor adapter for installation in the retractable armatures WA700/2 and WA 700/10

JUMO heattherm Type Protection temperature limiter, as a panel-mounting thermostat Compensated for ambient temperature

Marin Control Digital

Agilent G4239C Valve Kit - Instructions

PHscan30S Pocket ph Meter Instruction Manual

Electric Immersion Pumps PXA and PXK, sealless

HD18F2M1.

testo 206 ph/ Temperature Measuring Instrument Bedienungsanleitung Instruction Manual

Surface-mounting Thermostats Series ATH-SW

Immersion fittings. Brief description. Installation options Standard. Series Page 1/7. Data Sheet

Mounting Bracket AZURA L Supplement HPLC. Document No. V6806

T-Rack 3.0. Integrated rack solutions for ultrafiltration

COM-100 EC / TDS / TEMPERATURE METER

Thermostats for panel mounting Series ETH

measuring vessel air inlet conductivity cell reaction vessel sample absorption solution (water) heating block (e.g. 120 C)

Panel-mounted Thermostats

better measurement Simply a question of

Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES

PSR Centrifugal pumps

JUMO tecline Ci-S. Inductive conductivity and temperature sensor for general process engineering. Installation Instructions T94Z001K000

Bruker BioSpin MATCH. Multiple Adjustable Tube Clamp Holder User Manual - Version 005. NMR Solutions. think forward

T-Rack 3.0. Boost your performance with 80 m²

PC60 Premium Multi-Parameter Tester (ph/ec/tds/salinity/temp.) Instruction Manual. APERA INSTRUMENTS, LLC V6.4

ORPscan20 Pocket ORP Tester Instruction Manual

Compensation unit AGE-XY 50-80

better measurement Simply a question of

Operating Instructions Flexdip CYA112

RTD Temperature Sensor omnigrad T -TR 470

User manual. AGRETO Soil Compaction Tester AGRETO electronics GmbH

Bante220 Portable ph Meter Instruction Manual

Operation Manual MODEL EC331. Microcomputer Based Conductivity /Resistivity & Temperature Pocket Meter EC331

T-Rack 3.0 S. Modern ultrafiltration in a compact design

SERVICE MANUAL. STARTER Portable Meter ST300 ST300C ST300D ST400D. Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ (973)

Pressure Transmitter. Informational & Installation Manual

Level Probes multicap T DC 12 TA multicap T DC 11/16/21/26 TAN/TAS

Agilent 1200 Series Manual Injector

Care and use guide. Contents. page

Centrifugal pumps. Main catalogue.

Instruction Manual AVTM for. Strip Chart Recorder Catalog Nos and

Cable Glands & Accessories

PH20 Value ph Tester Instruction Manual

8,1,8,1,2,7,2,7,6,3,6,3,4,5,4,5

Product card User manual. KP Strong Safe

Product card User manual. Koliber Safes Koliber Deposit Drop Safes KSN Wall Safes Grade S1

Montage- und Bedienungsanleitung Installation and Operating Instructions

7774 Series Stainless Steel Insertion/Removal Assembly for Use with Meredian Electrodes

User Manual Pocket Pro, Pro + ph

Operating Manual for sprayvalve MKDD-IS

Salt 1 Pocket Salinity Tester Instruction Manual

CONTACT WATERRA. WS-2 REELCASE WATER LEVEL TAPE

StepWave ion guide: cleaning instructions addendum

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

HI Ethylene Glycol Refractometer INSTRUCTION MANUAL

Supplement to operating instructions Pressure Probe OTT PLS

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet.

Product card User manual. KP Strong Safe

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type

Measuring Cells for free chlorine, chlorine dioxide, ozone

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Foss Electric Milko-Scope II Meter Manual

mass flowmeter for compressed air

Measuring capsule heat meter G54 / G55

Operating Manual for extrusion valve MMKD-40 KV/LV/LVP

Material Handling Products for Industrial and Process Applications

ABB MEASUREMENT & ANALYTICS DATA SHEET. AC200 Series Industrial 2-electrode conductivity cells with rapid temperature response

Toothed belt axis ELGC-TB-KF. Operating instruction [ ]

CONDUFIX Cable protection system. Protective conduits Connection fittings Connection manifold 90 -flange System holder Cable assemblies

BOHLENDER GmbH Phone: +49(0)9346 / Fax: +49(0)9346 / Internet:

WalkLAB Digital Dissolved Oxygen meter HD9030

Electric Plug-and-Socket Connectors

Cover Plate Closures. Gaskets for Self-Sealing Cover Plate Closures. Graphite Cover Plate Gaskets. Double-Cone Gaskets.

OPERATIONS MANUAL CR Thermoreactor

S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en

JUMO tecline CR-4P Conductive 4-Electrode Conductivity Sensor

SEBA HYDROMETRIE, User Manual KLL

Signet Conductivity/Resistivity Electrodes

INSTRUCTION MANUAL. Handy Polaris

CPM280. Technical Information. ph/orp measurement Battery-driven pocket meter for ph and ORP measurement

Agilent G5632 Valve Kit Instructions

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

Polymer Electric. Product information. DIY Sensor Profiles

Betriebsanleitung / Operating Manual / Mode d emploi / Manual de operación ProMinent Dosiertechnik GmbH Heidelberg Germany

Signet Conductivity/Resistivity Electrodes

Agilent InfinityLab Quick Change Valve G4235A Instructions

Modular Laparoscopic Instruments Flexible and safe

Online data sheet. i15-em0123 Lock i15 Lock SAFETY LOCKING DEVICES

Transcription:

Operating manual MPP 910 IDS MPP 930 IDS MPP 910 IDS MPP 930 IDS (Sample figures. Actual equipment depending on scope of delivery and selected options) Modular multi-parameter probe with depth measurement ba75981e01 10/2012

MPP 9x0 IDS Copyright Weilheim 2012, WTW GmbH Reprinting - even as excerpts - is only allowed with the explicit written authorization of WTW GmbH, Weilheim. Printed in Germany. 2 ba75981e01 10/2012

MPP 9x0 IDS Contents MPP 9x0 IDS - Contents 1 Overview.......................................... 4 2 Operation......................................... 7 2.1 Opening and closing the plug connections................. 7 2.2 Commissioning...................................... 8 2.3 Mounting the holding shackle........................... 9 3 Cleaning......................................... 10 4 Technical data.................................... 11 4.1 Dimensions, weights................................. 11 4.1.1 MPP 910..................................... 11 4.1.2 MPP 930..................................... 12 4.1.3 Accessories................................... 12 4.2 Application characteristics............................ 13 4.3 General data....................................... 13 4.4 Measurement characteristics.......................... 14 5 Wear parts and accessories......................... 15 ba75981e01 10/2012 3

Overview MPP 9x0 IDS 1 Overview The MPP 9x0 IDS multi-parameter probe is a modular system, consisting of a basic module and various expansion options. System components (figure see page on the right) 1 Basic module MPP 910 IDS with one sensor plug-in position 2 Basic module MPP 930 IDS with three sensor plug-in positions 3 AS/IDS-xx connection cable between basic module and meter or sensor and meter (xx = different lengths available) 4 Blind plug BPO/IDS 900 for cable plug-in position Expansion options: 5 Digital sensors of the XXX-P series, e.g. FDO 925-P 6 BPI/IDS 900 blind plug for BPI/IDS 900 sensor plug-in position 7 Long protective tube, to protect the sensors connected 8 Short protective tube, for usage of the basic module without any sensors. Reduces the distance between the depth/temperature sensor and the bed of the water body 9 Sinker 10 Holding shackle (accessory) to be screwed on instead of the protective ring (pos. 11) 11 Protective ring Depth measurement Depth/temperature sensor On the shaft of the basic module there is a pressure sensor with integrated temperature measurement. Based on the pressure and temperature value the meter calculates the depth of immersion in the measuring medium. The temperature measurement is used for the temperature compensation of the pressure sensor and for density compensation. 4 ba75981e01 10/2012

MPP 9x0 IDS Overview MPP 910 IDS MPP 930 IDS 11 11 1 2 10 10 4 3 6 5 8 7 7 8 9 9 ba75981e01 10/2012 5

Overview MPP 9x0 IDS IDS plug connection Recommended fields of application All plug connections of the basic module, sensors, connection cable and blind plug are of the same type. A lock protects the connections against being inadvertently disconnected. With the connection cable, the individual sensors can also be directly connected to the meter if necessary (for calibration or firmware update). On-site measurements in rivers, lakes, sea water and brackish water, wells, leachate that is not or only slightly polluted Measurements in boreholes Depth profile measurements Measurements in ground and spring water 6 ba75981e01 10/2012

MPP 9x0 IDS Operation 2 Operation 2.1 Opening and closing the plug connections The following instructions apply to all actions where any components are connected or disconnected (e.g. exchange of blind plug sensor): Plug connection closed and locked 4 1 3 Guidance 2 Groove Opening the plug connection Closing the plug connection If necessary, clean the plug connection Open the locking device (step 1) Use your thumb and index finger to press the clips of the connector together, and pull the connector out of the plug (step 2). Make sure that the plug connection is completely dry and clean. Align the guidance of the connector with the groove in the plug and insert the connector in the unlocked plug until it catches (step 3). Close the locking device (step 4). ba75981e01 10/2012 7

Operation MPP 9x0 IDS NOTE All plug-in positions have to be equipped with sensors or closed with blind plugs before the multi-parameter probe is immersed in the measuring medium. 2.2 Commissioning Prepare the sensors for the measuring operation (see sensor operating manual). For calibration, connect the sensors to the meter with the 1.5 m connection cable. Calibrating the sensors while they are installed is not possible. The depth and temperature measurement of the basic module is calibration free (factory calibration). Equip the basic module with the required sensors: Unscrew the short protective pipe Per plug-in position: Replace the blind plug with a sensor (depending on the required design, how to do this is described on page 7). Screw on the long protective pipe Screw the sinker on the open end of the protective pipe so the probe will go down faster. Connect the basic module to the meter. NOTE The connection cable without any problems withstands the tractive forces that occur when it is pulled by hand in a water body where there are no strong current and no obstacles. If the current is strong or if there are obstacles the tractive forces can temporarily be much higher and cause the cable to snap. If you are in doubt we recommend to attach the multi-parameter probe with the holding shackle (accessories) to a sufficiently strong rope or a chain so the probe will not be lost. NOTE All plug-in positions have to be equipped with sensors or closed with blind plugs before the multi-parameter probe is immersed in the measuring medium. 8 ba75981e01 10/2012

MPP 9x0 IDS Operation 2.3 Mounting the holding shackle The holding shackle is screwed onto the sensor instead of the protective ring. To do so, proceed as follows (sample figure of MPP 930 IDS): 2 1 Disconnect the connection cable from the basic module (see page 7) Unscrew the protective ring (pos. 1). Thread the connection cable through the connecting piece of the holding shackle (pos. 2) and reconnect it to the basic module Screw the holding shackle to the basic module ba75981e01 10/2012 9

Cleaning MPP 9x0 IDS 3 Cleaning Please observe the instructions on cleaning the sensors given in the respective sensor operating manuals. If necessary, remove the sensor for cleaning and close its plug-in position with a blind plug. Exterior cleaning Remove water-soluble contamination by rinsing with deionized water. Other types of contamination have to be removed as follows while the contact time with the detergents should be kept as short as possible: Contamination Cleaning procedure Fat and oil Rinse with water containing household washing-up liquid Lime and hydroxide deposits Rinse with citric acid (10 % by weight) Cleaning the pressure sensor Thoroughly rinse the multi-parameter probe with water after this. To clean the pressure sensor, remove the screen lid with your fingernails. Then rinse the recess with a mild water jet (e.g. wash bottle or slightlyrunning faucet). NOTE The membrane of the depth sensor is very sensitive to mechanical impacts. Therefore, avoid any touching of the membrane. Do not point a sharp water jet at the membrane while cleaning it. 10 ba75981e01 10/2012

MPP 9x0 IDS Technical data 4 Technical data 4.1 Dimensions, weights 4.1.1 MPP 910 Dimensions (in mm) 503 443 347 297 40 40 Protective pipe long Protective pipe short Weights Basic module without cable, sinker and sensors (all plug connections closed with blind plugs) Sinker Holder EH/40-SW With short protective pipe approx. 274 g With long protective pipe approx. 355 g Approx. 497 g 64 g ba75981e01 10/2012 11

Technical data MPP 9x0 IDS 4.1.2 MPP 930 Dimensions (in mm) 500 400 69,5 Protective pipe long 347 297 69,5 Protective pipe short Weights Basic module without cable, sinker and sensors (all plug connections closed with blind plugs) Sinker Holder EH/70-SW With short protective pipe approx. 929 g With long protective pipe approx. 1131 g Approx. 1870 g 105 g 4.1.3 Accessories Weights BPI/IDS 900 17 g BPO/IDS 900 12 g 12 ba75981e01 10/2012

MPP 9x0 IDS Technical data 4.2 Application characteristics The application range of a multi-parameter probe can be limited due to the sensors installed (see sensor operating manuals). The following specifications refer to the probe without any sensors installed. Measuring medium Pressure resistance Allowed -5... 50 C (23... 122 F) temperature range Allowed ph range 4... 12 IP 68 (1 x 10 6 Pa or 10 bar) The MPP 9x0 IDS multi-parameter probe meets the requirements according to article 3(3) of the directive, 97/23/EC ("pressure equipment directive"). Storage conditions Storage temperature -25... 50 C (-13... 122 F) 4.3 General data Materials Enclosure of the basic module, protective pipe, blind plug POM Sinker Stainless steel 1.4571 Depth temperature sensor including pressure membrane Hastelloy C-276 Holding shackle (option) Titan Grade 3 IDS plug connection Connection type Materials of plug and connector 4-pole, watertight plug connection with lock, reverse polarity protected Synthetic materials: Glass fiber reinforced Noryl, TPU, TPC-ET, POM, PEEK, PBT O-ring: FPM Contacts gold-plated ba75981e01 10/2012 13

Technical data MPP 9x0 IDS Connection cable Diameter 4.3 mm Smallest allowed bend radius Material of cable sheath Permanent bend: 63 mm Single time or short time bend:21 mm TPE-U, aramid fiber reinforced 4.4 Measurement characteristics Depth measurement Measuring principle Measuring ranges at 20 C (68 F) Resolution Accuracy at 20 C (68 F) Automatic density compensation Piezo-resistive pressure sensor, calibrationfree 0.50... 100.00 m (328 ft) 0.05 m (0.16 ft) 0.25 m (0.82 ft) ± 1 digit Indirectly through the integrated temperature measurement. Calculated by the measuring instrument on the basis of the temperature/ density function of water. Additional compensation of the salinity after the salinity value was entered on the meter. Temperature measurement Temperature sensor Measuring range Resolution Semiconductor sensor integrated in the pressure sensor -5... 50 C (23... 122 F) 0.1 K 14 ba75981e01 10/2012

MPP 9x0 IDS Wear parts and accessories 5 Wear parts and accessories Connection cablempp 9x0 IDS - meter Description Model Order no. IDS connection cable, 1.5 m AS/IDS-1.5 903 850 IDS connection cable, 3 m AS/IDS-3 903 851 IDS connection cable, 6 m AS/IDS-6 903 852 IDS connection cable, 10 m AS/IDS-10 903 853 IDS connection cable, 15 m AS/IDS-15 903 854 IDS connection cable, 20 m AS/IDS-20 903 855 IDS connection cable, 25 m AS/IDS-25 903 856 IDS connection cable, 40 m AS/IDS-40 903 857 IDS connection cable, 60 m AS/IDS-60 903 858 IDS connection cable, 100 m AS/IDS-100 903 859 Blind plug Description Model Order no. Blind plug for IDS sensor plug-in position BPI/IDS 900 908 370 Blind plug for IDS cable plug-in position BPO/IDS 900 908 371 General accessories Description Model Order no. Holding shackle for MPP 910 IDS EH/40 SW 109 315 Holding shackle for MPP 930 IDS EH/70 SW 109 316 Note For further accessories, refer to the WTW catalog or the Internet. ba75981e01 10/2012 15

Wissenschaftlich-Technische Werkstätten GmbH Dr.-Karl-Slevogt-Straße 1 D-82362 Weilheim Germany Tel: +49 (0) 881 183-0 +49 (0) 881 183-100 Fax: +49 (0) 881 183-420 E-Mail: Info@WTW.com Internet: http://www.wtw.com