Small Motorized Actuator

Similar documents
Surepowr Series 100 Installation Manual

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

Installation Instructions

Surepowr Series Sure 150

I-BFV.KIT Butterfly Valve Gear Operator Replacement

SUREPOWR TM SERIES -SURE 49 FIELD INSTALLATION INSTRUCTIONS

SUREPOWR TM SERIES -SURE 24/25 FIELD INSTALLATION INSTRUCTIONS

IMO-517 (7027) ISSUE 3/97 ERA12, 25, 50, 83, 125, 167, 208 AND 250 ELECTRIC ACTUATORS INSTALLATION, MAINTENANCE AND OPERATING INSTRUCTIONS

HQ-006 ¼ Turn Actuator

AE Installation Operation & Maintenance Instructions

MODULATING SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

Installation and Operating Manual

Thermal Shut-Off I. OVERVIEW OF THERMAL SHUT-OFF VALVES

OIL FIELD ELECTRIC ACTUATOR INSTRUCTION MANUAL SPECIAL APPLICATIONS ACTUATORS Q 6.0.1

ANDCO Eagle Actuator Instruction Manual

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

Milwaukee's Electric Actuator Installation, Operation & Maintenance Manual

DeZURIK TEN-POSITION LEVER MANUAL ACTUATOR

Electric Actuator Installation, Operation & Maintenance Manual

Radius, LLC Electric quarter turn actuator EW series Installation, Maintenance and Operating Manual

Your Global Flow Control Partner. Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

Recommended Installation Procedure (31 MARCH 2010) ATech Timing Belt Tensioner (979004) EA T 20 Valve Longitudinal Engine

Installation, Maintenance and Operation Manual

SERIES 73 ELECTRIC ACTUATOR OPERATION AND MAINTENANCE MANUAL. The High Performance Company

ELECTRIC ACTUATOR. Unic Series ROTARY TYPE Unic Z, 05 Unic 10 Unic 20, 40 Unic 60, 100, 150, 200 OPERATION MANUAL. Koei Industry Co., Ltd.

EW 350 ELECTRIC ACTUATOR INSTALLATION, MAINTENANCE AND OPERATION MANUAL

Sub Section Title Page No.

NOAH ACTUATOR NA-SERIES MANUAL EMICO EUNHA MACHINERY INDUSTRIAL CO.,LTD.

Valtek Auxiliary Handwheels and Limit Stops

Disassembly and Reassembly for WG Series Worm Gear Operator. User Instructions Part Number: XXXXXX, Rev. 0 Release: February 2017

ELECTRONIC CONTROL ACTUATOR

73000 Series Masoneilan* Sweep Angle Control Valves Models XX-73471

SERIES 90/91 R PNEUMATIC ACTUATOR OPERATION AND MAINTENANCE MANUAL. The High Performance Company

80 Series 4 Post Brake Instructions

Installation and Maintenance Instructions JSE2-0241MAEAD Extruder Clutch. World Leader in Modular Torque Limiters

Recommended Installation Procedure (11 DEC 09) ATech Timing Belt Tensioner (979847/901) VW 1.6/2.0L L4 EA189 CR Engine

ELECTRONIC CONTROL ACTUATOR

Fisher 2052 Diaphragm Rotary Actuator

DeZURIK MANUAL G-SERIES ACTUATOR USED ON PEF 100% PORT PLUG VALVES

Quarter Master Chief Series 92 Actuator

DeZURIK G-SERIES MANUAL ACTUATOR USED ON BOS BUTTERFLY VALVES

Recommended Installation Procedure ATech Timing Belt Tensioner and AUDI 2.0L 4V FSI & TFSI Engine (19 January 2015)

Model DFR 070/156/220 Rotary Actuator

VSI, LLC SERIES 2100 RESILIENT SEATED BUTTERFLY VALVES INSTALLATION, OPERATION AND MAINTENANCE MANUAL

DeZURIK DR 40B ROTARY DIAPHRAGM ACTUATOR

Installation and Maintenance Instructions JSE MAEAD Extruder Clutch. World Leader in Modular Torque Limiters

Quarter Master Series 94 Actuator

846T/847T. Teflon R. Lining Valve INSTRUCTION MANUAL TEFLON R LINING VALVE STANDARD SPECIFICATIONS EXPANDED VIEW

TIMING BELT AND SPROCKET(S) REMOVAL - TIMING BELT

Installation and Maintenance Instructions JSE1-0128MAEAD Extruder Clutch. World Leader in Modular Torque Limiters

Fisher 1051 and 1052 Style H and J Sizes 40, 60 and 70 Rotary Actuators

2001 SERIES CRYOGENIC BAR STOCK BODY VALVES

LCR Series REVERSING ELECTRIC ACTUATORS. Installation, Maintenance and Operating Instructions

EX Series. Electric Actuators for Ball and Butterfly Valves

DRAFT. Installation, Operation and Maintenance Instructions for Emerson KBG-V Series

Baumann Pneumatic Actuators

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

TRUNNION MOUNTED BALL VALVE INSTALLATION, MAINTENANCE, & REPAIR MANUAL

Operation & Instructions Manual SA 3 - SA 100 SAR 3 - SAR 100

HQ Series ¼ Turn Electric Actuator

SERIES 70 TUNNEL DAMPER MODEL ELECTRIC ACTUATOR OPERATION AND MAINTENANCE MANUAL

Cryogenic Wafer-Sphere Butterfly Valves

ECON ELECTRIC ACTUATOR Fig ELA60 Ex

Butterfly Valve Type 58 (PDCPD)

Maintenance Instructions. World Leader in Modular Torque Limiters. JSE AEA Extruder Clutch

Installation, Operating & Maintenance Instructions

Tech Note Truck 14 & 15.5 Twin Plate Cast Iron Type Installation Guidelines

DeZURIK M-SERIES MANUAL ACTUATOR

OPERATION INSTRUCTONS MODEL SG 05.1 SG Quarter-Turn Actuators

Fisher 1061 Pneumatic Piston Rotary Actuator with Style H & J Mounting Adaptations

EX Series. Electric Actuators for Ball and Butterfly Valves

Pneumatic Rotary Actuator Type 3278

LUF Series Unidirectional Electric Actuators

Recommended Installation Procedure Timing Belt Tensioner (979597) 2.0L DOHC, RENAULT F4R Turbo, F4R L DOHC, RENAULT F4P720 (05/18/2004)

- 1/7 - Copyright Litens Automotive Group All rights reserved.

DeZURIK R1 POWERRAC ACTUATOR ON 1/2-3" PEC ECCENTRIC VALVES

IOM FOR DYNATORQUE D-LOCK LOCKING DEVICE (DL TYPE)

DIRACT BRAKES 70 SERIES 4 POST BRAKE INSTRUCTIONS

1. Disconnect negative battery cable. 2. Remove upper and lower front timing belt covers..

OVERLOAD CLUTCHES FOR INDEX DRIVES

SERVICE MANUAL for. Engine-to-Generator. Part Number used on. John Deere Engine Driven Aircraft Ground Power Single-Bearing Generator Sets

Electric Actuator Installation, Operation & Maintenance Manual

Prepared. FUNCTION 3 Start up 3 Continuous operation 3 Shut down 3 Stand still 3

ATech Timing Belt Tensioner (979756) PSA EW10A 2.0L Engine

Bray/ VAAS Slurry Series Knife Gate Valve 760/762/765/766/767/768 Series Operation and Maintenance Manual

USER INSTRUCTIONS. Limitorque TM V Series. Installation Operation Maintenance. Experience In Motion FCD LMENIM AQ 02/15

User s Manual. Pneumatic Positioner. Series 58. J Flow. Series 58. J Flow

Fisher 657 Diaphragm Actuator Sizes and 87

20JA through 100JA 9020JA through 9070JA Balancer Series Service Manual

DeZURIK LA-SERIES MANUAL & ELECTRIC ACTUATORS

12 Series Linear Electric Actuator Installation, Operation & Maintenance Manual

Timing Belt Replacement

Butterfly Valve Type 57P

I & M Mark 708ME. Ideal Installation. Start-Up Procedure. Installation & Maintenance Instructions for Mark 708 & Motor Actuator

5. Keep rotating the water pump housing to release the belt tension and remove the belt once it becomes loose.

The POWER. In PRESENTATION PRODUCTS. Instruction Book for BOARDROOM ELECTROL DA-LITE SCREEN COMPANY, INC.

Installation, Operation and Maintenance Manual DOC.IOM.MO.E October MO-Series Manual Override Gearboxes

McCANNA Actuation Systems B

Transcription:

R Small Motorized Actuator INSTRUCTION MANUAL INDEX INTRODUCTION STANDARD SPECIFICATIONS EXTERNAL DIMENSIONS PRECAUTIONS DURING INSTALLATION ADJUSTMENT TRIAL OPERATION PRECAUTIONS BEFORE SERVICE MAINTENANCE TROUBLE SHOOTING Page 1 1 2 3 7 9 9 10 10

Introduction This is an instruction manual for the New ELMY actuator, one of the best selling models of butterfly valve actuators, which has been improved in a number of key areas. Operators of this actuator are expected to read through these instructions for the correct installation, operation, and maintenance. STANDARD SPECIFICATION Terminal board (Type 0 to 4)

EXTERNAL DIMENSIONS Dimensions / Weight Dimensions Mounting details Mounting flange details Tabel actuator selection

PRECAUTIONS DURING INSTALLATION Installation site (1) The ambient temperature of an installation site should be kept between 10 degrees C and 55 degrees C. (2) Any dangerous atmosphere should be kept out of the installation site. (3) Provide enough space for mounting/dismantling the cover of the electric cable terminals and allow reasonable access for future maintenance. Mounting (1) Before mounting, operate the valve by hand and make sure that it moves freely. Then shut the valve. (2) Pull and turn the handwheel of the New ELMY till the indicator points to the S position. Adeclutchable handwheel has been incorporated in the actuator for maximum safety and ease of operation. To disengage the clutch the handwheel is pulled out prior to turning. This allows the actuator to be turned manually and ensures safe operation in the event of the motor being energized. When released, the handwheel returns to the set position and the clutch is re-engaged.!

(3) Install the joint and spacer on the valve stem. New ELMY (4) Fasten the New ELMY to the baseplate with the four bolts. Spacer Joint Valve body (5) Turn the handwheel of the New ELMY and see that it moves freely without any interference due to misalignment of the valve. Cable connection All control circuits are printed on a circuit board. A simple change of the board can meet a variety of optional control requirements. It allows easy wiring connections. The replaceable board, together with the employment of the modified limit switch cam device, permits a quick change in specification. Seal packing Print base (1) Wiring connections should be in accordance with the diagram attached on the inside of the top casing cover. On completion, check the wiring connections carefully. (2) The two conduit Connections should be sealed in a proper manner against water. (3) Every cover on the casing is sealed with an O-ringstyle packing. Care should be taken not to cause any damage to the packing during disassembly or reassembly. "

Wiring diagrams (Standard) Type 00 M 1 2 3 4 5 6 7 Type 0 to 4 Standard With extra position limit switch (non-voltage) Purpose Limit switch contact development Wiring diagrams (Type 0 to 4) (Option) With intermediate limit switch Purpose Options Limit switch contact development

Wiring diagrams (Type 0 to 4) (Option) With potentiometer and extra position limit switch (non-voltage) Purpose Options Limit switch contact development With servo unit, potentiometer and extra position limit switch (non-voltage) Purpose M Options 1 2 3 4 5 6 7 8 9

ADJUSTMENT (1) The new limit switch cam mechanism has a unique device that permits easy on site adjustment at the top of the actuator. It also have a gear that allows a potentiometer to be added, if required. Valve open-end Loosen the securing nut. Valve shut-end (2) Before the adjustment of a position limit switch, release the lock nut on the locking bolt and then unwind the locking bolt with 4 to 5 turns. The limit switch is adjusted at our factory prior to shipment. Adjusting the limit switch (1) First, remove the top cover and pull out the indicator. Indicator Top cover (2) Slightly loosen the cap bolt of the limit switch striker with an Allen wrench. (3) Now, the limit switch strikers is ready to be moved in or out. Turn it with the screw driver clockwise to move it in, and counterclockwise to move it out. (4) Tighten the lock nut when the striker is in the required position. (5) Make sure that the limit switch operates at the correct position. 7

Adjustment of actuator (NEL with servo unit) (Type 0 to 4)

TRIAL OPERATION Manual operation (1) qpull the handwheel and w turn it in either direction, When released, it springs back. (2) Turn the handwheel clockwise to shut the valve. Turn the handwheel counterclockwise to open the valve. Caution: An excessive turn will result in a failure of the stopper or other components, Watch the position indicator and do not turn beyond the OPEN or SHUT position. Operation by motor (1) Before operation, make sure that the O and S on the position indicator match exactly the open / shut positions of the valve. (2) Ensure that the OPEN push button opens the valve, and the SHUT push button shuts it. (3) Ensure that the valve stops at its predetermined OPEN and SHUT positions. PRECAUTIONS BEFORE SERVICE Open Shut (1) Each New ELMY should be controlled by one circuit breaker or relay. If two or more New ELMY`s are controlled by one circuit breaker, they may sometimes actuate erroneously due to a loop circuit. (2) The New ELMY with a potentiometer should not be put into service for regulation of pressure, liquid level, and other operational parameters which usually require a continuous control. In such cases, our MICOM ELMY which has been developed for control purposes is the optimum actuator. (3) Signal circuits (for a potentiometer, input / output signals, etc.) should be strictly separated from power cables and high tension cables. 9

MAINTENANCE Lubrication (1) The New ELMY is lubricated with molybdenum bisulphate compound which has a long-life and anti-pressure characteristics. Therefore, no lubrication is required. Periodical operation (1) If the New ELMY is to be out of service for a long period, it should be operated periodically, say once a week, to keep it free. TROUBLE SHOOTING No start. Troubles Cause of trouble Solution No power. Put on the power. Cables disconnected. Replace the cables. Terminals out of place. Connect the terminals with the right mode. Low voltage or improper power source. Check the voltage with an instrument. The thermal protector has tripped. The phase advance capacitor failed. Cool down the ambient temp. Avoid too much repeated operation. Replace the capacitor. No signal light on. The lights not indicating. Replace the lights. Open Shut Limit switch failure. Replace limit switches. Misalignment of the stoppers. Realign the stoppers. 10

The specifications are subject to change without notice. Please consult us for the latest specifications. All copy rights reserved. Head Office 3-11-11 Shinmachi, Nishi-ku, Osaka 550-0013, Japan Telephon: 81-6-6110-2101/2102/2103 Telefax: 81-6-6110-2105/2106 E-mail:sales@tomoevalve.com Global Sales Operations Blk 8 Chia Ping Road #07-11 Singapore 619973 Telephone: 65-68995060 Telefax: 65-68995061 E-mail:sales@tomoe.com.sg Clearwater Road, Queensway Meadows Industrial Estate, Newport, South Wales NP19 4ST, United Kingdom Telephone: 44-1633-636800 Telefax: 44-1633-636801 E-mail:sales@tomoevalve.co.uk sales@tomoetritec.co.uk 600, Rockmead Drive Suite 115, Kingwood, Houston Texas, 77339, USA Telephon: 001-281-358-7571/7859 Telefax: 001-281-358-7861 Regional Office : Abu Dhabi, Dubai * 15.01.20