Electronic Controls Proportional Valve Control Power Plugs

Similar documents
Power Plugs for Proportional Valves (12 volt supply)

Coils and electronic controls

Functional Symbols and Application Notes

Continental Hydraulics Installation Manual CEM-AA-A

4/3 proportional directional control valve, without position control, with on-board electronics (OBE)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (0-10VDC Input Version)

Proportional Valves. Proportional solenoid valves for pressure and flow control

REMOTE MOUNT SOLENOID DRIVER (0-5 VDC/0-20 ma/10k Potentiometer Input)

Directional servo-valve of 4-way design

Pilot-Operated Proportional DC Valve Series D*1FH

Proportional Pressure Reducing Valve PDM08130

Vickers. Proportional Valves. EPV10 Series. Proportional Flow Controls. Released 6/95

Servo-Performance Proportional Directional Valves with Feedback Pressures to 315 bar (4500 psi) KBSDG4V-5 1* Series

Directional Controls

4/2 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

Proportional Valves. Proportional Two-Stage Directional Valves

4-way directional servo-valve

Proportional Valves. Proportional solenoid valves for pressure and flow control B-1.A. An Eaton Brand

Servo solenoid valves with on-board electronics (OBE)

4/3 directional control valve, pilot operated, with electric position feedback and integrated electronics (OBE)

Troubleshooting Bosch Proportional Valves

Servo and Proportional Valves

Servo solenoid valves with on-board electronics (OBE)

4/3 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

Proportional Directional Valves with Feedback. K(B)FD/TG4V-5, 12 Series Pressures to 315 bar (4500 psi)

TECHNICAL DATASHEET#TD1516AX 3 AMP SOLENOID DRIVER

VED05MG CONTINENTAL HYDRAULICS PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE VED05MG - PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE

Hydraulic Screw-in Cartridge Valves (SiCV) Proportional valves Proportional solenoid valves for pressure and flow control

Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback

Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback

Pilot operated proportional directional valves

Pilot Operated Proportional DC Valve Series D*1FW / D*1FT

Differential Pressure Sensors

Directional servo-valve in 4-way design

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

TD1512AX Technical Data. REMOTE MOUNT SOLENOID DRIVER (4-20mA Input Version)

Proportional flow control valve, 2-way version

VED05MJ - PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE & POSITION FEEDBACK

Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer

Proportional pressure relief valve Type DBETRE

Vickers. Proportional Valves. EPV16 Series Valvistor Proportional Flow Controls

Directional Controls. EMV-611e Electro-Hydraulic Mobile Control Valve Flows to160 l/min (42 USgpm) System Pressures to 320 bar (4600 psi)

Commercial Actuator Selection Chart Non-Spring Return

Servo solenoid valves with on-board electronics (OBE)

Lexium integrated drives

PROPORTIONAL PRESSURE RELIEF VALVES PILOT OPERATED WITH OBE

DC/DC converters - MINI-PS DC/ 5-15DC/

BTE2000 / PTE2000 Series Precision stainless steel pressure transmitters

PEAKTRONICS DMC-101 ADDITIONAL FEATURES. DC Motor Controller, 5A DMC-101

APPLICATION NOTES VALVE CHECKER M

Applications: General purpose industrial use with permanent magnet or shunt wound DC motors. Description

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

Lexium integrated drives

Industrial Hydraulics FAQs

Catalog HY /US SERIES DESCRIPTION PAGE NO. SUPER COILS CC... 1/2 Solenoid Tubes... CE3-CE4 CA... 5/8 Solenoid Tubes...

Servo solenoid valves with on-board electronics (OBE)

CONTINENTAL HYDRAULICS VED03MX

Differential Pressure Sensors

Publ. 3-EN 2950-A. DENISON HYDRAULICS Pressure Relief Valve R6V

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

Servo solenoid valves with positive overlap and on-board electronics

20 l/min (5 GPM) p max. Technical Features

Proportional flow control valve 2-way version, Type 2FRE 10, Huade América 1

Current Switches and Transducers

Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG iss 9 1

4-way directional servo valve Type 4WS.2E

Instruction Manual. ThinkTop D30 ESE02248-EN Patented Sensor System Registered Design Registered Trademark. Original manual _1

Sentronic PLUS 614 Series

2-way proportional throttle valve for block installation

PRM7-04. Functional Description HA /2012. Proportional Directional Control Valves. Replaces HA /2009

Specification subject to change without notice! All rights reserved page 1 of 5

4/3-Proportional Solenoid Valve direct acting with integrated Electronics Subplate to ISO4401 P4WEE 10

Q Range electric direct-drive quarter turn valve actuators. Instruction manual

Rexroth Hydraulics. Servo directional valve of 4-way design Type 4WS.2EM RE /03.99

PHOENIX CONTACT - 01/2008

Actuators for air dampers and control valves of oil burners

Proportional directional valves type DPZO-A* two stage without position transducer, ISO 4401 sizes 10, 16 and 25

Flow control valve range

Index. Index...pag.1. General features...pag.2 Mechanical features Available size. Electrical features pag.3 Protections Signalling Led

SOLENOID VALVES AND PNEUMATIC VALVES

Output Current Input Current Over Voltage. VDC VDC ma ma(typ.) ma(typ.) VDC μf % MKZI10-24S

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Actuators for air dampers and control valves of oil burners

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min

PRM7-06. Functional Description HA /2006. Proportional Directional Control Valves. Replaces HA /2002

PRM7-06. Functional Description HA /2014. Proportional Directional Control Valves. Replaces HA /2013

Proportional pressure reducing cartridges type LIRCZO normally closed, ISO 7368 sizes from 16 to 40

Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated

188 Dimensions: Inches [mm] In-line Version Solenoid valves assembled to manifolds ( Normally closed, orifice only. onsult ASO for alternative c

Proportional pressure relief valve, directly operated, rising characteristic curve

A1P OPERATING MANUAL

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250

Type Type 1001 Transducers. I/P & E/P Transducers

Controller. 1 Proportional amplifier module ESSK 106. ESSK 106 and ELSK Description. 1.2 Application examples. 1.

Servo solenoid valves with positive overlap and on-board electronics (OBE)

Mass Sine 24/10000 Mass Sine 24/15000

Pressure Transmitter JUMO dtrans p30 Type

DENISON HYDRAULICS Jupiter 500 Driver Card Series S

OEM Pressure Transmitters

Transcription:

Electronic ontrols Proportional Valve ontrol Power Plugs EHH-AMP-70-D/J/K-* Series For use with valve types: EPV**-D-* EFV-**-0DE* ERV/**-D-* EPRV**-D-* Application Primary applications are in the control of non-feedback proportional valves where the cost of more sophisticated electronic controls can be avoided. Type J is typically used in closed-loop applications. General Description Three types of plugs, conforming to ISO 00/DIN 3650 interface, with integral amplifiers and necessary adjustment potentiometers, are designed for use with non-feed back hydraulic valves. This plug/valve combination offers very low cost solutions to many hydraulic control problems requiring proportional control. Type D is controlled with a 0- command signal, and has adjustable gain, ramp, deadband compensation and dither. Type J, designed for closedloop applications, is controlled with a 0- command signal, and has no ramp function. Type K is controlled with a -0 ma command signal, and has an adjustable ramp time of 50 ms to 5s. Features and Benefits Integral amplifier provides essential functions for control of proportional valves Adjustable ramp time (types D and K), gain, deadband compensation and dither Ease of installation, with reduced cost Fully short-circuit and reverse-polarity protected Differential voltage command signal (types D and J) Adjustable dither EM to latest European standards Protection to IP67 Electrical Block Diagram EHH-AMP-70-D/J/K-* Note: This product has been designed and tested to meet specific standards outlined in the European Electro-magnetic ompatibility Directive (EM) 89/336/EE, amended by 9/6/EE, 9/3/EE and 93/68/EE, article 5. For instructions on installation requirements to achieve effective protection levels, see this leaflet and the Installation Wiring Practices for Vickers Electronic Products leaflet 68. Wiring practices relevant to this Directive are indicated by a warning symbol and Electromagnetic ompatibility (EM). Pow er input V D + + ommand signal 3? Ram p* Dither Gain Deadband Max. limiter PWM Pow er amp. X Solenoid X * Type J does not have the ramp function. -7.A

Model ode/ Operating Data Model ode EHH AMP 70 * * Adjustment Range D - Proportional plug: 0-0 VD with ramp J - Proportional plug: 0-0 VD without ramp function K - Proportional plug: -0 ma with ramp Design Number 0 Series Subject to change. Installation dimensions unaltered for design numbers 0 to 9 inclusives. Operating Data Electrical Types D and J Type K onnections V D OV (power and signal) 3 Positive command signal Negative command signal Power (input) supply 0-3 D including ± 0% maximum ripple (peak-to-peak) V D nominal Absolute maximum voltage Max. power consumption 35W including solenoid Reverse polarity protected Yes Short circuit protected Yes Maximum output current,6a Maximum output voltage typical Typically,5V below supply voltage (,6A output current) ommand signal 0- (0 kohms) -0 ma (50 ohms) Deadband triggering 00 mv ma For output (LED on) 00 mv to -0 ma For no output (LED off) 0 mv to 00 mv 0- ma Deadband adjustment range 00 to 000 ma Gain adjustment range 0.0A/V to 0.6A/V 0.0 A/mA to 0.08 A/mA Dither adjustment range 0 to 500 ma Ramp time (types D and K only) 50 ms to 5s PWM frequency 00 Hz ± 0% Dither frequency 0 Hz ± 0% Protection IE 59: IP67 (when correctly installed with interface seal in place) Fully short-circuit and reverse-polarity protected Isolation to VDE 00 Group B Electromagnetic compatibility (EM): Emission EN 5008- Immunity EN 5008- Mechanical Housing PA6 glass-reinforced plastic (conforming to UL-9HB). olor: gray Mounting interface ISO 00 (DIN 3650) able clamp Pg9 screw type able diameter Ø 5 to 0 mm (0.97 to 0.39 dia.) Wire section 0,5 to,0 mm (0-7 AWG) Temperature, ambient range -0 to +70 (- to +58 F) Mass 0,07 kg (0.5 lb) -8.A

Input/Output haracteristics Type K and D Type J ommand signal Type K 0 ma ma ma Type D 8V 6V V V ommand signal voltage U s 8V 6V V V Time Time Output current Ram p setting Output current U S X Gain sett ing Deadband compensation Time U S X Gain sett ing Deadband compensation Time Installation Dimensions mm (inch) 88 (3.5) (0.87) 3rd angle projection 39 (.5) Solenoid onnections (or ) No connection 3 (.3) 38 (.5) (or ) -9.A

Adjustments Ramp time: Turn clockwise to increase ramp time (Only types D/K). Gain: Turn clockwise to increase gain. Deadband compensation: Turn clockwise to increase deadband compensation current. Dither: Turn clockwise to increase the dither current. Terminal : Power Supply -3 D, positive. Terminal : Power Supply. Terminal 3: ommand signal positive (see Operating Data ). Terminal : ommand signal negative (see Operating Data ). LED Gain Ram p Deadband Dither 3 Installation Wiring Options Positive ommand Voltage + V EHH-AMP-70-D/J-0 3 Bi-polar omm and Voltage or f Operating Two Solenoids m fro One Signal EHH-AMP-70-D/J- + V 3 Negative ommand Voltage EHH-AMP-70-D/J-0 V 3 V 3 EHH-AMP-70-D/J- -0 ma ommand Signal V -0 ma EHH-AMP-70-K-0 3 onnections when replacing 0 design pow er plug with 0 design and only exist 3 wires EHH-AMP-70-D/J/K- V 3 Protective ground connection. Link pin to WARNING Electromagnetic ompatibility (EM) - Screened cables should be used and particular attention paid to the grounding of the screens as shown in the above diagrams. -0.A

Assembly Showing Wiring onnection Points WARNING Ensure cable clamp nut is adequately tightened to secure cable. Do not connect, or disconnect, the plug while power is on. Do not mount, or dismount, the plug while power is on. * Wiring Preparation x 0.5-.0 mm (0 AWG-7 AWG ) 5 (0.) Ø 5-0 (0.97-0.39 dia 0 (.6) * *All seals must be fitted correctly at plug installation to provide protection to IP67 (IE 59). -.A

Start-Up Procedure Spare Parts Ordering Procedure orrectly wire the plug and, before mounting it on the valve solenoid, apply V D (0 to 3 limits) to the power input terminals. heck for correct plug function by illumination/ non-illumination of the LED. The LED should illuminate when the demand applied to the signal input terminal is between 00 mv and (or ma and 0 ma) and should not be illuminated when the applied demand is less than 00 mv ( ma). If there is a malfunction a new plug must be fitted. Switch off power supply and command/input signal and then install plug on solenoid. Ensure that all seals are fitted correctly and clamped as the retaining screw is tightened: this is essential in providing IP67 protection. Ensure that the hydraulic system will not cause any erratic movement of actuators, then: Switch on power supply again. Repeat LED/function check as in. An LED malfunction now indicates a short circuit at the load. Successful completion of these checks means that the plug and load are ready for use. The only spare part available is the interface seal, part number 7300. Order plug by full model code, and spare interface seals by part number 7300. -.A

Electronic ontrols Soft Switch Power Plugs EHH-AMP-70--* 0 Series For use with valve types: EPV**-D-* EFV-**-0DE* ERV/**-D-* EPRV**-D-* Application Focus applications for this plug are in the control of hydraulic solenoid operated directional and pressure control valves where control of valve response time can significantly reduce shocks in the hydraulic system. Best results in reducing hydraulic shocks will only be obtained by using valves with the right low shock, or proportional features. General Description These plugs, conforming to ISO 00/DIN 3650 interface, offer adjustable, ramped on/off switching times through the use of an integral amplifier. The switching time range is 50 ms to 5 seconds. The soft switch plug is rated for V D nominal and controlled by a V logic signal. Applying an on signal causes the output current to ramp up to, and stay at, an adjustable maximum while the on signal is maintained. At switch-off the output current is ramped down to zero and will remain at zero until the next on signal. Features and Benefits Integral amplifier provides control from on/off logic command signal Adjustable ramp time Deadband compensation Adjustable output level Adjustable dither EM to latest European standards Improved switching time repeatability Fully short-circuit and reverse-polarity protected Protection to IP67 Ramp times (switching times) can be adjusted by an in-built potentiometer. An adjustment also allows for compensation of any deadband in the valve. Electrical Block Diagram EHH-AMP-70--* 0 Series Pow er input V D + Dither X Note: This product has been designed and tested to meet specific standards outlined in the European Electro-magnetic ompatibility Directive (EM) 89/336/EE, amended by 9/6/EE, 9/3/EE and 93/68/EE, article 5. For instructions on installation requirements to achieve effective protection levels, see this leaflet and the Installation Wiring Practices for Vickers Electronic Products leaflet 68. Wiring practices relevant to this Directive are indicated by a warning symbol and Electromagnetic ompatibility (EM). ommand Signal 3 (N) k7w Ram p Gain Deadband Max. limiter PW M Pow er amp. Solenoid X -3.A

Model ode/ Operating Data Model ode Operating Data Electrical EHH AMP 70 * Design Number 0 Series Subject to change. Installation dimensions unaltered for design numbers 0 to 9 inclusives. onnections V D OV (power and signal) 3 Positive command signal Negative command signal Power (input) supply 0-3 D including ± 0% maximum ripple ripple (peak-to-peak) V D nominal Absolute maximum voltage Max. power consumption 35W including solenoid Reverse polarity protected Yes Short circuit protected Yes Maximum output current,6a Maximum output voltage typical Typically,5V below supply voltage (,6A output current) ommand signal For output (LED on) 5V to V For no output (LED off) to 5V Input impedance 700 ohms Deadband adjustment range <00-000 ma Gain adjustment range 0.0A to,6a (maximum) Dither adjustment range 0 to 500 ma Ramp time 50 ms to 5s PWM frequency 00 Hz ± 0% Dither frequency 0 Hz ± 0% Protection IE 59: IP67 (when correctly installed with interface seal in place) Fully short-circuit and reverse-polarity protected Isolation to VDE 00 Group B Electromagnetic compatibility (EM): Emission EN 5008- Immunity EN 5008- Mechanical Housing PA6 glass-reinforced plastic (conforming to UL-9HB). olor: gray Mounting interface ISO 00 (DIN 3650) able clamp Pg9 screw type able diameter Ø 5 to 0 mm (0.97 to 0.39 dia.) Wire section 0,5 to,0 mm (0-7 AWG) Temperature, ambient range -0 to +70 (- to +58 F) Mass 0,07 kg (0.5 lb) -.A

Input/Output haracteristics Functions Switch-on/off: after switching on with a 5V signal the amplifier will remain in the on condition with a command signal above 6V. The command signal must be reduced to below 5V to achieve switch-off of the amplifier. ommand signal V, typical Output current Ram p time Time Gain adjustment Deadband compensation Time Installation Dimensions mm (inch) 88 (3.5) (0.87) 3rd angle projection 39 (.5) Solenoid onnections (or ) No connection 3 (.3) 38 (.5) (or ) -5.A

Adjustments Ramp time: Turn clockwise to increase ramp time. Gain: Turn clockwise to increase gain. Deadband compensation: Turn clockwise to increase deadband compensation current. Dither: Turn clockwise to increase the dither current. Terminal : Power Supply -3 D, positive. Terminal : Power Supply. Terminal 3: Switch command signal positive. Terminal : Not connected LED Gain Ram p Deadband Dither 3 Installation Wiring WARNING Electromagnetic ompatibility (EM) - Screened cables should be used and particular attention paid to the grounding of the screens as shown in the above diagram. V >5V Protective ground connection 3-6.A

Assembly Showing Wiring onnection Points WARNING Ensure cable clamp nut is adequately tightened to secure cable. Do not connect, or disconnect, the plug while power is on. Do not mount, or dismount, the plug while power is on. * Wiring Preparation x 0.5-.0 mm (0 AWG-7 AWG ) 5 (0.) Ø 5-0 (0.97-0.39 dia 0 (.6) * *All seals must be fitted correctly at plug installation to provide protection to IP67 (IE 59). -7.A

Start-Up Procedure orrectly wire the plug and, before mounting it on the valve solenoid, apply V D (0 to 3 limits) to the power input terminals. heck for correct plug function by illumination/ non-illumination of the LED: a. Apply less than to 3 volts to the input terminal: LED should not be illuminated. b. Increase voltage: the LED should illuminate when the voltage reaches 5V. Do not exceed 3 command signal. c. Decrease voltage: the LED should go off when the voltage is less than 5V. Switch off power supply and command/input signal and then install plug on solenoid. Ensure that all seals are fitted correctly and clamped as the retaining screw is tightened: this is essential in providing IP67 protection. Ensure that the hydraulic system will not cause any erratic movement of actuators, then: Switch on power supply again. Repeat LED/function check as in. An LED malfunction now indicates a short circuit at the load. Successful completion of these checks means that the plug and load are ready for use. Spare Parts The only spare part available is the interface seal, part number 7300. Ordering Procedure Order plug by full model code, and spare interface seals by part number 7300. -8.A