Linear fittings EVN Fluorescent fitting - zones 2 & 22

Similar documents
Linear fittings EVT Weatherproof fluorescent fitting - Industrial applications

Linear fittings Fluorescent fitting EVN - Zones 2 & 22

Linear fittings EVNL LED fitting - zones 2, & 22

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22

Linear fittings EVD Fluorescent fitting - zones 21 & 22

Linear fittings EVDL LED fitting - zones 21, & 22

Linear fittings EVTL Weatherproof LED fitting - Industrial applications

Linear fittings EVTL Weatherproof LED fitting - Industrial applications

Linear fittings EVT Weatherproof fluorescent fitting - Industrial applications

Floodlight fittings HPS, MH or Halogen Floodlight fitting XSF, XQF, XEF - Zones 1, 2

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

ATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22

Easy and safe installation

Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety

EXEL-L. Detail of the internal side. Transparent polycarbonate

Emergency Luminaire with LED Series EXLUX 6409/1

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Linear Luminaire with LED Series EXLUX 6402/2

ATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

PROTECTA III. Construction Tough glass reinforced polyester body

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Lighting: Fluorescent Lighting FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Zone 2 & 22

LED Linear Luminaire Series EXLUX 6402

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

FL Series Light Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2 and 22

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)

Emergency Light Fitting for Fluorescent Lamps Series 6009

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Linear Luminaire with LED Series EXLUX 6002

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Linear luminaire with LED Series EXLUX 6002

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Floodlight LED Series 6525

Floodlight LED Series 6525

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13

Floodlight LED Series 6125

EXENC-L. - Zone 2, Zone Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components

Compact Sheet-Steel Light Fittings Series 6114/1

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof

Lighting: Incandescent & HID Lighting PB, PC & PL Series: Floodlights Flameproof

7 Lighting Technology

7 Lighting Technology

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

AVN. - Zone 2, 21, 22 - Lower maintenance costs - Easy to install - Suited to ambient temperatures of up to +55 C. Ex n. Stainless steel clips

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L

Linear fluorescent luminaire LED V-CG-S

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

ATX PC Series Floodlights Flameproof. Metal Halide, High Pressure Sodium, Mercury Vapor, Halogen

J: Emergency lighting (optional) L: pole type X: ceiling type Mounting

7 Lighting Technology

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

EX-REPAIR AND MAINTENANCE RECEPTACLES

Start Waterproof LED G3 fixed output START WATERPROOF LED G3 1500MM T 4K

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Compact Sheet-Steel Light Fittings Series 6114

Sheet Steel Emergency Light Fitting Series 6018

TUNNEL54. Safety and fire resistance VENTILATION LIGHTING

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations

IP65 FLUO 2X18W 2X36W

explosive environments Lighting

Sheet-Steel Light Fittings Series 6014 / 6414

SPECIFICATION SHEET ORION ROAD LANTERN. IP66 RATED CRI. 230v /50hz

Protecta Ex na Fluorescent Luminaire

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

EX-RECESSED CEILING LIGHT FITTINGS

Floodlight Series 6121

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008

Waterproof TCW060 just light

HAZ AREA LIGHTING. Product Brochure. Design to Manufacture FOR HAZARDOUS AREAS. Engineering Solutions. An A-Belco Group Company

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W, 1000 W HID Light Level Equivalent

ATX PRE Series 63 Amp Plugs and Sockets Increased Safety

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

Zone 1 Linear Range - Installation Guide

I Ex-Safety switches I

7 Lighting Technology

The ultimate low voltage temporary LED lighting solution

The ultimate low voltage temporary LED lighting solution

Junction Boxes & Enclosures JBES and ECES Series: 316L Stainless Steel Enclosures Increased Safety

Transcription:

LIEAR FITTIGS - EV FLUORESCET FITTIG - ZOES 2 & 22 71 EV Fluorescent fitting - zones 2 & 22 Features Double central locking for ingress protection All components mounted on hinged and removable gear tray which gives easy access for maintenance Including accessories (cable gland, plugs & fixing brackets) EV Linear fluorescent fitting Approvals & certifications ExnA Extc Specifications Main body constructed of glass reinforced polyester for high impact strength UV protected polycarbonate diffuser to resist harsh environments Approved to: EC Type examination certificate to: Standards E 60079-0 : General requirements E 60079-15 : Enclosure n E 60079-31 : Enclosure t Directive 2014/34/EU LCIE 15 ATEX 1010X G IIC GROUP II ZOE 2 IIIC D ZOE 22 IP 66 IK 10 Rated voltage 108-4Vac or dc Wiring configuration: 5 wires 3x entries M20 Emergency version with self- test (type: EMB version 3h battery duration) EMC Directive (2004/108/CE) - April 2016 (2014/30/UE) IECEX LCIE 15.0018X II 3 G Ex na IIC T4 Gc for -40 C to +40 C Ex na IIC T3 Gc for -40 C to +60 C II 3 D Ex tc IIIC T65 C Dc IP66 for -40 C to +40 C Ex tc IIIC T85 C Dc IP66 for -40 C to +60 C E 55015 : Conducted emission test and radiated emission test E 61547 : CEM immunity E 61000-3-2 : Harmonic current Emissions Class C 01 Hinged & removable gear tray 02 Double central locking Low voltage Directive (2006/95/CE) - April 2016 (2014/35/UE) Glow wire test: E 61000-3-3 : Limitation of voltage changes and flickers E 60598-1 : Luminaire general requirements and tests, including dielectric strength and isolation resistance 960oC 01 02 Operating temperature: IP test: -20 C to +55ºC EV -10 C to +50ºC EV EMB IEC 60529: IP66 Impact protection index: IEC 62262: IK10

72 LIGHT FITTIGS, BOXES & CUSTOM BUILT COTROL PAELS FOR EXPLOSIVE ATMOSPHERES EV fluorescent fitting - zones 2 & 22 EV Linear fluorescent fitting 5 wires Glass Diffuser Suitable for use in Zones 1, 2, 21, 22 Dimensions 2 x M8 hole 20mm depth C B 137 mm EV 5 wires: Equipped w with 1 cable gland & 2 plugs A 170 mm Type For Wiring Light Current A Dimensions mm Weight non armored cable armored cable Configuration Rating W @ 230V A B C kg EV120-0000 EV120-D000 5 wires* 1 x 18 0.09 785 432 400 4.40 EV140-0000 EV140-D000 5 wires* 1 x 36 0.17 1 370 900 700 7.60 EV165-0000 EV165-D000 5 wires* 1 x 58 0.26 1 670 900 700 8.80 EV220-0000 EV220-D000 5 wires* 2 x 18 0.17 785 432 400 4.40 EV240-0000 EV240-D000 5 wires* 2 x 36 0.33 1 370 900 700 7.60 EV265-0000 EV265-D000 5 wires* 2 x 58 0.50 1 670 900 700 8.80 EV 5 wires: Equipped w with 2 cable glands & 1 plug EV120-B000 EV120-E000 5 wires through** 1 x 18 0.09 785 432 400 4.40 EV140-B000 EV140-E000 5 wires through** 1 x 36 0.17 1 370 900 700 7.60 EV165-B000 EV165-E000 5 wires through** 1 x 58 0.26 1 670 900 700 8.80 EV220-B000 EV220-E000 5 wires through** 2 x 18 0.17 785 432 400 4.40 EV240-B000 EV240-E000 5 wires through** 2 x 36 0.33 1 370 900 700 7.60 EV265-B000 EV265-E000 5 wires through** 2 x 58 0.50 1 670 900 700 8.80 ote. * For armored cable with 1 continuity plate. ** For armored cable with 2 continuity plates. Technical information Lamps Fluorescent Lamp (order separately) T8 bi-pin tube, lampholder G13, diameter 26mm - white industry 4 000 K Photometric curve See page 189 Rated voltages Electronic ballast: 108-4Vac or dc. EOL (End of life) the ballast prevents the lamp cap at the end of lamp life cycle from overheating Power factor 0.98 CRI 80 Wiring Configuration 5 wires Dielectrical class I Grounding system TS, TC, TT, IT neutral system Terminal block (screws) 6mm² (rigid wire), 4mm² (flexible wire) Terminals supplied L1, L2, L3,, PE (looping possible with one additional cable gland) Technical information Cable entries For non-armoured cable: For armoured cable: Housing Fixing (included with product) Three entries M20 Included two M20 nylon plugs (EX-M20) and one M20 nylon cable gland, diameter 6-12mm (EXCGM20S) included continuity plate - two M20 n ylon plugs (EX-M20) and one M20 nickel plated brass cable gland, diameter 6-12/ 8.5-16mm (EX04MMC1) Fiberglass reinforced polyester housing for high impact strength, UV protected polycarbonate diffuser to resist harsh environments, Painted steel gear tray & Stainless steel 316L insert V015-2x Two zinc-plated steel brackets f or ceiling mounting

LIEAR FITTIGS - EV EMB EMERGECY FLUORESCET FITTIG - ZOES 2 & 22 73 EV EMB Emergency fluorescent fitting with self-test - 3h - zones 2 & 22 5 wires: Equipped with 1 cable gland & 2 plugs Type For Wiring Light Battery Current A Dimensions mm Weight non armored cable armored cable Configuration Rating W h @ 230V A B C kg EV120EMB-0000 EV120EMB-D000 5 wires* 1 x 18 3h 0.09 785 432 400 5.80 EV140EMB-0000 EV140EMB-D000 5 wires* 1 x 36 3h 0.17 1 370 900 700 9.00 EV165EMB-0000 EV165EMB-D000 5 wires* 1 x 58 3h 0.26 1 670 900 700 10.60 EV220EMB-0000 EV220EMB-D000 5 wires* 2 x 18 3h 0.17 785 432 400 5.80 EV240EMB-0000 EV240EMB-D000 5 wires* 2 x 36 3h 0.33 1 370 900 700 9.00 EV265EMB-0000 EV265EMB-D000 5 wires* 2 x 58 3h 0.50 1 670 900 700 10.60 ote. * For armored cable with 1 continuity plate. For dimensional drawing, please refer to page 72 Electrical Features Lamps Fluorescent Lamp (order separately) T8 bi-pin tube, lampholder G13, diameter 26mm - white industry 4 000 K Photometric curve See page 189 Rated voltages Electronic ballast: 108-4Vac or dc EOL (End of life) the ballast prevents the lamp cap at the end of lamp life cycle from overheating. Power factor 0.98 CRI 80 Wiring Configuration 3 wires Battery Battery icd 6V 4Ah for EV120, EV220 Battery icd 6V 7Ah for EV140, EV240, EV165, EV265 Lumen output in emergency mode (1 lamp lit) 3 hours: 24% for EV120, EV220 3 hours: 18% for EV140, EV240 3 hours: 14% for EV165, EV265 Bs Bs Monitored by LED Electrical Features Dielectrical class Terminal block (spring) Cable entries For non-armoured cable: For armoured cable: Housing Fixing (included with product) E Ls Ls L1 L1 L2 L3 E I Jumped bar x2 terminal blocks 4mm² (rigid wire), 2.5mm² (flexible wire) Terminals supplied L1, L2, L3, LS,, E, BS (looping possible with one additional cable gland) Three entries M20 Included: One 3/4 nickel plated brass plug (EX/075/SP) and one 3/4 nickel plated brass cable gland for non armoured cable, diameter 6-12mm (EX05ASC3) included continuity plate - two M20 n ylon plugs (EX-M20) and one M20 nickel plated brass cable gland, diameter 6-12/ 8.5-16mm (EX04MMC1) Fiberglass reinforced polyester housing for high impact strength, UV protected polycarbonate diffuser to resist harsh environments, Painted steel gear tray & Stainless steel 316L insert V015-2x Two zinc-plated steel brackets f or ceiling mounting Emergency function diagrams Wiring provided by DTS Maintained Mode Mains Supply Tube Battery O Lit Charging s Ls L1 L OFF Only emergency Bs Bs tube lit Discharging E L3 E Switch between L/2 on Maintained Mode * Mains Supply Tube Battery O OFF Charging Ls Ls L1 L1 L2 OFF Only emergency tube lit Discharging 1 0 * This table corresponds to the position 0 open. If the switch is on position 1 close, refer to the table on the left Battery charge - 4 months Battery charge capacity during 3hr - quarterly Clear system test display by LED Battery charge monitoring with LED - Mains O Green LED lit Healthy (Test OK) Green LED Batteries are charged Green & red LED light up alternately (2s) Battery test in progress Red LED Fault (replace battery) Yellow LED Battery Test Fault Red LED lit Emergency mode Mains OFF Red LED Battery discharged

74 LIGHT FITTIGS, BOXES & CUSTOM BUILT COTROL PAELS FOR EXPLOSIVE ATMOSPHERES - accessories EV - zones 2 & 22 Bipin T8 fluorescent lamps Type Power W Lumen output lm Lampholder TL18W 18 1 0 G13 TL36W 36 3 350 G13 TL58W 58 5 200 G13 Specifications G13 - ø 26mm Colour temperature: White industry 4 000 K CRI: > 80 lm/w: 65 to 93 Average operating life: 12 000 hours Fixing accessories* Brackets Type Specifications V015 2 x pair of zinc plated steel for ceiling mounting (Included with product) ø9 V016 Stainless steel 316L brackets for ceiling mounting 160 200 Hook Type Specifications 20 V024 2x Zinc plated steel suspension hook M Hook Type Specifications V014 2x Rapid ceiling mounting with stainless steel clip 60, 2 Ø 8.5 Fixing bracket and flange Type Specifications V018 2x zinc plated steel pole mounted brackets for ø1 ¼ & 1 ½ 100 M8 V019 2x zinc plated steel pole mounted brackets for ø2 V021 2x Stainless steel 316L pole mounted brackets for ø1 ¼ & 1 ½ V022 2x Stainless steel 316L pole mounted brackets ø2 α ø9 ~70 41 * Screws and locknuts supplied

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 SAUF IDICATIO COTRAIRE: FIITIO: LES COTES SOT E MILLIMETRES ETAT DE SURFACE: TOLERACES: LIEAIRES: AGULAIRES: OM SIGATURE DATE AUTEUR VERIF. APPR. FAB. QUAL. MATERIAU: MASSE: CASSER LES E PAS CHAGER L'ECHELLE AGLES VIFS TITRE: o. DE PLA ECHELLE:1:5 REVISIO FEUILLE 1 SUR 1 A0 A B C D E F G H J K L M P Q LIEAR FITTIGS - EV FLUORESCET FITTIG - ZOES 2 & 22 75 - spare parts EV - zones 2 & 22 Spare parts Type Specifications V00120W 20W diffuser with gasket for EV. range V00140W 40W diffuser with gasket for EV. range V001 V00165W 65W diffuser with gasket for EV. range V0041X20WE Gear tray 1x18W with electronic ballast 110-260V 50-60Hz for EV120 V004 V0041X40WE Gear tray 1X36W with electronic ballast 110-260V 50-60Hz for EV140 V008 V0041X65WE Gear tray 1X58W with electronic ballast 110-260V 50-60Hz for EV165 V0042X20WE Gear tray 2X18W with electronic ballast 110-260V 50-60Hz for EV220 V0042X40WE Gear tray 2x36W with electronic ballast 220-240V 50-60Hz for EV240 V0042X65WE Gear tray 2x58W with electronic ballast 220-240V 50-60Hz for EV265 V0041X20WEMB Emergency gear tray 1x18W with electronic ballast 220-240V 50-60Hz for EV120EMB EVD 140-240 (toutes config.) V0041X40WEMB Emergency gear tray 1x36W with electronic ballast 220-240V 50-60Hz for EV140EMB V0041X65WEMB Emergency gear tray 2x18W with electronic ballast 220-240V 50-60Hz for EV220EMB V0042X20WEMB Emergency gear tray 2x36W with electronic ballast 220-240V 50-60Hz for EV240EMB V0042X40WEMB Emergency gear tray 1x58W with electronic ballast 220-240V 50-60Hz for EV165EMB V0042X65WEMB Emergency gear tray 2x58W with electronic ballast 220-240V 50-60Hz for EV265EMB V008 Bi-pin G13 lampholder V020x40W Brass continuity plate for EV. 120, EV. 220, EV. 140, EV. 240 V065W Brass continuity plate for EV. 165, EV. 265 EXCGM20S M20 Exe IIC nylon cable gland for non armoured cable diameter 6-12mm, locknut available separately as LPB/M20 EX04MMC1K Kit M20 Ex-d IIC Ex-e II Ex-td double compression nickel plated cable gland for armoured cable diameter inner 6-12 outer 8.5-16mm locknut, sealing gasket