S2n1 PREASSEMBLED SUMP PUMP SYSTEM

Similar documents
PREINSTALLATION CHECKLIST

CAUTION PREINSTALLATION CHECKLIST. visit our web site: Your Peace of Mind is Our Top Priority. Section: 6.10.

12 VOLT DC BATTERY BACKUP PUMP PREINSTALLATION CHECKLIST

507/53 507/98 CAUTION. NOTICE TO INSTALLER: Instructions must remain with installation. Your Peace of Mind is Our Top Priority

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

SUBMERSIBLE SUMP PUMPS

SUBMERSIBLE SUMP PUMPS

MODEL 510 THE BASEMENT SENTRY II 12 VOLT DC BACKUP PUMP

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

PRE-PLUMBED SEWAGE SYSTEM

12 VOLT DC BATTERY BACKUP PUMP PREINSTALLATION CHECKLIST

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

MODEL 585 BATTERY BACKUP PEDESTAL SUMP PUMP PREINSTALLATION CHECKLIST SEE BELOW FOR LIST OF WARNINGS CAUTION SEE BELOW FOR LIST OF CAUTIONS

AUTOMATIC SUBMERSIBLE UTILITY PUMP

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

GARDEN HOSE UTILITY PUMP

INSTALLATION INSTRUCTIONS RECOMMENDED MODELS

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

DRAIN PUMP SYSTEM MODEL 105 (Korean) INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

Matala. VersiFlow Series. Instruction and Maintenance Manual

ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.

ESE Series Cast Iron Sewage Pumps

StormPro BCV400 Sewage Ejector Pump

STAR STOP SHALLOW WELL JET PUMP

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

StormPro BA Series Sump Pump

SHALLOW WELL JET PUMP

GeyserMax-Flow Series

INSTALLATION & OPERATION MANUAL

ON-SITE WASTEWATER PRODUCTS

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL

OWNER S MANUAL. INSTALLATION AND OPERATION INSTRUCTIONS FOR 12 VOLT BATTERY BACK-UP SYSTEM Models: 92900, 92910

OWNER S MANUAL Commercial Duty Pumps

12 VOLT DC BATTERY BACKUP PUMP INSTALLATION INSTRUCTIONS

Owner s Manual Drill and Light Weight Portable Utility Pumps

OWNER S MANUAL INSTALLATION AND OPERATION INSTRUCTIONS

RETROFIT SYSTEMS INSTALLATION AND SERVICE MANUAL. Engineered for quick and easy replacement of existing progressive cavity grinder systems.

OWNER S MANUAL. Submersible Sump Pumps Models: XQS33 (1/3 HP Sump Pump) XQS50 (1/2 HP Sump Pump) Suzhou Xin Qi Electric Co.,ltd

Installation Operation Parts

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

Installation Manual. D3600- Series Duplex Grinder Systems. Contents

QWIK JON ULTIMA 203 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

Pump Sentry. Models 812 PS & 1612 PS INSTALLATION INSTRUCTIONS

2460 / 2472 / Series Simplex Grinder Systems

Ion Technologies SHR-HR Submersible Sewage Pump Single Seal, Single Phase, & Three Phase Power

MODEL MRG20 GRINDER PUMP INSTALLATION AND SERVICE MANUAL. 2 HP Grinder Pump for Residential Applications.

Installation Manual. Q Series Quadplex Grinder Systems. Contents

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

MODEL H INSTALLATION INSTRUCTIONS

Pump Installation and Service Manual HRS Hydromatic Retractable System

PUMP SPY INSTALLATION AND OPERATING INSTRUCTIONS

PUMP VAULT S.T.E.P. SYSTEM

SPC-PANEL Simplex, Single Phase Pump Control Panel

OWNER S MANUAL. ZOELLER HAZARDOUS ENVIRONMENT PUMPS (For Class I, Division 1, Groups C & D Applications) Explosion Proof Motors

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

STEP-BY-STEP INSTALLATION GUIDE

EBARA Fluid Handling

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

HALLMARK INDUSTRIES INC

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

IMPORTANT SAFETY INSTRUCTIONS

Owner s Manual GLASSLINED PUMP TANK

Cone Skimmers. Instructions. for Models 75G, 150G and 300G. Please read these instructions in their entirety before attempting to use this product.

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

Ion Technologies WC33 Submersible Sump Pump

Installation Manual. Engineered Pump Systems (EPS) Common Components: Manual Contents:

SPECIFICATIONS EFFLUENT/SUMP SIMPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

Installation & Operating Manual

INSTRUCTIONS AND SERVICE MANUAL WITH PARTS LIST

HV200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

SHEF30 Submersible Sump/ Effluent Pump

Models: SP3, SPSS3 Automatic Battery Charger

Installation Manual. Omnivore Grinder Pump Retrofit Unit LSG202-RE. LSGX202-RE 2Hp, V, 1 phase, Automatic LSG202-REX

O W N E R ' S M A N U A L

SUBMERSIBLE SWIMMING POOL DRAINER

SP6. Automatic Battery Charger. Model

Air Curtain. Installation, Operating and Maintenance Instructions

V2 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English...

Submersible Effluent Pump

INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR MODELS K4RP & K4VP SUBMERSIBLE SOLIDS-HANDLING SEWAGE PUMPS

MODELS WGL20, WGL20H and WGL20F

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

Cruising Charger Series OWNER S MANUAL

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

s4.5mp s4.5 MP System Owner s Manual Architects and custom home builders Everything you need to know.

Level One Electric Vehicle Charging Station FREE STANDING Product Guide

SUNC3000 / Item #40885

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual

Pump Installation and Service Manual JB-1 System Sewage Ejector Pump Package

801 BUSINESS CENTER DRIVE MOUNT PROSPECT, ILLINOIS

Hazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual

Stormpro 2100-DC. OPERATION MANUAL Heavy Duty 12V DC Pump Dated: 04/24/08 Supersedes: 02/04/08 Document No.: Spro2011-DC-OM Page 1 of 7

Transcription:

NOTICE TO INSTALLER: Instructions must remain with installation. Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. STAR 95 North Oak Street Kendallville, IN 46755 800-742-5044 FW1286 0611 Supersedes 0809 visit our web site: starwatersystems.com S2n1 PREASSEMBLED SUMP PUMP SYSTEM WITH BATTERY BACKUP 12V DC BATTERY BACKUP SYSTEM WITH 120V AC POWERED SUMP PUMP MODEL 3SDHL PRE-INSTALLATION CHECKLIST 1. Inspect your pump. Occasionally, products are damaged during shipment. If the unit or any of the parts are damaged, contact your dealer before using. 2. Read all the installation instructions regarding installing and start up. Retain for future reference. 1. WARNING: Make certain that the receptacle is within the reach of the pump s power supply cord. DO NOT USE AN EXTENSION CORD. Extension cords that are too long or too light do not deliver sufficient voltage to the pump motor. But, more important, they could present a safety hazard if the insulation were to become damaged or the connection end were to fall into the sump. 2. WARNING: Make sure the pump electrical supply circuit is equipped with fuses or circuit breakers of proper capacity. A separate branch circuit is recommended, sized according to the National Electrical Code for the current shown on the pump nameplate. 3. WARNING: Testing for ground. As a safety measure, each electrical outlet should be checked for ground using an Underwriters Laboratory Listed circuit analyzer which will indicate if the power, neutral and ground wires are correctly connected to your outlet. If they are not, call a qualified licensed electrician. 4. WARNING: For Added Safety. Pumping and other equipment with a 3-prong grounded plug must be connected to a 3-prong grounded receptacle. For added safety the receptacle may be protected with a ground-fault circuit interrupter. When a pump needs to be connected in a watertight junction box, the plug can be removed and spliced to the supply cable with proper grounding. For added safety this circuit may be protected by a ground-fault circuit interrupter. The complete installation must comply with the National Electrical Code and all applicable local codes and ordinances. 5. WARNING: FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS POWER SOURCE BEFORE HANDLING. Single phase pumps are supplied with a 3-prong grounded plug to help protect you against the possibility of electrical shock. DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE GROUND PIN. The 3-prong plug must be inserted into a mating 3-prong grounded receptacle. If the installation does not have such a receptacle, it must be changed to the proper type, wired and grounded in accordance with the National Electrical Code and all applicable local codes and ordinances. Pumps must be installed in accordance with the National Electrical Code and all applicable local codes and ordinances. Pumps are not to be installed in locations classified as hazardous in accordance with National Electrical Code, ANSI/ NFPA 70. 6. WARNING: Risk of electrical shock Do not remove power supply cord and strain relief or connect conduit directly to the pump. 7. WARNING: Installation and servicing of electrical circuits and hardware should be performed by a qualified licensed electrician. 8. WARNING: Pump installation and servicing should be performed by a qualified person. 9. WARNING: Risk of electric shock - These pumps have not been investigated for use in swimming pool and marine areas. 10. WARNING: According to the state of California (Prop 65), this product contains chemicals known to the state of California to cause cancer and birth defects or other reproductive harm.

11. CAUTION: Check to be sure your power source is capable of handling the voltage requirements of the motor, as indicated on the pump name plate. 12. CAUTION: The installation of automatic pumps with variable level float switches or nonautomatic pumps using auxiliary variable level float switches is the responsibility of the installing party and care should be taken that the tethered float switch will not hang up on the pump apparatus or pit peculiarities and is secured so that the pump will shut off. It is recommended to use rigid piping and fittings and the pit be 18" or larger in diameter. 13. CAUTION: Information - vent hole purpose. It is necessary that all submersible sump pumps capable of handling various sizes of solid waste be of the bottom intake design to reduce clogging and seal failures. A check valve with an integral weep hole is incorporated in the installation to purge the unit of trapped air (See Page 4). Trapped air is caused by agitation and/or a dry basin. Vent hole should be checked periodically for clogging. NOTE: THE HOLE MUST BE CLEANED PERIODICALLY. Water stream will be visible from this hole during pump run periods. 14. CAUTION: Pump should be checked frequently for debris and/or build up which may interfere with the float on or off position. Repair and service should be performed by Star Water Systems Authorized Service Station only. 15. CAUTION: Sump pumps are not designed for use in pits handling raw sewage. 16. CAUTION: Maximum operating temperature for standard model pumps must not exceed 104 F (40 C). Note: Pumps with the "ccsaus" mark are tested to UL Standard UL778 & CSA Standard C22.2 No. 108. GENERAL INFORMATION The 2N1 system is designed to provide a primary and a backup sump pumping capabilities. The primary pump will operate as long as it is receiving AC electrical power. The AC power is interrupted, the backup sump pump will begin pumping automatically. The primary pump, backup pump, electronic controls and all parts required for installation are included except the battery which is supplied by the user. 1. The primary pump is equipped with an omnidirectional mechanical float switch. The pump will turn on automatically when the water level in the sump reaches approximately 10.25 and automatically turn off when the water is pumped down to 4.125. The back-up pump is equipped with a vertical float switch. The pump will turn on automatically when the water level in the sump reaches approximately 11 and automatically turn off when the water is pumped down to 9.25. 2 2. The sump pit must be a minimum of 22" deep and 18" in diameter. The pump assembly requires a minimum diameter of 18" so that the float switches will operate without restriction. Any smaller diameter may restrict the switches operation, resulting in pump failure. INSTALLATION 1. 1. For your safety, turn off the electrical power at the service entrance to avoid any possible electrical shock hazards. 2. On a replacement installation, remove the existing pump from the sump by disconnecting the discharge pipe or hose from the old pump. Depending on how your old pump is installed, unscrew clamps and discard old corrugated hose, or unscrew galvanized or plastic pipe from pump discharge. If discharge pipe cannot be removed easily, saw through the pipe about five feet above the pump discharge. 3. After removing the old pump, remove sediment, debris, and any standing water from the sump pit. 4. Place your pump assembly in the sump and attach the discharge piping The pipe must be supported from above to ensure adequate support for the pump assembly. 5. Be sure that the pump assembly is positioned so that the float switches move freely without touching the wall of the sump or other obstructions. (See Fig. 1) Ensure that the off level of the float is 1" min. above the discharge tee of the DC backup pump (see Fig. 1). Move floats up and down, making sure of free movement without interference from any obstructions inside the sump or lid. Very shallow sumps may require some adjustment to the vertical float to avoid overfilling or backing up of water into the sump inlet. Battery Box See Detail A Check Valve Pump Discharge Detail A Charger Outlet Primary Pump Outlet Must be installed on two separate circuits IMPORTANT: Off level of float assembly must be 1 in. minimum above center of tee. 1 in. min. Weep Hole Provided FIGURE 1 - DC PUMP PLUMBED IN LINE WITH SUBMERSIBLE PUMP IL1007

6. Do not allow the cords to interfere with the float control motion or to drape over the pump motor. With electrician's tape, secure the cord to the discharge pipe. This will provide protection for the cord and make a neat installation. 7. Install DC control charger (see Fig. 2) by using the wall bracket and anchors provided. If more convenient, the control charger may be set on a nearby shelf or ledge. The control charger should be located 3 or 4 ft. above the sump. To reduce noise from vibration, it is recommended that the charger be anchored with the wall bracket provided. 8. Connect the leads from the control charger to the battery terminals. Red pos. (+) lead to positive terminal and black neg. (-) lead to negative battery terminal. Upon proper connection, test alarm will sound. Press alarm reset to silence. This indicates proper charger to battery connection. Correct battery hook up is essential for operation of the system. Use wing nuts supplied with battery and eyelet connectors on battery wire leads. The positive terminal is the larger stud, 3/8" diameter. The smaller stud, 5/16" diameter is the negative terminal. Apply grease to the terminals to help prevent corrosion. 9. Connect the black lead from the pump to the negative (-) battery terminal. Connect the white or red lead from the pump to the white lead from the switch. This connection is made at the fuse installed on the switch wire (see Fig. 2). Connect the black lead from the switch to the positive (+) battery terminal. 10. Connect the blue sensor wire to the sensor connector (Fig. 2). 11. Close battery box and secure cover with the safety closure strap provided. Carpeted or wood barrier between the battery case and the floor is recommended. 12. Plug the control power cord into the 115V wall outlet. The primary sump pump and the control box should be on separate circuits. 13. Plug in primary pump and restore electrical power at the service entrance. Initial Start-Up and Operation 1. Test the installation for leaks by running water into the sump allowing for normal operation of the primary pump. 2. Check the control charger. The red power on light will be lit when the unit is plugged into the 115V wall outlet. The yellow/green light will indicate the condition of the battery. 3. Disconnect primary pump before touching any component in the sump pit. 4. Lift float switch. The DC backup pump will run and the alarm will sound. Lower float switch immediately after pump has started running. Pump is running dry during initial check out for several seconds. CAUTION Continuous dry running may cause overheating and damage the pump seals. Upon release of the float switch, the pump will shut off. Press the reset button to turn the alarm off. Float Switch Clamp 15 Amp Fuse DC Back-up Pump White Lead to DC Pump Black Lead to Positive DC Control Box White or Red Lead to Float Splicer Blue Lead to Float Switch Black with Red Tracer to Positive Black Lead to Negative Battery Box 12 Volt Marine Battery Supplied by User FIGURE 2 Safety Closure Strap Black Lead to Negative 3 IL1008

5. Complete the final testing of your installation by disconnecting the power to the primary pump and the control charger by removing the plugs from the 115V wall outlets. Run water into the sump until the DC backup pump is activated by the float switch. Check all connections for leaks. 6. Push alarm reset switch when pump is running. This will silence the alarm. The pump will continue to run. 7. Reconnect the control charger and your primary pump to the AC wall outlets. The primary pump should come on and lower the water level in the sump back to the normal operating level and shut off. Both primary and backup systems are now ready for use. 8. The battery charged and charging LED s will alternate during normal charging operation. 9. Install a sump cover. A cover will prevent solid matter from falling into the sump, prevent odors, and guards against accidental injury. Battery Selection The DC emergency pump system requires a good quality, 12 volt battery to obtain maximum pumping time during a power outage. A deep-cycle, 12 volt, 105 amp-hour marine battery or larger is recommended and will provide approximately 7½ hours of continuous pumping time in a sump pump installation with 8' of head pressure. In most installations the pump runs intermittently and the battery life is extended accordingly. Batteries with top terminals are recommended for ease of installation. These batteries contain acid and proper precaution must be taken when handling. Maximum battery size 12½" Length x 7" Width x 9½" Height. There are millions of batteries manufactured each year, so it is impossible to guarantee consistent quality. A defective battery will never become fully charged and may damage the charging circuits of the Control. It is for this reason that Star offers its own line of batteries. We offer both a Water/Acid Deep-Cycle Battery which can run the pump continuously for over 7½ hours, and a Maintenance-Free AGM Battery, which will power the pump for over 3½ hours. These times are based on continuous pumping at 10 of static head. Actual times will vary depending on static head, volume of water entering the pit, and the condition of the battery. Follow these recommendations: Use a B.C.I. size 27 deep-cycle battery, 175 minute reserve capacity, or larger. Do NOT use a maintenance-free battery unless it is a Gel-filled or AGM battery. Replace your battery every 3 years. Do not let corrosion build up on the battery terminals. Do not place your battery on a concrete floor where it will discharge faster. To check specific gravity, follow the instructions on a hydrometer (not applicable for Gel or AGM batteries). PROTECT YOUR WARRANTY: Water level in batteries must be checked once a month (not applicable for Gel or AGM batteries). Carbon Monoxide Detectors Whether you have a Silent Sentry Backup Pump System, or a competitive brand, all use batteries that give off gaseous by-products when charging. Some of these by-products can produce a rotten egg odor. Also, some of these by-products can cause a CO detector to falsely activate. In order to help prevent false activation, Star Water Systems recommends moving the battery as far apart from the CO detector as possible or, if necessary, vent the battery to the exterior. Star Water Systems 1-1/2 SCH 40 PVC Pipe x 8-3/4 in Lg. Float Switch 017197 Power on Red Alarm Reset 1-1/2 SCH 40 PVC Tee 1-1/2 SCH 40 PVC Pipe x 2-1/8 in. Lg DC Pump 017198 Check Valve Asm w/rubber Coupling and Clamps NOTE: Check Valve Screws Into Primary Pump Discharge. Hand-tighten Only. Weep Hole Must Be Visible 3SDHL Primary Pump IL1004 Indicator Charging-Yellow Charged-Green Black Lead to Neg. Battery Terminal Blue Lead to Float Switch Black with Red Tracer to Pos. Battery Terminal Non-grounded Power Cord IL1009 FIGURE 3 FIGURE 4 4

provides the previous statements only as guidelines to help prevent false activation of the CO detector. In no way are they meant to supersede the instructions that accompany the detector nor do they supersede advice from the CO detector manufacturer. If the audible alarm associated with your CO detector is activated, we recommend the following actions: 1. Take immediate action for personal safety as recommended in the CO detector literature. 2. Contact the appropriate agency to determine if the CO is being produced by your furnace, water heater, or any other device which uses natural gas. 3. If you are certain that no CO is being produced, then a charging battery may be producing gaseous by-products which are causing the CO detector to activate. Contact the manufacturer and ask for recommendations as to what can be done to prevent the alarm activation. Maintenance 1. Inspect and test system for proper operations at least every 3 months. (a) Red power on indicator light should be on indicating AC power is on. (b) Unplug primary pump and the control charger from power supply. (c) Fill sump with water to the on level for the DC pump. Allow pump to run a few minutes. (d) The alarm will sound approximately 5 seconds after the pump starts to run. (e) Push alarm reset switch. The alarm will go off. (f) Pump will shut off after water level is lowered and the float drops to the off position. 2. Plug the control charger and the primary pump into the wall outlet. (a) The primary pump will come on and lower the water to the normal operating level and shut off. (b) The yellow charging light should be on. The charger is replacing the energy consumed during the test. The green light will come on after the charger has replaced the energy consumed during the test. 3. Battery should be agitated gently every 3 months. CAUTION: Battery acid is dangerous. Take proper safety precautions. Do not splash the acid. Add distilled water to battery when necessary per battery manufacturer's instructions. Troubleshooting 1. Charging and charged LED s alternate frequently. (a) This is normal. 2. DC Pump won t run. (a) Check 15 amp fuse in line from pump to switch (see fig. 5). If fuse is blown, replace with 15 amp Littelfuse type 3AG, series 311. (b) Check for proper connections. (c) Check all wire terminal points. Clean if required. 5 (d) Check for low battery. Service battery if required. 3. Pump runs but pumps very little or no water. (a) Check for low battery. Battery will recharge if Red power on light indicates power has been restored and the float switch is in the off position. (b) If immediate usage is required, remove and replace dead battery with a full recharged battery. (c) Due to varying conditions the pump may continue to run on a low battery without sufficient power to remove water. Pump will not stop running until battery is completely discharged. (d) CAUTION: Weak batteries can be recharged but may not store sufficient energy for full service. A weak recharged battery can only be detected by reduced pumping time or by checking each cell with a hydrometer. If your emergency pump system is used frequently the battery should be checked by a qualified battery dealer. 4. Pump cycles too frequently. (a) Check positions of rubber stops on float rod. (b) Adjust upper rubber float stop as required. Recommended for standard installation. 5. Float switch in on position. Pump won t run. (a) Remove pump. Check for obstruction in pump preventing impeller from rotating. 6. Pump runs, but pumps water intermittently. (a) Pump is air locking. Check flow of water incoming to sump. If water is entering the sump at a high velocity creating a turbulent condition, a mixture of air and water may cause a complete or partial air lock and reduce or stop the flow of water in the discharge pipe. (b) Baffle the incoming stream of water to reduce turbulence. Diverting water stream against wall of basin usually corrects an air lock problem. 7. Water level stays high. DC Pump continues to run. (a) Battery is low. (b) If power has been restored and water in sump remains high check primary pump. Service if required. (c) After several hours the battery will be restored to full charge. 8. Alarm sounds during battery recharge cycle. (a) Push alarm reset (max. 3 times). If condition persists, replace battery. (b) To silence alarm if alarm will not reset, unplug the charger from 115V wall outlet, then disconnect the black lead from charger on negative (-) battery post. Check battery. Replace if necessary. Reconnect and refer to Installation (step 14).

Easy Do's & Don'ts for Installing a Sump Pump 1. DO read thoroughly all installation material provided with the pump. 2. DO inspect pump for any visible damage caused by shipping. Contact dealer if pump appears to be damaged. 3. DO clean all debris from the sump. Be sure that the pump will have a hard, flat surface beneath it. DO NOT install on sand, gravel or dirt. 4. DO be sure that the sump is large enough to allow proper clearance for the level control switch(es) to operate properly. 5. DO Always Disconnect Pump From Power Source Before Handling. 6. DO always connect to a separately protected and properly grounded circuit. 7. DO NOT ever cut, splice, or damage power cord unless in a watertight junction box. 8. DO NOT carry or lift pump by its power cord. 9. DO NOT use an extension cord with a sump pump. 10. DO NOT use a discharge pipe smaller than the pump discharge. 11. DO NOT use a sump pump as a trench or excavation pump, or for pumping sewage, gasoline, or other hazardous liquids. 12. DO test pump immediately after installation to be sure that the system is working properly. 13. DO cover sump with an adequate sump cover. 14. DO review all applicable local and national codes and verify that the installation conforms to each of them. 15. DO consult manufacturer for clarifications or questions. 16. DO consider a two pump system with an alarm where an installation may become overloaded or primary pump failure would result in property damages. 17. DO consider a D.C. Backup System where a sump or dewatering pump is necessary for the prevention of property damages from flooding due to A.C. power disruptions, mechanical or electrical problems or system overloading. 18. DO inspect and test system for proper operations at least every three months. This product is warranted for one year from the date of purchase or two years from the date of manufacture, whichever occurs first. Subject to the conditions hereinafter set forth, the manufacturer will repair or replace to the original consumer, any portion of the product which proves defective due to defective materials or workmanship. To obtain warranty service, contact the dealer from whom the product was purchased. The manufacturer retains the sole right and option to determine whether to repair or replace defective equipment, parts or components. Damage due to conditions beyond the control of the manufacturer is not covered by this warranty. THIS WARRANTY WILL NOT APPLY: (a) To defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with printed instructions provided; (b) to failures resulting from abuse, accident or negligence or use of inappropriate chemicals or additives in the water; (c) to normal maintenance services and the parts used in connection with such service; (d) to units which are not installed in accordance with normal applicable local codes, ordinances and good trade practices; and (e) the unit is used for purposes other than for what it was designed and manufactured. RETURN OF WARRANTED COMPONENTS: Any item to be repaired or replaced under this warranty must be returned to the manufacturer at Kendallville, Indiana or such other place as the manufacturer may designate, freight prepaid. LIMITED WARRANTY 6 THE WARRANTY PROVIDED HEREIN IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND MAY NOT BE EXTENDED OR MODIFIED BY ANYONE. ANY IMPLIED WARRANTIES SHALL BE LIMITED TO THE PERIOD OF THE LIMITED WARRANTY AND THEREAFTER ALL SUCH IMPLIED WARRANTIES ARE DISCLAIMED AND EXCLUDED. THE MANUFACTURER SHALL NOT, UNDER ANY CIRCUMSTANCES, BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES, SUCH AS, BUT NOT LIMITED TO DAMAGE TO, OR LOSS OF, OTHER PROPERTY OR EQUIPMENT, LOSS OF PROFITS, INCONVENIENCE, OR OTHER INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY TYPE OR NATURE. THE LIABILITY OF THE MANUFACTURER SHALL NOT EXCEED THE PRICE OF THE PRODUCT UPON WHICH SUCH LIABILITY IS BASED. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some states do not allow limitations on duration of implied warranties or exclusion of incidental or consequential damages, so the above limitations may not apply to you. WARRANTY VALID IN CANADA AND MEXICO.