Laboratory Exhaust Air Terminal

Laboratory Room Controller

Rebuild/Repack Kits for Flowrite VF 599 Series 2-1/2 to 6-inch Valves

Flowrite AP 599 Series

Laboratory Room Single Duct Supply Air Terminal

TEC Actuator Package. Product and Part Numbers. Product Description. Installation Instructions Document No October 27, 2010 CAUTION:

Powers TM Controls Three-way Electro-pneumatic (EP) Valve Model 2

POWERS Controls No. 4 Pneumatic Damper Actuator

Powers Controls Powertop Two-Way Valves Normally Open

Powers Controls No. 6 Damper Actuators Tandem Mounting

Flowrite TM AP 599 Series 8-inch Pneumatic Valve Actuator

Pressure Independent Control Series

SKD62UA Series Electronic Valve Actuator, Advanced Features

Laboratory Room Single Duct Supply Air Terminal

Pressure Independent Control Series

Powers TM Controls SW 141 Differential Static Airflow Switches

SED2 Variable Frequency Drive Electronic Bypass (E-Bypass) Options

SAX Electronic Valve Actuator

Powers Controls RL 147 Positioning Relay

SED2 Variable Frequency Drives

POWERS TM CONTROLS SW 786 Selector Switch

POWERS Controls. Technical Instructions Document No P25 AP December 3, No. 6 Pneumatic Damper Actuator.

POWERS TM CONTROLS LC Pneumatic Damper Actuator

Product Description. Product Numbers. Warning/Caution Notations. Required Tools. Wiring. Prerequisites

VE VVG Series Electronic Two-way Valves Normally Closed

SED2-BT300-XX-C09 Migration Kits. Product Numbers

Flowrite 599 Series High Pressure Close-Off 2-Way Valves, 2-1/2 to 6-Inch, Flanged Iron Body, ANSI Classes 125 & 250

Flowrite 599 Series. Technical Bulletin. 1/2 to 2-Inch Valve (2-Way & 3-Way) and Actuator Assembly Selection. Document No.

UniTrak Sensor Assembly Kit Horizontal, Vertical, and Combination Sashes

Series 1000 Room Temperature Sensors, 1K Ω Platinum (375α) RTD (MBC/RBC/MEC/UC)

599 Series Zone Valves

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER

BACnet Lab and Pressurized Room Controllers with Off-board Air Modules

Powers Controls Maximum Thrust Ratings of Pneumatic Damper Actuators

599 Series Ball Valve and Actuator Assemblies Selection

Powermite 599 MT Series Terminal Unit Valve and Actuator Assembly Selection

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS

Powers TM Controls VP 656 Powermite Three-way Mixing Valves (Flared Type)

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

Flowrite EA 599 Series SQX Electronic Valve Actuator 24 Vac, 3-Position Control

Powermite 599 MT Series Terminal Unit Valve and Actuator Assembly Selection

Powermite 599 MT Series SQS Electronic Valve Actuator, 24 Vac, Floating Control (3-position)

Flowrite 599 Series Two-Way Valves, 1/2 to 2- inch Bronze Body, ANSI 250

MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS

599 Series Ball Valve and Actuator Assemblies Selection

599 Series Zone Valve Bodies:

Powermite 599 Series MZ Series SSB Electronic Valve Actuator 24 Vac Proportional Control

POWERS CONTROL RC 195 Multiple Input Receiver- Controller

Powermite 599 Series MZ Series SSB Electronic Valve Actuator 24 Vac Floating Control

SKP Series SKP15 U.. Gas Valve Actuator with Safety Shutoff Function

Ball Valve Bracket Kit

Flowrite EA 599 Series SKD Electronic Valve Actuator 24 Vac 3-Position (Floating) Control

Flowrite 599 Series Three-Way Valves 1/2 to 2-inch Bronze Body

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

Flowrite 599 Series Two-Way Valves, 1/2 to 2- inch Bronze Body, ANSI 250

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Floating Control

Powers Controls No. 6 Pneumatic Damper Actuator

Flowrite 599 Series Three-Way Valves 1/2 to 2-inch Bronze Body

SAX Electronic Valve Actuator

Technical Instructions Document No EA GQD May 6, OpenAir GQD Series. Spring Return, 20 lb-in (2 Nm), Rotary Electronic Damper Actuators

Powers Controls No. 4 Pneumatic Damper Actuator

Powers Controls TT 184 Temperature Transmitters

Pressure Independent Control Series 2-Way Valves and Electronic Valve Actuators

OpenAir Electric Damper Actuators GBB/GIB Series NSR Rotary 24 Vac - Modulating Control

599 Series 6-Way Ball Valves

OpenAir GBB/GIB Series Electronic Damper Actuators Non-Spring Return, 24 Vac, Modulating Control

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return, 24 Vac Floating Control, Rotary

OpenAir GBB/GIB Series Electronic Damper Actuators Non-Spring Return, 24 Vac, Modulating Control

OpenAir Electronic Damper Actuators GLB Series Enhanced Non-spring Return Rotary

ACCUVALVE MODEL AVC6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVC6000 AVC6 - - DWG. NO: REVISION: REV. DATE:

SCC Inc. BRx Series. Technical Instructions. Document No. CPBK-2000 September 15, BR-AS Bracket Assemblies for use with SQM Actuators

Room Temperature Sensors Series to 20 ma

SAV Electronic Valve Actuator

SQM5 Reversing Actuator with Analog Input Signal

SCC Inc. FLMTR Series. Installation Instructions Document No. LV February 21, KT-BMK-PLC Gas Flow Meter Kits for Flow Totalization

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

ACCESSORIES & OPTIONS FOR VENTURI AND VENTURI FX VALVES

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

MODEL 8630-CRC-S, 8630-CRC-P PRESSURA CLEAN ROOM PRESSURE CONTROLLER

Ball Valve Bracket Kit

Flowrite EA 599 Series SKB/C Electronic Valve Actuator 24 Vac, 3-Position (Floating) Control

Flowrite VF 599 Series Three-Way Valves 1/2 to 2-inch Bronze Body

OpenAir Electric Damper Actuator GDE/GLB Series Non-spring Return Rotary 24 Vac 3-position Control

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

VOG Series VOG15.01xU1 Oil Safety Shut-off Valves with Proof of Closure (POC)

Differential pressure switch for monitoring air pressure in HVAC systems.

Flowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control

ACCUVALVE MODEL AVT6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVT6000 AVT6 - - DWG. NO: REVISION: REV. DATE:

University of Delaware

The IAQ50 Air Damper/Monitor Installation and Maintenance Manual

Transcription:

Document No. 546-00335 Laboratory Exhaust Air Terminal Product Description The Laboratory Exhaust Terminal (LGE) is a onepiece flow control device used to vary airflow through an exhaust duct. See Figure 1 and Figure 2. The terminal consists of a duct section, flow sensor, and a damper blade. NOTE: The terminal s 90 damper does not have a gasket seal. Orifice plate SP300 Galvanized Construction: 1/2-inch (1.276 m) zinc plated shaft Orifice plate or SP300 airflow measurement sensor Product Numbers Contact your representative for detailed parts information. Warning Notation WARNING Personal injury/loss of life may occur if you do not follow a procedure as specified. Electronic Actuation Figure 1. Slip Ends Exhaust Terminal. Control packages including an Electronic Actuator assembly with mounting bracket, and a differential pressure transmitter (optional). These parts are included in an enclosure that is factory-mounted to the outside of the terminal. Pneumatic Actuation Figure 2. Flanged Ends Exhaust Terminal. Options Sizes 4", 6", 7, 8", 9, 10", 11, 12", 14", 16", 18 Galvanized/90, without seal; 316L stainless steel/90, without seal Slip or flange end fittings 316L Stainless steel and Teflon coated construction: Solid stainless steel shaft on Teflon bearings Control packages including one or all of the following: Analog Output Pneumatic (AO P) Transducers, No. 3 pneumatic actuator, and one differential pressure transmitter (optional). These parts can be included in an optional enclosure that is factory-mounted to the outside of the terminal. Required Tools Small flat blade screwdriver 3/8-inch open end wrench Needle nose pliers Duct tape Sealant Sheet metal screws 1/4-inch poly tubing Item Number 546-00335, Rev. EA Page 1 of 5

Expected Installation Time 30 minutes Prerequisites Terminal ductwork free of debris Construction filters in place One duct diameter of rigid straight ductwork upstream of terminal. See Figure 3. Air lines installed (for pneumatic applications) Exhaust ductwork installed NOTE: Terminals should be located so that they do not come in contact with rigid conduit, sprinkler piping, Greenfield metal covering, or rigid pneumatic tubing. Do not install terminals tight against concrete slabs or columns because vibrations are amplified through these structures. Also, allow clearance for service access to controls. Instructions Installation instructions for the LGEs are presented in the following two sections: 1. Section 1 applies to mounting the terminal unit. 2. Section 2 applies to actuation. Section 1 Mounting Do not carry the terminal by the orifice sensor. Terminal measurements are included in Table 1. 2. Connect the exhaust ductwork to the exhaust terminal s inlet collar using the accepted trade practice of welding or bolting the exhaust terminal to the ductwork. 3. Connect the exhaust ductwork to the exhaust terminal s outlet collar using the accepted trade practice of welding or bolting the exhaust terminal to the ductwork. 4. Seal all ductwork and check that the exhaust duct connections are airtight. Figure 3. Exhaust Terminal Properly Installed after an Elbow Duct Section. NOTE: Always mount the equipment enclosure on the side of the duct (vertically) (Figure 4). Mounting the equipment enclosure on the top or bottom of the duct (horizontally) will adversely affect the measurement accuracy. 1. Move the terminal to the installation area. Remove the terminal from the shipping package. Figure 4. FHET Installed Properly. Page 2 of 5

Duct Size Length (L) Inches (mm) +0.06 (1.5) Table 1. LGE Dimensions by Unit Size. Slip End Outside Diameter (OD) or Flange End Inside Diameter (ID) Inches (mm) Flange Bolt Hole Circle Size Inches (mm) 4 16.00 (406.4) 3.88 (98.6) 5.25 (133.4) 6 16.00 (406.4) 5.88 (149.4) 7.25 (184.2) 7 16.00 (406.4) 6.88 (174.8) 8.25 (209.6) 8 16.00 (406.4) 7.88 (200.2) 9.25 (234.95) 9 19.50 (495.3) 8.88 (225.6) 10.25 (260.4) 10 19.50 (495.3) 9.88 (251.0) 11.25 (285.8) 11 20.50 (520.7) 11.88 (301.8) 13.25 (336.6) 12 20.50 (520.7) 11.88 (301.8) 13.25 (336.6) 14 23.00 (584.2) 13.88 (352.6) 15.75 (400.1) 16 25.00 (635.0) 15.88 (403.4) 17.75 (450.9) 18 25.001 (635.0) 17.88 (454.2) 19.75 (501.7) 1. Provide a minimum of 1 duct diameters of straight rigid duct directly upstream. 2. Flanged connection is 1.0 (25.4 mm) for 4 through 10 sizes. OD = OD + 2.0 (50.8 mm). Bolt hole quantity = 6, Bolt hole size = 0.375. 3. Flanged connection is 1.5 (38.1 mm) for 11 through 16 sizes. OD = OD + 3.0 (76.2 mm). Bolt hole quantity = 8, Bolt hole size = 0.4375. Section 2 Actuation For application specific actuator wiring, reference the appropriate controller installation instructions. For actuator wiring, reference the appropriate actuator Technical Instructions. Field Panels and Unitary Controllers (UCs) NOTE: For field panels and UCs, the AO P Transducer used in these steps is P/N 545-113. Tubing Connections Several pneumatic connections must be made from the field panel or UC to the terminal box to operate the AO-P Transducer and pneumatic damper actuator. For damper, actuator and valve controls mounted inside the controls enclosure. Connect the 1/4-inch poly tubing from the 20 to 30 psi supply line to the port labeled Supply Air 20 30 psi on the side of the controls enclosure (Figure 5). Figure 5. Exhaust Terminal Pneumatic Piping Connections. Wiring Connections Several electrical connections must be made from the field panel or UC to the terminal to operate the AO-P Transducer and the differential pressure transmitter. 3. Connect a two-conductor 20 AWG cable to the Field Panel s 0 to 10V output or UC s universal output. Connect it to the AO P Transducer connected to the exhaust damper or through the wiring bushing/knockout on the terminal enclosure (Figure 5) to the AO P Transducer inside the enclosure. 4. The wire bushing can be removed and a standard 1/2-inch conduit knockout fitting may be installed. Connect the cable to the AO P Transducer (Figure 6). Page 3 of 5

Figure 6. AO-P Transducer Wiring Connections. Figure 7. Differential Pressure Transmitter Wiring Connections. 5. Connect a two-conductor 20 AWG cable to the field panel s 4 to 20 ma input or UC s universal input. Connect it to the differential pressure transmitter or through the wiring bushing/knockout on the controls enclosure to the differential pressure transmitter inside the enclosure. Connect the cable to the differential pressure transmitter (Figure 7). Fume Hood Controllers (FHCs) Figure 8. FHET Pneumatic Piping Connection. Wiring the AO-P Module and Differential Pressure Transmitter to the Fume Hood Controller Board. 1. Remove the equipment enclosure cover by loosening the quick release butterfly fasteners. The butterfly fasteners will remain attached to the cover. 2. With the equipment enclosure cover removed, locate the Lab AO-P module and the differential pressure transmitter. (Figure 9). Provision of the 18 to 30 psi Supply Air Connection One supply air connection must be made to the FHET to operate the pneumatic damper. 1. Use 1/4-inch OD poly tubing for an 18 to 30 psi supply air line to the FHET equipment enclosure. 2. Connect the supply air line to the barbed supply inlet port on the side of the equipment enclosure (See Figure 8). Figure 9. Equipment Locations. Page 4 of 5

3. Connect a three conductor 20 AWG cable for the Lab AO-P Module through the wiring bushing/knockout. (Figure 9). If desired, the wiring bushing can be removed and a standard 1/2-inch conduit fitting may be installed in its place. See Figure 10 for the wiring connections to the Lab AO-P Module from the Fume Hood Controller Board. Figure 10. AO-P Module Wiring Connections. 4. Connect a two conductor 20 AWG cable to the Fume Hood Controller for the differential pressure transmitter. See Figure 11 for wiring connections to the differential pressure transmitter from the Fume Hood Controller Board. The installation is now complete. Figure 11. Differential Pressure Transmitter Wiring Connections Information in this document is based on specifications believed correct at the time of publication. The right is reserved to make changes as design improvements are introduced. APOGEE and Insight are registered trademarks of Other product or company names mentioned herein may be the trademarks of their respective owners. 2011 Building Technologies Division 1000 Deerfield Parkway Buffalo Grove, IL 60089-4513 U.S.A Your feedback is important to us. If you have comments about this document, please send them to SBT_technical.editor.us.sbt@siemens.com. Document No.546-00335 Printed in the USA Page 5 of 5