Access Doors. Sandwich Access Doors. Quick and Easy

Similar documents
Access Doors. Sandwich Access Doors Quick and Easy. Industries, Inc. ACCESS DOORS

Mechanical System Hanger

Cable Hanging System. Labor-saving, versatile means for hanging static load HVAC Systems. U.S. Patent No. 7,222,824

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

Straight-Bore Clutch LSCC-32, 44, 54

Through-Shaft Clutch-Brake LSCB-32HT, LSCB-32HT, LSCB-44, LSCB-44HT, LSCB-54HT FORM NO. L D-0606 MEX (55) QRO (442)

WIRING DIAGRAMS FOR BRIDGE CONTROL PANELS

FCB-450, LCB-600, MCB-800

Grinnell Grooved Fire Protection Products Grooved Fittings

37SCENE 46SCENE 79SCENE

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704

DIGIGAUGE P R E S S U R E D I S P L A Y S Y S T E M I N S T R U C T I O N M A N U A L

OPERATING INSTRUCTIONS AND PARTS LIST BRIDGE DRIVE GEAR CASE

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

Transmission Guardian

MaxLite StaxMax LED Flood Lights

Illumifalls Patio Pond

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

Rear Sway Bar for XC90 ( ) 2.5T and T6 ipd mounting kit SBK42

Single-Position Detent Clutch DC Series. (i) MTY (81) MEX (55) QRO (442)

GRINNELL Model B302 and Model BN302 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.

OPERATING INSTRUCTIONS AND PARTS LIST

RV-10 Center Arm Rest Console

DAP-625S and DAP-875S

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

EXHAUST FAN FLOW METER

Level Alert Model Multi-Switch Liquid Level Sensor. Assembly and Installation Instructions

Installation Instructions **THIS RAIL MOUNTING KIT USES 11 BOLTS**

CSA CERTIFIED Conforms to UL 507

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

ASSEMBLY & PACKING INSTRUCTIONS FOR THE MULTICHAIR 3000

Pressurized Pond Filter Up to 850 gallons

Users Guide for Ac-sync

INSTALL GUIDE Dodge/RAM 5.7L HEMI

3M-MaticTM. Tape Edge Fold Kit. Instructions and Parts List. For Use On: AccuGlide TM STD Upper and lower Taping Heads. Purpose of Attachment

Carbon Steel Nipples

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

INSTALLATION INSTRUCTIONS

SUPREME FEEDER MANUAL NO REV A / 09/02/ DOOR HOG FEEDER ASSEMBLY INSTRUCTIONS

AIR CHAMP PRODUCTS. User Manual. Sheave & Pilot Mount Clutch-Brake Model BCB-275 FORM NO. L F-0414 FORM NO. L F-0414

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

Terms and Conditions

Installation Instructions Soft Top Replacement Hardware, Wrangler

INSTALLATION, INSTRUCTION AND SERVICE MANUAL

Exhaust Fan Flow Meter. Operation Manual. The ENERGY CONSERVATORY DIAGNOSTIC TOOLS TO MEASURE BUILDING PERFORMANCE

Cleaning & Sanitizing Instructions

Installation Instructions

DWS404 DWS524 DWS654 DWS684 DWS694. DWS SERIES INSTALLATION/OWNER'S MANUAL Car Audio Speakers

Installation Instructions

MEX (55) QRO (442) Web Controls

5 Gallon Tall Tea Dispenser 3 Gallon Tall Tea Dispenser TALL TEA DISPENSERS. Cleaning & Sanitizing Instructions

HR-20P Pneumatically Controlled Pressure Regulator

Natural Fiber Planter Fountain

Installation Instructions

Installation and Maintenance Instructions 44TA Liquid Level Float Switch

EASY CONNECT CRANE KIT Festoon Conductor Systems

Installation Instructions

Container Fountain Kit with LED Light

Woolich Racing. Bike Harness Installation Instructions Suzuki Harness Type 4a GSX1300R (Hayabusa)

Installation Instructions

60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60

Installation Instructions

WEB CONTROL PRODUCTS

GLYCOL SYSTEM MONITOR (GSM)

Installing the Boom Mount ET 350 Monitor (Model ET 350R)

Flange Spreader Parts and Operating Manual

FIRE SPRINKLER EQUIPMENT SUBMITTAL

Installation Instructions and Service Manual

Jeep JK Wrangler Modular HD Front Winch Bumper

DeZURIK KUL KNIFE GATE VALVES

AXS609 AXS612 AXS514 AXS SERIES. INSTALLATION/OWNER'S MANUAL Car Audio

BIN & SEN Annular Pitot Tube Flow Meter. Form: 10-PTT-UM (December 2012) Installation & Operation Manual

DODGE CUMMINS Arctic-Heat Grid Relocation Kit

Installation, Operating & Maintenance Manual 30P Planetary Winch

ASSEMBLY OF TROLLEY TO HOIST

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

Woolich Racing. Bike Harness Installation Instructions Hayabusa Gen 2 (08+)

STC2 Car Kit. Installation Guide

SUNTURA SOLAR TRACKER

½ DODGE CUMMINS OEM BYPASS LIFT PUMP KIT Installation Instructions Part #

Installation Instructions. Fog Lights. The lamps get very hot when they have been in use. Do not touch them as they may cause burns.

CEAT SPECIALTY TIRES INC. LIMITED WARRANTY POLICY For AGRICULTURE BIAS TIRES

Installation Instructions

AEROMOTIVE Part # Subaru STI Fuel Rails INSTALLATION INSTRUCTIONS

COMMAND SERIES 410-L T L T T T L06R RS PRODUCT MANUAL

Z-Tech Severe Chemical Service Valves We Put Control Where You Need It.

PowerMax Diesel Upgrade For Cummins Engines

USER MANUAL. NEMA 48C Flange Mounted, Enclosed, Clutch Brake. FMCBE Model 500 FORM NO. L A (i)

DC Distribution Panel User Guide # S

OWNER S MANUAL Z SERIES TRACKS. Rev. 355_05

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Single Post Caliper Brake VC500

3M Cross-Connect Cabinets 4220SVC and 4220SVE Tall Skirt Installation Guide

Window Thermometer models / / 00423

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

AutoSparge. Lauter Tun Level Control. Operation, Assembly & Maintenance Manual

Installation Instructions

3M Electrical Markets Division. Rubber, Mastic and Specialty Tapes Application Guide. Choose the. Right Tape. for your. Electrical Project

Submersible Waterfall Pump 1200 Gallons Per Hour

Transcription:

D U C T M A T E Access Doors Sandwich Access Doors Quick and Easy Advanced Pressure Vessel Design Insulated, Uninsulated, and Specialty Metals No Measuring (Self-Adhesive Template Provided) Effortless Opening and Closing (No Tools Required) Shape Provides a More Effective Access Area No Frame to Install

Rectangular Hi-Temp Access door for rectangular duct. To provide easy access into air ducts and units. The door was developed to provide a solid, well-insulated, leakproof door that is simple to install. Insulated or uninsulated Smooth interior finish on insulated doors Tested to 20 W.G. with no leakage noted Tested to negative 10 W.G. with no leakage noted Please specify when ordering doors for negative pressure applications as gasket is placed to the outside panel Insulated doors are recommended for negative pressure applications The insulated Sandwich Access Door consists of three layers of precision stamped steel. The inside panel consists of two layers of metal which are spot welded together along the rim encapsulating high density fiberglass insulation with Ecose Technology UL classified FHC25/50. Uninsulated doors have similar construction without the backing plate and insulation. NOTE: The 24 x 18 door consists of only two layers of precision stamped steel. A polyester foam pad installed between the inner and outer door panels provides insulation. (The 24 x18 door is not available with high density fiberglass insulation). 200 F. The gasket is bonded to the inside panel of the access door to insure consistent installations. d. Knobs Red polypropylene molded knobs have threaded metal inserts to eliminate thread stripping. Knobs are easily turned by hand. Knobs are UL94HB listed. Access door for round or rectangular duct. To provide easy access into grease duct or high-temp duct systems. The door was developed to provide a solid, leak resistant door that is simple to install. High-Temp access door application approval resides with the authority having jurisdiction. Available in all sizes of standard flat and round duct access doors 16 gauge black iron backing plate The Hi-Temp Access Door consists of two layers of precision stamped, hot-dipped galvanized steel and one 16 gauge black iron backing plate. The backing plate is spot welded to the inside panel. For Hi-Temperature application fiberglass rope (1000 F max) is permanently bonded to the outside panel of the access door to eliminate leakage. For Grease Duct application, Ceramic Fiber Gasket (2300 F max -- meets NFPA 96 standards) is permanently bonded to the outside panel of the access door to eliminate leakage. d. Wing Nuts Zinc coated wing nuts are easily turned by hand.

Circular Clean-Out Clean-Out Access door for duct cleaning. Uninsulated access door for duct cleaning. To provide easy access into air ducts and units. The door was developed to provide a solid, leakproof door that is simple to install. To provide easy access into air ducts and units. Insulated or Uninsulated Our lowest cost door The Circular Access door consists of two layers of precision stamped, hot-dipped galvanized steel. 200 F. The gasket is permanently bonded to outside panel of the access door to eliminate leakage. Zinc plated conical springs are installed over the bolts, between the inner and outer door, to facilitate opening d. Wing Nuts Zinc coated wing nuts are easily turned by hand without tools. f. Insulation A polyester foam pad installed between the inner and outer panel. The Clean-Out Access door consists of two layers of precision stamped, hot-dipped galvanized steel. 200 F. The gasket is bonded to the inside of the door to insure consistent installations. d. Wing Nuts Zinc coated wing nuts are easily turned by hand.

Round Duct Observation Access door for round ducts. To provide easy access into air ducts and units. The door was developed to provide a solid, leak proof door that is simple to install. Insulated or uninsulated Smooth interior finish on insulated doors Tested to 20 W.G. with no leakage noted Tested to negative 10 W.G. with no leakage noted Please specify when ordering doors for negative pressure applications as gasket is placed to the outside panel Insulated doors are recommended for negative pressure applications The insulated Round Duct Access Door consists of three layers of precision stamped steel. The inside panel consists of two layers of metal which are spotwelded together along the rim, en capsulating high density fiberglass insulation with Ecose Technology UL classified FHC 25/50 Uninsulated doors have similar construction without the backing plate and insulation. NOTE: The 24 x 18 access door consists of only two layers of pre cision stamped steel. A polyester foam pad installed between the inner and outer door panels provides insulation. (The 24 x 18 door is not available with high density fiberglass insulation). 200 F. The gasket is bonded to the inside of the door to insure consistent installations. d. Knobs Red polypropylene molded knobs have threaded metal inserts to eliminate thread stripping. Knobs are easily turned by hand. Knobs are UL94HB listed. Access door which allows inspection of the inside of the duct without door removal. To provide easy access into air ducts and unit and allow for viewing the inside of the duct. The door was developed to provide a solid, leakproof door that is simple to install. 4 x 2-5/8 viewport Safety glass used for window Tested to 10 W.G. The Observation Access Door consists of two layers of precision stamped, hot-dipped galvanized steel. 200 F. The gasket is permanently bonded to the inside panel to eliminate leakage. d. Knobs Red polypropylene molded knobs have threaded metal inserts to eliminate thread stripping. Knobs are easily turned by hand. Knobs are UL94HB listed. f. Glass Safety glass (1/4 ) is permanently sealed with silicone. g. Clips Hot-dipped galvanized steel clips mechanically fasten the safety glass in place. h. Template

PACKAGING INFORMATION Rectangular Size Part No. Gauge # Per Lbs Per **8 x 4 D*84GA 22 10 12 10 x 6 D*106GA 22 10 25 12 x 8 D*128GA 22 10 35 **16 x 12 D*1612GA 20 5 31 18 x 14 D*1814GA 20 5 45 **24 x 18 D*2418GA 18 3 27 * Available in Insulated (I) or Uninsulated (U), please specify ** Oval Shaped Round Duct Door Size Duct Diameter Part Number 5-6 DR*846GA 7-9 DR*849GA 10-11 DR*8411GA 12-14 DR*8414GA 8 x 4 12 lbs. per carton 12 x 8 35 lbs. per carton 16 x 12 20 Gauge 5 per carton 31 lbs. per carton 24 x 18 available in 2 panel only 18 Gauge 2 per carton 25 lbs. per carton 10-11 12-14 21-22 23-24 25-28 37-60 37-40 41-44 45-48 49-52 53-56 57-62 63-144 * Available in Insulated (I) or Uninsulated (U), please specify Round Duct Hi - Temp 8 x 4 12 lbs. per carton DR*12811GA DR*12814GA DR*12816GA DR*12818GA DR*12820GA DR*161216GA DR*161218GA DR*161220GA DR*161222GA DR*161224GA DR*161228GA DR*161232GA DR*161236GA DR*241832GA DR*241836GA DR*241840GA DR*241844GA DR*241848GA DR*241852GA DR*241856GA DR*241862GA Door Size Duct Diameter Part Number 5-6 DR846*GA 7-9 DR849*GA 10-11 DR8411*GA 12-14 DR8414*GA 12 x 8 35 lbs. per carton 16 x 12 20 Gauge 5 per carton 31 lbs. per carton 24 x 18 18 Gauge 2 per carton 25 lbs. per carton 10-11 12-14 21-22 23-24 25-28 37-60 37-40 41-44 45-48 49-52 53-56 57-62 63-144 * F1 for doors rated to 1000 F. F2 for doors rated to 2300 F. DR12811*GA DR12814*GA DR12816*GA DR12818*GA DR12820*GA DR161216*GA DR161218*GA DR161220*GA DR161222*GA DR161224*GA DR161228*GA DR161232*GA DR161236*GA DR241832*GA DR241836*GA DR241840*GA DR241844*GA DR241848*GA DR241852*GA DR241856*GA DR241862*GA Rectangular Duct Hi-Temp Size Part No. Gauge No. Per Lbs. Per 8 x 4 **D84*GA 22 10 12 10 x 6 D106*GA 22 10 32 12 x 8 D128*GA 22 10 50 16 x 12 **D1612*GA 20 5 31 18 x 14 D1814*GA 20 5 64 **24 x 18 D2418*GA 18 3 57 * F1 for doors rated to 1000 F. F2 for doors rated to 2300 F. ** Oval Shaped Clean-Out Size Part No. Gauge No. Per Lbs. Per 10 x 6 DC106GA 24 10 15 12 x 8 DC128GA 24 10 23 Circular Clean-Out Size Part No. Gauge No. Per Lbs. Per 8 DC*8GA 24 10 12 10 DC*10GA 24 10 17 12 DC*12GA 22 10 26 * Available in Insulated (I) or Uninsulated (U), please specify Observation Size Part No. Gauge No. Per Lbs. Per 10 x 6 DO106GA 22 10 25 Note: For information on our larger 16 x 12 Observation Door see our stand-alone literature. INSTALLATION INSTRUCTIONS 1. Peel backing off template and apply to duct in desired location. 2. Opening can be cut with hand-held plasma cutter or by conventional methods. 3. Insert door into opening at an angle and tighten knobs. 4. Do not overtighten knobs or wing nuts.

LIMITED PRODUCT WARRANTY Ductmate warrants that Sandwich Access Doors, when properly installed and maintained, will be free from defects in material and workmanship, and will comply with all written specifications made by Ductmate at the time of sale. Ductmate s warranty shall run for a period of one year from the date of manufacture. Warranty Limitation The warranty stated above is in lieu of all other warranties, express or implied, including but not limited to the implied warranties of MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Although Ductmate may have suggested the product, or provided written or oral advice to the Purchaser, it is the Purchaser s responsibility to test and determine the suitability of Sandwich Access Doors, for the intended use and purpose, and Purchaser and/or its customer assumes all risk and liability whatsoever regarding such suitability. Limitation of Liability In the event of a breach of the above warranty, Ductmate s sole obligation, and Purchaser s sole and exclusive remedy, shall be, at Ductmate s option, repair or replacement of any defective products, or refund of an applicable portion of the purchase price. Ductmate shall have no liability for costs of removal or reinstallation of the product. The Purchaser agrees that no other remedy, including but not limited to loss of profits, loss sales, injury to person or property, or any other special, incidental or consequential damages, shall be available to the Purchaser for any claim arising out of this Agreement, regardless of whether such claim is made in contract or in tort, including strict liability in tort. In no event will Ductmate be obligated to pay damages to the Purchaser in any amount exceeding the purchase price that the Purchaser paid to Ductmate for the allegedly defective product. Listed 88VF Fittings for Hood and Duct Penetration Grease Duct Access Door Distributed By: Charleroi, PA 210 Fifth Street Charleroi, PA 15022 724-258-0500 Lodi, CA 810 S. Cluff Avenue Lodi, CA 95240-9141 209-333-4680 10% This spec data is printed on paper that meets the Certified Fiber Sourcing requirements of the SFI program. Ductmate Is A Proud Member Of The Following Organizations: Additional Manufacturing and Warehousing in Monongahela, PA and Tulsa, OK 1-800-245-3188 www.ductmate.com Copyright Ductmate Industries, Inc. All rights reserved. 61-05/17