SYSTIMAX GS3 and 1100GS6 Evolve Modular Panel Instructions

Similar documents
PATCHMAX GS3, GS6 and PowerSUM Modular Panels

UNP-U-Type Universal Panel Instructions

UNPWM-U-Type Universal Wall Mount Patch Panel Instructions

SYSTIMAX 360 FTP Evolve Panel Instructions

SYSTIMAX 360 ipatch G2 High Density Sliding Fiber Shelf Instructions

ipatch Ready Upgrade Kit for SYSTIMAX 360 Fiber Shelves Instructions

SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions

UNP610-WM-12P Modular Jack Panel Installation

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, MPO Distribution Panel Instructions

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, LC InstaPATCH Distribution Panel Instructions

SYSTIMAX G2 4U Fixed Rear Access Combination Shelf Instructions

8-Position Cat5E EMT Shielded Slim-Line Modular Plug

Application Specification Circular Plastic Connector (CPC) Series 45 System 05 AUG 14 Rev D

SYSTIMAX SMB-4-3/4, SMB-8-1/2 Shelf-Mounted Cable Bracket Kits and 1000G2-XCPB Expanded Cable Protector Kit

Replacing the Gear Drive Motor Assembly and GFCI Module for Operation with the Chain Drive Motor Assembly

Position Cat6 Shielded. Modular Plug Connectors. Application Specification

FIBER CONNECTOR SAFETY WARNINGS

INSTALLATION GUIDE. LANmark EVO Series Snap-in Connector S-FTP STP

E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices.

How to remove and replace the Foonf/Fllo fabric

SYSTIMAX Solutions. Asia-Pacific Ordering Guide (03/14)

Fiber Connector Shelf (CCS)

FCategory 5e 110 Wiring

SCION FR-S FOG LIGHTS

JBS-100-A, A6 SINGLE ENTRY POWER CONNECTION WITH JUNCTION BOX INSTALLATION INSTRUCTIONS

S6 BATTERY REPLACEMENT

GENUINE PARTS INSTALLATION INSTRUCTIONS

GENUINE PARTS INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Engine 3 Installation

Panduit PreConfigured ZDF48-RA Industrial Distribution Frame (IDF) Installation Instructions

Voice/Data/ Video Tools

Mini-OTE 400. Mini-OTE 400. Content 1 General 1.1 General product information 1.2 Cable types 1.3 Symbols in this guide.

JBS-100-STB Single Entry Power Connection with Junction Box Installation Instructions

JBM-100-STB NEMA 4X-rated connection kit Installation Instructions

Opticom Rack Mount Fiber Enclosures

2015 Mustang Lightbar (All Models) CDC#

Pretium Wall-Mountable Housing (PWH-02P/-04P/- 06P/-12P and FZB-02P-JB)

SPEED CONTROL 4 AND 6 CYL. JEEP WRANGLER. Read entire instructions thoroughly before starting. INSTALLATION INSTRUCTIONS TOOLS REQUIRED:

Replacing the T320 Cooling System Components. Replacing a T320 Fan Tray. Removing a T320 Front Fan Tray

GENUINE PARTS INSTALLATION INSTRUCTIONS

Top Down Rollstar Shade Installation Instructions

GENUINE PARTS INSTALLATION INSTRUCTIONS

DS1 Plug-In Digital Signal Cross-Connect (PIX-DSX-1) 19-Inch Shelf Kit Installation Instructions

TOYOTA VENZA 2009 TRAILER WIRE HARNESS Procedure

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

2M Series Contacts and Tools

8400 Series Fiber Distribution System

Instructions for Use - Opt-X Ultra Enclosure Directives Enceintes Opt-X Ultra MC Instrucciones de Uso Caja Opt-X Ultra MR

1989 Jeep Cherokee. STEERING COLUMN' '1989 STEERING Jeep Steering Columns STEERING COLUMN STEERING Jeep Steering Columns

Shaver Industries. Assembly Instructions Vertical Vinyl Curtain Door DT2 Wire Rope Replacement

CommScope MULTILAYERED 289-TYPE INSTALLATION INSTRUCTIONS

Data sheet E-DAT Industry RJ45 field plug black Cat.6 Class E A

Job Sheet 6 Installing the Combiner Box

Environmental Distribution Center (EDC-06P-NH)

Bel Stewart Connector

TOYOTA VENZA 2009 TRAILER WIRE HARNESS Procedure

OFE-CLS-Type Outside Plant (OSP) Fiber Optic Closures Instructions

Data sheet C6 A modul 24 port 180 M 1RU stainless steel

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF and ZDF

Data sheet E-DAT modul 24x8(8) 1RU patch panel Cat.6 A, stainless steel

Universal Splice Tray Installation Instructions

XChange Seat Service and Maintenance Guide

* * APPLICABLE MODELS: 2014 > Mazda 3

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks

SCION xd INTERIOR LIGHTING UPGRADE Preparation

GENUINE PARTS INSTALLATION INSTRUCTIONS

Customer Owned Copper Outside Plant Guidelines

Toyota Prius Interior Light Upgrade

CASS Interface System Parts Section 1

GENUINE PARTS INSTALLATION INSTRUCTIONS

Carousel Unit User Manual Replacing the Check Stand Motor

* * APPLICABLE MODELS: 2014 > Mazda 6

HP Modular Cooling System 200/100 Options Installation Guide

Rollstar Shade Installation Instructions

* * APPLICABLE MODELS: 2017 > CX-5

GENUINE PARTS INSTALLATION INSTRUCTIONS

Fiber optic splice closure

ARB UTILITY MANAGEMENT SYSTEMS WATER ELECTRIC GAS. E-Coder)R900i Quick Install Guide. E-Coder)R900i QUICK INSTALL GUIDE

Installation Guide. Kennedy Technology Group, Inc.

FIST-GMS2. FIST Generic Mixed Shelf MK2. Contents. 1 Introduction. 5 Termination of the pigtails. 2 General. 6 Splicing + fiber storage

Data sheet E-DAT modul Cat.6 A 8(8) jack, T568A

How to Replace a Switch

HP BladeSystem c7000 Carrier-Grade Options Installation Guide

INSTALL INSTRUCTIONS DC C-EV. Installation Instructions: DC C-EV.

INSTALLATION INSTRUCTIONS

Fiber Splice Panel Rack Mount User Manual

TOOLS AND TESTERS TERA 10G 6A F/UTP 10G 6A UTP. System 6 UTP. Premium 5e F/UTP. Premium 5e UTP. Fibre Cable Assemblies, Connectors and Cable

WARNING. Important Notice

INSTALLATION INSTRUCTIONS

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

Safe-T-element Installation Instructions

GENUINE PARTS INSTALLATION INSTRUCTIONS

Installation Instructions Supertop NX Twill

GENUINE PARTS INSTALLATION INSTRUCTIONS

Outlets terminate all shielded and shielded cable constructions AWG ( mm) size conductors.

U L T I M A T E R A D A R / L A S E R D E F E N S E S Y S T E M

HEADLAMP ASSEMBLY. Service and Wiring Instructions with Diagrams. CAUTION Read this document before installing the snowplow.

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

* * APPLICABLE MODELS: 2016 > CX-3

Transcription:

860584440 Issue 1, February 2015 SYSTIMAX 360 1100GS3 and 1100GS6 Evolve Modular Panel Instructions General The SYSTIMAX 360 1100GS3 (Cat 6) and 1100GS6 (Cat 6A) Evolve modular panels exceed ISO and TIA Performance Category standards. The performance category is identified by the color of the jacks. Jacks with gray jack housings are Category 6A (GS6) and jacks with black jack housings are Category 6 (GS3). The SYSTIMAX 360 1100GS3 (Cat 6) and 1100GS6 (Cat 6A) Evolve modular panels and can be used for EIA-T568A or EIA-T568B wiring applications and are available in 24-port and 48-port flat and angled versions. SYSTIMAX 360 InstaPATCH fiber modules can be used in the 1100GS 24-port and 48-port flat panels when the separately orderable Evolve fiber bezels, rear cable management bar, and front cable trough are utilized. The 1100GS Evolve panels are available ipatch ready. For instructions on using panels in an ipatch application, see 860516491 ipatch Upgrade Module Instructions for SYSTIMAX 360 Panels. Panel kits are available unpopulated for use with separately ordered modules. Ordering information for modular panels is listed below: 360 GS3 Modular Panels 360 GS6 Modular Panels Material ID Description Material ID Description 760152561 1100GS3 Evolve 24-port flat panel 760152587 1100GS6 Evolve 24-port flat panel 760152579 1100GS3 Evolve 48-port flat panel 760152595 1100GS6 Evolve 48-port flat panel 760151308 1100GS3 Evolve 24-port angled panel 760151324 1100GS6 Evolve 24-port angled panel 760151753 1100GS3 Evolve 48-port angled panel 760151779 1100GS6 Evolve 48-port angled panel Ordering information for panel kits is listed below: 360 Flat Panel Kits* 360 Angled Panel Kits* Material ID Description Material ID Description 760155739 1100GS Evolve 24-port flat panel kit 760152785 1100GS Evolve 24-port angled panel kit 760155747 1100GS Evolve 48-port flat panel kit 760152793 1100GS Evolve 48-port angled panel kit *Modules are not included and must be ordered separately For RoHS Inquiries: CommScope Inc. Corke Abbey, Bray Co. Dublin, Ireland Attn: Legal Department 2015 CommScope, Inc. All rights reserved This product is covered by one or more U.S. patents or their foreign equivalents. For patents, see /ProductPatent/ProductPatent.aspx Page 1 of 11

860584440 SYSTIMAX 360 1100GS Evolve 24-Port Flat Panel and 24-Port Angled Panel How to Contact Us To find out more about CommScope products, visit us on the web at http:/// For technical assistance: Tools Required - Within the United States, contact your local account representative or technical support at 1-800-344-0223. Outside the United States, contact your local account representative or PartnerPRO Network Partner. - Within the United States, report any missing/damaged parts or any other issues to CommScope Customer Claims at 1-866-539-2795 or email to claims@commscope.com. Outside the United States, contact your local account representative or PartnerPRO Network Partner. Phillips head screwdriver Cable jacket scoring tool D-914 punch tool with M110 blade Specifications Wire Termination Wire Size: 22-24 AWG (0.64-0.51 mm) Solid Copper 22-24 AWG (0.64-0.51 mm) Seven Stranded Copper Insulation Size: 0.042 inch maximum DOD Insulation Types: Polyethylene, Polypropylene, and FEP IDC Reterminations: 20 minimum Modular Jack Mating Cycles: 750 minimum Environmental Data Temperature Range: -40 F (-40 C) to 158 F (70 C) (Storage) 14 F (-10 C) to 140 F (60 C) (Operational) Humidity: 95% Noncondensing Page 2 of 11

860584440 Parts List Verify parts against parts list below: 24-Port Flat Panel 48-Port Flat Panel Quantity 24-Port Angled Panel 48-Port Angled Panel 1 24-port flat panel 1 48-port flat panel 1 24-port angled panel 1 48-port angled panel 1 1 Front cover (1U or 2U) Description 1 1 Center cover (1U or 2U) angled panel 2 2 Side covers for angled panel (1U or 2U) right and left 4 4 4 4 P12-24 x ½ mounting screws 1 2 1 2 Cable management bar 4 8 4 8 Cable management troughs 4 8 4 8 Hook-and-loop straps 1 2 1 2 Termination manager kit 4 8 4 8 Rear label, T568A wiring 1 2 1 2 Front label card (4 labels per card) 1 2 1 2 Front label cover card (4 covers per card) 1 1 1 1 Instruction sheet Note: Panel kits include all the parts listed above with the exception of the termination manager kit(s) and T568A wiring labels. These are provided with the separately ordered distribution modules. Separately Orderable Items Contact your SYSTIMAX sales representative for the latest information on the wide variety of 360 InstaPATCH modules that are compatible with the fiber bezel. Distribution modules for the 360 1100GS3/1100GS6 panel kits must be ordered separately and are listed below: Material ID Description 760151167 360 1100GS3 Evolve distribution module 6-port kit 760151183 360 1100GS6 Evolve distribution module 6-port kit 760175877 360 1100G2 Evolve fiber bezel, 4-pack, cool grey 760175919 360 1100G2 Evolve rear cable manager 760175893 360 1100G2 Evolve 1U front cable trough 760175901 360 1100G2 Evolve 2U front cable trough WARNING Important Safety Instructions When using this product, the following basic safety precautions should be followed to reduce the risk of fire, electric shock, and injury to persons: 1. Never install communications wiring in wet locations unless it is designed for wet locations. 2. Never install this product during a lightning storm. There is a remote risk of electric shock. 3. Never touch uninsulated communication wiring or terminals unless the communication circuit has been disconnected at the network interface. 4. Caution: All wiring that connects to this equipment must meet applicable local and national building codes and network wiring standards for communication cable. Page 3 of 11

860584440 Step 1 Mount Panel to Rack 1. Mount panel to rack using the four 12-24 mounting screws provided. After securing panel to rack, snap the Evolve cover(s) onto the front of the panel. Note: Verify the SYSTIMAX name is upright on the flat panel cover and on angled panel center cover before snapping in place. These two covers can be installed upside down. Side covers on angled panel are interchangeable and are not side specific. Instructions for Installing Copper Components in Panel (See Page 7 for Installing Fiber Components) Step 2 Populate Panel with Distribution Modules (For Panel Kits Only) Note: Distribution modules are ordered separately. 1. From the rear side of the panel, insert the front face of the module into the desired panel opening. Press firmly until both the left and right side module snaps fully engage with the panel. When installing modules in either of the two end positions, it is necessary to engage the outermost snap first. Step 3 Terminate Conductors on Rear of Panel T568 Wiring Pairs B 12 3 4 5 6 7 8 A 4 4 8 7 6 5 BR BR W GR OR 3 2 2 3 W W W OR GR 2 1 4 3 BL BL 1 1 Modular Jack IDC Connector Front of Panel Back of Panel T568 Wiring Diagram Entry holes Entry holes Lock tab (2 places) Fold slots (4 places) Termination Manager Note: The module comes with a T568B wiring designation label installed. If T568A wiring is desired, first remove the "B" type label and then place the "A" type label. Do not place the "A" type label on top of the "B" type label. Page 4 of 11

860584440 Note: If using SYSTIMAX GigaSPEED X10D 91B series cable, 95B series cordage, or Xpress 88 series cable, see preparation instructions below. Note: See pages 10 and 11 for proper use of the termination manager. 1. Prepare cable for IDC termination. Terminate conductors on the IDC terminals per the wiring diagram shown above and utilizing the termination manager. Preparation of X10D 91B Series Cable, 95B Series Cordage, or Xpress 88 Cable for Termination Unwind separator tape Pull off to the side so that it can be trimmed close to the jacket Pull flute and tapes off to one or more sides Preparation of the SYSTIMAX GigaSPEED X10D 91B series cable, 95B series cordage, or Xpress 88 series cable is shown above. For complete instructions on preparing these cables for termination, see instruction sheet 860469402. Step 4 Assemble and Install Rear Cable Manager 1. Attach the four cable troughs onto bar as shown and insert four hook-and-loop straps into slots in cable troughs. Page 5 of 11

860584440 2. Attach cable bar to rear of panel. For 48-port panels, two cable bars are provided. 3. Lay cables evenly in cable troughs and secure using hook-and-loop straps as shown. Step 5 Install Front Labels and Label Covers 1. Print the port designations on the white label cards provided. Slide labels and label covers into the label holders from either end. Each label holder will accommodate labels up to.265 inches (6.7mm) high x 3.50 inches (89mm) wide. 2. Blank, voice, and data icons can be ordered separately in a wide variety of colors and placed into the pockets in the lower portion of the label holders. Note: Product code M61K-XX (blank, voice, and data icons) to be ordered separately. XX denotes the color abbreviation. Page 6 of 11

860584440 3. To print a designation label, go to http:///resources/labeling-templates and scroll down to 360 Panels and Shelves. Select the proper label template: 360 Evolve-360 PATCHMAX UNP Label Sheet A4 (760186502) or 360 Evolve 360 PATCHMAX UNP Label Sheet US LTR (760183244). Note: Labeling website has two options for printing labels; letter size and A4 size. Instructions for Installing Fiber Components in Panel Step 2a Install Evolve Fiber Adapter Bezels Note: Fiber modules, bezels, rear trunk cable management bar, and front fiber management trough are ordered separately. 1. Position a bezel against opening from rear of panel. Push bezel from the rear until it snaps into panel opening. Repeat for all bezels. Step 3a Install Evolve G2 Fiber Trunk Cable Management Bar on Rear of Panel 1. Attach fiber management bar to rear of panel immediately behind the fiber row. Place hook at both ends of bar into slots in panel brackets as shown. Step 4a Install Evolve G2 Fiber Management Trough on Front of Panel Note: For instructions on installing the fiber management trough, see 860548809 SYSTIMAX 360 1100 Evolve G2 Fiber Management Trough. 1. Refer to the instructions packaged with the trough and install either the 1U trough on front of the 24-port panel or the 2U trough on front of the 48-port panel. 2. Refer to the instructions packaged with the trough and install designation labels on trough door. Page 7 of 11

860584440 Step 5a Populate Panel with Fiber Modules 1. Orient module in ALPHA or BETA position as required and insert into one of the openings in the panel. 2. Push module into opening until latches engage with an audible click. 3. Repeat for remaining modules. Step 6a Install and Route Fiber Trunk Cables Fiber module (not supplied) MPO connector Fiber routing clips Hook and loop strip Fiber trunk cables (not supplied) Fiber management system 1. Terminate MPO connectors into modules. 2. Slip fiber routing clips over fiber management bar at equally spaced positions, similar to as shown above. 3. Spread open a slot position provided on fiber routing clip and secure fiber cable inside. 4. Repeat until all cables are inserted in the clips and adjust position of clips as necessary to hold the trunk cables in an organized manner. 5. Wrap a strip of hook-and-loop fastener around each fiber routing clip to secure cables. Page 8 of 11

860584440 (Optional Step) Removing Covers from Panel 1. When removing either the flat or angled panel side cover(s), grip cover on the top and bottom at the outside edge where shown by arrows and pull forward. As cover tabs release, position fingers close to tabs to apply further pulling force. 2. For angled panel only, remove both side covers from panel before removing center cover. Page 9 of 11

1 Patch 860584440 Panel Termination Manager Instructions The termination managers provide pair positioning, control, and strain relief features to the rear termination area of the panel. See Figure 1. Instructions for using the termination manager are listed below. Feed Pairs into Termination Manager (Figure 2) 1. Trim jacket back at least 3 inches (76mm) to expose twisted pairs. 2. Without crossing over or rearranging pairs out of the jacket, position pairs in-line per pair colors below: Entry holes Lock tab (2 places) Fold slots (4 places) Entry holes T568B Wiring Application (Shown) Blue, Brown, Orange, Green Figure 1. Termination Manager T568A Wiring Application Blue, Brown, Green, Orange 3. Insert pairs through 4 holes on top surface of termination manager, one pair per hole, as shown. Top surface 4. Continue to feed pairs through termination manager until resistance is encountered at the jacket. This will usually be about 1/4 inch (6mm) from the jacket. Fold Pairs into Slots (Figure 3) 5. Fold each pair over into adjoining slots on bottom end of termination manager. Conductor colors must be arranged in the slots as listed below: T568B Wiring Application (Shown) BL/OR Pairs Blue/Orange conductors on top BR/GR Pairs both White conductors on top T568A Wiring Application BL/GR Pairs Blue/Green conductors on top BR/OR Pairs both White conductors on top Important: Add twist as needed to align pairs with slots. Never remove twist for any pair. Do not allow pairs to untwist inside termination manager or inside cable jacket. 6. Ensure that both conductors of each pair are in slots completely without being pinched over bottom end surface. Blue pair Brown pair Green pair Orange pair Figure 2. Feed Pairs into Termination Manager Blue on top Orange on top White on top Figure 3. Fold Pairs Back into Slots Page 10 of 11

2 860584440 Snap Termination Manager onto Rear Housing (Figure 4) 7. Snap assembled termination manager onto rear housing with pair colors in proper position. Push on using the termination manager housing, not by pushing with the cable. (Ensure that both lock tabs on manager fully seat into rear housing). 8. After termination manager is snapped onto rear housing, untwist individual pairs fully and line up correct color conductor and white conductor with the label on the rear housing. Pairs folded back Seat Wires into IDC Terminal Slots (Figure 5) 9. Grasping each untwisted pair, push the conductors down into IDC terminal slots to seat them before punching down. Seat down into slots as far as possible. (It may be easier to use needle nose pliers to perform this task). 10. Using the D-914 punch tool with M110 blade on HI impact setting, punch down conductors making sure the tool is straight and that conductors fully engage in the IDC terminals. Stagger the punch-down tool up and down, so that it stays in alignment with the staggered terminal slots. Figure 4. Snap Termination Manager onto Rear Housing Remove twists, then push conductors down into terminal slots Recommendations to Aid Assembly 1. The termination manager should be snapped onto the rear housing immediately after the pairs have been fed and folded over into the slots. All termination managers should be installed on the panel before proceeding to seat and punch down conductors. 2. Flex cables down for easier access, then seat and punch down the entire top row of the panel. 3. Flex cables up for easier access, then seat and punch down the entire bottom row. Visible pair entry Figure 5. Seat Untwisted Pairs into IDC Terminal Slots Page 11 of 11