DISTRIBUTION TRANSFORMERS Single-Phase Pad-Mounted

Similar documents
MATERIAL SPECIFICATION ELECTRIC OPERATIONS ORGANIZATION. M3902 ****Supercedes BECo Standard E and ComElectric Spec ****

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

SPECIFICATION FOR THREE-PHASE PAD MOUNT TRANSFORMERS. D. Dead Front, loop feed design shall be employed.

MATERIAL STANDARD ELECTRIC OPERATIONS ORGANIZATION. ****Supercedes BECo Standard E and ComElectric Spec ****

GENERAL INFORMATION POLE MOUNT TRANSFORMER SINGLE PHASE PAD MOUNT TRANSFORMER SINGLE PHASE POLE MOUNT TRANSFORMER THREE PHASE 17

NEW Solutions for Underground System Growth

1500 kva Pad Mount Transformer GRDY/14400V Primary - 208Y/120 Wye Secondary - Oil Cooled

SECTION PADMOUNT TRANSFORMER - OIL FILLED

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

C. System Design and Performance Requirements

Howard Industries. Single-Phase Step

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-115

1TSF /CD Attachment B. City and County of San Francisco Office of Contract Administration

500 kva Pad Mount Transformer V Delta Primary - 208Y/120 Secondary - NEMA 4X - Oil Cooled

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Power IT Liquid Filled Single Phase Padmounted Transformers kva

Three-Phase Pole Mounted Recloser

Single-Phase Step Voltage Regulators

Single Phase Padmounted Transformers kva

Single phase pole mounted. 11kV. Electrical Engineer KEU ID#:

distribution transformers. Single-Phase Overhead GENERAL. Cooper Power Systems manufactures a complete line of single-phase overhead-type

Single-phase step voltage regulators

Figure 1. Single-phase pad-mounted voltage regulator. STANDARD FEATURES

Distribution Transformers

Technical Specification for Pole Mounted Capacitor Rack

C1000 Series Automatic Cap Bank

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Solid Dielectric, Single Phase Reclosers

SECTION PANELBOARDS

ABB Transformadores para aplicaciones solares y eolicas

SUBSTATION TYPE TRANSFORMER - MINERAL OIL FILLED THREE PHASE OISC 65 C RISE 60 HERTZ

MEH Series Sectionalizing Enclosures. Single-Phase and Three-Phase

Proudly Made In America

Dry-Type Transformers Mini-Power Centers

Solid Dielectric, Single Phase Recloser

solutions RUS accepted

Distribution Transformers

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

Midwest Dry Type Transformers

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

Submersible Vacuum Fault Interrupters

Underground Distribution Switchgear

SWITCHGEAR DIVISION PRODUCT PROFILES

Drive Duty Transformer Specification Virginia Transformer Corp. Power Up! Selecting the Right Transformer

Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings

SECTION 27 - PAD-MOUNTED TRANSFORMERS TABLE OF CONTENTS

ME series dead-front fused sectionalizing enclosures MEC current limiting fusing and MEP power fusing 200 Amperes,15-25 kv

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

Single-phase pad-mounted step voltage regulator

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

TECHNICAL SPECIFICATIONS OIL FILLED PADMOUNTED THREE PHASE WYE-WYE TRANSFORMERS

Volt Instrument Transformers

Distribution transformers Efficiency over life-cycle

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008

35-kV Safefront SuperWell Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current Limiting Fuses

Medium Voltage Metal-Enclosed Switches

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

Efficiency is in our DNA

Medium Voltage Metal-Enclosed Switches

RELIABLE POWER COOPER POWER SYSTEMS. Transformer Products Group FROM

Single-Phase Step Voltage Regulator

Static Phase Converters Rotary Phase Converters Double-Throw Switches Fused Disconnect Double-Throw Switches Non-Fused Disconnect Switches Stray

Kuhlman Electric Corporation Volt Instrument Transformers

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

Solid Dielectric, Independent Pole Operated Reclosers Catalog O-vst16

Issued Revised Approved Reviewed October 31, 1984 October 22, 2002 J. Ross J. Fuller

FIXED POWER FACTOR CORRECTION EQUIPMENT 5KV CLASS MEDIUM VOLTAGE SECTION Z

INSTRUCTION MANUAL #103

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

Solid Dielectric, Three Phase Reclosers CATALOG VS11

Three-Phase Ventilated

Transmission & Distribution Glossary of Electrical Terms

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Underground Distribution Switchgear

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

3EK7 Medium Voltage Silicone Insulated Surge Arresters

35-kV Safefront 200 Amp SuperWell Primary Metering Station Pad-Mounted Outdoor

SERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES

Solid Dielectric, Triple Option Reclosers Catalog O-vst14

Molded Vacuum Reclosers The recloser you want, all in one package. Single- and Three-Phase Molded Vacuum Reclosers, 15 38kV

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Fixed, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification

Switchgear Skid, C1192

56-SDMS-07 REV. 01 SPECIFICATIONS FOR

10 Commercial, Industrial, Agricultural Services

Wind Power Solutions. Make Energy Renewable and Reliable!

Automatic, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification

Distribution Arresters

Operators/Accessories. Type V2-CA Aluminum. Vertical Break Switch. Ordering Information Furnish: Available Accessories. Standard Operator Features

Single-Phase Ventilated

Kuhlman Electric Corporation Volt Instrument Transformers

750 kva Transformer V Delta Primary Voltage - 480Y/277 Wye-N Voltage Secondary - NEMA 3R

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Transcription:

DISTRIBUTION TRANSFORMERS Single-Phase Pad-Mounted HOWARD INDUSTRIES, INC. ISO-9001 CERTIFIED Bulletin 1002

Howard Industries Excels at Delivering Exactly What Our Customers Want. The Product Automated Design System (PADS) insures that each customer s unique requirements are satisfied. HOWARD ISO INDUSTRIES, 9001 INC A6901 Life-Cycle Cost Reduction Howard Industries Customer Assistance Team excels at helping customers find ways to reduce cost. Using activitybased cost analysis techniques, our commercial and technical experts help customers analyze costs throughout the transformer supply chain, identifying and eliminating activities which add cost but have little or no value. Quality and Reliability Built into Every Transformer Higher quality means lower failure rates and that translates into lower operating and maintenance costs. Higher quality also means customers can reduce cost by reducing or eliminating incoming receipt inspection and testing. At Howard Industries our Quality Assurance Program is designed to achieve the high level of quality required by our most demanding customers. Abandoning the traditional manufacturing-only focus, we have created a quality system that links all aspects of the company s operations including Marketing, Engineering, Management Information Systems, Manufacturing, Shipping and Accounting to make sure that not only our products, but everything we do for our customers is of the highest quality. Howard Industries quality management system has earned ISO-9001 certification. ISO-9001, the most comprehensive standard in the internationally recognized ISO-9000 series, covers design, manufacturing and servicing systems. This achievement demonstrates Howard Industries commitment to continuous quality improvement.

Automated and robotic welders perform 100% of all oilcompartment seam welds. Electrostatically applied powder paint provides a durable, corrosion-resistant finish. Computerized final test stations perform a complete series of electrical tests prior to shipment. Designs Optimized for Superior Performance and Economy Our design philosophy is to provide our customers exactly what they want. That means transformers that are individually designed in precise accordance with each customer s specifications. Each transformer design is optimized to satisfy the customer s needs at the lowest possible cost. requirements are satisfied. PADS synthesizes each transformer design and produces all critical manufacturing documents. PADS then links with a sophisticated computerintegrated-manufacturing (CIM) system to automatically carry-out fabrication on the factory floor. The PADS and CIM systems eliminate manual processes and their inherent inefficiency and error, and make it possible to quickly modify and customize transformer designs. Advanced Manufacturing Howard transformers are manufactured in the largest, most advanced facility of its kind. The 1.6 million square foot Laurel plant is the result of a recent three-year, $50 million expansion project, which saw the introduction of the latest and most sophisticated robotics and automated process equipment available. Howard s Product Automated Design System (PADS) is driven directly by each customer s specifications to insure that all the necessary

Single-Phase Pad-Mounted Transformer Features Howard Industries offers a complete line of low profile single-phase pad-mounted distribution transformers that are ideal for use on any residential or commercial underground distribution system. Basic styles include the ANSI Type-1, ANSI Type-2 and the compact Space-Saver TM, all designed to satisfy the most demanding requirements for safety, reliability and aesthetics. In addition to a full complement of standard features, many value-added options and customized design services are available to serve special applications. Standard Features Meets or exceeds current ANSI, NEMA and RUS standards as applicable Full compliance with ANSI C57.12.28 enclosure integrity standards Two externally clamped universal high-voltage bushing wells for loop feed operation or one externally clamped bushing well for radial feed operation Three externally clamped low-voltage with threaded copper studs, including a fully insulated neutral terminal with removable ground strap (removable ground strap standard on 240/120 and 480/240 ratings only) Embossed bushing mounts Threaded, flush mounted stainless steel lifting provisions Automatic pressure relief device Electrical grade mineral oil with oxidation inhibitor Removable hood with corrosion resistant stainless steel hinge pins and barrels Mild steel enclosure and detachable sill fastened with stainless steel hardware Recessed oil compartment bottom Electrostatically applied powder paint finish with polyurethane top coat for excellent resistance to chipping, fading, abrasion and corrosion Front panel accessory mounting bracket Domed top surfaces on hood and oil compartment to prevent water retention Oil fill/oil level plug Oil drain plug Tank grounding provisions Corrosion resistant locking assembly with captive penta-head security bolt, floating nut and padlock provision Decal or stenciled bushing designations Laser engraved anodized aluminum nameplate

Standard KVA and Voltage Ratings Transformer shown on optional Pad/Pallet TM ANSI Type 2 KVA Ratings (65 rise) 5, 10, 15, 25, 37.5, 50, 75, 100, 167, 250 High-Voltage Ratings 4160GrdY/2400 through 34500GrdY/19920 or 2400/4160Y through 19920/34500Y (60kV through l50kv BIL) Low-Voltage Ratings 240/120, with 3 low-voltage 120/240, with 4 low-voltage 480/240, with 3 low-voltage 240/480, with 4 low-voltage 120, with 2 low-voltage 240, with 2 low-voltage 277, with 2 low-voltage 480, with 2 low-voltage (30kV BIL) ANSI Type 1 KVA Ratings (65 rise) 5, 10, 15, 25, 37.5, 50, 75, 100, 167, 250 High-Voltage Ratings 4160GrdY/2400 through 34500GrdY/19920 or 2400/4160Y through 19920/34500Y (60kV through 150kV BIL) Low-Voltage Ratings 240/120, with 3 low-voltage 120/240, with 4 low-voltage 480/240, with 3 low-voltage 240/480, with 4 low-voltage 120, with 2 low-voltage 240, with 2 low-voltage 277, with 2 low-voltage 480, with 2 low-voltage (30kV BIL) Space-Saver TM KVA Ratings (65 rise) 5, 10, 15, 25, 37.5, 50 High-Voltage Ratings 4160GrdY/2400 through 24940GrdY/14400 (60 through 125kV BIL) Low-Voltage Ratings 240/120, with 3 low-voltage or 3 cable leads 120/240, with 4 cable leads 480/240, with 3 low-voltage or 3 cable leads 240/480, with 4 cable leads 120, with 2 low-voltage or 2 cable leads 240, with 2 low-voltage or 2 cable leads 277, with 2 low-voltage or 2 cable leads 480, with 2 low-voltage or 2 cable leads (30kV BIL) (Note: Contact your distributor or factory representative for availability of other kva sizes, voltage ratings, features, accessories and design standards not listed.)

Optional Features, Accessories and Design Standards As an Energy Star Partner, Howard Industries has determined that its optional Energy Star Compliant transformers meet the Energy Star guidelines for energy efficiency. Howard Industries is a charter member of the Energy Star Transformer Program. Total stainless steel or hybrid (mild steel/ stainless steel) enclosure; hybrid enclosure may have stainless steel applied to any of the following components: hood, sill, oil-compartment riser, bottom/front panel, and high-voltage bushing clamps. Available grades of stainless steel include 409, 304 and 304L High density polyethylene protector strips on bottom contact surfaces to prevent paint damage during storage and installation Molded polymer Pad/ Pallet TM serves as both shipping pallet and permanent mounting pad; can be factory mounted to transformers through 50 kva Temporary service access provision (conduit hole) High-voltage, load-break on/off or sectionalizing switch Fault indicator Fault indicator provision only Load-break high-voltage bushing inserts Removable low-voltage ground strap (standard for 240/120 and 480/240 ratings) Low-voltage terminals, including various screwon spades or slip-fit connectors Internally mounted expulsion fuse (alone or in combination with internally mounted, partial-range current limiting fuse) Draw-out expulsion fuse in combination with internally mounted partial-range current limiting fuse or isolation link (current limiting fuse not available on Space- Saver TM designs) Draw-out (dry well) fullrange current limiting fuse (not available on Space-Saver TM designs) Drip shield for use with draw-out expulsion fuse Internally mounted fullrange current limiting fuse (not available on Space-Saver TM designs) Low-voltage circuit breaker with or without emergency overload lever (not available on Space- Saver TM designs) MOV high-voltage lightning arrester: external plug-in elbow type, or under-oil mounted with or without external disconnect High-voltage tap switch with operating handle in the terminating compartment with one of the following tap ranges: four 2.5% taps above normal; or four 2.5% taps below normal; or two 2.5% taps above and two 2.5% taps below normal; or taps at 13800/13200/12870/ 12540 for transformers with a nominal highvoltage rating of 14400 (high-voltage taps not available in combination with dual high-voltage ratings) Dual high-voltage switch with operating handle in the terminating compartment (not available in combination with high-voltage tap switch) Interlaced low-voltage windings Drain valve with or without sampling device Temperature gauge Liquid level gauge Pressure/vacuum gauge Tank ground connectors Hold-down cleats Lifting bolts Custom stenciling and labeling Laser engraved stainless steel nameplate NEMA safety labels Energy-efficient amorphous metal cores (available through 100 kva) Rural Utilities Service (RUS) design standards Canadian Standards Association (CSA) design standards and other non- U.S. standards U.S Energy Star compliant designs NEMA TP-1 compliant designs (Note: Contact your distributor or factory representative for availability of other kva sizes, voltage ratings, features, accessories and design standards not listed.)

Howard Industries Distribution Transformers are Available in a Complete Range of Types, Sizes and Voltage Ratings. Single-Phase Pole-Mounted Three-Phase Pole-Mounted Single-Phase Pad-Mounted Single-Phase Subsurface Available in capacities ranging from 1.0 through 833 kva. Voltage ratings through 19.9/34.5 kv, 200 kv BIL. Refer to Bulletin 1001 Available in capacities ranging from 30 through 150 kva. Voltage ratings through 34.5/19.9 kv, 150 kv BIL. Refer to Bulletin 1001 Available in capacities ranging from 10 through 250 kva. Voltage ratings through 19.9/34.5 kv, 150 kv BIL. Refer to Bulletin 1002 Available in capacities ranging from 10 through 250 kva. Voltage ratings through 19.9/34.5 kv, 150 kv BIL. Refer to Bulletin 1003 Three-Phase Unit Substation Available in capacities ranging from 45 through 10,000 kva. Voltage ratings through 34.5/19.9 kv, 250 kv BIL. Refer to Bulletin 1004 Three-Phase Pad-Mounted Available in capacities ranging from 15 through 10,000 kva. Voltage ratings through 34.5/19.9 kv, 250 kv BIL. Refer to Bulletin 1005

Facilities Howard Industries operates three manufacturing facilities including locations in Laurel, Sandersville and Mendenhall, Mississippi, and two service locations in Ellisville, Mississippi, and Weirton, West Virginia. Every Howard facility utilizes the latest available technologies to provide its customers with world-class products and services. Laurel Transformer Facility Located in Laurel, Mississippi, the 1.6 million square foot facility is responsible for production of the company s electrical distribution transformer product lines and is also corporate headquarters for Howard Industries, Inc. Sandersville Ballast Facility The Sandersville, Mississippi facility is headquarters for the Lighting Ballast Division and produces the company s line of electronic fluorescent lighting ballasts. The Sandersville facility is also home for Howard Computers. Mendenhall Ballast Facility The Lighting Ballast Division s lines of magnetic fluorescent ballasts and high-intensitydischarge ballasts are produced at its facility located in Mendenhall, Mississippi. Ellisville Transportation Facility The Ellisville, Mississippi facility is the location for Howard Transportation, Inc., including its corporate headquarters, truck maintenance shop and computerized dispatch center. A regional terminal is located in Weirton, West Virginia (not pictured). Howard Industries Business Units www.howard-ind.com www.howard-ballast.com www.howardcomputers.com www.howard-ind.com Transformer Division Howard Industries Transformer Division is this country s leading manufacturer of oil-filled electrical distribution transformers. The Laurel manufacturing facility produces a complete line of overhead, padmounted, subsurface and unit substation transformers that are widely used by electric utilities, and by industrial and commercial operations. Lighting Ballast Division Howard Industries Lighting Ballast Division is a world-class supplier of magnetic and energyefficient electronic fluorescent ballasts, and of high-intensitydischarge (HID) ballasts for the lighting industry. Computer Division Howard Industries newest business unit, Howard Computers, manufactures a complete selection of built-toorder personal computers, including servers, desktops, towers and notebooks. Transportation Division Howard Transportation, Inc., a wholly-owned subsidiary of Howard Industries, Inc., operates as a full-load, flat-bed common carrier truck line and brokerage operation, transporting commodities and industrial goods throughout the continental United States. Visit our web site at http://www.howard-ind.com ISO-9001 CERTIFIED Bulletin 1002-01. Printed in USA. 2001 Howard Industries, Inc. All rights reserved. HOWARD INDUSTRIES, INC. P.O. BOX 1588 LAUREL, MS 39441-1588 (601) 425-3151 FAX (601) 649-8287 E-mail: mkt@howard-ind.com