CTE9000 / CTU9000 Series OEM pressure transmitters for industrial media

Similar documents
CTE7000 / CTU7000 Series Miniature pressure transmitters

CTE8000 / CTU8000 Series

BTE2000 / PTE2000 Series Precision stainless steel pressure transmitters

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

DCT 533. Industrial Pressure Transmitter with IO-Link Interface. Stainless Steel Sensor

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

Pressure transmitter for industrial applications Type MBS 4510

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Pressure transmitters for industrial applications Type MBS 4510

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

OEM Pressure Transmitters

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

Pressure transmitter for industrial applications Type MBS 4500

Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

JUMO MIDAS Pressure transmitter

Industrial Pressure Transmitters

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

Type A-10 General Purpose Pressure Transmitters

Pressure Transmitter. Pressure transmitter with compact design Model EDC-K. Electronic. Applications. Special Features.

SITRANS P measuring instruments for pressure

Pressure transmitter for marine applications MBS 33M

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

JUMO MIDAS S05 Pressure transmitter Type

High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250

DMP 331. Industrial Pressure Transmitter for Low Pressure DRUCK & TEMPERATUR LEITENBERGER GMBH. Stainless Steel Sensor

Pressure transmitters for heavy duty applications MBS 3200 and 3250

Figure 1: WPR2 Dimensions and Hardware

Type A-10 General Purpose Pressure Transmitter

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

Pressure transmitter for marine applications MBS 3100 and MBS 3150

Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

EB100 High Accuracy Miniature Pressure Transducer

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters

M5200 Industrial Pressure Transducer

Micro-Machined Silicon Transducers

PX409 Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-10 inh2o to psid

DMP 333. Industrial Pressure Transmitter For High Pressure DRUCK & TEMPERATUR LEITENBERGER GMBH. Stainless Steel Sensor

Pressure transmitter for general purpose Type MBS 1700 and MBS 1750

Pressure Transmitter JUMO dtrans p30 Type

Mountable with O-ring seal Urea level ±0.5% Accuracy Urea pressure ±2.0 Total Error Band Air Brakes Corrosive fluid measurement for E&V applications

SSI Technologies Application Note PS-AN2 MediaSensor Absolute & Gage Pressure Transducers & Transmitters Product Overview

Pressure Transmitters for Sanitary Applications Model SA-11

Electronic Pressure Switches

Pressure transmitters for heavy duty applications Type MBS 3250

Features. Pressure & temperature combined. Sub miniature and light sensor. Temperature output. Built-in electronic Vdc

Pressure transmitter for general applications Model S-10, standard version Model S-11, flush diaphragm

OEM Pressure Transmitters

Electronic Pressure Switches

OEM Pressure Transmitters for heavy-duty applications Type MBS 1200 and MBS 1250

Pressure transmitter for marine applications Type MBS 5100 and MBS 5150

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

Pressure transducer DMU 01K Compact version

SSI Technologies MediaSensor

P255 Stainless Steel Pressure Transducer

LMK 387. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

AST44LP Intrinsically Safe Low Pressure Transducers / Transmitters

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Features. Available with 0,5-4,5Vdc output. Operating from -40 to +140 C. Designed for harsh environment. Large Bandwidth

Special Purpose Transmitters

MBS 1200 and MBS 1250

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

PRESSURE BENCH OPERATING INSTRUCTIONS

SATRON VTe pressure transmitter

Pressure Transmitters

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview

UNIK Pressure Sensing Platform. GE Sensing & Inspection Technologies. Features

Marine Pressure ECTN Applications. Features

Switch to. Generation NEW Electronic Level. One Series for. Pressure Temperature Level

Ultra High Purity Transducer, Ex na nl Models WU-20, WU-25 and WU-26

PRESSURE TRANSMITTER PYRP-28 INDUSTRIAL & INTRINSICALLY SAFE PRESSURE TRANSMITTER PRESSURE TRANSMITTER

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

Selectable ranges and an LCD are a technician s best friend, that s why we make them standard on every dry media differential pressure sensor!

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

OEM Pressure transmitter for industrial applications Type MBS Technical brochure

Industrial Pressure Transmitter

Installation and Operation Instructions DLP Series

Data Sheet P4055 Pressure Transducer

Millivolt Output Pressure Sensors

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

Relative and absolute pressure transmitter type 691

PFT - the Flexible Pressure Transmitter

Differential Pressure Sensors

SATRON VT Pressure Transmitter

SATRON VDt Differential Pressure Transmitter

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

MS52XX SMD Pressure Sensor

Pressure Transmitter for wind turbine applications MBS 8200 and MBS 8250

Pressure measurement PP20H Fully welded hygienic pressure sensor with flush membrane

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.

EPI Applications. Features

FPT Applications. Features

MELT PRESSURE TRANSMITTERS K7 SERIES PERFORMANCE LEVEL c

Transcription:

FEATURES mbar to 35 bar, 15 to 500 psi gage 1 or absolute 10 pressure 05, 010, 0545, 16 or 420 ma output Field interchangeable All welded stainless steel diaphragm construction EMC according to EN 61326-1 8 MEDIA COMPATIBILITY Wetted materials: Stainless steel 14404 (316L) 9 Housing: Stainless steel 14404 (316L), protection class IP 6 (according to DIN EN 60529, NEMA 6) 1 SPECIFICATIONS 11,12 ELECTRICAL CONNECTION Maximum ratings Supply voltage (reverse polarity protection) CTE(M)/CTU90 1232 CTE(M)/CTU91 932 CTE(M)/CTU96, 832 CTE(M)/CTU94 2 32 Maximum load current (source) CTE(M)/CTU90, 1, 6, 1 ma Proof pressure 3 2 x rated pressure Environmental Temperature limits Storage -4085 C Operating (media) -4085 C Electronic (ambient) -4085 C Compensated 050 C ibration (5 to 2000 Hz) 13 10 g RMS oltage output device 1 / brown out sensor 2 / green 4 / yellow case 3 / white/shield output device 1 / brown N/C sensor 2 / green R L out Mechanical shock 14 50 g (11 ms) 4 / yellow case 3 / white/shield 1/6 wwwfirst-sensorcom

COMMON PERFORMANCE CHARACTERISTICS ( S =15 ±01, T A = C, RH=50 %) Thermal effects 4 ( 050 C) Thermal effects -200 C, 500 C) ( 4 M in T yp Max Offset Span Offset Span mbar/15 psi devices ± 004 ±008 ± 002 ±005 mbar/15 psi devices ± 004 ±008 ± 002 ±005 mbar/15 psi devices ±004 ±002 mbar/15 psi devices ±004 ±002 5 N on-linearity ( BSL) and hysteresi s ± 0 1 ±0 3 Repeatability ±0 1 6 Long term stability ±0 1 noise (0 < f < 1 khz) ±0 1 %FSO/ C %FSO Response time (10 to 90 %) 5 ms D/A resolution 11 bit Power supply rejection Offset ±001 Span ±002 %FSO/ INDIIDUAL PERFORMANCE CHARACTERISTICS ( S =15 ±01, T A = C, RH=50 %) 010 output (R L M in T yp Max CT9N 4 9 5 5 1 0 0 1 CT9N 4 9 5 5 1 9 9 10 10 1 0545 output (R L M in T yp Max CT9N 245 2 5 5 045 0 5 055 CT9N 195 2 205 395 4 405 2/6 wwwfirst-sensorcom

INDIIDUAL PERFORMANCE CHARACTERISTICS (cont) ( S =15 ±01, T A = C, RH=50 %) 05 output (R L M in T yp Max CT9N 245 2 5 5 0 005 CT9N 245 2 5 5 495 5 0 505 16 output (R L M in T yp Max CT9N 345 3 5 355 095 1 105 CT9N 245 2 5 5 495 5 0 505 420 ma output (R L = ) M in T yp Max CT9N 11 8 12 0 12 2 3 8 4 0 4 2 ma CT9N 8 8 0 8 2 15 8 16 0 16 2 Power consumption (I = 20 ma) 0 mw L LOAD LIMITATION 420 ma output version 1400 Ohm 1200 0 800 600 400 operating range 200 0 5 10 16 20 30 32 supply voltage 3/6 wwwfirst-sensorcom

OUTLINE DRAWING Connector version NOM 850 (335) 65 (026) 650 (6) 4 vent hole¹ 218 (086) diam G 1/8" (BSP) 1 3 Cable version 65 (026) Detail A 650 (6) NOM 150 (059) M12 x 1 2 2 m (84) other lenghts available Pin oltage 1 + s 2 out N/ C 3 Case Case 4 218 (086) diam G 1/8" (BSP) Shield ent tube Detail A Flying lead end Brown Green White and shield Yellow oltage + s out N/ C Case Case Detail A 148 (058) 92 (036) 40 (016) diam O-ring grove 14 (0055) mass: approx 82 g Note: O-ring included in delivery dimensions in mm (inches) 4/6 wwwfirst-sensorcom

RECOMMENDED ACCESSORY (not included in delivery) ZP000112-B: Mating Connector (without cable) ZK000101-x: Connector/cable assembly (x=cable lenghts in m, max 10 m) 365 x = length in m (max 10 m) NOM 60 Shield ent tube Pin PIN CONNECTION Flying lead end 1 Brown 2 Green 3 White and shield 4 Yello w M12x1 Ø 20 Note: For proper function of gage devices the vent tube must have access to the ambient atmosphere dimensions in mm OPTIONAL PRESSURE FITTINGS (brass, nickel plated) Male fittings B C Female fittings G F A D E H Dimensions in mm (inches) A B C D (Hex) 1 /8" BSPT 8 (0315) 13 (0512) 14 (9/16") 1 /4" BSPT 12 (042) 5 5 (021) 14 (9/18") 3 /8" BSPT 115 (0453) 5 (019) 1 (11/16") 1 /2" BSPT 16 (0630) (026) 22 (/8") 1 /8" BSP 1 (0492) 11 (0433) 14 (9/16") 1 /4" BSP 8 5 (0335) 5 (019) 19 (3/4") 3 /8" BSP 1 (0492) (026) 22 (/8") 1 /8" NPT 10 (0394) 13 (0512) 1 (11/16") 1 /4" NPT 14 (0551) 6 (0236) 22 (/8") Dimensions in mm (inches) E F G H (Hex) 1 /8" BSP 5 (019) 15 (0591) 14 (9/16") 1 /4" BSP (026) 20 (08) 1 (11/16") 3 /8" BSP 6 (0236) 20 (08) 22 (/8") 1 /2" BSP 18 (00) 23 (0906) 24 (15/16") 5/6 wwwfirst-sensorcom

Specification notes: 1 IP 64 protection is given when the connector is locked For proper function the gage port is vented to the atmosphere through the connector/cable assembly Thus the cable end must have access to the ambient pressure 2 The minimum supply voltage is directly proportional to the load resistance seen by the transmitter For more details see the load limitation diagram 3 Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element 4 Thermal effects are relative to C Signal is clamped at 0 5 Non-linearity refers to Best Straight Line fit Hysteresis is the maximum output difference at any point within the operating pressure range for increasing and decreasing pressure 6 Long term stability over 1 year Span is the arithmetic difference in transmitter output signal measured at zero pressure and the maximum operating pressure 8 Surge immunity according to EN 60-4-5 on request for current output devices 9 When using devices with optional nickel plated fittings, consider the media compatibility of the fittings also 10 Available for pressure ranges from 1 bar (15 psi) absolute upwards only 11 CE-labelling is in accordance with 2004/108/EC 12 The pressure transmitters must not be used as safety accessories according to article 1, 213 of the directive 9/23/EC 13 According to IEC 60068-2-64 14 According to IEC 60068-2-2 ORDERING INFORMATION Calibration E: bar calibration U: psi calibration For mbar ranges only Pressure range CTE9000 series CTU9000 series : 0 mbar 1x5: 015 psi 200: 0200 mbar 003: 03 psi 350: 0350 mbar 005: 05 psi 001: 01 bar 015: 015 psi N01: -1+1 bar N15: -1515 psi P01: 0-1 bar P15: 0-15 psi 002: 02 bar 030: 030 psi 003: 03 bar 050: 050 psi 005: 05 bar : 0 psi 010: 010 bar 300: 0300 psi 016: 016 bar 500: 0500 psi 020: 020 bar 035: 035 bar Pressure mode G: gage pressure 1 A: absolute pressure (from 1 bar/15 psi only) CTx (M) 9xxx x x x (C x) Other pressure ranges and options are widely available Please contact First Sensor Cable lenght in m Cable version (optional) signal 0: 010 1: 16 4: 420 ma 6: 0545 : 05 Pressure connection Standard thread Y: G 1/8" (BSP) male, SS 14404 (316L) Optional pressure fittings D: 1/8" BSPT male, brass, nickel plated E: 1/4" BSPT male, brass, nickel plated F: 3/8" BSPT male, brass, nickel plated G: 1/2" BSPT male, brass, nickel plated K: 1/8" NPT male, brass L: 1/4" NPT male, brass M: 1/8" NPT male, SS 14404 (316L) N: 1/4" NPT male, SS 14404 (316L) P: G 1/8" (BSP) male, brass, nickel plated Q: G 1/4" (BSP) male, brass, nickel plated R: G 3/8" (BSP) male, brass, nickel plated S: G 1/2" (BSP) male, brass, nickel plated U: G 1/8" (BSP) female, brass, nickel plated : G 1/4" (BSP) female, brass, nickel plated W: G 3/8" (BSP) female, brass, nickel plated X: G 1/2" (BSP) female, brass, nickel plated First Sensor reserves the right to make changes to any products herein First Sensor does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of 6/6 wwwfirst-sensorcom