AE-770 Electrostatic Field Meter

Similar documents
Electrostatic Fieldmeter

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L

NOTES TO USERS. INSTRUCTIONS Installation/Operation/Maintenance

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L

INTRODUCTION. Backlight for operating in dark area Low battery indicator Auto power off function. CO levels and its effect

User's Manual Digital High Voltage Insulation Tester Model

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T )

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Solar Power Light Meter

PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL USA From outside US: +1 Tel: (561) Fax: (561)

User Guide. Model Insulation Tester / Megohmmeter

Beamex MB METROLOGY TEMPERATURE BLOCK. Portable temperature dry block delivering bath-level accuracy for industrial applications

Quick Guide. brite Advanced Retail scale

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Digital Formaldehyde Meter

Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

Atlas 5. Instruction Manual. Handheld Indoor Air Quality Monitor. Measures CO2, Temperature and Humidity DISTRIBUTED BY

Advanced Test Equipment Rentals ATEC (2832)

PCE-CS 300. Crane Scales up to 300 kg ( 661 lb)

OD10 10A Outdoor Solar Charge Controller

MIT515, MIT525, MIT1025, MIT1525

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

MANUAL TPMS CRX 1002/1003

EVERLIGHT ELECTRONICS CO., LTD.

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

DIGITAL RCD(ELCB) TESTER

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

Features Description Applications

EMF TESTER OPERATION MANUAL. ELECTROMAGNETIC FIELD RADIATION TESTER Model : EMF-832

15-22/R6G6C-A32/2T SMD B

Series IZS31. RoHS compliant

Technical Data Sheet Chip LED with Bi-Color(Multi-Color)

NAO E36 A Rechargeable headlamp with self-adjusting lighting - REACTIVE LIGHTING technology

SCALIX MULTIPURPOSE SCALES SCALIX COMPACT SCALE FKS-600 FKS-6000 INSTRUCTION MANUAL

23-23B/R6GHBHC-A01/2A

testo 535 Instruction manual

Hot Wire CFM/CMM Thermo-Anemometer

IDEAL INDUSTRIES INC. TECHNICAL MANUAL - SUPPLEMENT MODEL

User manual. Active neutralizing electrode JO96/1/L

INSTRUCTIONS Installation/Operation/Maintenance

2-Color Display High-Precision Digital Pressure Switch

SMD B 15-22/R6G6C-A32/2T

MoistureMatch A next generation grain tester

Instruction Manual. Coating Thickness Gauge. Optionally with Memory

17-223/R6G6C-D30/3C SMD B

Ionizer. Discharge time: 0.3 seconds. Series IZS31. Ion balance control by an autobalance sensor CAT.EUS100-68A-UK. Without sensor.

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

Digital/Analog Megohmmeter Model 1026

TIF VA500A DIGITAL HVAC ANALYZER

USER GUIDE. Model RH10 Hygro Thermometer. Humidity and Temperature Meter

LCD S900 User Manual. The Latest Version 2014

DMG200. Digital Micron Gauge. 99 Washington Street Melrose, MA Phone Toll Free

User Guide. Model Insulation Tester / Megohmmeter

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

IR-500 Infrared Thermometer / Voltage Detector / Flashlight

Features Description Applications

User Manual. CFM/CMM Vane Thermoanemometer. Model with NIST-Traceable Calibration THE STANDARD IN PRECISION MEASUREMENT

MXR-S-300 Series with 24V DC Input and 50kV Output

TireMoni Checkair TM-4xx / 5xx / 6xx

Lithium Battery Protection Integrated Circuit

NPS Series. Pallet Jack Scale Operator s Guide (V1611)

Cordless LED Lamps. Compatible with all standard leak detection dyes Powered by a rechargeable NiMH battery 120V, 230V, 240V or 100V smart AC charger

TABLE OF CONTENTS. chargex - Onboard charger chargex mini Charger with EL display

USER MANUAL. Insulation Tester + DMM. Model MG320

Harness the Power of the Sun

S1-568, S1-1068, S1-1568

Air-Purifying Smoke Absorber

LIST OF CONTENTS TESTING EQUIPMENT

INSULATION RESISTANCE TESTER FOR PHOTOVOLTAIC SYSTEMS MSEI-200C INSTRUCTION MANUAL

AMB V Insulation Resistance Tester. Users Manual. For detailed specifications and ordering info go to

Digital/Analog Megohmmeter Model 1026 USER MANUAL

Low Pressure Sensor. Overview. Specifications. Installation and Operation

Digital Apex Locator. ipex OPERATION MANUAL OM-E0285E

Mobility. Energy. Anytime. Anywhere.

ETHOS Digital Sound Level Meter. Operating Manual

Multi-function Auto Circuit Tester

Marin Control Digital

Activator 282 Aircraft Battery Maintenance Charger Operator Manual

True RMS Autoranging Multimeter

Autoranging Industrial Multimeter

2-Color Display High-Precision Digital Pressure Switch

MA-LINE INSTRUMENTS

Model Battery Powered Milliohm Meter

Autoranging Multimeter

Budget Series Digital Thermometer. Instruction manual Models 874F/C, 875F/C, 878 and 879

User Guide. Model Insulation Tester / Megohmmeter. Introduction

MANUAL ELECTROMAGNETIC FIELD RADIATION TESTER EMF 823

Crane Scale. NC Series OWNER S MANUAL

Model Insulation Tester / Megohmmeter. User Manual

Digital Electronic Torque Wrench. Operating Manual. Model 60648

Exceptional Value Improves Lighting Quality Reduces Energy Costs. Industrial Grade LED Task Lights

SMD Low Power LED 45-21/XK2C- SXXXXXXXXX/2T

Weighing Scale IDS-802. User Manual

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Digital Insulation Resistance Testers. you can depend on

Breath Alcohol Tester

Industrial Grade LED Task Lights. Exceptional Value Improves Lighting Quality Reduces Energy Costs. aveninc.com

How to Order BS B. Nil. Bracket (End bracket, Center bracket) Nil

LIGHT AND POWER SOURCES POWER SOURCES

Transcription:

AE-770 Electrostatic Field Meter Palm-sized electrostatic measuring device ideal for checking ion balance and Sensor for polarity of static charge. Static Super Scale Features: Measuring polarity and intensity of static charge on parts and assembly lines Checking ion balance performance of various ionizers 1

Technical Specification: Measuring range Measuring distance Accuracy Ambient conditions Display Power Weight with battery Case material Accessories Applications Static voltage measuring range Ion balance voltage measuring range 25 mm ± 0.5 (between charged object and field meter) ±10% 10 C ~ 40 C, 680%RH or lower Large LCD display (Digital and bar graph) 9V, 6F22Y manganese battery: 1PCE (Life: Approx. 30hours) ± 0 ~ ± 1.49 kv (Low range) ± 1.0 ~ ± 20.0 kv (High range) 0 ~ ± 200 V Approx. 140g without ion balance plate (Ion balance plate : Approx. 30g) Conductive resin (ABS) Charge plate for ion balance measurement :1PCE Ground cord : 1PCE (w/ alligator clip) Battery : 1PCE (006P) Soft case : 1PCE For checking the performance of ionizers, locating and measuring electrostatic charge build-up, deciding best location for installing ionizers and testing their efficiency, etc. 2

Dimensions: 3

Multifunctional static field meter AE-770 with an incorporated one-chip microcomputer 4

Function to check the static charge Static charge measurement mode (Standard mode)" to check if the object is statically charged. The digital numerical value and the bar graph displayed on the LCD indicate the static voltage on the target object. AE-770 is calibrated for the voltage range 0 to ±20kV. For accurate measurement, make sure to ground AE-770 with its ground wire. If the reading blinks at [±22.0] with a continuous The unit of measurement : warning sound during the kv static charge measurement, maximum voltage reading limit has been exceeded. "Focus-Ring LEDs" show you the proper measuring distance. The measuring distance between AE- 770 and the target object needs to be 25mm±0.5mm. This measuring distance can be easily checked by Focus Rings beamed from the two red LEDs on the sensor side of AE- 770. Position AE-770 where the two red light beams converge as one concentric circle for accurate measurement. How to activate "standard mode" "Automatic ranging digital display" Press "POWER" button once and the unit will be set to "static charge measurement mode (standard mode)." While 5

in standard mode, the decimal point is automatically set to a right position. Function to check the ion balance of ionizers "Ion balance measuring mode" to check the performance of ionizers. AE-770, designed to be compact and lightweight, making it ideal for periodic verification of ionizers, including those installed on hard-toreach places like automated machinery or workbenches. AE-770 can be used to measure low voltages up to 200V in the ion balance mode. Installing "the ion balance plate" before measurement. Before starting ion balance measurement, install the ion balance plate to the top end having the sensor. For accurate measurement, make sure to ground AE-770 with its ground wire. How to activate "standard mode" The ion balance plate is kept on the bottom end. Turn AE-770 on by pressing POWER button and then press ION BALANCE button. The ion balance plate can be kept attached to the bottom end when not in use. 6

Easy-to-see large LCD display "Wide LCD display" with three sections. The upper left section displays bar graph in blue to indicate negative polarity voltage. The upper right section displays bar graph in red to indicate positive polarity voltage. The lower section display shows reader-friendly numerical values, voltage measurement unit, and functions in use. "Battery condition display" to know when to replace the battery. The battery condition icon changes in 4 stages as the battery level decreases. Replace the battery when display shows the battery to be The life of the included 9V, 6F22 Manganese battery : Approx. 30hours. empty. "LED lighting function" to read measurement values in the dark. Switch on and off the LCD backlight by the POWER button. Turn off the LED: Keep POWER pressed for less than 1 sec or 3-5 sec. When turned on to the standard mode 1 beep AE-770 indicates its operating status by beep sound. Beep sound represents the following conditions: When turned on w/o auto power off function 3 beeps Auto power off indication 5 beeps Over range 1 long beep Turn on the LED : Keep POWER pressed for 1-3 secs or more than 5 secs. 7