Model DFD-350. Dynamic Rated Fire Damper 3 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Similar documents
Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Fusible Link (replaceable) Horizontal Mount

Model FD-350. Static Rated Fire Dampers 3 Hour Fire Resistance Rating. Application. Ratings. Construction Standard Optional.

Fusible Link (replaceable) Horizontal Mount

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

Model FSD-331 Combination Fire Smoke Dampers

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model FSD-212. Combination FIRE SMOKE DAMPERS

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

HCD-230 Industrial Control Damper

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

AMD-33 Air Measuring Station with VCD-33 Control Damper

Fire Dampers Catalogue

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

Motorized Fire Dampers

Model VCD-20 3V CONTROL DAMPER

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

Life Safety Dampers. Fire Combination Fire Smoke Smoke Ceiling Radiation

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

Fire, Smoke, and Combination Fire Smoke Dampers

Dynamic & Static Rated Fire Dampers, Ceiling Radiation Dampers. UL Classified High Free Area Minimal Pressure Drop

SD-1250 and SD-1600 Series Smoke Dampers

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

Life Safety Dampers - International. Fire Combination Fire Smoke Smoke Ceiling Radiation

Thermal Isolation. Break

VCD-23. Flange Options. Size Limitations

MULTI-BLADE FIRE DAMPERS

VCD-23 Low Leakage CONTROL DAMPER

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

VCD-23. Low Leakage CONTROL DAMPER

Model FDD Dynamic Curtain Fire Damper 1-½ or 3 Hour, UL555 Listed

Air Measuring Products. AMS Thermal Dispersion Pressure Differential

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:

MULTI-BLADE FIRE DAMPERS

Model VCD-43 Extruded Airfoil Blade Control Damper

CURTAIN TYPE FIRE DAMPER

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section

MODEL 151B FIRE DAMPER

Dynamic & Static Rated Fire Dampers, Ceiling Radiation Dampers. UL Classified High Free Area Minimal Pressure Drop

FSD60, FSD60LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 1

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER

SMOKE DAMPER - CLASS F MODEL BMSD

CURTAIN FIRE DAMPERS GENERAL PRODUCT OVERVIEW

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

COMBINATION FIRE/SMOKE DAMPER - CLASS F MODEL BMFSD (3 HR) / MODEL BEMFSD (1½ HR)

table of contents PRODUCT SUMMARY 2

Installation, Operation and Maintenance Instructions

Air Measuring Products AMD AMS IAQ

Installation, Operation and Maintenance Manual

HVAC Control & Balancing Dampers

BC 03. Fire Dampers FD-GB-30-AS LISTED

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

Blast Protection Damper

Document number AMS & AMD Damper Series for Honeywell Spyder Controller Installation, Operation, and Maintenance Instructions

RECEIVING AND HANDLING INSTALLATION SUPPLEMENTS WARRANTY SAFETY WARNING:

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

CFSD Series. Product Description

CEILING DAMPERS GENERAL PRODUCT OVERVIEW CEILING DAMPERS MODELS 0716, , 0714 & 0722 FOR SQUARE, RECTANGULAR OR ROUND DUCTS

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Model FD Static Curtain Fire Damper 1-½ or 3 Hour, UL555 Listed

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Smoke Dampers. Installation Instructions

Part # Installation,Operation and Maintenance Instructions

Direct Gas-Fired Heating

BC Motorized Fire Smoke Dampers MSFD-GB-30C1-A MSFD-GB-30C1-A LISTED

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION DUCTWORK ACCESSORIES

RD-2000 Round Control Dampers

Propeller Hooded Roof Fans

Installation, Operation and Maintenance Manual

Quiet-Duct Conic-Flow Silencers Section Specifications

SECTION DUCTWORK ACCESSORIES

Blast Protection Damper

Installation, Operation, and Maintenance Instructions

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories.

AMCA International. Guide for Commissioning and Periodic Performance Testing of Fire, Smoke and Other Life Safety Related Dampers

Transcription:

Application Model is approved for use in walls, floors, and partitions with fire resistance ratings of hours or more. This model carries a hour UL fire damper label. UL 555 classifies dynamic rated fire dampers for use in HVAC systems that are operational in the event of fire. Ratings UL555 Fire Resistance Rating Fire Rating: hours Dynamic Closure Rating Maximum Velocity: 4,000 fpm (20. m/s) vertical mount only, up to 24 in. x 24 in. (610mm x 610mm); 2,000 fpm (10.2 m/s) vertical or horizontal mount all sizes. Maximum Pressure: 4 in. wg (1 kpa) Construction Standard Optional Frame Material Frame Depth Blade Material Galvanized Steel* 11 16 in. (94mm) Galvanized steel* Closure Spring Stainless Steel Fusible Link 165 F (74 C) 212 F or 286 F (100 C) or (141 C) Mounting * in gauges required by UL listing R117 Optional Features Sealed transitions (requires sleeve) and sleeves Security bars One piece retaining angles (POC) Transitions (B, B2, C, CO, CR, R) Model Dynamic Rated Fire Damper Hour Fire Resistance Rating Model meets the requirements fro fire damper established by: National Fire Protection Association (NFPA Standards 80, 90A, & 101) IBC International Building Codes California State Fire Marshall (Listing # 225981:102) New Your City (MEA listing #26091M) See complete marking on product. UL 555 Classification R117 Stainless Steel Closure Spring Fusible Link (replaceable) 11/16 in. (94mm) Mount K side * These dimensions are furnished approximately 1 4 in. (6mm) undersize. Mount Installation instructions available at www.greenheck.com.

Factory Sleeve Option All fire damper installations require the use of sleeves, angles and methods described in the installation instructions. Sleeves can be field fabricated or factory furnished as a completed damper/sleeve assembly. Sleeves are galvanized steel and are available in 20 through 10 ga. (1mm.5mm) thicknesses and lengths up to 6 in. (914mm). K dimension specifies location of damper within the sleeve. Minimum is 4 in. (102mm), maximum is L less 4 in. (102mm), which allows for mounting angle installation, and duct connection at each end of the sleeve. If K dimension is not specified, it will be provided as one half of L dimension (damper centered in sleeve). Note: If using access doors, the door should be installed on the K side of the damper. Sleeve Damper K Damper CL Damper Frame Location L Overall Sleeve Length Sealed Option When sealed option is selected, B transition will need to be field sealed in the area where duct to sleeve connection is made. Type B with sleeve Seal this area.

Type A, B, & B2 Dampers larger than maximum single section sizes are supplied in 2 or more sections of equal size. If ordered with a factory sleeve, multisection dampers are factory assembled ready for installation. If ordered without a factory sleeve, multisection dampers require field assembly. Size Limitations P Inches (mm) Type A Type B & B2 Minimum Maximum Minimum Maximum 4 x 4 (102 x 102) 6 x 6 (914 x 914) 4 x (102 x 76) 6 x 1 (914 x 787) 1 1/2 in. Varies 1 1/2 in. 48 x 48 (1219 x 1219) 48 x 45 (1219 x 114) Type A W * 4 x 4 (102 x 102) 0 x 0 (762 x 762) 4 x (102 x 76) 0 x 26 (762 x 762) K dim. 40 x 6 (1016 x 914) 40 x (1016 x 88) Type B2 Sleeve Length Varies Limitations Maximum damper height is when combination width is or less. 6 in. (914mm) 6 in. (914mm) Type A Limitations Maximum damper height is 45 in. (114mm) when combination width is or less. 1 in.(787mm) 6 in. (914mm) 45 in. (114mm) Type B

Type A, B, & B2... Mount (76) 5 (127) 25 (65) 29 (77) 4 (102) 6 (152) 26 (660) 0 (762) 5 (127) 7 (178) 6 (152) 8 (20) 7 (178) 9 (229) 27 (686) 1 (787) 28 (711) 2 (81) 29 (77) (88) Type B Mount Type B2 8 (20) 10 (254) 0 (762) 4 (864) 9 (229) 11 (279) 1 (787) 6 (914) (76) 5 (127) 19 (48) 22 (559) 10 (254) 12 (05) 2 (81) 7 (940) 4 (102) 6 (152) 20 (508) 2 (584) 11 (279) 1 (0) (88) 7 (940) 5 (127) 7 (178) 21 (5) 24 (610) 12 (05) 14 (56) 4 (864) 7 (940) 6 (152) 8 (20) 22 (559) 26 (660) 1 (0) 15 (81) 5 (889) 8 (965) 7 (178) 9 (229) 2 (584) 27 (686) 14 (56) 16 (406) 6 (914) 9 (991) 8 (20) 10 (254) 24 (610) 28 (711) 15 (81) 18 (457) 7 (940) 40 (1016) 9 (229) 11 (279) 25 (65) 29 (77) 16 (406) 19 (48) 8 (965) 41 (1041) 10 (254) 12 (05) 26 (660) 0 (762) 17 (42) 20 (508) 9 (991) 42 (1067) 11 (279) 1 (0) 27 (686) 1 (787) 18 (457) 21 (5) 40 (1016) 4 (1092) 12 (05) 14 (56) 28 (711) 1 (787) 19 (48) 22 (559) 41 (1041) 44 (1118) 1 (0) 15 (81) 29 (77) 2 (81) 20 (508) 2 (584) 42 (1067) 45 (114) 14 (56) 16 (406) 0 (762) (88) 21 (5) 24 (610) 4 (1092) 46 (1168) 15 (81) 18 (457) 1 (787) 4 (864) 22 (559) 26 (660) 44 (1118) 47 (1194) 16 (406) 19 (48) 2 (81) 5 (889) 2 (584) 27 (686) 45 (114) 48 (1219) 17 (42) 20 (508) (88) 6 (914) 24 (610) 28 (711) 18 (457) 21 (5) * Dimension is inches (mm). These dimensions are furnished approximately 1 4 in. (6mm) undersize. All H dimensions larger than single section height are two sections high. Refer to size limitations chart. The top section is a Type B/B2 and the bottom section are Type A. Type C, CO, CR, & R Dampers larger than maximum single section sizes are supplied in 2 or more sections of equal size. Note: All multiple section dampers with transitions, will include a factory installed sleeve. Inches (mm) section Type CR Type CO & C Type R* 1 Minimum Maximum Minimum Maximum Minimum Maximum 0 x 4 x 0 4 (76) (762) (76 x 76) (864 x 762) (76) (864) 44 46 x 44 46 (1118) (1168 x 1118) (1168) 25 x 28 x 25 28 (76) (65) (76 x 76) (711 x 65) (76) (711) 2 8 x 2 4 (81) (965 x 81) (864) *1 With 2 in. (51mm) offset. Sizes adjust with 0 offset and 1 in. (25mm) offset. ** Consult factory for number of sections.

Type C, CO, CR & R... Maximum Dimensions Overall Damper Dimensions Type C Type CO Type CR +2 0in. 0 in. 4 in. (864mm) 4 in. (864mm) Type CO +2 Type CR Type R +2 Type C 0 in. 4 in. (889mm) Type R transition is centered on damper frame. (Dimension are with 2 in. (51mm) offset.) C, CO, CR transitions are positioned 1 in. (25mm) from bottom of sleeve. or Mount or or (76) 6 (152) 17 (42) 21 (5) 1 (787) 7 (940) 4 (102) 7 (178) 18 (457) 22 (559) 2 (81) 7 (940) 5 (127) 8 (20) 19 (48) 2 (584) (88) 7 (940) 6 (152) 9 (229) 20 (508) 24 (610) 4 (864) 8 (965) 7 (178) 10 (254) 21 (5) 26 (660) 5 (889) 9 (991) 8 (20) 11 (279) 22 (559) 27 (686) 6 (914) 40 (1016) 9 (229) 12 (05) 2 (584) 28 (711) 7 (940) 41 (1041) 10 (254) 1 (0) 24 (610) 29 (77) 8 (965) 42 (1067) 11 (279) 14 (56) 25 (65) 0 (762) 9 (991 4 (1092) 12 (05) 15 (81) 26 (660) 1 (787) 40 (1016) 44 (1118) 1 (0) 16 (406) 27 (686) 2 (81) 41 (1041) 45 (114 14 (56) 18 (457) 28 (711) (88) 42 (1067) 46 (1168)) 15 (81) 19 (48) 29 (77) 4 (864) 4 (1092) 47 (1194 16 (406) 20 (508) 0 (762) 6 (914) 44 (1118) 48 (1219) Mount or or (76) 6 (152) 18 (457) 22 (559) 4 (102) 7 (178) 19 (48) 2 (584) 5 (127) 8 (20) 20 (508) 24 (610) 6 (152) 9 (229) 21 (5) 26 (660) 7 (178) 10 (254) 22 (559) 27 (686) 8 (20) 11 (279) 2 (584) 28 (711) 9 (229) 12 (05) 24 (610) 29 (77) 10 (254) 1 (0) 25 (65) 0 (762) 11 (279) 14 (56) 26 (660) 1 (787) 12 (05) 15 (81) 27 (686) 1 (787) 1 (0) 16 (406) 28 (711) 2 (81) 14 (56) 18 (457) 29 (77) (88) 15 (81) 19 (48) 0 (762) 4 (864) 16 (406) 20 (508) 1 (787) 5 (889) 17 (42) 21 (5) 2 (81) 6 (914) * Dimension is inches (mm). These dimensions are furnished approximately 1 4 in. (6mm) undersize. All H dimensions larger than single section height are two sections high. Refer to size limitations chart. Copyright 2016 Greenheck Corporation Rev. 12 January 2016